Infrastruktur
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (951)
- Zeitschriftenartikel (524)
- Beitrag zu einem Tagungsband (371)
- Posterpräsentation (165)
- Buchkapitel (46)
- Sonstiges (25)
- Forschungsbericht (22)
- Beitrag zu einem Sammelband (18)
- Dissertation (17)
- Forschungsdatensatz (10)
Sprache
- Englisch (1403)
- Deutsch (754)
- Mehrsprachig (8)
- Tschechisch (2)
- Französisch (1)
- Polnisch (1)
Schlagworte
- Korrosion (113)
- Concrete (112)
- Corrosion (93)
- Monitoring (54)
- Ultrasound (54)
- Potentialfeldmessung (44)
- Structural health monitoring (43)
- Beton (42)
- Alkali-activated materials (39)
- LIBS (39)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (1138)
- 8 Zerstörungsfreie Prüfung (556)
- 2 Prozess- und Anlagensicherheit (326)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (256)
- 7.2 Ingenieurbau (253)
- 3 Gefahrgutumschließungen; Energiespeicher (248)
- 2.1 Sicherheit von Energieträgern (230)
- 7.6 Korrosion und Korrosionsschutz (227)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (210)
- 7.4 Baustofftechnologie (166)
Paper des Monats
- ja (24)
In this study, multicomponent flame retardant systems, consisting of Ammonium polyphosphate (APP), aluminum trihydroxide (ATH), and polyaniline (PANI), were used in ethylene propylene diene monomer (EPDM) rubber. The multicomponent system was designed to improve flame retardancy and the mechanical properties of the rubber compounds, while simultaneously reducing the amount of filler. PANI was applied at low loadings (7 phr) and combined with the phosphorous APP (21 phr) and the mineral flame retardant ATH (50 phr). A comprehensive study of six EPDM rubbers was carried out by systematically varying the fillers to explain the impact of multicomponent flame retardant systems on mechanical properties. The six EPDM materials were investigated via the UL 94, limiting oxygen index (LOI), FMVSS 302, glow wire tests, and the cone calorimeter, showing that multicomponent flame retardant systems led to improved fire performance.
In cone calorimeter tests the EPDM/APP/ATH/PANI composite reduced the maximum average rate of heat emission (MARHE) to 142 kW·m-2, a value 50% lower than that for the unfilled EPDM rubber. Furthermore, the amount of phosphorus in the residues was quantified and the mode of action of the phosphorous flame retardant APP was explained. The data from the cone calorimeter were used to determine the protective layer effect of the multicomponent flame retardant systems in the EPDM compounds.
To reduce the emission of carbondyoxide (CO2) of combustion engines, liquefied natural gas (LNG) is used as an alternative fuel. LNG is transported via truck, ship or railway for long distances. Double walled stainless steel tanks are used for transportation, which are heavy and expensive. The vacuum insulation between the two walled structure ensures that the LNG stays liquid over the transportation time (boiling point of LNG: -162 ◦C). This causes a high temperature difference between the transported good and the ambient air.
A simplified tank construction is used to reduce the weight and price of the tank. Instead of stainless steel, glass fiber reinforced plastic (GFRP) is used. The design is changed to a single walled construction with a solid insulation material outside on the GFRP structure.
Goal of this work is the characterization of a suitable insulation material and configuration as well as the analysis of the mechanical properties of GFRP under cryogenic conditions. Several experiments are carried out. Numerical models of these experiments can then be used for parameter studies.
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM) approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a General reference model is obtained from data in the reference state at several known reference temperatures.
Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space Matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
The subject of damage localization is an important issue for Structural Health Monitoring (SHM) particularly in mechanical or civil structures under ambient excitation. In this paper, the statistical subspacebased damage localization method has been applied on a benchmark application, namely a 1/200 scale model of the Saint-Nazaire Bridge, which is a cable-stayed bridge located on the Loire River near the river’s mouth. The employed damage localization method combines data-driven features with physical parameter information from a finite element model in statistical tests, avoiding typical ill-conditioning problems of FE model updating. Damage is introduced in the mockup for cable failures on some of the 72 cables. The purpose of the experiment is to assess the capability of damage assessment methods to find a cable failure.
The Stochastic Dynamic Damage Locating Vector (SDDLV) approach is a vibration-based damage localization method based on both a finite element model of a structure and modal parameters estimated from output-only measurements in the damage and reference states. A statistical version of the Approach takes into account the inherent uncertainty due to noisy measurement data. In this paper, the effect of temperature fluctuations on the performance of the method is analyzed in a model-based approach using a finite element model with temperature dependent parameters. Robust damage localization is carried out by rejecting the temperature influence on the identified modal parameters in the damaged state. The algorithm is illustrated on a simulated structure.
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM) approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a general reference model is obtained from data in the reference state at several known reference temperatures. Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
Materials with a high acid resistance are required in different important infrastructures. Examples include repair systems for sewer structures, where biogenic sulfuric acid corrosion is the major degradation mechanism. Low-calcium alkali-activated materials (AAMs) have been repeatedly observed to exhibit high acid resistance. However, the reasons for the high acid resistance of these materials were not fully under¬stood until recently, and the use of highly alkaline activator solutions to produce AAMs appears to hamper their commercial uptake. These issues have been tackled by characterising one-part AAMs and studying their alteration when exposed to sulfuric acid.
One-part AAMs were synthesized by mixing blends of solid silica and sodium aluminate with water, and subsequent curing at 60–80 °C. Acid resistance testing was performed according to DIN 19573, i.e. exposure to sulfuric acid at pH = 1 for 70 days. Characterisation of the cured and the acid-exposed materials was done by XRD, ATR-FTIR, SEM as well as 29Si, 27Al and 1H MAS NMR spectroscopy, including cross-polarisation and double-resonance methods.
Materials synthesized from industrial silicas were gel-zeolite composites, containing a substantial amount of unreacted ‘excess’ silica, while materials synthesized from rice husk ash were fully amorphous, containing ‘excess’ hydrous alumina. The sulfuric acid resistance of mortars based on these binders conformed to the requirements of DIN 19573 for sewer repair applications. The high acid resistance was caused by precipitation of silica gel at the mortar–solution interface, inhibiting further degradation. The presence of alumina gel may inhibit bacterial activity, potentially further improving performance in sewer environments.
The phase assemblage of silica/sodium aluminate-based one-part AAMs can be adjusted via choice of the silica starting material. Properly designed materials exhibit excellent acid resistance, caused by precipi¬tation of silica gel which protects subjacent regions, and they may also inhibit bacterial activity.
This work focuses on the question if the bubble test prescribed in the Dangerous Goods Regulations has sufficient sensitivity to detect leakage rates which could result in the formation of explosive atmospheres during transport. The sensitivity of the bubble test is not directly comparable with other leak testing methods because of its different flow conditions.
Therefore, a normalized minimum detectable leakage rate under Helium test conditions is calculated for the bubble test. This sensitivity of the bubble test under reference conditions is compared with limit leakage rates for a worst-case transport scenario. The sensitivity of the bubble test is not sufficient to prove the limit leakage rates for 6-L packagings. The Formation of explosive vapour-air-mixtures cannot be excluded. Therefore, more sensitive leak testing methods should be considered for smaller packaging design types.
This presentation describes the testing methods used to determine the thermal properties of insulation materials and mechanical properties of materials used for the load-bearing structure for pressure tanks (up to 4 bar) and cryogenic liquids (LNG, -162 °C at atmospheric pressure). Goal is to design a transportation tank that does not exceed 4 bars (relative) within 10 h, starting at atmospheric pressure. PUR-foam is a suitable material for the insulation. A 12,5 l small scale tank prototype reached 4 bar (relative) within 87 minutes, which is, regarding the influence of the size, a satisfying result. The mechanical properties change significantly at cryogenic temperatures. The bending modulus is similar at first, but decreases at a certain point by 2/3. However, the maximum stress is much higher and could not be reached within this testing setup.
Im 2. Teil des Artikels zu den Untersuchungen zum Einfluss von Rohrleitungsverzweigungen auf die Wirksamkeit von Deflagrationsrohrsicherungen (s. a. [1]) werden die Ergebnisse der visuellen Beobachtungen des Reaktionsverlaufes sowie die Belastungen der Flammendurchschlagsicherung (s. Bild 1) bei unterschiedlichen Einbaubedingungen in den Vordergrund gestellt. Gegenübergestellt wird die Belastungssituation der Flammensperre in einer geraden und einer verzweigten Rohrleitung. Ausdrücklich wurden Einbaubedingungen gewählt, die nicht Normgerecht [2] sind. Verwendet wurde dafür eine speziell gefertigte Deflagrationsrohrsicherung, die eine Beobachtung des Reaktionsverlaufs im Bereich der spiralförmig gewickelten Metallbänder erlaubt. Zusätzlich wurde im geschützten Bereich in der Rohrleitung eine Kamera installiert, die die Belastungssituation bei den einzelnen Versuchen dokumentierte. Die Ergebnisse bestätigen sehr eindrucksvoll, dass die Belastungssituation der Deflagrationsrohrsicherung sich in Abhängigkeit von der Konfiguration der Rohrleitung entscheidend ändert.
For the purpose of increasing payload and reduce freight cost, lightweight composite tank containers used for Transportation have been progressively developed during the last years. Compared to conventionally produced cylindrical steel tanks, the fiber-reinforced solutions allow greater flexibility in the tank design. Despite a number of further material-related benefits of fiber-reinforced composites as non-conductive and non-magnetic behavior as well as corrosion resistance and high strength, the optimization of their thermal degradation properties during combustion is still a challenge. To improve the fire performance of lightweight composite containers, special intumescent fire protection coatings can be applied onto the outside tank surface. This paper presents fire tests on glass-fiber-reinforced plastic transport tanks with complex geometries sheltered with different surface-applied fire protection systems. To evaluate the fire resistance of the tank structures, a fiber optic monitoring system was developed. This system is based on distributed temperature measurements using high-Resolution optical backscatter reflectometry and pointwise reference measurements using fiber Bragg gratings. Thereby, all the fiber optic sensors were directly integrated in the composite layer structure of the tanks. The focus of the presented work is on the demonstration of capability of fiber optic monitoring system in such high-temperature application. Moreover, the fiber optic measurements provide new insights into the efficiency of intumescent coating applied for fire protection of fiber-reinforced plastic transport tanks.
The presented results gained within the project "CoFi-ABV - Consequences of tank failure" give detailed insights into the potential consequences of tank failure of commercial 11 kg propane cylinders and the LPG tank installed in a car in case of a misfunction of the safety device. In comprehensive test campaigns performed on the Test Site for Technical Safety of BAM (BAM TTS), 15 off-the-shelf propane bottles and three passenger cars with a LPG tank were exposed to an intensive fire. Sensors and measurement equipment were used to gain data (temperature, pressure, dynamic overpressure, thermal radiation, video data) enabling an analysis of the consequences of tank failure and for the continuous monitoring of the experiments.
