• Treffer 2 von 2
Zurück zur Trefferliste

Measuring moisture in building material - an overview

  • In Germany there is an existing built infrastructure worth about 50 trillion Euros. The expected lifetimes of individual structures are up to 100 years. Considerable costs (annually about 35 billion Euros, the trend continues upwards) are involved in order to maintain and rehabilitate both residential as well as transportation infrastructure buildings. Most damages we observe on our built infrastructure are moisture-induced processes. Consequently reliable moisture measurement tools a highly needed for meaningful building diagnosis investigations. The optimal moisture measuring technique would be non-destructive, fast, repeatable, reliable, independent of steel in the vicinity, the surface condition or possible salt loads of the material under test. Since this is unfortunately not the case for any non-destructive method, it is often very difficult to decide for users which method to use for the particular testing problem. The only standardized methods in Germany are the “direct” andIn Germany there is an existing built infrastructure worth about 50 trillion Euros. The expected lifetimes of individual structures are up to 100 years. Considerable costs (annually about 35 billion Euros, the trend continues upwards) are involved in order to maintain and rehabilitate both residential as well as transportation infrastructure buildings. Most damages we observe on our built infrastructure are moisture-induced processes. Consequently reliable moisture measurement tools a highly needed for meaningful building diagnosis investigations. The optimal moisture measuring technique would be non-destructive, fast, repeatable, reliable, independent of steel in the vicinity, the surface condition or possible salt loads of the material under test. Since this is unfortunately not the case for any non-destructive method, it is often very difficult to decide for users which method to use for the particular testing problem. The only standardized methods in Germany are the “direct” and destructive Darr- and the CM tests. Although they can be highly accurate (when handled with care during the sampling), they deliver only punctual information and cannot be used for monitoring. The other, non-destructive methods are based on the change in humidity-dependent physical material properties. The underlying physics, their particular advantages and disadvantages are discussed in this paper.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Kruschwitz_ndt_moisture_techniques_split.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Sabine KruschwitzORCiD
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2016
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Electrical methods; Microwave; Moisture measuring; Non-destructive methods
Veranstaltung:Building Safety Symposium
Veranstaltungsort:Hong Kong, China
Beginndatum der Veranstaltung:22.04.2016
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:11.08.2016
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden