Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (367) (entfernen)
Sprache
- Englisch (367) (entfernen)
Schlagworte
- Fluorescence (22)
- ICP-MS (21)
- Mass spectrometry (18)
- Nanoparticle (17)
- Laser ablation (16)
- Quality assurance (13)
- BAMline (10)
- Imaging (10)
- Quantum yield (10)
- Synchrotron (10)
- Cancer (9)
- Mycotoxins (9)
- Traceability (9)
- Calibration (8)
- Cell (8)
- Luminescence (8)
- MALDI-TOF MS (8)
- Mass-Spectrometry (8)
- Metrology (8)
- Reference material (8)
- Lifetime (7)
- Mechanochemistry (7)
- Microplastics (7)
- Quantitative spectroscopy (7)
- Immunoassay (6)
- Microplastic (6)
- Nano (6)
- TED-GC/MS (6)
- Analytical Chemistry (5)
- Dye (5)
- Electrochemistry (5)
- Energy transfer (5)
- Food (5)
- LA-ICP-MS (5)
- LC-MS/MS (5)
- Magnetic resonance imaging (5)
- Mass Spectrometry (5)
- Metabolomics (5)
- PFAS (5)
- Particle (5)
- Polylactide (5)
- Reproducibility (5)
- Spectroscopy (5)
- Synthesis (5)
- Transformation products (5)
- Uncertainty (5)
- XRF (5)
- Automation (4)
- CCQM (4)
- Copper (4)
- Food analysis (4)
- HRMS (4)
- Human serum (4)
- Immunohistochemistry (4)
- In situ (4)
- Industry 4.0 (4)
- Interlaboratory comparison (4)
- Isotope dilution (4)
- LIBS (4)
- Nanoparticles (4)
- Sulfur (4)
- Tumor metabolism (4)
- XRD (4)
- Absolute isotope ratio (3)
- Acoustic levitation (3)
- Adsorption (3)
- Bioconjugation (3)
- Bioimaging (3)
- Brain (3)
- CONSENS (3)
- CRM (3)
- Cement (3)
- ELISA (3)
- Ergot alkaloids (3)
- Fatty acid metabolism (3)
- GDMS (3)
- Gadolinium (3)
- Gas chromatography (3)
- HPLC (3)
- HR-CS-MAS (3)
- Lanthanide (3)
- Lipidomic profile (3)
- MC-ICP-MS (3)
- Mass Spectroscopy (3)
- Measurement uncertainty (3)
- Metabolic stress (3)
- Method (3)
- Modular Production (3)
- Mycotoxin (3)
- Nanomaterials (3)
- Probe (3)
- Process Analytical Technology (3)
- Purity assessment (3)
- Quality control (3)
- Sensor (3)
- Soil (3)
- AAS (2)
- Abwasser (2)
- Affinity chromatography (2)
- Amino acid analysis (2)
- Amperometry (2)
- Amplification (2)
- Antibody (2)
- Aromatic amino acid analysis (2)
- Array (2)
- Artificial neural networks (2)
- BODIPY (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Biomarker (2)
- Biosensing (2)
- CXC (2)
- Cells (2)
- Certified reference material (2)
- Chlorine (2)
- Chromatography (2)
- Cocoa (2)
- Combustion ion chromatography (CIC) (2)
- Conjugate (2)
- Core-shell particles (2)
- Crystalinity (2)
- Crystallization (2)
- Cyclization (2)
- Degradation (2)
- Delta value (2)
- Derivatization (2)
- Diagnosis (2)
- Diagnostics (2)
- Diatoms (2)
- Diclofenac (2)
- Electrocatalysis (2)
- Environmental speciation (2)
- Epoxy (2)
- Extracellular matrix (2)
- Extractable organically bound fluorine (EOF) (2)
- Fluorine (2)
- GD-OES (2)
- Gas chromatography (GC) (2)
- General Earth and Planetary Sciences (2)
- General Materials Science (2)
- Graphite furnace (2)
- HPLC-MS/MS (2)
- Heart failure (2)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (2)
- Hydrazinolysis (2)
- Hydrogen (2)
- Hydrolysis (2)
- ILC (2)
- Iron (2)
- Isotope (2)
- Isotope dilution (ID) (2)
- Isotope dilution mass spectrometry (2)
- Isotope ratio (2)
- Isotope ratios (2)
- Isotopic fractionation (2)
- Li-ion battery (2)
- Lipidomics (2)
- Liquid chromatography (2)
- Liquid chromatography (LC) (2)
- Lithium (2)
- MALDI (2)
- MALDI TOF MS (2)
- MRI (2)
- MYCN (2)
- Machine learning (2)
- Magnetic beads (2)
- Mass spectrometry (MS) (2)
- Mercury (2)
- Metals (2)
- Method development (2)