In this study, an Impulse Response Function analysis of pile response to sine-sweep excitation by a low cost, portable Shaker was used to identify defects in piles. In straightforward impact-echo methods, echoes from the pile toe and defects are visible in the time domain measurements. However, these echoes are not present in the time domain records of piles subjected to sine-sweep excitations, due to interactions between the input and output signals. For this reason, the impulse response function in the time domain has been calculated and is able to identify the echoes from pile impedance changes. The proposed methodology has been evaluated both numerically and experimentally. A one-dimensional pile-soil interaction system was developed, and a finite difference method used to calculate the pile response to sine-sweep excitation. The numerical simulations indicate that impulse response measurements with a synthesized logarithmic, sine-sweep excitation could be an effective tool for detecting defects in piles. The methodology was further tested with field trials on 6 cast in situ concrete test piles including 1 intact pile and 5 defective piles subjected to sine-sweep excitations by a shaker. In 5 of the 6 cases the echoes from the pile toe could be identified in the deconvoluted waveforms—the impulse Response functions. Damage detection is more difficult and dependent on the selection of the optimal regularization parameter. Further research and optimization of the deconvolution process is needed to evaluate the effectiveness compared to standard pile integrity testing methods.
The subject of damage localization is an important issue for Structural Health Monitoring (SHM) particularly in mechanical or civil structures under ambient excitation. In this paper, the statistical subspacebased damage localization method has been applied on a benchmark application, namely a 1/200 scale model of the Saint-Nazaire Bridge, which is a cable-stayed bridge located on the Loire River near the river’s mouth. The employed damage localization method combines data-driven features with physical parameter information from a finite element model in statistical tests, avoiding typical ill-conditioning problems of FE model updating. Damage is introduced in the mockup for cable failures on some of the 72 cables. The purpose of the experiment is to assess the capability of damage assessment methods to find a cable failure.
The Stochastic Dynamic Damage Locating Vector (SDDLV) approach is a vibration-based damage localization method based on both a finite element model of a structure and modal parameters estimated
from output-only measurements in the damage and reference states. A statistical version of the Approach takes into account the inherent uncertainty due to noisy measurement data. In this paper, the effect of temperature fluctuations on the performance of the method is analyzed in a model-based approach using a finite element model with temperature dependent parameters. Robust damage localization is carried out by rejecting the temperature influence on the identified modal parameters in the damaged state. The algorithm is illustrated on a simulated structure.
Within the presented research project, experimental and numerical investigations were performed to develop a thin-shelled, modular, mobile element system made of a micro-reinforced ultra-high-performance ductile concrete (DUCON®). Material parameters were experimentally determined to adapt the material model within the numerical analysis applying the Drucker-Prager relationship. Afterwards, for validation of the numerical models, quasi-static and high-velocity impact tests were performed on plate-like structures. Finally, a suitable geometry of transportable barrier elements will be designed, which provides a maximum of resistance against impact by a minimum of weight and a maximum of mobility.
Der steigende Einsatz von Holz-Kunststoff-Verbundwerkstoffen (Wood Plastic Composite, WPC) erfordert das Wissen um seine spezifischen Eigenschaften, insbesondere dem Brand risiko.
Dabei können Flammschutzmittel die Entflammbarkeit, Wärmeabgabe und die Brandausbreitung des Materials verringern.
Deshalb sind der gezielte und effiziente Einsatz und die Kenntnis über die Wirkungsweise der Flammschutzmittel im WPC für den Brandschutz von enormer Bedeutung. Dazu gehört auch die Rauchentwicklung im Brandfall. Rauch beeinflusst aufgrund seiner Toxizität und seiner Sichttrübung die Fluchtmöglichkeit der betroffenen Personen. In der Rauchkammer nach ISO 5659-2 wird die Rauchentwicklung von flachen Werkstoffproben ermittelt. Die Rauchgastoxizität bzw. die Rauchgaszusammensetzung wird mithilfe der FTIR (Fourier Transformierte Infrarot)-Spektroskopie ermittelt. Frei werdende Partikel schädigen die Atemorgane und beeinflussen damit auch die Fluchtfähigkeit von Personen im Brandfall. Aussagen zur Partikelemission können mithilfe eines an die Rauchkammer gekoppelten Partikelanalysators getroffen werden. Im Rahmen dieser Arbeit wurden verschiedene flammgeschützte WPC-Systeme hinsichtlich ihres Rauchverhaltens in der Rauchkammer untersucht. Die Ergebnisse zu emittierten toxischen Gasen, Partikeln und zur Rauchentwicklung werden vorgestellt und in Abhängigkeit von den eingesetzten Flammschutzmitteln im WPC diskutiert.
Flame retardants (FR) are inevitable additives to many plastics. Halogenated organics are effective FRs but are controversially discussed due to the release of toxic gases during a fire or their persistence if landfilled. Phosphorus-containing compounds are effective alternatives to halogenated FRs and have potential lower toxicity and degradability. In addition, nitrogencontaining additives were reported to induce synergistic effects with phosphorus-based FRs. However, no systematic study of the gradual variation on a single phosphorus FR containing both P−O and P−N moieties and their comparison to the respective blends of phosphates and phosphoramides was reported. This study developed general design principles for P−O- and P−N-based FRs and will help to design effective FRs for various polymers. We synthesized a library of phosphorus FRs that only differ in their P-binding pattern from each other and studied their decomposition mechanism in epoxy resins. Systematic control over the decomposition pathways of phosphate (PO(OR)3), phosphoramidate (PO(OR)2(NHR)), phosphorodiamidate (PO(OR)(NHR)2), phosphoramide (PO(NHR)3), and their blends was identified, for example, by reducing cis-elimination and the formation of P−N-rich char with increasing nitrogen content in the P-binding sphere. Our FR epoxy resins can compete with commercial FRs in most cases, but we proved that the blending of esters and amides outperformed the single molecule amidates/diamidates due to distinctively different decomposition mechanisms acting synergistically when blended.
Gegenüber dem Neubauentwurf können bei der Bewertung von bestehender Bausubstanz Sicherheitsreserven genutzt werden, da Unsicherheiten, die beim Bau auftreten können, besser bekannt oder nicht mehr vorhanden sind. Können solche Unsicherheiten genauer bewertet werden, z. B. durch die Feststellung der genauen Lage der Spannglieder bei einer Spannbetonbrücke, so können Sicherheitsbeiwerte reduziert werden, ohne dass es dabei zu Auswirkungen auf das normativ festgelegte Zuverlässigkeitsniveau kommt. Mittlerweile sind Prüfmethoden an Bauwerken wirtschaftlich einsetzbar und auch so leistungsfähig, dass die für die Tragfähigkeit und Gebrauchstauglichkeit wesentlichen Parameter identifiziert werden können. Ein wesentlicher Punkt ist hierbei die Integration derartiger Messergebnisse in Rechenmodelle, die für die Nachrechnung des Bauwerks verwendet werden. Dies können sowohl semiprobabilistische Rechenmodelle als auch vollprobabilistische Modelle sein. Bei semiprobabilistischen Methoden können aus den Messergebnissen Teilsicherheitsbeiwerte berechnet und abgeleitet werden, die dann in den bekannten Nachweisformaten gemäß den Eurocodes und der Nachrechnungsrichtlinie berücksichtigt werden. Bei vollprobabilistischen Nachweisen können die Messdaten in Form von Verteilungsdichtefunktionen mit gemessenen Variationskoeffizienten direkt in das Rechenmodell eingehen. In einer dreiteiligen Aufsatzreihe werden die Messverfahren und die Nutzung der Ergebnisse bei der Nachrechnung vorgestellt. Der vorliegende Teil 1 zeigt die Möglichkeiten des Einsatzes von zerstörungsfreien Prüfverfahren und bewertet deren Leistungsfähigkeit. Messen heißt wissen. Dieses Wissen spiegelt die Realität wider und soll den Tragwerksplaner bei der Entscheidungsfindung über die Sicherheit und Zuverlässigkeit von Bestandsbauwerken unterstützen.
To exploit application fields beyond packaging for biodegradable materials, flame retardancy and increased mechanical strength are usually required. This work focuses on the flammability of a thermoplastic starch/polyester blend reinforced with natural fibers derived from Mexican industry processes wastes, such as keratin fibers from the tannery industry, coconut fibers (coconut industry), and agave tequilana fibers and henequen fibers from tequila industry. Different fiber contents as well as combinations of varying contents of aluminum trihydroxide, expandable graphite, aluminum diethylphosphinate or ammonium polyphosphate are investigated. It is the goal to propose sustainable waste fibers as adjuvants improving the flame retardancy. This work provides the proof of principle for sustainable biodegradable flame retarded biocomposites.
An analysis has been presented pertaining to the use of a convex
bottom tank shape instead of an elliptical, for a road tanker.
Two analyses have been made, concerning the static and the dynamic
relative performance expectations of such tank shape when compared
with the elliptical shape performance.
The outputs of both analyses suggest that the level of average benefit
due to using the proposed shape, is around 10%, with a maximum
benefit observed in the dynamic performance in the case of the
minimum fill level.
Correlation between static and dynamic outputs. Manufacturing.
The potential benefits to the roll stability of a road tanker, derived from using a convex-bottom tank, instead of a concave-bottom one, are assessed. The convex-bottom tank consists of a modified elliptical figure to which the concave bottom is substituted by a convex one. The concave-bottom consists of an elliptical shape. Static and dynamic analyses are performed, for which the proposed shape revels enhancements on the order of 10%. The static rollover stability factor, and the lateral load transfer ratio, are used as performance measures for the static and the dynamic analysis, respectively. The dynamic analysis derives from a simplified model, for which the sloshing mass is substituted by a calibrated simple pendulum. Other potential benefits of the proposed tank shape are discussed, including a reduction in the aerodynamic drag, and a longer life for the vehicle components.
Longitudinal Load transfer light sensitivity to cargo type, fill level and the impact distance.
Maximum sloshing effect for the case of the lowest fill level 12
while for half fill level the sloshing cargo performs as a dynamic damper, with a maximum effect of 6 in the case of medium impact input
The sloshing effect for the highest fill level yielded a mixed output, with the maximum impact distance producing a positive but moderate effect.
The interaction between the sloshing cargo and the carrying vehicle has been predominantly studied from the perspective of road safety, aiming at characterizing the effects of cargo motion on both, the lateral stability of the vehicles and the respective braking performance. In this regard, one main issue is to objectively clarify the potential effects of the sloshing cargoes, when compared with solid or non-sloshing cargoes. While there are abundant theoretical studies about the comparative effects of one substance and the other on the vehicle performance, only few experimental studies have been reported with that approach. In this paper, the outputs from an experimental study involving the longitudinal load transfer of sloshing and non-sloshing cargoes, is presented. The longitudinal load transfer is characterized in this paper on the basis of the moment of the reaction forces at the wheel-support interface, with respect to the impact spot. Results suggest that for one-quarter fill level, the sloshing cargo produces an amplification of the performance measure (12% maximum) while at half fill level the sloshing cargo damps the outputs (6.31 % reduction), while at high fill levels, the sloshing effect is mixed, as a function of the impact input, from -1.1% at low impact distance, to +6.6 for large impact distance.
