Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (109)
- Vortrag (75)
- Posterpräsentation (23)
- Sonstiges (14)
- Beitrag zu einem Sammelband (10)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (1)
- Preprint (1)
- Forschungsbericht (1)
Schlagworte
- Synchrotron (52)
- XRF (45)
- BAMline (42)
- Gold (30)
- XANES (12)
- Synchrotron radiation (11)
- Archaeometry (9)
- BESSY (8)
- X-ray fluorescence (8)
- Machine learning (7)
Organisationseinheit der BAM
- 6 Materialchemie (55)
- 6.3 Strukturanalytik (55)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 8 Zerstörungsfreie Prüfung (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 5 Werkstofftechnik (1)
- 5.0 Abteilungsleitung und andere (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 6.0 Abteilungsleitung und andere (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.5 Röntgenbildgebung (1)
- 9 Komponentensicherheit (1)
- 9.2 Versuchsanlagen und Prüftechnik (1)
- P Präsident (1)
- P.0 Präsident und andere (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (75)
The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications.
New analyses of a series of very rare silverpoint drawings that were executed by Rembrandt Harmensz. van Rijn (16061669) which are kept today in the Kupferstichkabinett (Museum of Prints and Drawings) of the State Museums of Berlin are reported here. Analysis of these drawings requires particular attention because the study has to be fully non-destructive and extremely sensitive. The metal alloy on the paper does not exceed some hundreds of µg/cm². Therefore, synchrotron radiation induced X-ray fluorescence (SR-XRF) is together with external micro-proton-induced X-ray emission the only well-suited method for the analyses of metalpoint drawings. In some primary work, about 25 German and Flemish metalpoint drawings were investigated using spatially resolved SR-XRF analysis at the BAMline at BESSY. This study enlarges the existing FrenchGerman database of metalpoint drawings dating from the 15th and 16th centuries, as these Rembrandt drawings originate from the 17th century where this graphical technique was even rarer and already obsolete. It also illustrates how SR-XRF analysis can reinforce art historical assumptions on the dating of drawings and their connection.
A layer of Sb atoms, implanted with an energy of 400 keV and a nominal dose of 5×1016 atoms/cm2 into a high purity silicon wafer, was certified for its areal density (atoms/cm2) using Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA) and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) and for its isotope ratio using INAA and ICP-IDMS. Excellent agreement between the results of the different independent methods was found. In the present work, the measurements of the homogeneity of the areal density of Sb, previously determined with RBS in spots having 1 mm diameter, are improved with synchrotron X-ray fluorescence analysis: Higher precision in even smaller sample spots allows to estimate a reduced inhomogeneity of the whole batch of samples of the order of only 0.4%. Thus the uncertainty of the certified value can further be reduced. Down to fractions of a chip with 0.3×0.4 mm2 area, the areal density is now certified as (4.81±0.06)×1016 Sb atoms/cm2, where the expanded uncertainty 0.06 (coverage factor k=2) corresponds to only 1.2%. The relative merits of the different analytical methods are discussed.
Electron probe microanalysis (EPMA) measurement of thin-film thickness in the nanometre range
(2002)
The thickness of thin films of platinum and nickel on fused silica and silicon substrates has been determined by EPMA using the commercial software STRATAGEM for calculation of film thickness. Film thickness ranged in the order 10 nm. An attempt was made to estimate the confidence range of the method by comparison with results from other methods of analysis. The data show that in addition to the uncertainty of the spectral intensity measurement and the complicated fitting routine, systematic deviation caused by the underlying model should be added. The scattering in the results from other methods does not enable specification of a range of uncertainty, but deviations from the real thickness are estimated to be less than 20%.
Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA.
Four hundred sixteen silver coins stemming from the Ottoman Empire (16th and 17th centuries) were analyzed in order to confirm the fineness of the coinage as well as to study the provenance of the alloy used for the coins. As most of the coins showed the typical green patina on their surfaces due to corrosion processes which have led to the depletion of copper in the near-surface domains of the silver coins in comparison to their core composition, small samples by cutting splinters from the coins had to be taken, embedded in synthetic resin and cross-sectioned in order to investigate the true-heart metal composition. The type of the alloy was investigated as well as if coins minted in different locations demonstrated homogeneous traits concerning the predominant impurities which could suggest a common ore. Several X-ray based techniques (µ-XRF, µ-SRXRF and µ-PIXE) could be applied in order to determine the silver contents as well as the minor and trace elements. Finally, SEM/EDX was applied in order to study the homogeneity/heterogeneity of the coins and the presence of surface enrichments. In general, the silver content of the analyzed specimen varies between 90% and 95%. These outcomes have not supported the historical interpretations, which predict that during the period studied a debasement of approximately 44% of the silver content of the coins should have occurred.
Trace-elements are more significant for provenancing archaeological metallic artifacts than the main components. For gold, the most promising elements are platinum group elements (PGE), Sn, Te, Sb, Hg and Pb. Several small fragments of natural Transylvanian gold placer and primary were studied by using micro-PIXE technique at the Legnaro National Laboratory AN2000 microbeam facility, Italy and at the AGLAE accelerator, C2RMF, Paris, France and by using micro synchrotron radiation X-ray fluorescence (micro-SR-XRF) at BESSY synchrotron, Berlin, Germany. The goal of the study was to identify the trace-elements, especially Sn, Sb and Te. A spectacular application to five Dacian gold bracelets authentication is presented (Sn and Sb traces).
Trace elements of ancient gold such as Pt, give fundamental information on the circulation of the metal in the past. In the case of objects from the cultural heritage, the determination of trace elements requires non-destructive point analysis in general. These conditions and the need of good detection limits restrain the number of applicable analytical techniques.
After the development of a PIXE set-up with a selective Cu or Zn filter of 75 µm and of a PIXE-XRF set-up using a primary target of As, we tested the possibilities of spatially resolved Sy-XRF to determine Pt in gold alloys. With a Zn filter, PIXE showed a detection limit of 1000 ppm in gold while PIXE-XRF lowers this detection limit down to 80 ppm. This last value being constrained by the resonant Raman effect produced on gold. In order to improve the detection limit of Pt keeping the non-destructiveness and access to point analysis, we developed an analytical protocol for XRF with synchrotron radiation at BESSY II, using the BAMline set-up. The L-lines of Pt were excited by a beam of energy above and below 11.564 keV and measured using a Si(Li) detector with a 50 µm Cu filter. A µ-beam of 100250 µm2 was used according to the size of the sample. The determination of the Pt content in the samples was carried out by Monte-Carlo simulation and subtraction of Au and Pt spectra obtained on pure standards. The limit of detection for Pt of 20 ppm was determined by using certified standards. The detection limits of a small set of other characteristic elements of gold were also measured using an incident energy of 33 keV.
