Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (26)
- Beitrag zu einem Tagungsband (5)
- Sonstiges (2)
- Forschungsbericht (2)
- Beitrag zu einem Sammelband (1)
- Posterpräsentation (1)
- Forschungsdatensatz (1)
Schlagworte
- Bottom ash (7)
- CONSENS (6)
- Online NMR Spectroscopy (5)
- Process Analytical Technology (5)
- Click Chemistry (3)
- Indirect Hard Modeling (3)
- Abfallverbrennung (2)
- Circular economy (2)
- Dry treatment (2)
- Emission (2)
Organisationseinheit der BAM
- 4 Material und Umwelt (14)
- 4.3 Schadstofftransfer und Umwelttechnologien (12)
- 1 Analytische Chemie; Referenzmaterialien (7)
- 1.4 Prozessanalytik (7)
- 8 Zerstörungsfreie Prüfung (3)
- 8.0 Abteilungsleitung und andere (3)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 8.6 Faseroptische Sensorik (1)
Die Autoren zeigen dazu die gesetzlichen und energiepolitischen Rahmenbedingungen und Perspektiven auf, widmen sich in aktuellen Beiträgen zur Verfahrenstechnik der thermischen Abfallbehandlung sowohl den thermischen Hauptverfahren als auch der Abgasreinigung und gehen auf das Thema Wertstoffrückgewinnung ein. Ihr Fazit: Durch Anstrengungen, das stoffliche Recycling weiter zu optimieren, können künftig weitere Kreisläufe von Produkten und Materialien hochwertig geschlossen werden. Für manche Abfallströme wird dies aber aus verschiedenen Gründen nicht möglich sein – hier bleibt die thermische Abfallbehandlung unverzichtbar.
Permeable reactive barriers (PRBs) offer an alternative as opposed to more cost-intensive active methods for groundwater remediation, e.g. pump-and-treat. Long-term performance of PRBs, however, is crucial for the technology’s success. The paper summarises the results of long-term column experiments with elemental iron (Fe0) and hydroxyapatite (HAP) as reactive materials for the removal of uranium from groundwater. Good removal results have been achieved using elemental iron with possible reaction paths being reductive precipitation and adsorption on to corrosion products of Fe0.
Die Mikro- und Nanotechnologie gehört zu den Schlüsseltechnologien des 21. Jahrhunderts mit hohen Wachstumsprognosen, wie auch die im Auftrag des BMBF durchgeführte Studie “Nanotechnologie als wirtschaftlicher Wachstumsmarkt” von 2004 ausführlich darstellt. Aus diesem Trend resultiert ein steigender Bedarf an Messsystemen, die Nanostrukturen prozessnah bzw. im Fertigungsprozess charakterisieren können. Virtuelle Messgeräte liefern Erkenntnisse zur Entwicklung neuartiger Messsysteme, Analyse und Optimierung bestehender Verfahren sowie die Bestimmung der Messunsicherheit und modellbasierten Korrektur systematischer Fehler. Der virtuelle Messprozess umfasst neben dem Messmittel auch die Probe und die Wechselwirkungen zwischen beiden. In diesem Beitrag werden virtuelle Messgeräte vorgestellt sowie deren Anwendung diskutiert.
Studies by Synchrotron Radiation-X-Ray Fluorescence (SR-XRF) for the search of the presence of trace elements like Sb, Sn, Te and Pb in archaeological metallic objects found on the territory of Romania-old coins and Bronze Age jewelry, aimed to determine the provenance of the gold used in their manufacture. The results are compared with the detailed elemental composition of alluvial or primary gold samples, obtained by the same technique. This work attempted to establish the origin of the gold used for the mint of two different types of koson coins. We found that the kosons with monogram are made of refined gold, while the one used for the kosons without monogram is mainly alluvial. The gold used in the manufacture of the Calarasi Vulchitrun-type disk and the Tauteu hair ring is also of alluvial origin.
Warum eine Kreislaufwirtschaft ohne Abfallverbrennung nicht funktionieren wird, beschreibt die Dechema im Positionspapier „Abfallverbrennung in der Zukunft“. Experten der Fachgruppe „Abfallbehandlung und Wertstoffrückgewinnung“ von ProcessNet, einer gemeinsamen Initiative der Dechema und der VDI-Gesellschaft Verfahrenstechnik und Chemieingenieurwesen, haben es erstellt.