Es wird die Vorgehensweise erläutert wie die Notwendigkeit einer elastischen Gebäudelagerung geprüft wird. Es werden die Möglichkeiten und Schwächen vereinfachter Rechenverfahren dargestellt. Es folgen weitere Beispiele detaillierter Gebäudemodelle und ihres Schwingungsverhaltens. Schließlich greift eine aktuelle Bachelorarbeit die Fragestellung komplexen Gebäudeschwingungsverhaltens auf. Die letzte Folie zeigt dazu Gebäudemodelle, die an die konkreten Erschütterungsprognosen anknüpfen.
Es wurden insgesamt 57 Einzelversuche zum Versagen von Druckgasbehältern durchgeführt. Untersucht wurden dabei 11-kg-Propangasflaschen, PKW-Radmuldentanks für LPG- sowie CNG-Tanks vom Typ III (Compositetanks mit Aluminiumliner) und Typ IV (Compositetanks mit Polymerliner). Mit 18 hydraulischen Berstversuchen wurde das Versagensverhalten unter kalten Bedingungen charakterisiert. In 39 Unterfeuerungsversuchen mit den gefüllten LPG- und CNG-Tanks, davon 36 mit Tanks ohne Sicherheitseinrichtung, wurde das Behälter¬ver¬sagen durch Brandbeaufschlagung untersucht. Neben verschiedenen Behältermantel¬temperaturen und dem Behälterinnendruck wurde auch die Temperatur des gespeicherten Mediums dokumentiert. Dadurch war es möglich, genau zu dokumentieren, unter welchen Bedingungen und bei welchem Zustand der Behälter versagt hat. In einem Großteil der Unterfeuerungsversuche mit Behältern ohne Sicherheitseinrichtungen kam es zur Bildung eines Feuerballs, einer massiven Druck- und Temperaturwirkung auf den Nahbereich sowie einer Vielzahl von Fragmenten im Nah- und Fernbereich. In einer Entfernung von l = 7 m wurden Überdrücke von bis zu p = 0,41 bar gemessen. In 30 Unterfeuerungsversuchen kam es zur Fragmentierung des Behälters. Dabei konnten 159 Fragmente mit Wurfweite und Masse dokumentiert werden. Die dabei maximal festgestellte Wurfweite eines Fragments lag bei l = 311 m.
Deflagrationsrohrsicherungen sind Sicherheitseinrichtungen, die den Durchfluss von brennbaren Gasen und Dämpfen brennbarer Flüssigkeiten ermöglichen, den Flammendurchschlag und eine weitere Explosionsausbreitung nach der Zündung von explosionsfähigen Gas-/Dampf-Luftgemischen jedoch verhindern sollen. Die Einbaubedingungen sind dabei von besonderer Bedeutung für die Wirksamkeit der Deflagrationsrohrsicherungen. Oft lassen sich aus betrieblichen bzw. verfahrenstechnischen Gründen entsprechende Einbaubedingungen nur schwer oder nicht realisieren. So können beispielsweise Rohrleitungsverzweigungen zusätzliche Turbulenzen induzieren und dadurch zu erhöhten Flammenausbreitungsgeschwindigkeiten und Explosionsdrücken und ggf. zum Versagen der Deflagrationsrohrsicherung führen. Neben den „klassischen“ Untersuchungsmethoden dieser Belastungssituationen von Deflagrationsrohrsicherungen, wie die Erfassung des Explosionsdruckes und der Flammenausbreitungsgeschwindigkeiten, werden in diesem Beitrag die Ergebnisse der visuellen Beobachtungen des Reaktionsverlaufes sowie die Belastungen der Flammendurchschlagsicherung bei unterschiedlichen Einbaubedingungen in den Vordergrund gestellt. Gegenübergestellt wird die Belastungssituation der Flammensperre in einer geraden und einer verzweigten Rohrleitung. Verwendet wurde dafür eine speziell gefertigte Deflagrationsrohrsicherung, die eine Beobachtung des Reaktionsverlaufs im Bereich der spiralförmig gewickelten Metallbändern erlaubt. Zusätzlich wurde im geschützten Bereich in der Rohrleitung eine Kamera installiert, die die Belastungssituation bei den einzelnen Versuchen dokumentierte. Die Ergebnisse bestätigen sehr eindrucksvoll, dass die Belastungssituation der Deflagrationsrohrsicherung sich in Abhängigkeit von der Konfiguration der Rohrleitung entscheidend ändert.
Deflagrationsrohrsicherungen sind Sicherheitseinrichtungen, die den Durchfluss von brennbaren Gasen und Dämpfen brennbarer Flüssigkeiten ermöglichen, den Flammendurchschlag und eine weitere Explosionsausbreitung nach der Zündung von explosionsfähigen Gas-/Dampf-Luftgemischen jedoch verhindern sollen. Die Einbaubedingungen sind dabei von besonderer Bedeutung für die Wirksamkeit der Deflagrationsrohrsicherungen. Oft lassen sich aus betrieblichen bzw. verfahrenstechnischen Gründen entsprechende Einbaubedingungen nur schwer oder nicht realisieren. So können beispielsweise Rohrleitungsverzweigungen zusätzliche Turbulenzen induzieren und dadurch zu erhöhten Flammenausbreitungsgeschwindigkeiten und Explosionsdrücken und ggf. zum Versagen der Deflagrationsrohrsicherung führen. Neben den „klassischen“ Untersuchungsmethoden dieser Belastungssituationen von Deflagrationsrohrsicherungen, wie die Erfassung des Explosionsdruckes und der Flammenausbreitungsgeschwindigkeiten, werden in diesem Beitrag die Ergebnisse der visuellen Beobachtungen des Reaktionsverlaufes sowie die Belastungen der Flammendurchschlagsicherung bei unterschiedlichen Einbaubedingungen in den Vordergrund gestellt. Gegenübergestellt wird die Belastungssituation der Flammensperre in einer geraden und einer verzweigten Rohrleitung. Verwendet wurde dafür eine speziell gefertigte Deflagrationsrohrsicherung, die eine Beobachtung des Reaktionsverlaufs im Bereich der spiralförmig gewickelten Metallbändern erlaubt. Zusätzlich wurde im geschützten Bereich in der Rohrleitung eine Kamera installiert, die die Belastungssituation bei den einzelnen Versuchen dokumentierte.
Die Ergebnisse bestätigen sehr eindrucksvoll, dass die Belastungssituation der Deflagrationsrohrsicherung sich in Abhängigkeit von der Konfiguration der Rohrleitung entscheidend ändert
Es wurden insgesamt 57 Einzelversuche zum Versagen von Druckgasbehältern durchgeführt. Untersucht wurden dabei 11-kg-Propangasflaschen, PKW-Radmuldentanks für LPG- sowie CNG-Tanks vom Typ III (Compositetanks mit Aluminiumliner) und Typ IV (Compositetanks mit Polymerliner). Mit 18 hydraulischen Berstversuchen wurde das Versagensverhalten unter kalten Bedingungen charakterisiert. In 39 Unterfeuerungsversuchen mit den gefüllten LPG- und CNG-Tanks, davon 36 mit Tanks ohne Sicherheitseinrichtung, wurde das Behälterversagen durch Brandbeaufschlagung untersucht. Neben verschiedenen Behältermanteltemperaturen und dem Behälterinnendruck wurde auch die Temperatur des gespeicherten Mediums dokumentiert. Dadurch war es möglich, genau zu dokumentieren, unter welchen Bedingungen und bei welchem Zustand der Behälter versagt hat. In einem Großteil der Unterfeuerungsversuche mit Behältern ohne Sicherheitseinrichtungen kam es zur Bildung eines Feuerballs, einer massiven Druck- und Temperaturwirkung auf den Nahbereich sowie einer Vielzahl von Fragmenten im Nah- und Fernbereich. In einer Entfernung von l = 7 m wurden Überdrücke von bis zu p = 0,41 bar gemessen. In 30 Unterfeuerungsversuchen kam es zur Fragmentierung des Behälters. Dabei konnten 159 Fragmente mit Wurfweite und Masse dokumentiert werden. Die dabei maximal festgestellte Wurfweite eines Fragments lag bei l = 311 m.
In this contribution a Proper Generalized Decomposition model is derived for linear elastic structures with Young's modulus as extra-coordinates. Next, the computed PGD solution is used in a Bayesian model updating algorithm resulting a probability distribution of the searched model parameter for given synthetic data. The future goal is to extend the method to be able to identify arbitrary material parameters, based on experimental data.
Smart geosynthetics with embedded optical fibers as distributed sensors provide solutions both for applications in geotechnical engineering and for cost-effective monitoring of critical infrastructures. The incorporation of glass or polymer optical fibers (GOFs or POFs) in geotextiles and geogrids allows early detection of mechanical deformations, temperature and humidity. This paper presents selected examples of smart geosynthetics based on Brillouin and Rayleigh scattering effects in incorporated fiber optic sensors for monitoring of large geotechnical structures like dikes, dams, railways, embankments or slopes. The focus of the presented work is on real field tests of measurement capability with respect to the chosen measurement principle and used fiber type.
In this paper, we introduce a nano aerial robot swarm for indoor air quality monitoring applications such as occupational health and safety of (industrial) workplaces. The concept combines a robotic swarm composing of nano Unmanned Aerial Vehicles (nano UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight metal oxide gas sensors for measuring the Total Volatile Organic Compound (TVOC) in ppb and estimating the eCO2 (equivalent calculated carbon-dioxide) concentration in ppm. TVOC is a measure for the indoor air quality. An indoor localization and positioning system will be used to estimate the absolute 3D position of the swarm like GPS. Based on this novel indoor air quality monitoring concept, the development and validation of new algorithms in the field of Mobile Robot Olfaction (MRO) are planned, namely gas source localization and gas distribution mapping. A test scenario will be built up to validate and optimize the gas-sensitive nano aerial robot swarm for the intended applications.
The Measurement- and Model-based Structural Analysis (MeMoS) integrates a finite element model into least squares adjustment and thus allows to evaluate a mechanical model and measurements in a combined analysis. To examine the capability to detect and localise damage using this integrated analysis MeMoS, a small-scale truss bridge made of aluminium profiles is built as a test specimen for this purpose.
