Zitieren Sie bitte immer diesen URN: urn:nbn:de:kobv:b43-473486
Visibility of Image Quality Indicators (IQI) by Human Observers in Digital Radiography in Dependence on Measured MTFs and Noise Power Spectra
- Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. InDigital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised.…
Autor*innen: | Uwe Ewert, Uwe ZscherpelORCiD, Justus Vogel, F. Zhang, N.X. Long, T.P. Nguyen |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Graue Literatur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | The e-journal of nondestructive testing & ultrasonics |
Jahr der Erstveröffentlichung: | 2018 |
Organisationseinheit der BAM: | 8 Zerstörungsfreie Prüfung |
8 Zerstörungsfreie Prüfung / 8.0 Abteilungsleitung und andere | |
Veröffentlichende Institution: | Bundesanstalt für Materialforschung und -prüfung (BAM) |
Verlag: | NDT.net |
Verlagsort: | Kirchwald |
Jahrgang/Band: | 23 |
Ausgabe/Heft: | 8 |
Aufsatznummer: | 22967 |
Erste Seite: | 1 |
Letzte Seite: | 7 |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Freie Schlagwörter: | Computed radiography (CR); Detail detection; Digital Detector Array (DDA); Image evaluation |
Themenfelder/Aktivitätsfelder der BAM: | Chemie und Prozesstechnik |
Veranstaltung: | 12th ECNDT 2018 |
Veranstaltungsort: | Gothenburg, Sweden |
Beginndatum der Veranstaltung: | 11.06.2018 |
Enddatum der Veranstaltung: | 15.06.2018 |
URN: | urn:nbn:de:kobv:b43-473486 |
URL: | http://www.ndt.net/?id=22967 |
ISSN: | 1435-4934 |
Verfügbarkeit des Dokuments: | Datei für die Öffentlichkeit verfügbar ("Open Access") |
Lizenz (Deutsch): | Creative Commons - CC BY-NC - Namensnennung - Nicht kommerziell 4.0 International |
Datum der Freischaltung: | 11.02.2019 |
Referierte Publikation: | Nein |
Schriftenreihen ohne Nummerierung: | Wissenschaftliche Artikel der BAM |