Magnetic Bead-Based Immunoassays for Online Sensing Applications

  • The demand for quick and reliable online sensors is rising not only in the field of environmental analysis with new and diversifying sources of pollution. A major aspect of this is the contamination of (drinking) water with pharmaceuticals representing a potential health threat and requiring timely countermeasures in case of contamination. In this regard, antibody-based methods can be helpful as they enable fast and cost-effective on-site and potentially online analyses. The transition from the conventional plate-based formats like ELISA (enzyme-linked immunosorbent assay) to an immunosensor fit for online sensing can be achieved by using magnetic microparticles as a mobile sensing platform. Beads are prepared by either coupling the antibody or the analyte to the surface. Both these strategies are presented using the example of two relevant contaminants in water: diclofenac (DCF) & amoxicillin (AMX), and can be transferred to other analytes. The developed magnetic bead-based assaysThe demand for quick and reliable online sensors is rising not only in the field of environmental analysis with new and diversifying sources of pollution. A major aspect of this is the contamination of (drinking) water with pharmaceuticals representing a potential health threat and requiring timely countermeasures in case of contamination. In this regard, antibody-based methods can be helpful as they enable fast and cost-effective on-site and potentially online analyses. The transition from the conventional plate-based formats like ELISA (enzyme-linked immunosorbent assay) to an immunosensor fit for online sensing can be achieved by using magnetic microparticles as a mobile sensing platform. Beads are prepared by either coupling the antibody or the analyte to the surface. Both these strategies are presented using the example of two relevant contaminants in water: diclofenac (DCF) & amoxicillin (AMX), and can be transferred to other analytes. The developed magnetic bead-based assays (MBBAs) exhibit lower LODs, enhanced sensitivity as well as shorter time of analysis than the respective ELISAs and can be integrated into an immunosensor with electrochemical detection on a microfluidic chip.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • PS3-19_Alexander Ecke.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Alexander EckeORCiD
Koautor*innen:Konrad Bohm, Rudolf Schneider
Dokumenttyp:Posterpräsentation
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2021
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.8 Umweltanalytik
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik
Freie Schlagwörter:Amoxicillin; Diclofenac; Immunoassay; Magnetic Beads; Online Sensing
Themenfelder/Aktivitätsfelder der BAM:Umwelt
Veranstaltung:European Biosensor Symposium 2021
Veranstaltungsort:Online meeting
Beginndatum der Veranstaltung:09.03.2021
Enddatum der Veranstaltung:12.03.2021
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:17.03.2021
Referierte Publikation:Nein