In mobile robot applications, some sensors such as open-path gas detectors or laser rangefinders need to be aimed at specific targets in order to get the desired measurements. To do this in a fast and elegant manner, we present a spherical parallel manipulator with three degrees of freedom. Compared to typical serial manipulators, it offers superior dynamics and structural stiffness, which are important parameters for this type of task. We present the mechanical design and derive kinematic equations both to compute set-points for the desired orientation and to estimate the current state of the system. A PID controller is used to generate control signals.
To minimize hazards during manufacturing and production processes of pyrotechnic compositions, semifinished and regular pyrotechnic articles, related properties of the pyrotechnic compositions must be determined and assessed with focus on those parameters that influence the exothermic reactions and explosion phenomena. Estimated impacts of these reactions as well as the sensitivities towards Initiation by thermal, mechanical or electrostatic stresses are relevant for this assessment.
Since the 50s of the last century so-called ‘Hazard Groups’(in German ‘Gefahrgruppen’) of pyrotechnic compositions were defined, to assess these properties which aim was to set appropriate safety measures for production purposes. This system of Hazard Groups is currently under review to determine if they are still relevant with the latest composition developments in this field and still represent the state of the art.
Several necessary changes and new approaches have already been identified. The new system will contain the following Hazard Groups, all with associated protection measures: 1.1 (and further sub-groups 1.1-1, 1.1-2 and 1.1-3), 1.2, 1.3 and 1.4. This structure is aligned to the international principles for the classification of such substances according to the TDG and GHS regulations. New or updated test and assessment criteria for these (sub-) groups are under development, and comprise of aspects such as sensitivity towards friction, impact, temperature and explosion effects.
This paper aims at giving an overview of this system of hazard Groups in Germany to optimize production safety including pyrotechnic compositions. An overview of this system is given along with example cases for testing and assessment, including a short differentiation of the energetic processes during the reactions.
During manufacturing and production processes of pyrotechnic compositions, semi-finished devices and regular pyrotechnic articles an inadvertent reaction or even explosion cannot be fully excluded. The optimization of the design of the involved single work processes can only reduce the risk of such a scenario. For doing so, one must consider the respective properties regarding thermal, mechanical, chemical and electrostatic sensitivities of the compositions being processed. One major key parameter in reducing the risks of such an event is to minimize the consequences, if the likelihood of this event cannot be further reduced.
Minimizing the consequences in cases of unintended explosions during production processes comprises of construction measures regarding buildings (different walls, orientation etc.), increasing safety distances to other buildings, and lowering the maximum net explosive masses and the number of people per room or production process.
Important criteria for defining and setting protection measures are the so-called ‘hazard groups’ (in German ‘Gefahrgruppen’), net explosive masses and the main impacts or hazards (such as blast pressure, heat/radiation and debris).
This paper aims at presenting some approaches used in Germany to minimize the impacts of possible reactions or inadvertent explosions during production processes of pyrotechnic compositions and articles in work spaces. This includes also the determination of safety distances and discussions on reducing thermal impacts.
Unter Passivität versteht man den Korrosionsschutz durch dünne, festhaftende Schichten aus Korrosionsprodukten. Für den schadensfreien Einsatz nichtrostender Stähle ergeben sich daraus zwei grundsätzliche Anforderungen.
Erstens muss sich die Passivschicht vollständig ausbilden können. Dabei sind die Oberflächenausführung,die mechanische Bearbeitung,die Elementverteilung, Ausscheidungen, die Wärmeeinbringung z.B. bei der schweißtechnischen Verarbeitung, Anlauffarben, sowie die chemische Nachbehandlung bzw. Konditionierung der Oberflächen von großer Bedeutung. Zweitens muss die Repassivierung von möglichen Defektstellen unter den Einsatzbedingungen möglich sein. Für das Repassivierungsvermögen sind die Legierungszusammensetzung, mögliche kritische Betriebszustände, prozessbedingte Besonderheiten wie etwa Stagnationsbedingungen und Reinigungsprozesse von Bedeutung.
This paper is intended to be the first study to discuss the fire suppressing performance of the four most common extinguishing media under the same reproducible conditions. The tests were performed in bench-scale and used standardized 5A wood cribs as well as a miniature extinguishing system with a liquid flow rate of 1.4 lmin−1. The tests results present a consistent overview of the fire suppression efficacies of water, water with a foaming agent, nozzle-aspirated foam and compressed air foam. Depending on their jet types, the cooling capabilities of the extinguishing media water and water with a foaming agent were compared to the cooling capability of a full Jet of wet, general and dry foams. The results show that compressed air foam suppressed fire most effectively under the test conditions. Because of the convoluted crib structure, water and water with foaming agents used from a distance are more effective in the form of a full jet rather than a spraying jet. At close range, spraying jets multiply their effectiveness. A slight difference can be observed in the cooling performance of extinguishing foams that use foaming agents from different manufacturers. The paper establishes a link between the foaming agent's cooling capability and its wetting power by relating the results of wood crib fire tests according to DIN EN 3–7 and findings from laboratory immersion tests compliant with DIN EN 1772.
This work focuses on the question if the bubble test prescribed in the Dangerous Goods Regulations has sufficient sensitivity to detect leakage rates, which could result in the formation of explosive atmospheres during transport. The sensitivity of the bubble test is not directly comparable with other leak testing methods because of its different flow conditions. Therefore, a normalized minimum detectable leakage rate under Helium test conditions is calculated for the bubble test. This sensitivity of the bubble test under reference conditions is compared with limit leakage rates for a worst‐case transport scenario. The sensitivity of the bubble test is not sufficient to prove the limit leakage rates for 6‐L packagings. The formation of explosive vapour‐air‐mixtures cannot be excluded. Therefore, more sensitive leak testing methods should be considered for smaller packaging design types.
Lifetime aspects including fatigue failure of concrete structures were traditionally only of minor importance. Because of the growing interest in maxing out the capacities of concrete, its fatigue failure under compression has become an issue. A variety of interacting phenomena such as e.g. loss of prestress, degradation due to chemical reactions or creep and shrinkage influence the fatigue resistance. Failure due to cyclic loads is generally not instantaneous, but characterized by a steady damage accumulation. Therefore, a reliable numerical model to predict the performance of concrete over its lifetime is required, which accurately captures order effects and full three-dimensional stress states.
Many constitutive models for concrete are currently available, which are applicable for specific loading regimes, different time scales and different resolution scales.
However, a key limitation of those models is that they generally do not address issues related to fatigue on a structural level. Very few models can be found in the literature that reproduce deterioration of concrete under repeated loading-unloading cycles. This is due to the computational effort necessary to explicitly resolve every cycle which exceeds the currently available computational resources. The limitation can only be overcome by the application of multiscale methods in time.
The objective of the paper is the development of numerical methods for the simulation of concrete under fatigue loading using temporal multiscale methods.
First, a continuum damage model for concrete is developed with a focus on fatigue under compressive stresses [1]. This includes the possibility to model stress redistributions and capture size effects. In contrast to cycle based approaches, where damage is accumulated based on the number of full stress cycles, a strain based approach is developed that can capture cyclic degradation under variable loading cycles including different amplitudes and loading frequencies. The model is designed to represent failure under static loading as a particular case of fatigue failure after a single loading cycle. As a consequence, most of the material parameters can be deduced from static tests. Only a limit set of additional constitutive parameters is required to accurately describe the evolution under fatigue loading. Another advantage of the proposed model is the possibility to directly incorporate other multi-physics effects such as creep and shrinkage or thermal loading on the constitutive level.
Second, a multiscale approach in time is presented to enable structural computations of fatigue failure with a reduced computational effort. The damage rate within the short time scale corresponding to a single cycle is computed based on a Fourier based approach [2]. This evolution equation is then solved on the long time scale using different implicit and explicit time integration schemes. Their performance and some limitations for specific loading regimes is discussed.
Finally, the developed methods will be validated and compared to experimental data.
[1] Vitaliy Kindrachuk, Marc Thiele, Jörg F. Unger. Constitutive modeling of creep-fatigue interaction for normal strength concrete under compression, International Journal of Fatigue, 78:81-94, 2015
[2] Vitaliy Kindrachuk, Jörg F. Unger. A Fourier transformation-based temporal integration scheme for viscoplastic solids subjected to fatigue deterioration, International Journal of Fatigue, 100:215-228, 2017
Lifetime aspects including fatigue failure of concrete structures were traditionally only of minor importance. Because of the growing interest in maxing out the capacities of concrete, its fatigue failure under compression has become an issue. A variety of interacting phenomena such as e.g. loss of prestress, degradation due to chemical reactions or creep and shrinkage influence the fatigue resistance. Failure due to cyclic loads is generally not instantaneous, but characterized by a steady damage accumulation. Therefore, a reliable numerical model to predict the performance of concrete over its lifetime is required, which accurately captures order effects and full three-dimensional stress states.
Many constitutive models for concrete are currently available, which are applicable for specific loading regimes, different time scales and different resolution scales.
However, a key limitation of those models is that they generally do not address issues related to fatigue on a structural level. Very few models can be found in the literature that reproduce deterioration of concrete under repeated loading-unloading cycles. This is due to the computational effort necessary to explicitly resolve every cycle which exceeds the currently available computational resources. The limitation can only be overcome by the application of multiscale methods in time.
The objective of the paper is the development of numerical methods for the simulation of concrete under fatigue loading using temporal multiscale methods.
First, a continuum damage model for concrete is developed with a focus on fatigue under compressive stresses. This includes the possibility to model stress redistributions and capture size effects. In contrast to cycle based approaches, where damage is accumulated based on the number of full stress cycles, a strain based approach is developed that can capture cyclic degradation under variable loading cycles including different amplitudes and loading frequencies. The model is designed to represent failure under static loading as a particular case of fatigue failure after a single loading cycle. As a consequence, most of the material parameters can be deduced from static tests. Only a limit set of additional constitutive parameters is required to accurately describe the evolution under fatigue loading. Another advantage of the proposed model is the possibility to directly incorporate other multi-physics effects such as creep and shrinkage or thermal loading on the constitutive level.
Second, a multiscale approach in time is presented to enable structural computations of fatigue failure with a reduced computational effort. The damage rate within the short time scale corresponding to a single cycle is computed based on a Fourier based approach. This evolution equation is then solved on the long time scale using different implicit and explicit time integration schemes. Their performance and some limitations for specific loading regimes is discussed.
Finally, the developed methods will be validated and compared to experimental data.
Die BAM ist nahezu über die gesamte Wertschöpfungskette hinweg wissenschaftlich tätig. Von der sicheren und effizienten Wasserstofferzeugung (POWER-to-GAS), über die (Zwischen-)Speicherung von Wasserstoff in Druckgasspeichern bis hin zum Transport bspw. mittels Trailerfahrzeug zum Endverbraucher.
Komplettiert werden die Aktivitäten der BAM durch die sicherheitstechnische Beurteilung von wasserstoffhaltigen Gasgemischen, die Verträglichkeitsbewertung von Werkstoffen bis hin zur Detektion von Wasserstoffkonzentrationen über geeignete Sensorik, auch mittels ferngesteuerter Messdrohnen (sog. UAV-Drohnen).
