Filtern
Dokumenttyp
- Posterpräsentation (10)
- Zeitschriftenartikel (5)
- Vortrag (3)
- Beitrag zu einem Tagungsband (1)
- Dissertation (1)
Sprache
- Englisch (15)
- Deutsch (4)
- Mehrsprachig (1)
Schlagworte
- Amoxicillin (16)
- Immunoassay (13)
- Diclofenac (11)
- Immunosensor (8)
- Magnetic Beads (6)
- Magnetpartikel (4)
- Water Analysis (4)
- LC-MS/MS (3)
- Microfluidics (3)
- Antibiotics (2)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (3)
The environmental fate of the frequently used broad-spectrum β-lactam antibiotic amoxicillin (AMX) is of high concern regarding the potential evolution of antimicrobial resistance (AMR). Moreover, it is known that AMX is prone to hydrolysis, yielding a variety of hydrolysis products (HPs) with yet unknown effects. Studies to identify those HPs and investigate their formation mechanisms have been reported but a long-term study on their stability in real water samples was missing. In this regard, we investigated the hydrolysis of AMX at two concentration levels in four distinct water types under three different storage conditions over two months. Concentrations of AMX and four relevant HPs were monitored by an LC-MS/MS method revealing pronounced differences in the hydrolysis rate of AMX in tap water and mineral water on the one hand (fast) and surface water on the other(slow). In this context, the occurrence, relative intensities, and stability of certain HPs are more dependent on the water type than on the storage condition. As clarified by ICP-MS, the main difference between the water types was the content of the metals copper and zinc which are supposed to catalyze AMX hydrolysis demonstrating an effective method to degrade AMX at ambient conditions.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays (MBBAs) allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays (MBBAs) allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast and cost-effective on-site analyses. Magnetic bead-based immunoassays allow for implementation into an immunosensor for online testing. These particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Der Bedarf nach schnellen und kostengünstigen Analysemethoden in der (Trink-)Wasseranalytik steigt mit dem zunehmenden Eintrag pharmazeutisch aktiver Substanzen in die Umwelt.
Insbesondere die Kontamination mit Antibiotika erscheint neben ökotoxikologischen Effekten vor allem in Hinblick auf die Evolution resistenter Keime im Wasser besorgniserregend.
Wir berichten hier über die Entwicklung eines magnetpartikelbasierten Immunoassays (MBBA) zur Detektion des Breitbandantibiotikums Amoxicillin (AMX) in Wasserproben, der im Vergleich zum entsprechenden Enzyme-linked Immunosorbent Assay (ELISA) eine wesentlich kürzere Analysendauer sowie einen breiteren Messbereich mit niedrigerer Nachweisgrenze aufweist. Das angewendete Assayprinzip ist dabei leicht auf weitere Analyten übertragbar und ermöglicht die Implementierung in einen Immunosensor.
Die zunehmende Kontamination von (Trink)-Wasser mit pharmazeutischen Rückständen stellt ein potenzielles Gesundheitsrisiko dar und verlangt nach schnellen und zuverlässigen Analysemethoden. Hierbei können antikörper-basierte Methoden helfen, da sie schnelle und kostengünstige Vor-Ort-Messungen sowie Onlineanalysen ermöglichen.
Der Übergang von konventionellen plattenbasierten Formaten, wie ELISA (Enzyme-linked Immunosorbent Assay), zu einem Immunosensor für Online-Messungen wird durch den Einsatz magnetischer Mikropartikel als mobile Messplattform ermöglicht.
Die Partikel werden dazu entweder mit dem Antikörper oder dem Analyten gekoppelt. Diese beiden Strategien werden am Beispiel zweier relevanter Kontaminanten des Wassers gezeigt: Diclofenac (DCF) & Amoxicillin (AMX), und sind leicht auf andere Analyten übertragbar. Die magnetpartikelbasierten Assays (MBBAs) weisen niedrigere Nachweisgrenzen, breitere Messbereiche sowie kürzere Analysezeiten als die entsprechenden ELISAs auf und können in einen Immunosensor mit elektrochemischer Detektion auf einem mikrofluidischen Chip integriert werden.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Contamination of the environment with antibiotics is of great concern as it promotes the evolution of antimicrobial resistances. In case of amoxicillin (AMX) in the aquatic environment, further risk arises from hydrolysis products (HPs) which can cause allergy. To assess these risks, a comprehensive investigation and understanding of the degradation of AMX is necessary. We investigated the hydrolysis rate of AMX in different types of water as well as the influence of temperature and irradiation. The content of the heavy metal ions copper and zinc was found to be crucial for the hydrolysis rate of AMX and stability of HPs. Eventually, a new degradation pathway for AMX could be elaborated and confirmed by tandem mass spectrometry (LC-MS/MS).
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays (MBBAs) allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.