• Treffer 2 von 92
Zurück zur Trefferliste

Characterization of sterilized nanoparticles by lab-based XPS and HAXPES

  • The novel lab-based HAXPES spectrometer (ULVAC-PHI Quantes) gives us the possibility to measure XPS at 1486.6 eV (monochromatic Al Kα source) and HAXPES at 5414.9 eV (monochromatic Cr Kα source) on a sample at the same position. The surface analysis with this spectrometer leads to an information depth of about 10 nm for XPS and in comparison, to an analysis of deeper regions of about 30 nm for HAXPES measurements. This method provides a nondestructive way to distinguish between the near-surface region of the nanoparticles and the whole nanoparticle. Additionally, HAXPES gives access to deeper core levels at higher energy. An application of this technique is presented using nanoparticles. The results shown were obtained with nanoparticles, that were treated differently by means of sterilization for nanosafety (i.e., before studying their toxicity it is important to establish whether nanomaterials are sterile and, if not, to be treated either via microwave or autoclave sterilisation).The novel lab-based HAXPES spectrometer (ULVAC-PHI Quantes) gives us the possibility to measure XPS at 1486.6 eV (monochromatic Al Kα source) and HAXPES at 5414.9 eV (monochromatic Cr Kα source) on a sample at the same position. The surface analysis with this spectrometer leads to an information depth of about 10 nm for XPS and in comparison, to an analysis of deeper regions of about 30 nm for HAXPES measurements. This method provides a nondestructive way to distinguish between the near-surface region of the nanoparticles and the whole nanoparticle. Additionally, HAXPES gives access to deeper core levels at higher energy. An application of this technique is presented using nanoparticles. The results shown were obtained with nanoparticles, that were treated differently by means of sterilization for nanosafety (i.e., before studying their toxicity it is important to establish whether nanomaterials are sterile and, if not, to be treated either via microwave or autoclave sterilisation). As a complementary method, the data is compared with SEM and EDX measurements. All methods demonstrate the influence of sterilization. More specifically, these results show that the sterilization step must be considered in the physical-chemical description of the particles for establishing reliable (quantitative structure-activity) relationships.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Ecasia2022_Knigge.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Xenia KniggeORCiD
Koautor*innen:Z. Guo, E. Valsami-Jones, Jörg Radnik
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2022
Organisationseinheit der BAM:6 Materialchemie
6 Materialchemie / 6.1 Oberflächen- und Dünnschichtanalyse
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Freie Schlagwörter:HAXPES; Nanoparticles; XPS
Themenfelder/Aktivitätsfelder der BAM:Material
Material / Nano
Veranstaltung:ECASIA 2022
Veranstaltungsort:Limerick, Ireland
Beginndatum der Veranstaltung:29.05.2022
Enddatum der Veranstaltung:03.06.2022
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:09.06.2022
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden