Response Time Measurement of Hydrogen Sensors
- The efficiency of gas sensor application for facilitating the safe use of hydrogen depends considerably on the sensor response to a change in hydrogen concentration. Therefore, the response time has been measured for five different-type commercially available hydrogen sensors. Experiments showed that all these sensors surpass the ISO 26142 standard; for the response times t90 values of 2 s to 16 s were estimated. Results can be fitted with an exponential or sigmoidal function. It can be demonstrated that the results on transient behaviour depend on both the operating parameters of sensors and Investigation methods, as well as on the experimental conditions: gas change rate and concentration jump.
Autor*innen: | Thomas Hübert, J. Majewski, Ulrich Banach, Marc Detjens, Carlo Tiebe |
---|---|
Dokumenttyp: | Beitrag zu einem Tagungsband |
Veröffentlichungsform: | Graue Literatur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Proceedings of 7th International Conference on Hydrogen Safety (ICHS 2017) |
Jahr der Erstveröffentlichung: | 2017 |
Erste Seite: | 1251 |
Letzte Seite: | 1261 |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Freie Schlagwörter: | Hydrogen sensor; Response time; Test facility; t90 value |
Veranstaltung: | 7th International Conference on Hydrogen Safety (ICHS 2017) |
Veranstaltungsort: | Hamburg, Germany |
Beginndatum der Veranstaltung: | 11.09.2017 |
Enddatum der Veranstaltung: | 13.09.2017 |
ISBN: | 978-88-902391 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 21.03.2019 |
Referierte Publikation: | Nein |