- Mobile phase (2)
- Molar mass (2)
- Molecularly imprinted polymers (2)
- Multimodal (2)
- Nanopartikel (2)
- Nickel (2)
- Nitrotyrosine (2)
- Online NMR spectroscopy (2)
- Oxygen sensor (2)
- Peptide analysis (2)
- Peptide library (2)
- Permethrin (2)
- Pesticide (2)
- Phenylalanine (2)
- Photodegradation (2)
- Plasma (2)
- Plasma modeling (2)
- Pollen (2)
- Polycyclic aromatic hydrocarbon (PAH) (2)
- Polymer (2)
- Process analytical technology (2)
- Purity (2)
- Quantification (2)
- Quantitative protein analysis (2)
- R package (2)
- Raman (2)
- Real-time process monitoring (2)
- Reference materials (2)
- SAXS (2)
- SBA-15 (2)
- SERS (2)
- SI (2)
- SI traceability (2)
- Screening (2)
- Single particle ICP-MS (2)
- Sr isotopes (2)
- Standardization (2)
- Surface water (2)
- TGA-FTIR (2)
- Tire wear (2)
- Transformation product (2)
- Triple isotope fractionation (2)
- Tyrosine (2)
- VOC (2)
- Validation (2)
- Volatile organic compounds (2)
- Wastewater (2)
- Water (2)
- XANES (2)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 2-propanol oxidation (1)
- 280 nm (1)
- 3D ultrastructural analysis (1)
- 3D-printing (1)
- 5-Bromouracil (1)
- 6xHis (1)
- A4F (1)
- AAA (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- AF4 (1)
- AFM (1)
- AG nanoparticle (1)
- ANOVA (1)
- ATCUN (1)
- AU nanoparticle (1)
- Absorption spectrometry (1)
- Accuracy (1)
- Acidic oxygen evolution reaction (1)
- Acoustic (1)
- Acrylamide (1)
- Acute myocardial infarction (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Advanced nanomaterials (1)
- Aeroacoustics (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity extraction (1)
- Aflatoxins (1)
- Air analysis (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air-coupled ultrasound (1)
- Airport (1)
- Akaike information criterion picker (1)
- AlCl (1)
- Albumin (1)
- Alcohol electrooxidation (1)
- Algorithms (1)
- Allergy (1)
- Altenuene (1)
- Alternaria mycotoxins (1)
- Aluminium (1)
- Aluminum (1)
- Aluminum alloys (1)
- Aluminum oxide (1)
- Alzheimer’s disease (1)
- Ambient pressure laser ionization (1)
- Amyloid (1)
- Amyloid-beta (1)
- Analysis (1)
- Analytical chemistry (1)
- Analytical methods (1)
- Anemia (1)
- Anilinopyridine (1)
- Anion receptors (1)
- Annealing (1)
- Antagonists (1)
- Anthropocene (1)
- Antibody Purification (1)
- Antibody antigen complex (1)
- Antibody conjugates (1)
- Antibody identification (1)
- Antibody quality (1)
- Antibody quantification (1)
- Antibody-gated indicator delivery (1)
- Antifouling biocides (1)
- Antikensammlung Berlin (1)
- Antikörper (1)
- App (1)
- Archaeometry (1)
- Arsenite (1)
- Artificial Neural Networks (1)
- Aspergillus (1)
- Asymmetrical flow field flow fractionation (AF4) (1)
- Atmospheric aerosol (1)
- Atomic Absorption Spectrometry (1)
- Atomic Force Microscopy (1)
- Atomic absorption spectrometry (1)
- Atomic and molecular physics, and optics (1)
- Atomic layer deposition (1)
- Augmented data (1)
- Automated Purification (1)
- Automated image analysis (1)
- Automated system (1)
- Automatisierung (1)
- Autophagy (1)
- Aviation (1)
- Avogadro constant (1)
- BCA test (1)
- BERM (1)
- BLE Bluetooth low energy (1)
- BPA removal (1)
- Back-side integration (1)
- Bacterial lysates (1)
- Bakterien (1)
- Barium (1)
- Basic solvent (1)
- Battery (1)
- Bawit (1)
- Bbeverages (1)
- Bead injection spectroscopy (1)
- Bead-based assay (1)
- Benchtop NMR Spectroscopy (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Binder (1)
- Binding strength (1)