Slicing - A New Method For Non Destructive 3D Elemental Sensitive Characterization Of Materials
(2013)
ML@BAMLINE
(2021)
A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ–2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 mm is achieved.
Fingerprinting ancient gold work requires the use of nondestructive techniques with high spatial resolution (down to 25 µm) and good detection limits (micrograms per gram level). In this work experimental setups and protocols for synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline of the Berlin electron storage ring company for synchrotron radiation (BESSY) in Berlin for the measurement of characteristic trace elements of gold are compared considering the difficulties, shown in previous works, connected to the quantification of Pt. The best experimental conditions and calculation methods were achieved by using an excitation energy of 11.58 keV, a silicon drift chamber detector (SDD) detector, and pure element reference standards. A detection limit of 3 µg/g has been reached. This newly developed method was successfully applied to provenancing the Xiongnu gold from the Gol Mod necropolis, excavated under the aegis of the United Nations Educational, Scientific and Cultural Organization (UNESCO). The composition of the base alloys and the presence of Pt and Sn showed that, contrary to what is expected, the gold foils from the first powerful empire of the steppes along the Great Wall were produced with alluvial gold from local placer deposits located in Zaamar, Boroo, and in the Selenga River.
A set of ten calibration materials based on acrylonitrile-butadiene-styrene terpolymer (ABS) containing the elements Br, Pb, Cd, Cr, and Hg was produced in order to control polymer samples in regard to the restriction on the use of certain hazardous substances (RoHS) directive. The materials were produced with respect to the special demands of X-ray fluorescence analysis (XRF) and inductively coupled plasma mass spectrometry in combination with laser ablation (LA-ICP-MS).
The mass fractions of all elements were 0-1500 mg/kg and the materials were produced as granulates and solid discs with a diameter of 40 mm and thicknesses of 1, 2, and 6 mm. It could be shown that the signals measured by XRF strongly depend on the thickness of polymeric samples.
Macroscopic homogeneity was assessed with XRF measuring a total of 180 samples. The microscopic homogeneities were determined for a material with average elemental mass fractions with the aid of synchrotron radiation (SR) µ-XRF and LA-ICP-MS. Sufficient macroscopic and microscopic homogeneities for all elements could be achieved. It was observed that organic additives show a better homogeneity than oxides.
XRF and LA-ICP-MS were successfully calibrated with the new materials. Limits of detection were in the range of 0.4-22 mg/kg for XRF and 2.3-26.8 mg/kg for LA-ICP-MS. The materials are considered as candidate reference materials (RM) by the Federal Institute of Materials Research and Testing (BAM, Germany).
Within an interdisciplinary project, preliminary results of which were published in 2007, a group of 65 silver coins (denarii) of Trajan, evenly distributed over the entire span of his reign (2nd to 6th consulate), as well as 3 coins from the reign of his predecessor, the emperor Nerva (AD 9698), had been acquired on the coin market. These pieces could be cross-sectioned in order to carry out analyses. Measurements were performed with µ-XRF and µ-SRXRF to check the fineness of the denarius alloy as well as to investigate if the coins of the different consulates showed distinct traits concerning the main impurities which could suggest a change of ore sources. Furthermore, it was examined whether the influx of precious metals into the Roman treasury after Trajan's Dacian campaigns (AD 101/102 and 105/106) could have had any repercussions on the composition of the denarius alloy; comparative data was provided by the analysis of nine imitations of Roman Republican denarii presumably struck in Dacia. Documentation of the cross-sections was performed with SEM/EDX in order to clarify details concerning the specific microstructure of the coins. An enrichment of Ag of approx. 100 to 200 µm in the near surface regions of most of the coins could be observed, which is due to corrosion effects. Previous metallographic analyses done by several scholars had been inadequate to clarify the central numismatic and economic questions. With the presented analyses, it was possible to correct the results of the earlier research and to provide, for the first time, a secure basis of data for the investigation of the development of the silver alloy used for denarii in Trajan's reign.
In the determination of the provenance of gold in archaeological artifacts, trace elements are more significant than the main components. Several minute fragments of natural Carpathian gold-placer and primary-and some very small (a few milligrams) fragments of archaeological items were studied using micro Synchrotron Radiation X-Ray Fluorescence (micro SR-XRF) at the BESSY Synchrotron Facility in Berlin, Germany. The goal of the study was to identify the trace elements characterizing Carpathian gold, looking especially at Sn, Sb, Pb and Te, and to determine if the gold in the archaeological items is native or refined. Applications to the authentication and provenance of nine Dacian gold bracelets, koson coins and two Bronze Age items are presented.
Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission-electron probe microanalysis (FE-EPMA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and synchrotron micro X-ray fluorescence spectroscopy (SR-µ-XRF). This study assesses the accuracy, precision and detection limits of these mostly non-destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE-EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA-ICP-MS analyses required larger gold particles (> 60 µm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA-ICP-MS measurements had lower detection limits, precision was lower than FE-EPMA and SR-µ-XRF. The higher variability in absolute values measured by LA-ICP-MS, possibly due to micro-inclusions, had to be critically assessed. Non-destructive point analyses of gold alloys by SR-µ-XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE-EPMA, but higher than those for elements measured by LA-ICP-MS.
Shading Effects in SR-TXRF: Calcullations and Experimental Visualization using a Color X-ray Camera
(2014)
Shading Effects in SR-TXRF: Calculations and Experimental Visualization using a Color X-ray Camera
(2014)
Recent results from a three-year multi-disciplinary project on Ancient Egyptian gold jewellery revealed that items of jewellery from the Middle Kingdom to the New Kingdom were manufactured using a variety of alluvial gold alloys. These alloys cover a wide range of colours and the majority contain Platinum Group Elements inclusions. However, in all the gold foils analysed, these inclusions were found to be absent. In this work a selection of gilded wood and leather items and gold foil fragments, all from the excavations by John Garstang at Abydos (primarily from Middle Kingdom graves), were examined using Scanning Electron Microscopy-Energy Disperse Spectroscopy (SEM-EDS), X-Ray Fluorescence (µXRF), Particle Induced X-Ray Emission (µPIXE) and Double Dispersive X-Ray Fluorescence (D²XRF). The work allowed us to characterise the composition of the base-alloys and also to reveal the presence of Pt at trace levels, confirming the use of alluvial gold deposits. Corrosion products were also investigated in the foils where surface tarnish was visually observed. Results showed that the differences in the colour of corrosion observed for the foils are related not only to the thickness of the corrosion layer but also to a multi-layer structure containing the various corrosion products.
