• Treffer 10 von 30
Zurück zur Trefferliste
Zitieren Sie bitte immer diesen URN: urn:nbn:de:kobv:b43-950

Experimental investigation and CFD simulation of organic peroxide pool fires (TBPB and TBPEH)

  • Time averaged mass burning rate (m˙′′f ), flame length (H), temperature (T ), irradi- ance (E) and surface emissive power (SEP ) of TBPB (tert -butyl peroxybenzoate) and TBPEH (tert-butyl peroxy-2-ethylhexanoate) pool fires are measured for six pool di- ameters (d = 0.059 m, 0.107 m, 0.18 m, 0.5 m, 1 m and 3.4 m) at BAM in house and outside test facility. The measured heats of combustion (–Δhc) of TBPB and TBPEH are 30113 kJ/kg and 34455 kJ/kg and the specific heat capacities at constant pressure (cp) are 1.8 kJ/(kg K) and 2.1 kJ/(kg K) respectively. The measured m˙′′f of TBPB and TBPEH pool fires are in the range of 0.37 kg/(m2 s)≤ m˙ ′′ f ≤ 0.83 kg/(m2 s) and show little dependence on the pool diameter d, and are four to sixty times higher (for d = 1 m) than that of hydrocarbon pool fires. It is shown that the mass burning rates of the investigated organic peroxides can be represented as an exponential function of the self-accelerating decomposition temperature (SADT). Low SADT impliesTime averaged mass burning rate (m˙′′f ), flame length (H), temperature (T ), irradi- ance (E) and surface emissive power (SEP ) of TBPB (tert -butyl peroxybenzoate) and TBPEH (tert-butyl peroxy-2-ethylhexanoate) pool fires are measured for six pool di- ameters (d = 0.059 m, 0.107 m, 0.18 m, 0.5 m, 1 m and 3.4 m) at BAM in house and outside test facility. The measured heats of combustion (–Δhc) of TBPB and TBPEH are 30113 kJ/kg and 34455 kJ/kg and the specific heat capacities at constant pressure (cp) are 1.8 kJ/(kg K) and 2.1 kJ/(kg K) respectively. The measured m˙′′f of TBPB and TBPEH pool fires are in the range of 0.37 kg/(m2 s)≤ m˙ ′′ f ≤ 0.83 kg/(m2 s) and show little dependence on the pool diameter d, and are four to sixty times higher (for d = 1 m) than that of hydrocarbon pool fires. It is shown that the mass burning rates of the investigated organic peroxides can be represented as an exponential function of the self-accelerating decomposition temperature (SADT). Low SADT implies that the organic peroxide pool fires burn at a much higher m˙′′f than hydrocarbon pool fires. Fuel Froude numbers (Frf) of TBPB and TBPEH are 5 to 100 times (depending on d) higher than for hydrocarbon pool fires. Due to higher Frf the H of TBPB and TBPEH (measured with a S-VHS Videocamera) are found to be two times larger (d = 1 m) than corresponding pool fires of hydrocarbons. Heskestads flame length correlation predicts the Hd (d = 3.4 m) of TBPB and TBPEH pool fires much better than Thomas and Fay correlations. The measured time averaged flame temperatures T (d = 3.4 m) for TBPB and TBPEH pool fires are in the range of 1400 K ≤ T ≤ 1500 K and are 200 K to 300 K higher than for JP-4, kerosene and gasoline. The irradiances of the TBPB and TBPEH pool fires measured by radiometers are E (Δy/d = 0.3) = 45 kW/m2 and E = 98 kW/m2 which are two to ten times higher in comparison to the corresponding n-pentane, super gasoline and diesel pool fires. So the thermal safety distances for organic peroxide pool fires are larger by a factor four in comparison to the hydrocarbon pool fires. An infrared thermography system is used for the determination of SEP of TBPB and TBPEH pool fires. The values of surface emissive power for TBPB and TBPEH are SEP (d = 3.4 m) = 196 kW/m2 and SEP = 258 kW/m2 and thus the SEP are by a factor of approximately two higher than for hydrocarbon pool fires. A self-sustained pulsating Hd (’W’-Effect) is found in TBPB pool flames and is further analysed to explain the reason of occurance on the basis of chemical structure of the fuel and discontinuous heat flux back from flame to the liquid pool. CFD simulations of TBPB and TBPEH pool fires at d = 0.18 m, 0.5 m, 1 m, 3.4 m and 8 m are carried out using the Unsteady Reynolds Averaged Navier Stokes (URANS) equa- tions. The three-dimensional geometries have been discritized with unstructured hybrid grids, with the number of cells in the range of 1 million. Depending on the grid resolu- tion and the pool diameter time steps of 0.0001 s ≤ Δt ≤ 0.01 s for the CFD simulations are used. For solving the discritized equations a finite volume based implicit solver AN- SYS CFX has been used. For modelling the combustion, stoichiometric combustion for both peroxides are assumed. The temperature dependence of the reaction rate has been determined by the Arrhenius approach. For modelling the combustion eddy dissipation concept (EDC) model has been used. For turbulence buoyancy modified k- � and SAS (Scale Adaptive Simulation) turbulence models are used. For the thermal radiation and soot mass fraction discrete transfer radiation model and Magnusson soot model have been used. A new method is suggested for the prediction of mass burning rate (m˙′′f ) by CFD simula- tion. Both peroxide pool fires show approximately constant mass burning rate indepen- dent of d whereas m˙′′f of TBPEH are under predicted at the beginning but show relatively good agreement with measurements for large pool diameters (d = 1 m). In case of TBPB the CFD simulation over predicts the mass burning rate m˙′′f of small TBPB pool fires and shows a continuous decrease with d. CFD predicts the flame length H close to the measured data provided that the constants in Thomas equation are modified. The CFD predicted time averaged surface emission flame temperatures of TBPB and TBPEH pool fires (d = 3.4 m, 1437 K and 1542 K) are in good agreement with the measured time averaged flame temperatures. The CFD predicted SEP for TBPB and TBPEH pool fires (d = 3.4 m, 217 kW/m2 and 288 kW/m2) are also in agreement with the measured values. From the CFD predicted irradiance ECFD it is possible to determine the thermal safety distances from large pool fires of hydrocarbons and organic peroxides.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Kirti Bhushan Mishra
Dokumenttyp:Dissertation
Veröffentlichungsform:Eigenverlag BAM
Schriftenreihe (Bandnummer):BAM Dissertationsreihe (63)
Sprache:Englisch
Jahr der Erstveröffentlichung:2010
Veröffentlichende Institution:Bundesanstalt für Materialforschung und -prüfung (BAM)
Titel verleihende Institution:Universität Duisburg-Essen, Fakultät für Ingenieurwissenschaften, Abteilung Maschinenbau und Verfahrenstechnik
Gutachter*innen:Christof Schulz, Axel Schönbucher
Datum der Abschlussprüfung:12.05.2010
Verlag:Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlagsort:Berlin
Jahrgang/Band:63
Erste Seite:1
Letzte Seite:150
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Freie Schlagwörter:CFD simulation; Pool fires; organic peroxides flame characteristics; safety distance
URN:urn:nbn:de:kobv:b43-950
ISSN:1613-4249
ISBN:978-3-9813550-6-2
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoAllgemeines Deutsches Urheberrecht
Datum der Freischaltung:23.01.2015