- Bio-interaction (1)
- Bioactive glass (1)
- Bioapatite (1)
- Biochemistry (1)
- Biochip (1)
- Biodiesel fuel (1)
- Biogenic carbonates (1)
- Bioinformatics (1)
- Biological & biomedical applications (1)
- Biological boron recycling (1)
- Biopolymers Probes (1)
- Biosensor (1)
- Biosensors (1)
- Bioseparation (1)
- Biosilicification (1)
- Biosynthesis (1)
- Biotests (1)
- Biotransformation (1)
- Bismuth (1)
- Bisphenol A (1)
- Bisphenol-A (1)
- Block copolymer (1)
- Blood-brain barrier (1)
- Bombs (1)
- Bone matrix (1)
- Boron isotope (1)
- Boron isotope fractionation (1)
- Boron isotopic composition (1)
- Borosilicate Glass (1)
- Borosilicate glass (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Brassica napus (1)
- Breath (1)
- Byproducts (1)
- CCQM key comparison (1)
- CE/MC-ICP-MS (1)
- COVID-19 (1)
- CRP (1)
- CT simulation (1)
- CaCl emission bands (1)
- Cadmium (1)
- Calcification (1)
- Calcium (1)
- Calcium monofluoride (1)
- Cancer awareness measure (1)
- Cancer cells (1)
- Cancer risk (1)
- Cancer therapy (1)
- Canine olfactometry (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis (CE) (1)
- Capillary electrophoresis-mass spectrometry (1)
- Carbodiimide crosslinking (1)
- Carboxyl group (1)
- Cardiac troponin (1)
- Cardiolipins (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier gas hot extraction (1)
- Catalysts (1)
- Cathode material (1)
- Cconventional method (1)
- CdSe/ZnS quantum Dots (1)
- Cellular trafficking (1)
- Cellular uptake (1)
- Central Taurus (1)
- Certification (1)
- Charge Transfer (1)
- Chemical Process Control (1)
- Chemical Safety (1)
- Chemical protein modification (1)
- Chemical sensors (1)
- Chemical transformation (1)
- Chemiluminescence (1)
- Chenopodium album (1)
- Chicken antibodies (1)
- Chlorides (1)
- Chlorine determination (1)
- Chronic kidney disease (1)
- Citizen Science (1)
- Classical primary measurement method (CPM) (1)
- Classification (1)
- Cleaning (1)
- Cleavage (1)
- Climate (1)
- Clinical Biochemistry (1)
- Clone M2 (1)
- Cluster (1)
- Cobalt deposition (1)
- Coded Aperture (1)
- Colorimetric Test (1)
- Column holder (1)
- Combustion (1)
- Combustion ion chromatography (1)
- Comparability (1)
- Competitive immunoassay (1)
- Complementary MS (1)
- Complex (1)
- Complexation (1)
- Compost (1)
- Compound-independent calibration (1)
- Computed tomography (1)
- Comsumer good samples (1)
- Concentration step (1)
- Confocal laser scanning microscopy (1)
- Construction (1)
- Consumer Products (1)
- Continuous Sensor (1)
- Continuous processes (1)
- Contrast agent (1)
- Conventional isotope ratio (1)
- Converter material (1)
- Coordination polymers (1)
- Coptic manuscripts (1)
- Corona virus (1)
- Corophium volutator (1)
- Corrosion (1)
- Coulometric sensors (1)
- Coumarin (1)
- Coupling reactions (1)
- Cr(III) (1)
- Cr(III) complex (1)
- Cryo-soft X-ray tomography (1)
- Cryoadsorption (1)
- Cyanide (1)
- Cyanide in soil (1)
- Cyber-Physical Systems (1)
- Cyber-physical system (1)
- Cyber-physical systems (1)
- Cyclic voltammetry (1)
- Cycloparaphenylenes (1)
- Cytoplasm (1)
- Cytoplasmic remodeling (1)
- D-glucose (1)
- D2XRF (1)
- DC-Arc (1)
- DEA (1)
- DHAP (1)
- DNA (1)
- DNA origami (1)
- DNA radiation damage (1)
- DNA strand breaks (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Data Analysis (1)
- Data Fusion (1)
- Data processing (1)
- Debromination (1)
- Debye-Waller parameter (1)
- Delta scale (1)
- Dendrite growth (1)
- Dendritic polyglycerol sulfate (1)
- Density functional theory (1)