To better study the impact of nanoparticles on both in vitro and in vivo models, tissue distribution and cellular doses need to be described more closely. Here silver nanoparticles were visualized in alveolar macrophages by means of synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μXRF) with high spatial resolution of 3 × 3 μm2. For the spatial allocation of silver signals to cells and tissue structures, additional elemental labeling was carried out by staining with eosin, which binds to protein and can be detected as bromine signal with SR-μXRF. The method was compatible with immunostaining of macrophage antigens. We found that the silver distribution obtained with SR-μXRF was largely congruent with distribution maps from a subsequent laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) of the same tissue sites. The study shows a predominant, though not exclusive uptake of silver into alveolar macrophages in the rat lung, which can be modeled by a similar uptake in cultured alveolar macrophages. Advantages and limitations of the different strategies for measuring nanoparticle uptake at the single cell level are discussed.
Synchrotron radiation sources with their unique properties in terms of intensity, polarization and adjustability offer a wide range of possibilities in materials research. A basic introduction about the creation and special properties of synchrotron radiation will be given. Examples of current work at BAMline, the high-energy measuring facility of the Federal Institute for Materials Research and Testing at the synchrotron BESSY, are used to illustrate the possibilities and limitations of existing measuring methods. It will be shown how the formation of corrosion layers can be tracked, how the abrasion of implants leads to the introduction of heavy metals into the surrounding bone matrix and how the detection of smallest impurities in gold is possible by optimizing the measuring conditions. Finally, an outlook at the hardware and software developments to be expected in the coming years is given.
The present study investigates early stages of ZIF-8 crystallization up to 5 minutes post mixing of precursor solutions. Dispersive X-ray Absorption Spectroscopy (DXAS) provides a refined understanding of the evolution of the coordination environment during ZIF-8 crystallization. Linear Combination Fiting (LCF) suggests tetrakis(1-methylimidazole)zinc2+ to be a suitable and stable mononuclear structure analogue for some early stage ZIF-8 intermediates. Our results pave the way for more detailed studies on physico-chemical aspects of ZIF-8 crystallization to better control tailoring ZIF-8 materials for specific applications.
The Color X-ray Camera CXC or SLcam® is an energy-resolving X-ray camera capable of energy- and space-resolved measurements. It consists of a high-speed CCD detector coupled to a polycapil-lary optic that conducts the X-ray photons from the probe to distinct pixels onto the detector. The camera is capable of fast acquisition of spatially and energy resolved fluorescence images. A dedicated software enables the acquisition and the online processing of the spectral data for all 69696 pixels, leading to a real-time visualization of the elements distribution in a sample. It was developed in a joint project with BAM, IFG Berlin and PN Sensors. In this contribution we will mainly discuss the use of the CXC at our beamline, the BAMline at BESSY II and imaging applications of the CXC from different areas, like biology and archaeometry. Additionally new developments for the use of the detector without optics, like wavelength dispersive detection or 1shot-XANES, will be presented.
In materials science, traditional techniques for analyzing layered structures are essential for obtaining information about local structure, electronic properties and chemical states. While valuable, these methods often require high vacuum environments and have limited depth profiling capabilities. The grazing exit x-ray absorption near-edge structure (GE-XANES) technique addresses these limitations by providing depth-resolved insight at ambient conditions, facilitating in situ material analysis without special sample preparation. However, GE-XANES is limited by long data acquisition times, which hinders its practicality for various applications. To overcome this, we have incorporated Bayesian optimization (BO) into the GE-XANES data acquisition process. This innovative approach potentially reduces measurement time by a factor of 50. We have used a standard GE-XANES experiment, which serve as reference, to validate the effectiveness and accuracy of the BO-informed experimental setup. Our results show that this optimized approach maintains data quality while significantly improving efficiency, making GE-XANES more accessible to a wider range of materials science applications.
With increasing demand and environmental concerns, researchers are exploring new materials that can perform as well or better than traditional materials while reducing environmental impact. The BAMline, a real-life sample materials research beamline, provides unique insights into materials’ electronic and chemical structure at different time and length scales. The beamline specializes in x-ray absorption spectroscopy, x-ray fluorescence spectroscopy, and tomography experiments. This enables real-time optimization of material properties and performance for various applications, such as energy transfer, energy storage, catalysis, and corrosion resistance. This paper gives an overview of the analytical methods and sample environments of the BAMline, which cover non-destructive testing experiments in materials science, chemistry, biology, medicine, and cultural heritage. We also present our own synthesis methods, processes, and equipment developed specifically for the BAMline, and we give examples of synthesized materials and their potential applications. Finally, this article discusses the future perspectives of the BAMline and its potential for further advances in sustainable materials research.
Absorption effects in total reflection X-ray fluorescence (TXRF) analysis are important to consider, especially if external calibration is to be applied. With a color X-ray camera (CXC), that enables spatially and energy resolved XRF analysis, the absorption of the primary beam was directly visualized for mL-droplets and an array of pL-droplets printed on a Si-wafer with drop-on-demand technology. As expected, deposits that are hit by the primary beam first shade subsequent droplets, leading to a diminished XRF signal. This shading effect was quantified with enhanced precision making use of sub-pixel analysis that improves the spatial resolution of the camera. The measured absorption was compared to simulated results using three different model calculations. It was found they match very well (average deviation < 10%). Thus errors in quantification due to absorption effects can be accounted for in a more accurate manner.
The reaction of iron chlorides with an alkaline reagent is one of the most prominent methods for the synthesis of iron oxide nanoparticles. We studied the particle formation mechanism using triethanolamine as reactant and stabilizing agent. In situ fast-X-ray absorption near edge spectroscopy and small-angle X-ray scattering provide information on the oxidation state and the structural information at the same time. In situ data were complemented by ex situ transmission electron microscopy, wide-angle X-ray scattering and Raman analysis of the formed nanoparticles. The formation of maghemite nanoparticles (γ-Fe2O3) from ferric and ferrous chloride was investigated. Prior to the formation of these nanoparticles, the formation and conversion of intermediate phases (akaganeite, iron(II, III) hydroxides) was observed which undergoes a morphological and structural collapse. The thus formed small magnetite nanoparticles (Fe3O4) grow further and convert to maghemite with increasing reaction time.
A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ-2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 µm is achieved.
Slicing - a new method for non destructive 3D elemental sensitive characterization of materials
(2014)
Recent advances in synchrotron sources and detector technology have led to substantial improvements in spatial resolution and detection limits for X-ray fluorescence analysis (XRF). However, the non-destructive three-dimensional elemental sensitive characterization of samples remains a challenge. We demonstrate the use of the so-called 'Color X-ray Camera' (CXC) for 3D measurements for the first time. The excitation of the sample is realized with a thin sheet-beam. The stepwise movement of the sample allows getting the elemental distribution for each layer with one measurement. These layers can be combined to a full 3D dataset for each element afterwards. Since the information is collected layer by layer, there is no need to apply reconstruction techniques, which quite often are the reason for artifacts in the results achieved by computed tomography (CT). The field of applications is wide, as the 3D elemental distribution of a material contains clues to processes inside the samples from a variety of origins. The technique is of special interest and well suited for biological specimens, because their light matrix minimizes restricting absorption effects. Measurement examples of a hornet and the teeth of a Sorex araneus are shown.
A liver biopsy specimen from a Wilson’s disease (WD) patient was analyzed by means of micro-X-ray fluorescence (mXRF) spectroscopy to determine the elemental distribution. First, bench-top mXRF was utilized for a coarse scan of the sample under laboratory conditions. The resulting distribution maps of copper and iron enabled the determination of a region of interest (ROI) for further analysis. In order to obtain more detailed elemental information, this ROI was analyzed by synchrotron radiation (SR)-based mXRF with a beam size of 4 mm offering a resolution at the cellular level. Distribution maps of additional elements to copper and iron like zinc and manganese were obtained due to a higher sensitivity of SR-mXRF. In addition to this, X-ray absorption near edge structure spectroscopy (XANES) was performed to identify the oxidation states of copper in WD. This speciation analysis indicated a mixture of copper(I) and copper(II) within the WD liver tissue.
This Report describes the certification of the reference material antimony implanted in Si/SiO2 intended to be used for calibration of surface and near surface analytical methods. It describes the preparation, homogeneity measurements and the analytical work performed for the certification of both Areal density of antimony Atoms (retained dose) and the isotope amount Ratio as well as giving considerations on the stability of the material.
n this study, two green synthesis routes were used for the synthesis of Ag/ZnO nanoparticles, using cassava starch as a simple and low-cost effective fuel and Aloe vera as a reducing and stabilizing agent. The Ag/ZnO nanoparticles were characterized and used for bacterial dis-
infection of lake water contaminated with Escherichia coli (E. coli). Characterization indicated the formation of a face-centered cubic structure of metallic silver nanoparticles with no insertion of Ag into the ZnO hexagonal wurtzite structure. Physicochemical and bacteriological analyses described in “Standard Methods for the Examination of Water and Wastewater” were used to evaluate the efficiency of the treatment. In comparison to pure ZnO, the synthesized Ag/ZnO nanoparticles showed high efficiencies against Escherichia coli (E. coli) and general coliforms present in the lake
water. These pathogens were absent after treatment using Ag/ZnO nanoparticles. The results indicate that Ag/ZnO nanoparticles synthesized via green chemistry are a promising candidate for the treatment of wastewaters contaminated by bacteria, due to their facile preparation, low-cost synthesis,and disinfection efficiency.
Fire-gilding is a historic technique for the application of golden layers on a number of different base materials utilizing a gold amalgam. This technique leaves a significant amount of Hg in the golden layer, giving archeometrists a reliable indicator to identify firegildings.
Recent findings on presumably fire-gilded objects have shown in several cases significantly lower Hg content than previously studied objects. This prompted a synchrotron-based X-ray fluorescence investigation into the Hg distribution along the material–gilding interface, as well as a series of measurements regarding the Hg content development in fire-gilded samples during artificial aging. This work presents findings on laboratory-prepared fire-gildings, indicating an Hg enrichment at the interface of firegilded silver samples. Notably, such an enrichment is missing in fire-gilded copper samples. Further, it is confirmed that fire-gilded layers typically do not undercut an Hg bulk content of 5%. In this light, it seems improbable that ancient samples that contain <5% Hg are fire-gilded. The results presented in this study might lead to a non-destructive method to identify the Hg enrichment at the interface. This might be obtained by a combination of different non-destructive measurements and might also work unambiguously in samples in which the gold top layer is altered.
X-ray absorption spectroscopy (XAS) provides a unique, atom-specific tool to probe the electronic structure of solids. By surmounting long-held limitations of powder-based XAS using a dynamically averaged powder in a Resonant Acoustic Mixer (RAM), we demonstrate how time-resolved in situ (TRIS) XAS provides unprecedented detail of mechanochemical synthesis. The use of a custom-designed dispersive XAS (DXAS) setup allows us to increase the time resolution over existing fluorescence measurements from ∼15 min to 2 s for a complete absorption spectrum. Hence, we here establish TRIS-XAS as a viable method for studying mechanochemical reactions and sampling reaction kinetics. The generality of our approach is demonstrated through RAM-induced (i) bottom-up Au nanoparticle mechanosynthesis and (ii) the synthesis of a prototypical metal organic framework, ZIF-8. Moreover, we demonstrate that our approach also works with the addition of a stainless steel milling ball, opening the door to using TRIS-DXAS for following conventional ball milling reactions. We expect that our TRIS-DXAS approach will become an essential part of the mechanochemical tool box.
The use of polycapillary optics in confocal micro-X-ray fluorescence analysis (CMXRF) enables the destruction-free 3D investigation of the elemental composition of samples. The energy-dependent transmission properties, concerning intensity and spatial beam propagation of three polycapillary half lenses, which are vital for the quantitative interpretation of such CMXRF measurements, are investigated in a monochromatic confocal laboratory setup at the Atominstitut of TU Wien, and a synchrotron setup on the BAMline beamline at the BESSY II Synchrotron, Helmholtz-Zentrum-Berlin. The empirically established results, concerning the intensity of the transmitted beam, are compared with theoretical values calculated with the polycap software package and a newly presented analytical model for the transmission function.
The resulting form of the newly modelled energy-dependent transmission function is shown to be in good agreement with Monte Carlo simulated results for the complete energy regime, as well as the empirically established results for the energy regime between 6 keV and 20 keV. An analysis of possible fabrication errors was conducted via pinhole scans showing only minor fabrication errors in two of the investigated polycapillary optics. The energy-dependent focal spot size of the primary polycapillary was investigated in the laboratory via the channel-wise evaluation of knife-edge scans. Experimental results are compared with data given by the manufacturer as well as geometric estimations for the minimal focal spot size. Again, the resulting measurement points show a trend in agreement with geometrically estimated results and manufacturer data.
In a color X-ray camera spatial resolution is achieved by means of a polycapillary optic conducting X-ray photons from small regions on a sample to distinct energy dispersive pixels on a CCD matrix. At present, the resolution limit of color X-ray camera systems can go down to several microns and is mainly restricted by Pixel dimensions. The recent development of an efficient subpixel resolution algorithm allows a release from pixel size, limiting the resolution only to the quality of theoptics. In this work polycapillary properties that influence the spatial resolution are systematized and assessed both theoretically and experimentally. It is demonstrated that with the current technological Level reaching one micron resolution is challenging, but possible.