Zudem untersucht die BAM proaktiv Schadensrisiken und Unfallszenarien für die Sicherheitsbetrachtung, um mögliche Schwachstellen aufzeigen und potenzielle Gefährdungen erkennen zu können.
Bei Geräten und Maschinen zur bestimmungsgemäßen Verwendung in explosionsgefährdeten Bereichen muss in der europäischen Union eine Zündgefahrenbewertung durchgeführt werden. Dabei müssen unter anderem die Gefahren von nichtelektrischen Zündquellen betrachtet werden, zu denen auch die mechanischen Schlagvorgänge gehören. Bei Schlagvorgängen kommt es infolge des Zusammenstoßes zweier Werkstücke zu einer Umwandlung der kinetischen Energie. Dabei erhöht sich die Temperatur der Werkstoffe an der Kontaktstelle und es kommt unter Umständen zu einem Abtrennvorgang kleiner Partikel erhöhter Temperatur. Sowohl die heißen Kontaktstellen als auch die abgetrennten Partikel können eine wirksame Zündquelle für ein explosionsfähiges Gasgemisch darstellen. Zur Festlegung von Grenzwerten wurden in der Norm EN 13463-1:2009 die Gasgemische anhand ihrer Explosionsgruppe klassifiziert und zu jeder Gruppe die maximale Energie des Schlagvorgangs festgelegt, unter derer die Entstehung einer wirksamen Zündquelle als unwahrscheinlich angenommen werden kann.
Durch das alkalische Porenwassermilieu ist Stahl im Beton vor Korrosion geschützt. Unter ungünstigen Umgebungsbedingungen (Karbonatisierung, Chlorideintrag) kann die passive Deckschicht auf der Stahloberfläche zerstört werden. Im weiteren Verlauf können sich korrosionsbedingte Folgeschäden, wie Risse und Abplatzungen am Bauwerk ergeben. Um notwendige Sanierungsmaßnahmen sind frühzeitige und weitgehend zerstörungsfrei ermittelte Informationen über das aktuelle Korrosionsverhalten der Stahlbewehrung von großer Bedeutung. Die Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz.
Zur Bedarfsplanung von Feuerwehren in Städten in der Bundesrepublik Deutschland wurden im Jahr 1998 die Qualitätskriterien Hilfsfrist, Funktionsstärke und Erreichungsgrad für ein standardisiertes Schadensereignis erarbeitet. Das standardisierte Schadensereignis basiert auf Ergebnissen der O.R.B.I.T.-Studie aus dem Jahr 1978. Der dort dargestellte Rauchgas-temperaturverlauf für einen standardisierten Wohnungsbrand stellt Ergebnisse von Brandversuchen in einer Wohnung aus dem Jahr 1939 dar. Die zur Untersuchung herangezogenen Einrichtungsgegenstände bestanden dabei überwiegend aus cellulosehaltigen Materialien wie Holz und Papier. Die zunehmende Verwendung von Werkstoffen auf der Basis von Holz und Polymeren führt jedoch zu einer veränderten stofflichen Zusammensetzung von Einrichtungsgegenständen in Wohnungen. Im Rahmen der vorliegenden Dissertation wurde der Einfluss dieser veränderten stofflichen Zusammensetzung von gegenwärtigen Einrichtungsgegenständen auf den Verlauf von Raumbränden sowie auf die damit verbundene Stoff- und Energiefreisetzung während der Brandentstehungs- und Brandausbreitungsphase untersucht. Im Fokus der Untersuchung stand der Raum der Brandentstehung sowie ein angrenzender Raum.
Die Ergebnisse zeigen, dass gegenwärtige Einrichtungsgegenstände sowohl im Raum der Brandentstehung als auch in dem angrenzenden Raum zu höheren Rauchgastemperaturen und -konzentrationen führen. Grund hierfür sind neben den höheren Wärmefreisetzungsraten auch die höheren Stoffausbeuten der in den gegenwärtige Einrichtungsgegenständen verwendeten Materialzusammensetzungen. Vor diesem Hintergrund zeigt sich, dass sich die auf Basis der O.R.B.I.T.-Studie definierten Standards nicht mehr als Grundlage zur Bedarfsplanung von Feuerwehren eignen. Diese können mit Hilfe der vorliegenden Ergebnisse einer Prüfung unterzogen werden, um den veränderten Brandverläufen im Rahmen einer zukünftigen Bedarfsplanung gerecht zu werden.
This work examined the factors that influence the droplet corrosion of CO2 pipeline steels caused by oxyfuel flue gases in dense phase CO2 at 278 K, simulating the underground transport conditions. The wetting properties were studied by contact angle measurement, revealing pH and time dependency on the reactive wetting behaviors of carbon steel X70. Exposure tests with CO2 saturated water droplet on steel surface showed that the impurities (220 ppmv SO2 and 6700 ppmv O2) diffused into the droplet and then reacted with metal surfaces in dense phase condition, forming the corrosion products. The corrosion rate was confirmed strongly depending on the droplet volume as well as the SO2 concentration. Condensation experiments carried out on freshly polished coupons in CO2 with 200 ppmv H2O, 220 ppmv SO2 and 6700 ppmv O2, showed that the formation and aggregation of droplets is time and temperature dependent. At 278 K, condensation happened stronger and the corrosion products, mainly consisted of dense hydrated FeSO3/FeSO4. While at 288 K, more fluffy corrosion products consisting of iron oxide/hydroxide and hydrated FeSO3/FeSO4 were found. Further exposure tests on carbon steel coupons with different surface roughness did not reveal the difference in weight loss/gain and therefore the corrosion rate.
Recent studies have shown that even at a very low concentration of impurities (less than 100 ppmv of SO2, NO2, O2 and H2O) the droplet formation and condensation of sulfuric and nitric acids in dense phase CO2 are possible and observable. To reveal the mechanism of droplet corrosion in dense phase CO2 at high pressure and low temperature, further studies on factors that affect wettability and resulting corrosion behaviors of transport pipeline steels are needed. In this study, effects of surface morphology were investigated by varying surface roughness of carbon steel coupons exposed to CO2 stream containing impurities to measure the wettability by contact angle and to observe the condensation as well as possible droplet corrosion that followed. Other considered factors were: pH of the droplet, temperature, droplet volume, and exposure time.
Dieses Werk bietet Personen, die sich mit Gefahrgutlagerung beschäftigen einen Ansatz und ein Hilfsmittel für deren Arbeit.
Dieses Buch ist lediglich ein Nachdruck der Masterarbeit. Einer redaktionellen Überarbeitung, am besten mit Rückmeldungen von Anwendern, sieht der Rezensent mit Interesse entgegen.
Chemical companies must find new paths to successfully survive in a changing environment. The potential of digital technologies belongs to these. Flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short down-times between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds. Therefore, fully automated “chemical” process control along with real-time quality control are prerequisites to such concepts while being based on “chemical” information.
As an example, a fully automated NMR sensor is introduced, using a given pharmaceutical lithiation reaction as an example process within a modular pilot plant. Therefore, a commercially available benchtop NMR spectrometer was adapted to the full requirements of an automated chemical production environment such as, e.g., explosion safety, field communication, and robust evaluation of sensor data. It was thereof used for direct loop advanced process control and real-time optimization of the process. NMR appeared as preeminent online analytical tool and allowed using a modular data analysis tool, which even served as reliable reference method for further PAT applications.
A full integration and intelligent interconnection of such systems and processes progresses only hesitantly. The talk should encourage to re-think digitization of process industry based on smart sensors, actuators, and communication more comprehensively and informs about current technical perspectives such as the “one-network paradigm”, edge computing, or virtual machines. These give smart sensors, actuators, and communication a new perspective.
Alkali-activated fly ashes have been proposed for various applications where resistance against high temperatures is required, yet several details regarding the response of these materials to heat-exposure need to be clarified. In the present study, heat-induced cracking in fly ash-based alkali-activated pastes and lightweight mortars was analyzed by in-situ acoustic emission (AE) detection during complete heating-cooling cycles (up to ∼1100 °C), augmented by thermogravimetry and ex-situ SEM and XRD analyses. The applicability of the lightweight mortars as passive fire protection coatings was assessed by recording temperature-time curves of mortar-coated steel plates. Cracking during heating was limited and associated exclusively with the dehydration of the materials in the temperature range ∼90–360 °C. However, samples heated to temperatures above ∼600 °C exhibited intense cracking on cooling. This was attributed to differential deformations caused by local sintering and partial melting at the glass transition temperature, and subsequent quenching on cooling.
Two measurement campaigns of train-induced ground vibrations are evaluated for the vehicle-track-soil interaction. Ground vibrations, track vibrations and vehicle vibrations have been measured for train passages and impulse excitation and compared with theoretical results. The soil and the track-soil system are calculated by wavenumber integrals. The influence of the vehicle is introduced by a substructure method. By comparing theory and measurement the different components of excitation force and ground vibration can be analysed, the quasi-static excitation, track-alignment errors, the out-of-roundness of wheels, the wheel and rail roughness, and moreover, scattered axle impulses and ineffective high-frequency parts of the wheelset accelerations and forces.
Three measurement campaigns of train-induced ground vibrations are evaluated for the vehicle-track-soil interaction. Ground vibrations, track vibrations and vehicle vibrations have been measured for train passages and impulse excitation and compared with theoretical results. The soil and the track-soil system are calculated by wavenumber integrals. The influence of the vehicle is introduced by a substructure method. By comparing theory and measurement the different components of excitation force and ground vibration can be analysed, the quasi-static excitation, track-alignment errors, the out-of-roundness of wheels, the wheel and rail roughness, and moreover, scattered axle impulses and ineffective high-frequency parts of the wheelset accelerations and Forces.
Three measurement campaigns of train-induced ground vibrations are evaluated for the vehicle-track-soil interaction. Ground vibrations, track vibrations and vehicle vibrations have been measured for train passages and impulse excitation and compared with theoretical results. The soil and the track-soil system are calculated by wavenumber integrals. The influence of the vehicle is introduced by a substructure method. By comparing theory and measurement the different components of excitation force and ground vibration can be analysed, the quasi-static excitation, track-alignment errors, the out-of-roundness of wheels, the wheel and rail roughness, and moreover, scattered axle impulses and ineffective high-frequency parts of the wheelset accelerations and forces.
Explosionen in Rohrleitungen
(2019)
Deflagrationssicherungen sind Sicherheitseinrichtungen, die den Durchfluss von brennbaren Gasen und Dämpfen brennbarer Flüssigkeiten ermöglichen, den Flammendurchschlag und weitere Explosionsausbreitung nach der Zündung von explosionsfähigen Gas-/Dampf-Luftgemischen jedoch verhindern sollen.
