Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 55 von 20001
Zurück zur Trefferliste

Investigation of intracorporeal shock wave propagation using a simplified torso model and a shock wave generator –a progress report

  • Following directly from the information presented at IFBIC 2023 on the research project 'Investigation of intracorporeal shock wave propagation using a simplified torso model and a shock wave generator', the latest results are presented below [1]. In order to contribute to the research efforts on the primary explosion effects, the aim of the investigation is the development of a multidisciplinary method to investigate shock wave behavior in various generic tissue simulants under the most reproducible conditions possible with realistic loads in an experimental series with short set-up times. To achieve this, an autoclave with a volume of 0.065 m3 is used to generate reproducible pressure waves (Fig. 1). The autoclave will be referred to as Shockwave Generator (SWG). The pressure wave is produced by the detonation of a stoichiometric mixture of acetylene and oxygen under atmospheric conditions. The SWG-outlet is sealed by a rupture disc, which can be adjusted in thickness to vary theFollowing directly from the information presented at IFBIC 2023 on the research project 'Investigation of intracorporeal shock wave propagation using a simplified torso model and a shock wave generator', the latest results are presented below [1]. In order to contribute to the research efforts on the primary explosion effects, the aim of the investigation is the development of a multidisciplinary method to investigate shock wave behavior in various generic tissue simulants under the most reproducible conditions possible with realistic loads in an experimental series with short set-up times. To achieve this, an autoclave with a volume of 0.065 m3 is used to generate reproducible pressure waves (Fig. 1). The autoclave will be referred to as Shockwave Generator (SWG). The pressure wave is produced by the detonation of a stoichiometric mixture of acetylene and oxygen under atmospheric conditions. The SWG-outlet is sealed by a rupture disc, which can be adjusted in thickness to vary the initial pressure. Additionally, modifying the composition of the acetylene-oxygen mixture can result in different load cases. The SWG requires approximately 30 minutes of set-up time between trials. The SWG was adjusted to match the characteristics of a real and typical explosive through free-field measurements. The experiments demonstrated that the pressure wave propagates in a hemispherical shape and has sufficient reproducibility. To represent soft tissue, a basic model made of homogeneous ballistic gelatin is used in a geometrically simplified torso model (STM) (Fig. 2). The STM was enlarged to outer dimensions of 400 x 250 x 240 mm. Viscoelastic behavior of the ballistic gelatin can be assumed due to the collagen structure [2]. The density of the ballistic gelatin, and therefore the sound velocity, can be adjusted by changing the mixing ratio. Simplified simulants, such as hollow and solid material (bone simulant), were embedded in the STM. Additionally, the STM has been tested as a carrier material for biological substances, such as indicator species. The next step is to test the STM as a carrier material for larger organic tissue structures such as lungs or kidneys. The organic tissue samples will undergo histological examination to analyze their structural changes afterwards. The STM is equipped with embedded piezoelectric pressure sensors, an accelerometer and a temperature sensor. Visual documentation is captured using a high-speed camera. This measurement setup allows for the tracking of the coupled pressure wave and its behavior within the model and at the media transitions. Pressure values can be recorded after certain media changes, such as from soft tissue to a solid material (Figure 3). The following is a review of the optimizations made to the entire experimental setup. The reproducibility of the SWG was increased. This was achieved by extending the evacuation process to the entire feed system of the SWG. Nitrogen residues in the SWG system can thus be avoided. As a result, the double peaks that occur at the first maximum can be avoided, as combustion runs more evenly without the nitrogen residues. In addition, partially varying peak overpressures can be avoided, as the acytelene-oxygen mixture is not too lean due to the elimination of the nitrogen residues. The workflow has been streamlined, resulting in an average set-up time of 25 minutes for the SWG. In the case of the STM, the manufacturing process in particular was optimized by examining and defining the manufacturing process based on scientific publications, which increases the reproducibility of the STM base bodies. As already mentioned in the previous paragraph, the STM was equipped with various additives in order to investigate the transition behavior of the pressure wave. The following trail serves as an example: A comparison is made between the STM in the basic structure (Fig. 2 l.s.) and with an embedded solid material (bone plate) (Fig. 3 l.s.). An external overpressure of 100 kPa is generated by the SWG at a distance of 1 m, where the STM is placed. For the basic STM structure, the sensor distance is consistently 100 mm. The internal overpressure is visible in Fig. 2 r.s.. A typical ideal pressure curve can be seen. The characteristic points are easily distinguishable from the reflection peaks. In the STM with an embedded solid material, the sensor distance remains consistently at 66.6 mmzeige mehrzeige weniger

Volltext Dateien herunterladen

  • IFBIC2024_See.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Henrik Seeber
Koautor*innen:Steffen Grobert, Daniel Krentel
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2024
Organisationseinheit der BAM:2 Prozess- und Anlagensicherheit
2 Prozess- und Anlagensicherheit / 2.1 Sicherheit von Energieträgern
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:Primäre Explosionswirkung
Blast injury; Experimental setup; Shock wave generator
Themenfelder/Aktivitätsfelder der BAM:Infrastruktur
Infrastruktur / Security
Veranstaltung:8th International Forum on Blast Injury Countermeasures
Veranstaltungsort:Washington D.C., USA
Beginndatum der Veranstaltung:01.05.2024
Enddatum der Veranstaltung:03.052024
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:22.05.2024
Referierte Publikation:Nein
Eingeladener Vortrag:Nein