Quantitative Analysis and 2D/3D Elemental Imaging of Cocoa Beans Using X‑ray Fluorescence Techniques
(2023)
As an important raw material for the confectionery industry, the cocoa bean (Theobroma cacao L.) has to meet certain legal requirements in terms of food safety and maximum contaminant levels in order to enter the cocoa market. Understanding the enrichment and distribution of essential minerals but also toxic metals is of utmost importance for improving the nutritional quality of this economically important raw food material. We present three X-ray fluorescence (XRF) techniques for elemental bio-imaging of intact cocoa beans and one additional XRF technique for quantitative analysis of cocoa pellets. The interrelation of all the methods presented gives a detailed picture of the content and 3D-resolved distribution of elements in complete cocoa beans for the first time.
The structure and composition of ancient gold objects retain information about their long history of manufacture, from the exploitation of the ore to the finishing touches, as well as evidence of their use, deposition, and degradation. By developing an efficient analytical strategy, it is possible to retrieve that information. This chapter sets the necessary foundation 131to explore fully the analytical results presented in the following chapters of this volume. The techniques employed in the analyses of the Egyptian jewellery are described and the analytical parameters provided. For more established techniques, only brief introductions are presented, while more recent developments are presented in greater detail.
Gold ist eines der sieben bereits in der Antike bekannten Metalle und wurde wegen seines Glanzes und seiner Seltenheit seit jeher als Tauschmittel und zur Herstellung von Schmuck verwendet. Außerdem ist es leicht zu bearbeiten und weitgehend resistent gegen chemische Einflüsse.
Die Analyse von Gold mit der durch Synchrotronstrahlung angeregten Röntgenfluoreszenzanalyse ist zerstörungsfrei und liefert Informationen über die in der untersuchten Probe vorhandenen chemischen Elemente.
Im Mittelpunkt der hier vorgestellten Untersuchungen an der BAMline stehen Fragen nach der Herkunft, dem Herstellungsprozess und der Zugehörigkeit von Goldfunden. Die verschiedenen Fragestellungen werden anhand einer Reihe von Beispielen erläutert, die vom Wikingerschatz von Hiddensee über die Himmelsscheibe von Nebra bis hin zu Funden aus Ägypten reichen. Darüber hinaus werden die heute am Synchrotron verfügbaren modernen Messmethoden vorgestellt.
Trace elements are chemical elements whose concentration in a material is very low. The exact definition depends on the application and varies for example between 100 micrograms per gram in analytical chemistry and 1000 micrograms per gram in geology. The ability to detect trace elements fast and quantitatively is of great importance in many areas of science and technology. With its high brilliance and flexibility in the excitation conditions, synchrotron radiation is an ideal tool for detecting traces even in small sample quantities. In this contribution I will report about the use of X-ray fluorescence(XRF)for qualitative and quantitative element sensitiveanalysis. In addition to the fundamentals of XRF and its quantification methods, the advantages and problems of different geometries like e.g. microXRF, Total Reflection X-ray Fluorescence (TXRF)or Double Dispersive XRF (D²XRF) will be discussed. Practical examples from BAMline from the research fields of medicine, geology and archaeometry will complete the lecture.
A study regarding the possibility to use compound refractive lenses (CRLs) for X-ray absorption spectroscopy (XAS) was conducted. For XAS measurements the energy of the monochromatic incident beam has to be tuned over an energy range which is broader than the energy bandwidth of a CRL. To prove that µ-XAS with compound refractive lenses is possible, it had to be investigated how changes in the energy influence the beam parameters. This was done by tuning the energy around the nominal energy of the lens and recording images with a high resolution X-ray imaging setup. To investigate the changes in the spot size the scintillator was placed at the nominal focal distance and scans along the beam axis were performed. The effect on the photon flux of the incident beam due to absorption in the lens was investigated by performing XANES measurement on different reference materials with and without CRL. The results of these measurements using a CRL designed for 9 keV are shown and discussed.
In this work, a new setup for dispersive XAFS measurements is presented. This reproducible and scanningfree setup yields both time- and laterally-resolved XAFS experiments in a ‘single-shot’. It allows a straightforward adjustment for probing different elements covering many relevant applications in materials science. An incoming energetic broadband beam is diffracted by a Si (111) crystal after passing through the sample and collected by an area sensitive detector. Depending on the energy range of the incoming beam, XANES and/or EXAFS spectra can be recorded with a time resolution down to 1 s. The feasibility of this setup was demonstrated at the BAMline at BESSY II (Berlin, Germany) with reference Fe and Cu foils and the results are hereby presented and discussed. Additionally, an application where time resolution on the second scale is required is briefly evaluated. The presented example concerns studying early stages of zinc(II)2-methylimidazolate (ZIF-8) crystallization. This is particularly important for biomedical applications.
Various applications for artificial intelligence in the context of spectroscopy will be presented. in particular, examples from BAMline will be presented. After a short introduction to synchrotron radiation, artificial intelligence algorithms for the quantification of X-ray fluorescence measurement are discussed. In the second example, information retrieval by natural language processing is discussed.
We report on the trace analysis of copper and iron impurities in multicrystalline silicon wafers with the microbeam X-ray fluorescence (µ-XRF) technique. The efficiency of solar cells, which are based on multicrystalline silicon wafers, is strongly influenced by minor contamination with metals such as copper and iron. Application of compound refractive lenses (CRLs) in µ-XRF allows versatile two-dimensional mapping of relevant contaminations and localization of their sites of deposition. In this context, the measured bulk average limit of detection (LOD) was one picogram of iron and copper per gram of silicon. We suggest that µ-XRF is a valuable tool for non-destructive spatial (3D) quantification of metal impurities in a wide range of materials and devices whose functioning could be critically affected by impurities.
Metakaolin-based alkali activated mortars (AAM) - with and without CuSO4·5H2O and ZnO addition (mass ratio Mn+/solid binder 0.08% to 1.7%) - were casted and exposed within an extensive long-term field campaign over the period of 20 months to a sewer basin, strongly affected by biogenic acid corrosion. (Un-)exposed AAM were tested regarding their physicochemical and microstructural properties, bioreceptivity and overall durability. Metal addition led to a retarding effect during alkali-activation reaction, as well as to an increase in open porosity of up to 3.0% and corresponding lower compressive strength of up to 10.9%. Reduced microbial colonization and diversity were observed on AAM with Cu, while Zn addition led to increased biodiversity. We propose that the observed higher durability of Cu-doped AAM is due to antibacterial effects and associated reduction of biogenic acid production, superseding overall negative effects of metal-dosage on physical material properties. Observed lower durability of Zn-doped AAM was related to combined negative physicochemical and microbial effects.