Von besonderer Bedeutung für die Wirksamkeit der Deflagrationsrohrsicherung ist der Einbauort. Diesbezügliche Abweichungen von den normativen Anforderungen, die Grundlage der Prüfung und Zulassung von Deflagrationsrohrsicherungen sind, können zum Versagen der Sicherheitseinrichtung führen. Oft lassen sich allerdings aus betrieblichen bzw. verfahrenstechnischen Gründen der Norm entsprechende Einbaubedingungen nur schwer oder nicht realisieren.
Deshalb besteht das Ziel der Untersuchungen eines F&E-Vorhabens mit der Braunschweiger Flammenfilter GmbH darin, einen Beitrag zur Schaffung einer belastbaren Datenbasis zu leisten, um den Einfluss von Rohrleitungsverzweigungen auf deflagrative Gasexplosionen systematisch zu bewerten.
An experimental testing rig has been proposed to study the dynamic interaction between a liquid cargo and the carrying vehicle during turning maneuvers. The basic operational principle of the testing rig consists in simulating the lateral accelerations associated to turning maneuvers through the use of a tilt table.
While the experimental capabilities of the testing rig include the analysis of the effects of the cars on the whole transport infrastructure, including sleepers and ballast, a first use of the rig considered the effect of sloshing cargo on the level of dynamic forces transmitted to the rails. Such test was used to validate a simplified theoretical approach consisting of a two degree-of-freedom double pendulum mechanical system, where a simple pendulum, representing the sloshing cargo, is articulated to the spring-supported vehicle chassis, which is modelled as an inverted torsional pendulum. While the theoretical results exhibit a high correlation with the experimental data, the main discrepancy between both outputs, relates with the frequency of the residual vibration, once the lateral acceleration input is ceased. Such difference in frequency, would imply an underestimation of the number of loading cycles to which the infrastructure is subjected. On the other hand, the peak values are within acceptable difference levels.
Industrial fires and explosions initiating from self-ignition of combustible porous dust deposits represent a serious hazard for human beings, environment and industry. Understanding the fundamental basis of combustible dust ignition behaviours at different geometries is of importance to prevent and mitigate the accidental risks. A correlation of self-ignition temperatures (SITs) measured by hot-oven tests and minimum ignition temperatures of dust layers (MITLs) determined by hot-plate tests has been established previously. However, this analogy approach based on Frank-Kamenetzkii model is limited by ignoring the influence of oxygen diffusion. In this work, an improved method is developed by implementing a correction factor for the pre-exponential factor caused by the boundary geometry. This method is testified by comparing with experimental data, previous analogy method and numerical simulation. Results show that our proposed method performs a better predictability of MITLs and simplicity. The improved analogy method indicates that the different boundary geometries of a dust deposit significantly impact the apparent pre-exponential factor, while have an ignorable influence on the activation energy, which is also verified by numerical investigations. Furthermore, the numerical model with the corrected kinetic parameters provides a satisfactory explanation compared with experimental observations regarding to temperature and concentration evolutions of dust layers.
We compare four different sensing solutions suitable for distributed fiber optic humidity sensing in per uorinated graded-index polymer optical fibers (PFGI-POFs). Compared to silica fbers, polymer optical fibers over advantageous beneffits including signifficantly higher break down strain, fracture toughness and humidity sensitivity. Various humidity-related effects in PFGI-POFs have been reported in the last years including measured attenuation and length changes as well as Brillouin frequency and Bragg wavelength shifts. The four aforementioned methods could serve as a basis for distributed and quasi-distributed humidity sensing and are described here closely with an emphasis on plausible cross effects to temperature and strain. The main focus of this paper lies on the comparison of four approaches with regard to method complexity, sensitivity to humidity, spatial resolution, real-time capability and effort to compensate for cross effects.
This work investigates the fire phenomena of rigid polyurethane foams (RPUF) in detail. Rigid polyurethane foams (RPUF) are widely used in industry and daily life because of their outstanding mechanical and thermal insulating properties. In case of fire, cellular polymers like RPUF behave differently from bulk materials, the reason for this is their low thermal inertia. The aim of this study is to investigate the fire phenomena of RPUF in detail. Characterized by simultaneous physical and chemical processes which interact, depend, and compete with each other, the combustion of RPUF is a highly complex occurrence. Therefore it is necessary to study all aspects in detail. The fire phenomena that were examined are gasification, liquefaction, charring and structural integrity as well as collapse. The comprehensive understanding of the processes taking place during combustion is the foundation of customized development of successful flame retardant approaches. Advanced cone calorimeter investigations provide insight into the fire behavior under forced flaming conditions. Thermocouples in the inside of specimens give information about the temperature gradient and temperature of the pyrolysis zone during combustion. Changes in the morphology and thickness of the pyrolysis zone were examined using a hot-stage microscope, as well as SEM images of cross-sections of quenched foam specimens. Furthermore, fire phenomena were characterized using LOI and thermal analysis. By using a multimethodological approach and systematically varied sets of Polyurethane and Polyisocyanurate foams, new insights into the burning of RPUF were won. The detailed knowledge of fire phenomena is essential for future development of tailored flame retardant strategies for RPUF.
The reassessment of bridges is becoming increasingly important. The basic requirement for analyses of structural safety is reliable knowledge about individual structures. This paper introduces the new approach to evaluate the quality of measured data gained from non-destructive testing (NDT) to provide reliable, objective, and relevant information about existing bridges. The purpose is to relate this validated knowledge to probabilistic analyses. Bridging the gap between NDT and numerical reassessments indicates reduced numerical uncertainties and residual service time extensions. This paper deals with an application of this approach using measurement data collected by ultrasonic technique at a prestressed concrete bridge.
In this paper, we present an autonomous aerial robot to reconstruct tomographic 2D slices of gas plumes in outdoor environments. Our platform, the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS) combines a lightweight Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile octocopter. The TDLAS sensor provides integral gas concentration measurements but no information regarding the distance traveled by the laser diode's beam or the distribution of the gas along the optical path. We complemented the set-up with a laser rangefinder and apply principles of Computed Tomography (CT) to create a model of the spatial gas distribution from these integral concentration measurements. To allow for a rudimentary ground truth evaluation of the applied gas tomography algorithm, we set up a unique outdoor test environment based on two 3D ultrasonic anemometers and a distributed array of 10 infrared gas transmitters. We present first results showing the 2D plume reconstruction capabilities of the system under realistic conditions.
Die Brücken im Netz der Bundesverkehrswege sind überwiegend in einem ausreichenden bis guten Zustand. Allerdings steigt der Unterhalts- und Sanierungsaufwand aufgrund des inzwischen hohen Alters vieler Brücken sowie des ständig wachsenden Schwerlastverkehrs. Techniken zur Einschätzung der verbleibenden Lebensdauer von Brücken sowie zur dauerhaften Beobachtung des Tragverhaltens bzw. des Erfolges von Sanierungsmaßnahmen werden daher für den sicheren und wirtschaftlichen Betrieb dringend benötigt. Zur Evaluierung dafür geeigneter holistischer Ansätze wurde in der BAM das Projekt BLEIB - Bewertung, Lebensdauerprognose und Instandsetzung von Brückenbauwerken - ins Leben gerufen.
Ein zentrales Ergebnis des Projektes ist eine extern vorgespannte Stahlbetonbrücke als Zweifeldträger mit einer Gesamtlänge von 24 m, die für den Test verschiedenster Sensorsysteme, zur Validierung numerischer Modelle und zur Erprobung von Sanierungs- und Verstärkungsmaßnahmen entwickelt wurde. Für die Simulation unterschiedlicher Schädigungsgrade kann die Vorspannung der Brücke variiert werden. Die Brücke wird mit beweglichen Gewichten belastet und über einen Shaker zum Schwingen angeregt.
Das Brückenmodell wurde bewusst geschädigt, indem die Vorspannung der Struktur erstmalig schrittweise bis auf null reduziert wurde. Unter der Eigenlast verformte sich die Brücke, wodurch eine Rissbildung im Beton einsetzte. Die Zugspannung, die zuvor durch die Vorspannung aufgenommen wurde, übernahm Schritt für Schritt der Beton. Als die Zugspannungen die relativ geringe Zugfestigkeit des Betons überstiegen, begann dieser zu reißen und die schlaffe Bewehrung der Struktur nahm die Spannungen auf. Dieser Versuch wurde unter anderem von Schallemissionsmessungen begleitet. Der Rissbildungsprozess konnte damit, bei gleichzeitiger Aufzeichnung der Vorspannung, früh detektiert und die Risse geortet werden. Die Ergebnisse korrelieren gut mit den Ergebnissen der stereophotogrammetrischen Verformungsmessungen der Struktur.
Die Brücken im Netz der Bundesverkehrswege sind überwiegend in einem ausreichenden bis guten Zustand. Allerdings steigt der Unterhalts- und Sanierungsaufwand aufgrund des inzwischen hohen Alters vieler Brücken sowie des ständig wachsenden Schwerlastverkehrs. Techniken zur Einschätzung der verbleibenden Lebensdauer von Brücken sowie zur dauerhaften Beobachtung des Tragverhaltens bzw. des Erfolges von Sanierungsmaßnahmen werden daher für den sicheren und wirtschaftlichen Betrieb dringend benötigt. Zur Evaluierung dafür
geeigneter holistischer Ansätze wurde in der BAM das Projekt BLEIB - Bewertung, Lebensdauerprognose und Instandsetzung von Brückenbauwerken - ins Leben gerufen.
Ein zentrales Ergebnis des Projektes ist eine extern vorgespannte Stahlbetonbrücke als Zweifeldträger mit einer Gesamtlänge von 24 m, die für den Test verschiedenster Sensorsysteme, zur Validierung numerischer Modelle und zur Erprobung von Sanierungs- und Verstärkungsmaßnahmen entwickelt wurde. Für die Simulation unterschiedlicher Schädigungsgrade kann die Vorspannung der Brücke variiert werden. Die Brücke wird mit beweglichen Gewichten belastet und über einen Shaker zum Schwingen angeregt.
Das Brückenmodell wurde bewusst geschädigt, indem die Vorspannung der Struktur erstmalig schrittweise bis auf null reduziert wurde. Unter der Eigenlast verformte sich die Brücke, wodurch eine Rissbildung im Beton einsetzte. Die Zugspannung, die zuvor durch die Vorspannung aufgenommen wurde, übernahm Schritt für Schritt der Beton. Als die Zugspannungen die relativ geringe Zugfestigkeit des Betons überstiegen, begann dieser zu reißen und die schlaffe Bewehrung der Struktur nahm die Spannungen auf. Dieser Versuch wurde unter anderem von Schallemissionsmessungen begleitet. Der Rissbildungsprozess konnte damit, bei gleichzeitiger Aufzeichnung der Vorspannung, früh detektiert und die Risse geortet werden. Die Ergebnisse korrelieren gut mit den Ergebnissen der stereophotogrammetrischen Verformungsmessungen der Struktur.
We compare four different sensing solutions suitable for distributed fiber optic humidity sensing in per uorinated graded-index polymer optical fibers (PFGI-POFs). Compared to silica fbers, polymer optical fibers over advantageous beneffits including signifficantly higher break down strain, fracture toughness and humidity sensitivity. Various humidity-related effects in PFGI-POFs have been reported in the last years including measured attenuation and length changes as well as Brillouin frequency and Bragg wavelength shifts. The four aforementioned methods could serve as a basis for distributed and quasi-distributed humidity sensing and are described here closely with an emphasis on plausible cross effects to temperature and strain. The main focus of this paper lies on the comparison of four approaches with regard to method complexity, sensitivity to humidity, spatial resolution, real-time capability and effort to compensate for cross effects.
The reassessment of bridges is becoming increasingly important. The basic requirement for analyses of structural safety is reliable knowledge about individual structures. This paper introduces the new approach to evaluate the quality of measured data gained from non-destructive testing (NDT) to provide reliable, objective, and relevant information about existing bridges. The purpose is to relate this validated knowledge to probabilistic analyses. Bridging the gap between NDT and numerical reassessments indicates reduced numerical uncertainties and residual service time extensions. This paper deals with an application of this approach using measurement data collected by ultrasonic technique at a prestressed concrete bridge.
Kontinuierliche Sensorbasierte Bauwerksmessungen leisten einen wichtigen Beitrag zur Sicherheit von Verkehrsbauwerken. Hierzu werden im Vorhaben AISTEC Referenzbauwerke und Referenzverfahren untersucht mit Schwerpunkt auf den Einfluss klimatischer Bedingungen. Der Vortrag stellt den aktuellen Projektstand des FB 7.2 vor.
While today, engineers can choose from a wide range of rheology modifying admixtures, in some parts of the world, these are difficult to access, due to their complex processing. However, alternatives can be bio-based polymers such as polysaccharides from various sources. These are easily accessible all over the world, do not demand for complicated processing, and typically they are more sustainable than many established materials, which are crude oil-based.
The paper presents the effects of acacia gum, cassava starch and the gum of triumfetta pendrata A. Rich on the rheological performance of cementitious systems. It is shown that acacia gum can be as efficient as polycarboxylate based superplasticisers, cassava starch can reduce the yield stress slightly with little effect on the plastic viscosity, and the gum of triumfetta pendrata A. Rich increases the thixotropy of cement pastes with plasticizing polymers significantly.
In den internationalen Gefahrgutvorschriften ist vorgeschrieben, dass Säcke und flexible Großpackmittel (Flexible Intermediate Bulk Container – FIBC) staubdicht sein müssen. Eine quantitative Definition des Terminus Staubdichtheit, wie in anderen Technikgebieten üblich, ist jedoch nicht gegeben. Auch geeignete Prüfverfahren zum Nachweis der Staubdichtheit sind in den Vorschriften nicht genannt.
In der Praxis der stichpunkartigen Kontrollen von Gefahrguttransporten durch die Schwerlastgruppe der Autobahnpolizei Münster werden immer wieder Austritte von pulverförmigen oder körnigen Gefahrgütern aus eigentlich intakten Säcken und FIBC detektiert. Es wird ein Überblick über die im Jahr 2018 festgestellten Gefahrgutaustritte aus diesen Gefahrgutverpackungen sowie eine systematische Einordnung hinsichtlich betroffener Bauarten und möglicher Ursachen gegeben.
Bei der Stofffreisetzung aus intakten Gefahrgutverpackungen liegt ein mechanischer Transport von Partikeln durch Leckkanäle, z. B. im Verschluss-, Naht- oder Wandungsbereich, vor. Generell kommen zwei Freisetzungswege in Frage: Einerseits eine Langzeit-Freisetzung während des Transports, hervorgerufen durch eine kombinierte Wirkung von Stapellast des Füllguts und Transportvibrationen; andererseits eine stoßartige Freisetzung.
Auf Grundlage von durchgeführten Untersuchungen hinsichtlich der stoßartigen Freisetzung pulverförmiger Stoffe aus Gefahrgutsäcken werden erste Lösungsansätze hin zu einer Verbesserung der Staubdichtheit von Gefahrgutsäcken und -FIBC vorgestellt. Es wird ein Ausblick auf nachfolgende Arbeiten gegeben.
In earthquake-prone regions such as the Pacific Northwest, damage assessment tools are needed to enable safety evaluations to support recovery. Currently, damage assessment is performed primarily by visual inspection and is often impossible for structural members that are inaccessible, such as deep foundations or interior members hidden by cladding. This study explores the possibility of using embedded ultrasonic transducers to monitor reinforced concrete members for damage progression under earthquake loading. A novel methodology is proposed where changes in the member condition due to an increase in the earthquake-type loading of a full-scale column-foundation specimen are correlated with changes in the recorded ultrasonic waveforms. The discussed preliminary analysis of the ultrasonic signals is based on wave propagation velocity, changes in the coda wave portion, and maximum amplitude of the signals. Three embedded transducers were used to continuously monitor the laboratory specimen during destructive testing. This paper provides an overview of the proposed methodology, outlines the laboratory experiment, and discusses some preliminary observations.
In earthquake-prone regions such as the Pacific Northwest, damage assessment tools are needed to enable safety evaluations to support recovery. Currently, damage assessment is performed primarily by visual inspection and is often impossible for structural members that are inaccessible, such as deep foundations or interior members hidden by cladding. This study explores the possibility of using embedded ultrasonic transducers to monitor reinforced concrete members for damage progression under earthquake loading. A novel methodology is proposed where changes in the member condition due to an increase in the earthquake-type loading of a full-scale column-foundation specimen are correlated with changes in the recorded ultrasonic waveforms. The discussed preliminary analysis of the ultrasonic signals is based on wave propagation velocity, changes in the coda wave portion, and maximum amplitude of the signals. Three embedded transducers were used to continuously monitor the laboratory specimen during destructive testing. This paper provides an overview of the proposed methodology, outlines the laboratory experiment, and discusses some preliminary observations.
Ultrasonic transmission measurements are used to monitor concrete elements mostly on a laboratory scale since decades. Recently, coda wave interferometry, a technique adapted from seismology, has been introduced to civil engineering experiments. It can be used to reveal subtle changes in concrete samples and even large construction elements without having a transducer directly at the location where the change is taking place. The methodology works best with embedded transducers to avoid coupling issues or excessive environmental influence. These transducers can be used for newly built and existing structures. Recently, large concrete beams have been equipped with a network of transducers and loaded until failure. Using code wave interferometry, it was possible to visualize stress fields and damaged areas. This paper gives an overview of the state of the art, recent results achieved at BAM and a task list for further results and development.
Um ein tieferes Verständnis über die Schallemission bei der Entstehung und Ausbreitung von Rissen in Stahlrohrleitungen zu erlangen, wurde ein Stahlrohr der Güte S355J2H im Vierpunkt-Biegeversuch quasistatisch bis hin zum Wanddurchbruch (Leckage) belastet und mittels Schallemissionsmessung und Gleichstrompotentialmessung überwacht. Das Rohrsegment wurde durch einen 90°- Außenumfangskerb in der Mitte der Rohrlänge definiert vorgeschädigt, um davon ausgehend ein stabiles Risswachstum zu induzieren und die Analyse von Schallemission aus Rissereignissen, die am Kerb eintraten, sicherzustellen. Für die Schallemissionsmessung wurden vier Breitbandsensoren max. 105 mm vom Kerb entfernt montiert. Die Signalaufzeichnung erfolgte kontinuierlich und schwellwertunabhängig. Für die Gleichstrompotentialmessung wurde ein Gleichstrom von 300 A eingeleitet und der Potentialabfall über dem Kerb mit fünf Sonden entlang des Kerbs gemessen. Beide Messverfahren identifizieren die Rissinitiierung sowie Veränderungen im Risswachstum. Die detektierten Schallemissionsereignisse werden, unter Berücksichtigung spektraler Eigenschaften, mit fortschreitender Belastung und Rissentwicklung analysiert. Diese Studien wurden im Rahmen des interdisziplinären Forschungsprojekts AGIFAMOR, Aging infrastructure - Faseroptisches Monitoring von Rohrleitungen, an der BAM durchgeführt.
Composite-Druckbehälter werden für Speicherung und Transport von Gasen unter hohem Druck verwendet. Durch die gewichtssparende Struktur, die aus einem dünnwandigem Metallgefäß und Faserverbundwerkstoff-Ummantelung besteht, sind solche Behälter insbesondere für die Luftfahrt- und Automobilindustrie interessant, z.B. als Wasserstoffspeicher.
Die Druckprüfung ist ein konventioneller Test, um die Integrität von Metalldruckbehältern zu bewerten. Im Falle des Composite-Druckbehälters könnte eine solche Prüfung jedoch den Faserverbundwerkstoff überbeanspruchen und somit die verbleibende Lebensdauer der getesteten Komponente verringern. Infolgedessen ist es notwendig, Verfahren zur zerstörungsfreien Prüfung und möglicherweise zur Zustandsüberwachung von Composite-Druckbehältern zu entwickeln. Unser Ansatz verwendet geführte Ultraschallwellen und hat das Potenzial, kritische Schäden wie Risse im Metall und Faserbrüche und Matrixrisse in Faserverbundwerkstoff zu detektieren.
In diesem Beitrag wurde die Scaled Boundary Finite Elemente Methode benutzt, um die multimodale, geführte Wellenausbreitung in einem Mehrschichtverbund, der aus Metall und Kohlenfaserverbund entsteht, zu analysieren. Das Verfahren ermöglicht die Identifizierung geeigneter Wellenmoden und die Analyse ihrer Interaktion mit verschiedenen Schäden. Diese Kenntnisse sollen für die Entwicklung von Verfahren zur Zustandsüberwachung von Composite-Druckbehältern angewendet werden.
Ultrasonic transmission measurements are used to monitor concrete elements mostly on a laboratory scale since decades. Recently, coda wave interferometry, a technique adapted from seismology, has been introduced to civil engineering experiments. It can be used to reveal subtle changes in concrete samples and even large construction elements without having a transducer directly at the location where the change is taking place. The methodology works best with embedded transducers to avoid coupling issues or excessive environmental influence. These transducers can be used for newly built and existing structures. Recently, large concrete beams have been equipped with a network of transducers and loaded until failure. Using code wave interferometry, it was possible to visualize stress fields and damaged areas. This paper gives an overview of the state of the art, recent results achieved at BAM and a task list for further results and development.
In den internationalen Gefahrgutvorschriften ist vorgeschrieben, dass Säcke und flexible Großpackmittel (Flexible Intermediate Bulk Container – FIBC) staubdicht sein müssen. Eine quantitative Definition des Terminus Staubdichtheit, wie in anderen Technikgebieten üblich, ist jedoch nicht gegeben. Auch geeignete Prüfverfahren zum Nachweis der Staubdichtheit sind in den Vorschriften nicht genannt.