- Density separation (1)
- Depht profiling (1)
- Depth profile (1)
- Deuterium (1)
- Deuterium enriched water (1)
- Diagenesis (1)
- Diagnostic Antibodies (1)
- Diastolic dysfunction (1)
- Diatomic molecule (1)
- Diesel exhaust (1)
- Diffusion (1)
- Digestion (1)
- Digital Transformation (1)
- Digital twins (1)
- Digitale Transformation (1)
- Digitalisation (1)
- Dimerization (1)
- Dip-stick assay (1)
- Direct alcohol fuel cells (1)
- Direct metal assay (1)
- Dispersive-XAS (1)
- Dissociation constant (1)
- Dissolution (1)
- Dityrosine (1)
- Down Stream Processing (1)
- Downstream processing (1)
- Dried fig (1)
- Droplets (1)
- Drug Discovery (1)
- Drug transporters (1)
- Duplex stainless steels (1)
- Dye monomers (1)
- Dyes/pigments (1)
- E. coli (1)
- EC/LC/MS (1)
- EC/MS (1)
- ECR (1)
- EDTAD (1)
- EPMA (1)
- EPR spectroscopy (1)
- ESEM (1)
- ESMA (1)
- ETV (1)
- EU-WFD (1)
- EXAFS (1)
- Early Earth (1)
- Ecotoxicity (1)
- Ecotoxicological Testing (1)
- Ecotoxicology testing (1)
- Editorial (1)
- Einzelzellanalyse (1)
- Elastin-specific contrast agent ESMA (1)
- Elastin-specific molecular agent (1)
- Electrochemical Reactor (1)
- Electrochemical energy conversion (1)
- Electrochemical oxidation (1)
- Electrochemical real-time mass spectrometry (1)
- Electrochemistry mass spectrometry (1)
- Electromagnetic (1)
- Electronic Lab Notebook (ELN) (1)
- Electronic nose (1)
- Electrospray (1)
- Elektronenmikroskopie (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Elemental analysis (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Emergency (1)
- Emerging brominated flame retardant (1)
- Emerging contaminants (1)
- Emerging/novel brominated flame retardant (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Energy storage (1)
- Environmental analysis (1)
- Environmental impacts (1)
- Environmental pollutants (1)
- Environmental pollution monitoring (1)
- Equilibrium constant (1)
- Escherichia coli (1)
- Esterification (1)
- Estrogens (1)
- Ethyl glucuronide (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- European Reference Material (1)
- Exhaust (1)
- Experimental design (1)
- Exposure (1)
- Extended X-ray absorption fine structure (1)
- Extractable organic fluorine (1)
- Extraction (1)
- FAIR research data management (1)
- FLAG peptide (1)
- FLIM (1)
- FPLC (1)
- FTIR (1)
- FTIR spectroscopy (1)
- Fast flow GD (1)
- Fast single pulse response (1)
- Fatty acid desaturation (1)
- Fatty acid synthesis (1)
- Fatty acid uptake (1)
- Fatty acids (1)
- Fe nanoparticles metabolism (1)
- Fenton (1)
- Fenton’s reagent (1)
- Fertilizer (1)
- Festphasenextraktion (1)
- Filter crucible (1)
- Finow Canal (1)
- Flow Chemistry (1)
- Flow cytometry (1)
- Flow injection immunoassay (1)
- Fluidics (1)
- Fluorescence lifetime (1)
- Fluorescence sensing (1)
- Fluorination (1)
- Fluorophilic interactions (1)
- Fluxomics (1)
- Folic acid (1)
- Food Analysis (1)
- Food contaminants (1)
- Food fermentation (1)
- Food safety (1)
- Formulation additives (1)
- Fow injection analysis (1)
- Fracture (1)
- Fragmentation activation (1)
- Fundamentals (1)
- Fungicide (1)
- Fusarium (1)
- Fusarium mycotoxin (1)
- GD-MS (1)
- GF-MAS (1)
- GMAW (1)
- Gadofosveset (1)
- Gadolinium-based contrast agent (1)
- Gadolinium-based contrast agents (GBCAs) (1)
- Gadovist (1)
- Gas analysis (1)
- Gated hybrid material (1)
- General Chemistry (1)
- General Medicine (1)
- Genetics (1)
- Geochemistry (1)
- Geochemistry and Petrology (1)
- Geological material (1)
- Geophysics (1)