The mechanism of action of zirconium permanent modifiers on graphite surfaces was investigated in order to understand its influence on the analytical signal in atomic and molecular absorption spectrometry (AAS/MAS). For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. We propose here a mechanism, where ZrO2 acts as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface. No evidence of the formation of zirconium carbide was found. Consequently, as the CaF formation is catalysed by a heterogeneous catalyst, surface modifications with ZrO2 nanoparticles and ZrO xerogels were investigated in order to increase the surface area. Their influence was evaluated in the molecule formation of CaF, CaCl, CaBr, and CaI. Graphite furnace modification with zirconium oxide nanoparticles proves to be the best choice for fluorine analysis with a signal enhancement of more than eleven times with respect a non-coated graphite furnace. However, the influence of zirconium modifications in the analytical signals of Cl, and I is lower than the F signals or even negative in case of the Br. Understanding zirconium modifiers as heterogeneous catalysts offers a new perspective to AAS and MAS, and reveals the potential of surface analytical methods for development of improved permanent modifiers and graphite furnace coatings.
The precise analysis of cation diffusion profiles through corrosion scales is an important aspect to evaluate corrosion phenomena under multicomponent chemical load, as during high‐temperature corrosion under deposits and salts. The present study shows a comprehensive analysis of cation diffusion profiles by electron microprobe analysis and microbeam X‐ray absorption near edge structure (µ‐XANES) spectroscopy in mixed oxide/sulfide scales grown on Fe–Cr model alloys after exposing them to 0.5% SO2. The results presented here correspond to depth‐dependent phase identification of oxides and sulfides in the corrosion scales by µ‐XANES and the description of oxidation‐state‐dependent diffusion profiles. Scales grown on low‐ and high‐alloyed materials show both a well‐pronounced diffusion profile with a high concentration of Fe3+ at the gas and a high concentration of Fe2+ at the alloy interface. The distribution of the cations within a close‐packed oxide lattice is strongly influencing the lattice diffusion phenomena due to their different oxidation states and therefore different crystal‐field preference energies. This issue is discussed based on the results obtained by µ‐XANES analysis.
In this talk, the features of X-ray fluorescence analysis with synchrotron radiation will be presented. First, the basics of the origin of synchrotron radiation and X-ray fluorescence analysis and the experimental setup will be discussed. Then, examples of trace element detection, micrometer resolution, and application of the X-ray color camera will be shown.
In X-ray fluorescence (XRF), a sample is excited with X-rays, and the resulting characteristic radiation is detected to detect elements quantitatively and qualitatively. Quantification is traditionally done in several steps:
1. Normalization of the data
2. Determination of the existing elements
3. Fit of the measured spectrum
4. Calculation of concentrations with fundamental parameters / MC simulations / standard based
The problem with standard based procedures is the availability of corresponding standards. The problem with the calculations is that the measured intensities for XRF measurements are matrix-dependent. Calculations must, therefore, be performed iteratively (= time consuming) in order to determine the chemical composition.
First experiments with gold samples have shown the feasibility of machine learning based quantification in principle. A large number of compositions were simulated (> 10000) and analyzed with a deep learning network. For first experiments, an ANN (Artificial Neural Network) with 3 hidden layers and 33x33x33 neurons was used. This network learned the mapping of spectra to concentrations using supervised learning by multidimensional regression. The input layer was formed by the normalized spectrum, and the output layer directly yielded the searched values. The applicability for real samples was shown by measurements on certified reference materials.
An automatic sample changer chamber for total reflection X-ray fluorescence (TXRF) and X-ray absorption near-edge structure (XANES) analysis in TXRF geometry was successfully set up at the BAMline at BESSY II. TXRF and TXRF-XANES are valuable tools for elemental determination and speciation, especially where sample amounts are limited (<1 mg) and concentrations are low (ng ml⁻¹ to μg ml⁻¹). TXRF requires a well defined geometry regarding the reflecting surface of a sample carrier and the synchrotron beam. The newly installed chamber allows for reliable sample positioning, remote sample changing and evacuation of the fluorescence beam path. The chamber was successfully used showing accurate determination of elemental amounts in the certified reference material NISTwater 1640. Low limits of detection of less than 100 fg absolute (10 pg ml⁻¹) for Ni were found. TXRF-XANES on different Re species was applied. An unknown species of Re was found to be Re in the +7 oxidation state.
The aim of the present study is to characterize emeralds from different mines of Brazil by using Synchrotron Radiation X-ray Fluorescence Microanalysis (µ-SRXRF). The advantage of this technique is that we can analyze a homogeneous, inclusion free area of the stone with the microbeam to distinguish the elemental fingerprint according to the provenance of the emerald. A total of 47 samples belonging to 5 different Brazilian mines were studied in this work and 28 elements were identified. By means of Principal Component Analysis (PCA) it is possible to build different groups according to the provenance of the stones, which allows to assign samples of unknown origin to the according mine.
The content of chromium in different oxidation states in chromium-treated wood was studied with XANES (X-ray absorption near-edge structure) measurements at the Cr K absorption edge. It could be shown that wood samples treated with Cr(VI) (pine and beech) did still contain a measurable content of Cr(VI) after four weeks conditioning. If such wood samples were heat exposed for 2 h with 135 °C prior conditioning, Cr(VI) was no longer detected by XANES, indicating a complete reduction to chromium (III).
Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens.
In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by 'drop on demand' technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation.
A set of compound refractive lenses (CRLs), mounted on a silicon wafer, was obtained from the Institut für Mikrostrukturtechnik Karlsruhe. The CRLs were characterized at the BAMline at the synchrotron BESSYII in Berlin. It could be demonstrated that beam diameters below 1 µm can be obtained. The beam size accepted by the lenses is (140 × 140) µm2, thus the intensity gain in the micrometer spot, including absorption, is about 15,000. It is possible to switch between different beam energies within a few minutes. First results of scans and the application of the lenses for MicroXANES (X-ray absorption near-edge structure) measurements are presented in this paper. Also, the possibility of MicroEXAFS (extended X-ray absorption fine structure) measurements is discussed.
The Sarmizegetusa bracelets
(2010)
We present the authentication and analysis of these beautiful Dacian bracelets of the first century BC, originally pillaged by treasure hunters and recovered thanks to an international crime chase. They were originally fashioned from gold panned from the rivers or dug from the mines of Transylvania and hammered into the form of coiled snakes. The lack of context is the greatest loss, but a votive purpose is likely given their proximity to the great sacred centre at Sarmizegetusa Regia.
Rund ein Jahr haben DIN und DKE in einem gemeinsamen Projekt mit dem Bundesministerium für Wirtschaft und Energie und zusammen mit ca. 300 Fachleuten aus Wirtschaft, Wissenschaft, öffentlicher Hand und Zivilgesellschaft an der Normungsroadmap Künstliche Intelligenz gearbeitet. Eine hochrangige Steuerungsgruppe unter dem Vorsitz von Prof. Wolfgang Wahlster hat die Erarbeitung koordiniert und begleitet.
Ziel der Roadmap ist die frühzeitige Entwicklung eines Handlungsrahmens für die Normung und Standardisierung, der die internationale Wettbewerbsfähigkeit der deutschen Wirtschaft unterstützt und europäische Wertmaßstäbe auf die internationale Ebene hebt.
The development of earth-abundant catalysts for selective electrochemical CO2 conversion is a central challenge. Cu-Sn bimetallic catalysts can yield selective CO2 reduction toward either CO or formate. This study presents oxide-derived Cu-Sn catalysts tunable for either product and seeks to understand the synergetic effects between Cu and Sn causing these selectivity trends. The materials undergo significant transformations under CO2 reduction conditions, and their dynamic bulk and surface structures are revealed by correlating observations from multiple methods—X-ray absorption spectroscopy for in situ study, and quasi in situ X-ray photoelectron spectroscopy for surface sensitivity. For both types of catalysts, Cu transforms to metallic Cu0 under reaction conditions. However, the Sn speciation and content differ significantly between the catalyst types: the CO-selective catalysts exhibit a surface Sn content of 13 at. % predominantly present as oxidized Sn, while the formate-selective catalysts display an Sn content of ≈70 at. % consisting of both metallic Sn0 and Sn oxide species. Density functional theory simulations suggest that Snδ+ sites weaken CO adsorption, thereby enhancing CO selectivity, while Sn0 sites hinder H adsorption and promote formate production. This study reveals the complex dependence of catalyst structure, composition, and speciation with electrochemical bias in bimetallic Cu catalysts.
Phoenician ivory objects (8th century B.C., Syria) from the collections of the Badisches Landesmuseum, Karlsruhe, Germany, have been studied with full field X-ray fluorescence microimaging, using synchrotron radiation (SR-FF-microXRF). The innovative Color X-ray Camera (CXC), a full-field detection device (SLcam), was used at the X-ray fluorescence beamline of the ANKA synchrotron facility (ANKA-FLUO, KIT, Karlsruhe, Germany) to noninvasively study trace metal distributions at the surface of the archeological ivory objects. The outstanding strength of the imaging technique with the CXC is the capability to record the full XRF spectrum with a spatial resolution of 48 µm on a zone of a size of 11.9 × 12.3 mm² (264 × 264 pixels). For each analyzed region, 69696 spectra were simultaneously recorded. The principal elements detected are P, Ca, and Sr, coming from the ivory material itself; Cu, characteristic of pigments; Fe and Pb, representing sediments or pigments; Mn, revealing deposited soil minerals; Ti, indicating restoration processes or correlated with Fe sediment traces; and Au, linked to a former gilding. This provides essential information for the assessment of the original appearance of the ivory carvings. The determined elemental maps specific of possible pigments are superimposed on one another to visualize their respective distributions and reconstruct the original polychromy and gilding. Reliable hypotheses for the reconstruction of the original polychromy of the carved ivories are postulated on this basis.
In the quest for finding the ideal synchrotron-radiation-induced imaging method for the investigation of trace element distributions in human bone samples, experiments were performed using both a scanning confocal synchrotron radiation micro X-ray fluorescence (SR-mXRF) (FLUO beamline at ANKA) setup and a full-field color X-ray camera (BAMline at BESSY-II) setup. As zinc is a trace element of special interest in bone, the setups were optimized for its detection. The setups were compared with respect to count rate, required measurement time and spatial resolution. It was demonstrated that the ideal method depends on the element of interest. Although for Ca (a major constituent of the bone with a low energy of 3.69 keV for its K alpha XRF line) the color X-ray camera provided a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-µXRF setup was able to sufficiently image the distribution.
In this talk I’ll describe the use of artificial neural networks (ANN) for quantifying X-ray fluorescence (XRF) measurements. The main idea of this talk is to give an overview of the process needed to generate a model that can then be applied to a specific problem.
In XRF, a sample is excited with X-rays and the resulting characteristic radiation is detected to determine elements quantitatively and qualitatively. This is traditionally done in several time-consuming steps. I’ll show the possibilities and problems of using a neural network to realise a "one-click" quantification. This includes generating training data using Monte Carlo simulation and augmenting the existing data set with an ANN to generate more data. The search for the optimal hyperparameters, manually and automatically, is also described. For the case presented, we were able to train a network with a mean absolute error of 0.1% by weight for the synthetic data and 0.7% by weight for a set of experimental data obtained with certified reference materials.
The vanadium redox flow battery (VRFB) is currently a potential candidate for stationary energy storage. A major challenge is the unintended vanadium transport through the separator, which results in a fade of capacity. To overcome this issue, it is necessary to understand the transport processes in the membrane on a more fundamental level. In this work, the vanadium species distribution in Nafion™ 117 after cyclization was investigated. Two membranes, one from a charged VRFB and another from a discharged VRFB, were analyzed using ultraviolet–visible spectroscopy (UV/VIS) and X-ray absorption near edge structure spectroscopy (XANES). Little difference between the two membranes was recognizable according to the UV/VIS results. In comparison, the XANES results showed that the membrane from the charged VRFB contains more V3+ than VO2+, whereas for the discharged case, more VO2+ is present in the membrane.
We performed spatially resolved synchrotron-induced x-ray fluorescence analyses (SY-XRF) of five silverpoint drawings from the famous `Karlsruhe sketchbook´ and a silverpoint, which is assumed to be an original one used by the Renaissance artist Hans Baldung Grien (1484-1545) himself. The silverpoint, one out of a very small number of ancient styli conserved nowadays, is fixed on the so-called `Karlsruhe sketchbook´. Measurements were executed at the FLUO-TOPO beamline at the electron storage ring ANKA. It has been shown, that SY-XRF at this beamline is nondestructive and sensitive enough for the analysis of minor and major elements in the silver strokes. This study provides new insights into this graphical technique and ancient drawing instruments: results are that three drawings have been created with a common type of silverpoint containing about (10.4 ± 0.7) wt% of Cu. In all the cases, Hg at a 10% level by weight was identified in the strokes. Presence of Hg is not due to the original silver alloy, but is a result of a general alteration phenomenon of silverpoint drawings. This fact is confirmed by the analysis of the original silverpoint, which contains only small traces of Hg. The result for the copper content of the silverpoint (10.4 ± 1.7) wt% is in good agreement with that of these three drawings. It is supposable that the silverpoint found attached today served for the creation of the corresponding drawings. Moreover, the graphical technique of Baldung is found to be continual over three decades. Only one very late drawing dated to 1543 was probably realized with another silverpoint, containing about 3 wt% of Cu. This difference in the chemical composition of drawings from the late period might be used as a more precise dating indicator of Baldung drawings that are not clearly attributed to a certain period.