In der Praxis der stichpunkartigen Kontrollen von Gefahrguttransporten durch die Schwerlastgruppe der Autobahnpolizei Münster werden immer wieder Austritte von pulverförmigen oder körnigen Gefahrgütern aus eigentlich intakten Säcken und FIBC detektiert. Es wird ein Überblick über die im Jahr 2018 festgestellten Gefahrgutaustritte aus diesen Gefahrgutverpackungen sowie eine systematische Einordnung hinsichtlich betroffener Bauarten und möglicher Ursachen gegeben.
Bei der Stofffreisetzung aus intakten Gefahrgutverpackungen liegt ein mechanischer Transport von Partikeln durch Leckkanäle, z. B. im Verschluss-, Naht- oder Wandungsbereich, vor. Generell kommen zwei Freisetzungswege in Frage: Einerseits eine Langzeit-Freisetzung während des Transports, hervorgerufen durch eine kombinierte Wirkung von Stapellast des Füllguts und Transportvibrationen; andererseits eine stoßartige Freisetzung.
Auf Grundlage von durchgeführten Untersuchungen hinsichtlich der stoßartigen Freisetzung pulverförmiger Stoffe aus Gefahrgutsäcken werden erste Lösungsansätze hin zu einer Verbesserung der Staubdichtheit von Gefahrgutsäcken und -FIBC vorgestellt. Es wird ein Ausblick auf nachfolgende Arbeiten gegeben.
Um ein tieferes Verständnis über die Schallemission bei der Entstehung und Ausbreitung von Rissen in Stahlrohrleitungen zu erlangen, wurde ein Stahlrohr der Güte S355J2H im Vierpunkt-Biegeversuch quasistatisch bis hin zum Wanddurchbruch (Leckage) belastet und mittels Schallemissionsmessung und Gleichstrompotentialmessung überwacht. Das Rohrsegment wurde durch einen 90°- Außenumfangskerb in der Mitte der Rohrlänge definiert vorgeschädigt, um davon ausgehend ein stabiles Risswachstum zu induzieren und die Analyse von Schallemission aus Rissereignissen, die am Kerb eintraten, sicherzustellen. Für die Schallemissionsmessung wurden vier Breitbandsensoren max. 105 mm vom Kerb entfernt montiert. Die Signalaufzeichnung erfolgte kontinuierlich und schwellwertunabhängig. Für die Gleichstrompotentialmessung wurde ein Gleichstrom von 300 A eingeleitet und der Potentialabfall über dem Kerb mit fünf Sonden entlang des Kerbs gemessen. Beide Messverfahren identifizieren die Rissinitiierung sowie Veränderungen im Risswachstum. Die detektierten Schallemissionsereignisse werden, unter Berücksichtigung spektraler Eigenschaften, mit fortschreitender Belastung und Rissentwicklung analysiert. Diese Studien wurden im Rahmen des interdisziplinären Forschungsprojekts AGIFAMOR, Aging infrastructure - Faseroptisches Monitoring von Rohrleitungen, an der BAM durchgeführt.
While today, engineers can choose from a wide range of rheology modifying admixtures, in some parts of the world, these are difficult to access, due to their complex processing. However, alternatives can be bio‐based polymers such as polysaccharides from various sources. These are easily accessible all over the world, do not demand for complicated processing, and typically they are more sustainable than many established materials, which are crude oil‐based.
The paper presents the effects of acacia gum, cassava starch and the gum of triumfetta pendrata A. Rich on the rheological performance of cementitious systems. It is shown that acacia gum can be as efficient as polycarboxylate based superplasticisers, cassava starch can reduce the yield stress slightly with little effect on the plastic viscosity, and the gum of triumfet ta pendrata A. Rich increases the thixotropy of cement pastes with plasticizing polymers significantly.
Structural design and application have always been linked to the compressive strength of concrete as the main relevant criterion. This was justifiable in the past, where concrete consisted of water, ordinary Portland cement and aggregates, but this concept is no longer relevant for modern and more sustainable cement and concrete.
Despite these new developments, existing standards, guidelines and academic curricula have not been much updated and are still used worldwide. There is a need to change this situation by proper education of the users.
This overview describes the challenges that arise at a user Level from the higher complexity of modern concrete, and defines needs and requirements for enhanced applicability of sustainable concrete concepts.
Furthermore, recommendations are given on how better concrete practice can be communicated to all the involved parties, from civil and design engineers to constructors and site-appliers on the construction site.
We present, to our knowledge for the first time, a 100-km Brillouin Optical Frequency-Domain Analysis (BOFDA) employing a 200-km fiber loop. Compared to our previous publication, enhanced sensor length, sensor accuracy and spatial resolution are presented. The performance improvements are achieved by applying distributed Raman amplification (DRA) and a digital high-pass filter. We report on temperature measurements over sensing distances of 75 km and 100 km both with a 12.5-m spatial resolution. Temperature changes of 5 °C have been measured along 75 km sensing fiber. A temperature change of 30 °C has been detected at 99.5 km.
This presentation deals with the phenomenology and design of pile foundations for offshore wind turbines, and is divided into two lectures.
The first lecture presents a brief introduction to the context and peculiarities of such foundations, and then focuses on the particular case of axially loaded piles. This part is most relevant for the relatively slender piles of the multi-pile substructures (i.e. jackets and tripods). A clear distinction between physical phenomenology and practical design is drawn here.
The second lecture continues with the case of lateraly loaded offshore piles, which bears most relevance for the case of the monopile foundations. Here again, a clear separation between physical reality and design methods is intended.
Finally, the last part of the second lecture introduces several advanced topics which lie outside the classical design approaches, namely the hydromechanical coupling effects (i.e. the excess pore-pressure generation around the monopiles), the cyclic pile fatigue and the so-called pile Setup (i.e. the time effects on the axial pile capacity). The relevance of the latter two topics is illustrated with experimental results from a field testing campaign on real large-scale piles.
Corrosion of steel reinforcement in concrete is one of the major deterioration mechanisms limiting the service life of reinforced concrete structures. While for conventional (Portland cement-based) concretes a great amount of experience exists in this regard, the factors that determine the onset of reinforcement corrosion in alkali-activated materials are incompletely understood yet.
One aspect of corrosion protection is leaching and the accompanying changes of the concrete pore solution. In the present study, alkali-activated fly ash mortars with embedded carbon steel rebars were exposed to de-ionised water for periods up to 330 days, and the electrochemical response of the steel (free corrosion potential, polarisation resistance), the alteration of the mortar (ohmic resistance, mechanical strength, pore size distribution) as well as the pore solu¬tion composition were monitored.
Although substantial alkali leaching was observed, the pH of the pore solution remained at values sufficient to protect the embedded steel from depassivation. The mortar did not exhibit indications of significant deterioration. Thus, the present results suggest that leaching is not critical for pro¬tec¬tion of steel reinforcement in alkali-activated fly ash mortars and concretes.
Mortars for application on concrete, e.g. repair mortars or protective coatings, need to have a durable bond to the substrate. This bond is determined by the adhesion between the two materials and by the differential deformations of the mortar and the substrate. In the present contribution, the hygric deformations (shrinkage/expansion) of novel one-part alkali-activated mortars and their bond to concrete substrates are studied. Shrinkage of the mortars was studied at 50 % r.H., while expansion was studied on mortars stored over an open water surface (> 99% r.H.). The bond behaviour was studied by pull-off tests according to DIN EN 1542 and by optical microscopy.
The alkali-activated mortars exhibit hygric deformations much lower than the deformations of an established, commercial mortar for sewer maintenance that was tested as reference in parallel with the alkali-activated mortars. The bond behaviour of the alkali-activated mortars depends strongly on their mix-design and curing. Optical microscopy showed that in the mortars with lower bond strength, cracks developed in the mortar during curing. Mortars with appropriate mix-design and curing did not exhibit cracking, and their pull-off strength (up to > 3 MPa) conformed to the requirements of relevant standards.
The production of Portland cement causes a substantial environmental impact, since the calcination of limestone results in high emissions of carbon dioxide. The use of supplementary cementitious materials such as calcined clays as partial replacement for Portland cement offers a solution to limit this environmental impact. This paper investigates four clays from deposits in central Germany with the aim of obtaining pozzolans for the production of Portland-pozzolana cement. The results obtained show that the calcined clays possess pozzolanic proper¬ties, which differ depending on calcination temperature and the relative amounts of kaolinite and 2:1 clay minerals.
Dieses erste Memorandum zur Lehre und Forschung an deutschsprachigen Hochschulen auf dem Gebiet der zerstörungsfreien Prüfung im Bauwesen gibt einen Überblick hinsichtlich der akademischen Ausbildung und zeigt mögliche Schwerpunkte vor allem in der Lehre auf. Diese Schwerpunkte berücksichtigen auch aktuelle Entwicklungen und Themen auf dem Gebiet der Forschung. Es werden Anregungen zur Entwicklung bzw. Weiterentwicklung der Lehr-Curricula im Hinblick auf eine umfassende und solide fachliche Ausbildung der Studierenden des Bauwesens und angrenzender Fachrichtungen gegeben. Inhaltlich und formal lehnt sich der Beitrag an dem Memorandum der Hochschullehrer im Fachgebiet „Werkstoffe im Bauwesen“ (Breit et al., 2012) an und beruht auf einer Initiative des Unterausschusses Ausbildung – Arbeitsgruppe Ausbildung in der Hochschule – des Fachausschusses ZfP im Bauwesen der Deutschen Gesellschaft für zerstörungsfreie Prüfung (DGZfP). Die Hauptredaktion wurde übernommen von Prof. Christian U. Grosse (TU München) und Prof. Ralf W. Arndt (FH Erfurt).
This study aims at investigating the use of coal fly ash-based alkali activated mortars as passive fire protection system for steel structures. These systems are used to slow down the temperature rise of the steel substrate in case of fire. In addition, the protective system should guarantee the ability to prevent and/or mitigate steel corrosion phenomena. The behavior of a light-weight mortar was compared to that of a normal-weight mortar. Density and porosity were measured to better characterize the physical properties of the mortars. The degree of protection in case of fire was assessed by performing medium-scale fire tests. Acoustic emission measurements were conducted to analyze cracking phenomena during the high temperature exposure. The corrosion process was evaluated using an electrochemical approach in order to monitor the durability of the developed material. Preliminary results show that a 20 mm-thick layer of light-weight mortar is able to protect the steel substrate from reaching the critical temperature of 500 °C for 38 minutes in case of cellulosic fire. In addition, alkali activated mortars provide protection for carbon steel in presence of aggressive environment (i.e. presence of chlorides). The corrosion resistance is strictly related to the physical properties of the developed mortars.