- Germanium chlorides (1)
- Germanium sulfide (1)
- Gerätekommunikation (1)
- Gilding (1)
- Github (1)
- Glass Support (1)
- Glucose (1)
- Glycosaminoglycan (1)
- Gold (1)
- Gold nanoparticles (1)
- Graphit (1)
- Greek curse tablets (1)
- Group profile (1)
- HERFD-XAS (1)
- HF free Digestion (1)
- HLA (1)
- HPLC-DAD/FLD (1)
- HPLC-ICP-MS (1)
- HPLC-MS (1)
- HPLC–MS (1)
- HR-CS-GFMAS (1)
- HT22 (1)
- HTS (1)
- Harsh environment (1)
- Hay fever (1)
- Hazardous substances (1)
- HeLa (1)
- Heart attack (1)
- Heat flow (1)
- Heavy crude oil (1)
- Heavy metals (1)
- Hepatocellular carcinoma (1)
- HexaHis-Tag (1)
- Hierarchical cluster analysis (1)
- High pH (1)
- High pressure experiments (1)
- High purity (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-fired gypsum mortar (1)
- High-frequency arc discharge (1)
- High-purity elements (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- High-resolution continuum source molecular absorption spectrometry (1)
- High-resolution mass spectrometry (1)
- High-resolution synchrotron XRF (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Histology (1)
- Hormone (1)
- Host–guest systems (1)
- Hot electrons (1)
- Hot-pressing (1)
- Human Plasma (1)
- Human papillomavirus (1)
- Hybridization (1)
- Hybridoma (1)
- Hydrated silicate melts (1)
- Hydrochloric acid (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrogen Storage (1)
- Hydrogen adsorption storage (1)
- Hydrogen reduction (1)
- Hydrolysis products (1)
- Hydrolytic resistance (1)
- Hydrothermal fluid (1)
- Hydroxylation (1)
- Hypothalamus (1)
- IC50 (1)
- ICP MS (1)
- ICP-AES (1)
- ICP-MS/MS (1)
- ICP-OES (1)
- ICP-TOF-MS (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- IDMS (1)
- IMAC purification (1)
- ISO 16000-6 (1)
- ISO REMCO (1)
- Identity (1)
- IgG determination (1)
- IgY (1)
- Iinductively coupled plasma mass spectrometry (1)
- Immunoaffinity extraction (1)
- Immunoassays (1)
- Immunocapture (1)
- Immunofluorescence (1)
- Immunology (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunosensor (1)
- Implant material (1)
- Impurites (1)
- Impurity assessment (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ measurement (1)
- In situ studies (1)
- In vitro (1)
- In vivo imaging (1)
- Indirect Hard Modeling (1)
- Indoor air (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inductively coupled plasma mass spectroscopy (1)
- Industrial and Manufacturing Engineering (1)
- Industrial gypsum (1)
- Industry 4.0, (1)
- Inflammation (1)
- Ink analysis (1)
- Inlet ionization (1)
- Inline NMR Spectroscopy (1)
- Inorganic chemical analysis (1)
- Insecticide (1)
- Instrument Communication (1)
- Instrumental isotope fractionation (1)
- Instrumentation (1)
- Integrated Processes (1)
- Interlaboratory key comparison (1)
- Internal standard (1)
- Ion mobility (1)
- Ion mobility spectrometry (1)
- Ionization (1)
- Ionmobility spectrometry (1)
- Ionophore (1)
- Ionophore antibiotics (1)
- Iposomes (1)
- Iridium oxide (1)
- Iron Complex (1)
- Iron disorders (1)
- Iron nanoparticles (1)
- Iron oxide (1)
- Isotope Dilution (1)
- Isotope Labelling (1)
- Isotope amount ratio (1)
- Isotope delta value (1)
- Isotope fractionation (1)
- Isotope-labeled (1)
- Isotopes (1)
- Isotopic analysis (1)
- Isotopic dilution (1)
- Isotopologue Distribution (1)
- Iterative real-time optimization (1)
- Job plot (1)
- Kidney (1)
- Kilogram (1)
- Kinetics (1)
- Kjeldahl (1)
- Kläranlage (1)
- Knowledge representation (1)
- Konjugate (1)
- L-alanine (1)
- LA-(MC-)ICP-MS (1)
- LA-ICP-SFMS (1)
- LA/ICP-MS Imaging (1)
- LC-UV absorbance (1)
- LC/HRMS (1)
- Lab of the Future (1)
- Lab-on-a-Chip (1)
- Lab-on-a-chip (1)
- Labeling (1)
- Labor der Zukunft (1)
- Laboratory 4.0 (1)
- Lactate (1)
- Lacunary Keggin ion (1)
- Ladder sequencing (1)
- Lapis lazuli (1)
- Lasalocid (1)
- Laser (1)
- Laser Ablation (1)
- Laser Doppler vibrometer (1)
- Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) (1)
- Laser ablation-inductively coupled plasma-mass spectrometry (1)
- Laser beam welding (1)
- Laser induced breakdown Spectrocopy (LIBS) (1)
- Laser induced plasma (1)
- Laser metal deposition (LMD) (1)
- Lateral flow assay (1)
- Lateral flow test (1)
- Lead ions (1)
- Lead isotope composition (1)
- Lead isotopes (1)
- Lebensmittel (1)
- Legacy pollution (1)
- Library (1)
- Ligand design (1)
- Ligands (1)
- Light chain (1)
- Limit of detection (1)
- Lipid metabolism (1)
- Lipids (1)
- Liver X receptor (1)
- Low energy electrons (1)
- Low-energy electrons (1)
- Luminescence lifetime (1)
- Luminol (1)
- Lung cancer (1)
- Lymnaea stagnalis (1)
- Lysergic acid hydrazide (1)
- Lysosome (1)
- MALDI Imaging MS (1)
- MALDI-ToF-MS (1)
- MAS NMR spectroscopy (1)
- MC-TIMS (1)
- MCC (1)
- MICAP-MS (1)
- MOF (1)
- MOSH/MOAH (1)
- MR Angiography (1)
- MR imaging (1)
- MS/MS (1)
- Macrocycles (1)
- Macrophagen (1)
- Magnesium (1)
- Magnesium isotope ratios (1)
- Magnetic nanocatalyst (1)
- Magnetically stabilized (1)
- Maia detector (1)
- Maillard reaction (1)
- Mass contents (1)
- Mass cytometry (1)
- Mass-spectrometry (1)
- Material Science (1)
- Materials science and engineering (1)
- Matrices (1)
- Matrix independent calibration (1)
- Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) (1)
- Matrixeffekte (1)
- Measuremment uncertainty (1)
- Mechanism (1)
- Mechanochemical synthesis (1)
- Medicinal application (1)
- MefHySto (1)
- Melanoidin (1)
- Melanoidine (1)
- Mercury speciation (1)
- Mesoporous materials (1)
- Mesoporous particles (1)
- Mesoporous silica (1)
- Messunsicherheit (1)
- Metabolic Flux (1)
- Metabolism (1)
- Metabolization (1)
- Metal nanoclusters (1)
- Metal nanoparticles (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metalloprotein (1)
- Metal−organic frameworks (1)
- Metformin (1)
- Methylmercury (1)
- Metrology in Chemistry (1)
- Metrology in chemistry (1)
- Micro-Hydrocyclone (1)
- Micro-XRF (1)
- Micro-sublimation (1)
- Microbe interactions (1)
- Microbial proteomics (1)
- Microdialysis (1)
- Microdroplet generator (1)
- Microemulsion (1)
- Microfluidic Chip (1)
- Microfluidic system (1)
- Microfluidics (1)
- Microfluids (1)
- Microparticles (1)
- Microplastic analysis (1)
- Microplastic pathways (1)
- Microplastic-induced effects (1)
- Microplastics analytic (1)
- Microplatic (1)
- Microscopy (1)
- Microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) (1)
- Mikroplastik (1)
- Mikroplastik Massegehalt (1)
- Mineral oil hydrocarobons (1)
- Miniaturization (1)
- Missing wedge (1)
- Mixed ink (1)
- Mixture toxicity (1)
- Mobile analysis (1)
- Mobile analytics (1)
- Model (1)
- Modelling (1)
- Modified mycotoxins (1)
- Modifier adaptation (1)
- Moisture measurements (1)
- Mole (1)
- Molecular Biology (1)
- Molecular analysis (1)
- Molecular dynamics simulations (1)
- Molecular emission (1)
- Molecular imaging (1)
- Molecular imprinted polymers (1)
- Molecular imprinting (1)
- Molecular marker (1)
- Molecular recognition (1)
- Molecular spectra (1)
- Molecular-MRI (1)
- Molecule (1)
- Monensin (1)
