Reproducibly emitting reference materials for volatile and semi-volatile organic compounds—using finite element modeling for emission predictions
- Recent research into emissions of (semi-)volatile organic compounds [(S)VOC] from solid materials has focused on the development of suitable reference materials for quality assurance/quality control of emission test chamber measurements, which fulfill requirements such as homogenous and reproducible (S)VOC release. The approach of this study was to find a method for preparation of a material with predictable (S)VOC emission rates. AVOC (styrene) and an SVOC (2,6-diisopropylnaphthalene, DIPN), loaded into either vacuum grease or a 1:1 mixture of paraffin/squalane, have been tested. For the prediction of the emission rates, a model using the finite element method (FEM) was created to simulate the (S)VOC emission profiles. Theoretical and experimental results obtained in a Micro-Chamber/Thermal Extractor (μ-CTE™) and in 24 L emission test chamber measurements were in good agreement. Further properties were investigated concerning the material applicability, such as shelf life andRecent research into emissions of (semi-)volatile organic compounds [(S)VOC] from solid materials has focused on the development of suitable reference materials for quality assurance/quality control of emission test chamber measurements, which fulfill requirements such as homogenous and reproducible (S)VOC release. The approach of this study was to find a method for preparation of a material with predictable (S)VOC emission rates. AVOC (styrene) and an SVOC (2,6-diisopropylnaphthalene, DIPN), loaded into either vacuum grease or a 1:1 mixture of paraffin/squalane, have been tested. For the prediction of the emission rates, a model using the finite element method (FEM) was created to simulate the (S)VOC emission profiles. Theoretical and experimental results obtained in a Micro-Chamber/Thermal Extractor (μ-CTE™) and in 24 L emission test chamber measurements were in good agreement. Further properties were investigated concerning the material applicability, such as shelf life and inter-laboratory comparability. The maximum relative standard deviation in the inter-laboratory study was found to be 20%.…
Autor*innen: | Birte Mull, T. Sauerwald, C. Schultealbert, Wolfgang HornORCiD, Doris Brödner, Matthias RichterORCiD |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Verlagsliteratur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Air Quality, Atmosphere and Health |
Jahr der Erstveröffentlichung: | 2017 |
Verlag: | Springer Science+Business Media B.V. |
Jahrgang/Band: | 10 |
Ausgabe/Heft: | 10 |
Erste Seite: | 1237 |
Letzte Seite: | 1246 |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik | |
Freie Schlagwörter: | Emission test chamber; Emitting reference material; FEM model; Micro-chamber |
DOI: | 10.1007/s11869-017-0508-6 |