The possible impact of ultrafine particles from laser printers on human health is controversially discussed although there are persons reporting substantial symptoms in relation to these emissions. A randomized, single-blinded, cross-over experimental design with two exposure conditions (high-level and low-level exposure) was conducted with 23 healthy subjects, 14 subjects with mild asthma, and 15 persons reporting symptoms associated with laser printer emissions. To separate physiological and psychological effects, a secondary physiologically based categorization of susceptibility to particle effects was used. In line with results from physiological and biochemical assessments, we found no coherent, differential, or clinically relevant effects of different exposure conditions on subjective complaints and cognitive performance in terms of attention, short-term memory, and psychomotor performance. However, results regarding the psychological characteristics of participants and their situational perception confirm differences between the participants groups: Subjects reporting symptoms associated with laser printer emissions showed a higher psychological susceptibility for adverse reactions in line with previous results on persons with multiple chemical sensitivity or idiopathic environmental intolerance. In conclusion, acute psychological and cognitive effects of laser printer emissions were small and could be attributed only to different participant groups but not to differences in exposure conditions in terms of particle number concentrations.
Modular plants using intensified continuous processes represent an appealing concept to produce pharmaceuticals. It can improve quality, safety, sustainability, and profitability compared to batch processes, and it enables plug-and-produce reconfiguration for fast product changes. To facilitate this flexibility by real-time quality control, we developed a solution that can be adapted quickly to new processes and includes a compact Nuclear Magnetic Resonance (NMR) spectrometer for online quality monitoring as well as a new model-based control approach. The NMR sensor is a benchtop device enhanced to the requirements of automated chemical production including ro-bust evaluation of sensor data.
Here, we present alternatives for the quantitative determination of the analytes using modular, physically motivated models. These models can be adapted to new substances solely by the use of their corresponding pure component spectra, which can either be derived from experimental spectra as well as from quantum mechanical models or NMR predictors. Modular means that spec-tral models can simply be exchanged together with alternate reagents and products. Beyond that, we comprehensively calibrated an NIR spectrometer based on online NMR process data for the first time within an industrial plant. The integrated solution was developed for a metal organic reac-tion running on a commercial-scale modular pilot plant and it was tested under industrial conditions.
In case study one of the CONSENS project, two aromatic substances were coupled by a lithiation reaction, which is a prominent example in pharmaceutical industry. The two aromatic reactants (Aniline and o-FNB) were mixed with Lithium-base (LiHMDS) in a continuous modular plant to produce the desired product (Li-NDPA) and a salt (LiF). The salt precipitates which leads to the formation of particles. The feed streams were subject to variation to drive the plant to its optimum.
The uploaded data comprises the results from four days during continuous plant operation time. Each day is denoted from day 1-4 and represents the dates 2017-09-26, 2017-09-28, 2017-10-10, 2017-10-17.
In the following the contents of the files are explained.
Ultrafine particles emitted from laser printers are suspected to elicit adverse health effects. We performed 75-minute exposures to emissions of laser printing devices (LPDs) in a standardized, randomized, cross- over manner in 23 healthy subjects, 14 mild, stable asthmatics, and 15 persons reporting symptoms associated with LPD emissions. Low-level exposures (LLE) ranged at the particle background (3000 cm−3) and High-level exposures (HLE) at 100 000 cm−3. Examinations before and after exp sures included spirometry, body plethysmography, transfer factors for CO and NO (TLCO, TLNO), bronchial and alveolar NO, cytokines in serum and nasal secretions (IL-1β, IL-5, IL-6, IL-8, GM-CSF, IFNγ, TNFα), serum ECP, and IgE. Across all participants, no statistically significant changes occurred for lung mechanics and NO. There was a decrease in volume-related TLNO that was more pronounced in HLE, but the difference to LLE was not significant. ECP and IgE increased in the same way after exposures. Nasal IL-6 showed a higher increase after LLE. There was no coherent pattern regarding the responses in the participant subgroups or single sets of variables. In conclusion, the experimental acute responses to short but very high-level LPD exposures were small and did not indicate clinically relevant effects compared to low particle number concentrations.
The classification of solid oxidizers according to the GHS (Globally Harmonized System of Classifica-tion and Labelling of Chemicals) and according to regulations on the transport of dangerous goods (based on the UN Recommendations/Model Regulations and implemented in all carrier domains as transport by road, railway, sea, air) is performed on the basis of the results of the UN test O.1 (―Test for oxidizing solids‖ described in chapter 34.4.1 in the Recommendations on the Transport of Danger-ous Goods, Manual of Tests and Criteria, Fifth revised edition, United Nations, New York and Geneva, 2009). This test was introduced into the UN Test Manual in 1995 as a replacement for a similar test from 1986. Even though the O.1 test is much better than the previous one there are still many prob-lems with this test. For this reason the IGUS-EOS working group (international group of experts on the explosion risks of unstable substances – working group: energetic and oxidizing substances) installed an ad-hoc working group in 2002 assigned with the task of proposing solutions for the existing prob-lems. The adequacy of such proposals has to be proven preferably by interlaboratory comparison (interlaboratory test) before they are presented to the UN Sub Committee for adoption into the UN Test Manual. The present report is the evaluation of an interlaboratory test which was designed by the Ad-hoc working group in order to find out whether the current method of comparing combustion times of test mixtures with those of reference mixtures is suitable in principle and whether some approaches for improvement of the method can be identified.