Studies by Synchrotron Radiation-X-Ray Fluorescence (SR-XRF) for the search of the presence of trace elements like Sb, Sn, Te and Pb in archaeological metallic objects found on the territory of Romania-old coins and Bronze Age jewelry, aimed to determine the provenance of the gold used in their manufacture. The results are compared with the detailed elemental composition of alluvial or primary gold samples, obtained by the same technique. This work attempted to establish the origin of the gold used for the mint of two different types of koson coins. We found that the kosons with monogram are made of refined gold, while the one used for the kosons without monogram is mainly alluvial. The gold used in the manufacture of the Calarasi Vulchitrun-type disk and the Tauteu hair ring is also of alluvial origin.
The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed.
Besides conventional scanning X-ray fluorescence imaging at synchrotron sources, full-field X-ray fluorescence (FF-XRF) imaging techniques that do not implicitly require spatial scanning of the sample have become available. FF-XRF has become achievable thanks to the development of a new type of energy dispersive CCD-based 2D detector, also referred to as a 'color X-ray camera (CXC)' or 'SLcam'. We report on different imaging schemes for biological samples using FF-XRF imaging: (a) 2D 'zoom' imaging with pinhole optics using the 'camera obscura' principle; (b) 2D 'fixed magnification' imaging using magnifying polycapillary optics; and (c) 3D-FF-XRF imaging using an X-ray sheet beam or computed tomography (CT). The different FF-XRF imaging modes are illustrated using the crustacean Daphnia magna, a model organism for investigating the effects of metals on organism/ecosystem health, and foraminifera, a class of amoeboid protist. Detailed analytical characterization of the set-up is performed through analyzing various reference materials in order to determine limits of detection (LODs) and sensitivities. Experiments were performed using the BAMline at the BESSY synchrotron (Berlin, Germany) and using the P06 Hard X-ray Microprobe at the PETRAIII synchrotron (Hamburg, Germany).
Synchrotron-induced X-ray fluorescence (Sy-XRF) analysis was used to study the chemical composition of precious Renaissance silverpoint drawings. Drawings by famous artists such as Albrecht Dürer (14711528) and Jan van Eyck (approximately 13951441) must be investigated non-destructively. Moreover, extremely sensitive synchrotron- or accelerator-based techniques are needed since only small quantities of silver are deposited on the paper. New criteria for attributing these works to a particular artist could be established based on the analysis of the chemical composition of the metal points used. We illustrate how analysis can give new art historical information by means of two case studies. Two particular drawings, one of Albrecht Dürer, showing a profile portrait of his closest friend, Willibald Pirckheimer (1503), and a second one attributed to Jan van Eyck, showing a Portrait of an elderly man, often named Niccolò Albergati, are the object of intense art historical controversy. Both drawings show inscriptions next to the figures. Analyses by Sy-XRF could reveal the same kind of silverpoint for the Pirckheimer portrait and its mysterious Greek inscription, contrary to the drawing by Van Eyck where at least three different metal points were applied. Two different types of silver marks were found in this portrait. Silver containing gold marks were detected in the inscriptions and over-subscriptions. This is the first evidence of the use of gold points for metal point drawings in the Middle Ages.
Spatially resolved X-ray fluorescence analysis using synchrotron radiation (SR-XRF) at the wavelength shifter beamline, BAMline, at BESSY was used to investigate Renaissance silverpoint drawings as it is extremely sensitive, non-destructive and can be carried out in air using an excitation spot in the hundred micrometer range.
This paper deals with first results of the study of silverpoint drawings of Albrecht Dürer (14711528) belonging to the sketchbook that Albrecht Dürer used during a travel to the Netherlands in 1520/21. These results are compared to a PIXE study performed on drawings from the same sketchbook.
The minor element composition of the silverpoint used for the drawings in the sketchbook was (10.6 ± 3.5) wt.% of Cu and traces of Zn. Mercury was found in the marks but does not belong to the initial composition of the silverpoint as it is attributed to an alteration phenomenon. One drawing of the sketchbook represents an exception. It consists of silver marks containing an additional minor element, Zn, in the marks and was, therefore, created with another silverpoint, probably at a different time than the other drawings.
In this study, a multi-proxy approach combining 29Si, 27Al and 1H MAS-NMR, FEG-EPMA, XANES at the Cu K-edge and XRD analytics with hydrochemical tools such as ICP-OES analyses, oxygen-isotope signatures, and thermodynamic modelling was applied to K-silicate-activated metakaolin specimens - with and without CuSO4·5H2O addition - exposed to sulfuric acid at pH = 2 for 35 days. The results revealed a multistage deterioration mechanism governed by (i) acid diffusion, (ii) leaching of K-A-S-H, (iii) microstructural damage related to precipitation of expansive (K,Ca,Al)-sulfate-hydrate phases (iv) complete dissolution of the K-A-S-H framework, (v) and formation of silica gel in the outermost corroded regions. Copper ions were mainly located in layered spertiniite-chrysocolla-like phases in the as-cured materials. The results demonstrate an overall negative effect of Cu addition on chemical material durability, implying that the reported higher durability of Cu-doped AAM in biocorrosion environments can be best explained by bacteriostatic effects.
A core component of energy storage systems like vanadium redox flow batteries (VRFB) is the polymer electrolyte membrane (PEM). In this work, the frequently used perfluorosulfonic-acid (PFSA) membrane Nafion™ 117 and a novel poly (vinylidene difluoride) (PVDF)-based Membrane are investigated. A well-known problem in VRFBs is the vanadium permeation through the membrane. The consequence of this so-called vanadium crossover is a severe loss of capacity. For a
better understanding of vanadium transport in membranes, the uptake of vanadium ions from electrolytes containing Vdimer(IV–V) and for comparison also V(II), V(III), V(IV), and V(V) by both membranes was studied. UV/VIS spectroscopy, X-ray absorption near edge structure spectroscopy (XANES), total reflection X-ray fluorescence spectroscopy (TXRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and micro X-ray fluorescence spectroscopy (microXRF) were used to determine the vanadium concentrations and the species inside the membrane. The results strongly support that Vdimer(IV–V), a dimer formed from V(IV) and V(V), enters the nanoscopic water-body of Nafion™ 117 as such. This is interesting, because as of now, only the individual ions V(IV) and V(V) were considered to be transported through the membrane. Additionally, it was found that the Vdimer(IV–V) dimer partly dissociates to the individual ions in the novel PVDF-based membrane.
The Vdimer(IV–V) dimer concentration in Nafion™ was determined and compared to those of the other species. After three days of equilibration time, the concentration of the dimer is the lowest compared to the monomeric vanadium species. The concentration of vanadium in terms of the relative uptake λ = n(V)/n(SO3
) are as follows: V(II) [λ = 0.155] > V(III) [λ = 0.137] > V(IV) [λ = 0.124] > V(V) [λ = 0.053] > Vdimer(IV–V) [λ = 0.039]. The results show that the Vdimer(IV–V) dimer Needs to be considered in addition to the other monomeric species to properly describe the transport of vanadium through Nafion™ in VRFBs.