- Monitoring (1)
- Monoclonal Antibodies (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monoclonal antibody (1)
- Monolith (1)
- Monolithic column (1)
- Monoterpene (1)
- Moxidectin (1)
- Mud volcanoe fluids (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element analysis (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Multiplexing (1)
- Multivariate Statistics (1)
- Multivariate analyses (1)
- Multivariate analysis (1)
- Mycotoxin Analysis (1)
- Müllverbrennung (1)
- NIR (1)
- NIR Spectroscopy (1)
- NIR emitter (1)
- NIR spectroscopy (1)
- NIR-II (1)
- NIST (1)
- NIST-mAb 8671 (1)
- NMR (1)
- NMR Spectroscopy (1)
- NMR spectroscopy (1)
- Nano-carrier (1)
- Nanocluster (1)
- Nanomaterial (1)
- Nanoparticle characterization (1)
- Nanoparticles with same nominal diameter (1)
- Nanoplatelet (1)
- Naphthalene (Nap) (1)
- Near edge X-ray absorption fine structure spectroscopy (1)
- Near-infrared refectography (1)
- Network (1)
- Neural network (1)
- Nickel chelate (1)
- Nile Red (1)
- Nitration (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Nitrogen plasma (1)
- Non-destructive testing (1)
- Non-metal analysis (1)
- Non-targeted analysis (1)
- Nondestructive testing (1)
- Nondestructive testing techniques (1)
- Nontarget analysis (1)
- Nuclear Magnetic Resonance Spectroscopy (1)
- Nuclear magnetic resonance spectroscopy (1)
- Nuclear receptor (1)
- Nucleocapsid (1)
- OECD (1)
- Oberflächenwasser (1)
- Ochratoxin A (1)
- On-line CE/MC-ICP-MS (1)
- On-site detection (1)
- Online NMR Spectroscopy (1)
- Online biosensor (1)
- Ontology (1)
- Open Science (1)
- Open science (1)
- Optical detection (1)
- Optical emission spectroscopy (1)
- Optical sensor (1)
- Orbitrap (1)
- Ore provenance (1)
- Organic Synthesis (1)
- Organic calibration solution (1)
- Organic contaminants (1)
- Outdoor odor emissions (1)
- Oxidative metabolism (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- P-aminothiophenol (1)
- PAH (1)
- PAHs (1)
- PEG (1)
- PGAA (1)
- PIC technology (1)
- PIXE (1)
- PLS regression (1)
- PXRD (1)
- Papyrus (1)
- Partial Least Squares Regression (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle size distribution (1)
- Pattern recognition receptor (1)
- Pb isotopes (1)
- Peptide (1)
- Peptide library screening (1)
- Peptide losses (1)
- Peptide mass fingerprinting (1)
- Peptides (1)
- Peptides and Proteins (1)
- Per- and Polyfluoroalkyl substances (PFAS) (1)
- Per- and polyfluorinated alkly substances (PFASs) (1)
- Per- and polyfluorinated alkyl substances (PFASs) (1)
- Per- and polyfluoroalkyl substances (PFAS) (1)
- Peristaltic pumps (1)
- Peroxidase (1)
- Ph (1)
- Pharmaceutical (1)
- Pharmaceutical Science (1)
- Pharmazeutika (1)
- Phase field method (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phospholipids (1)
- Phosphonate esters (1)
- Phosphor (1)
- Photocatalysis (1)
- Photochemistry (1)
- Photodynamische Inaktivierung (1)
- Photokatalyse (1)
- Photonic biosensor (1)
- Photooxidation (1)
- Photophysics (1)
- Photosensibilisator (1)
- Photosensitization (1)
- Phthalocyanin (1)
- Physical and theoretical chemistry (1)
- Physical twin (1)
- Phytoliths (1)
- Pigment analyses (1)
- Pilot comparison (1)
- Plant tissue (1)
- Plant-model mismatch (1)
- Plasma induced luminescence (1)
- Plasmaspectrochemistry (1)
- Plastic bottles (1)
- Point of inflection (1)
- Polarised light microscopy (1)
- Polishing (1)
- Pollen extract (1)
- Pollen grains (1)
- Pollution (1)
- Polyclonal Antibodies (1)
- Polycyclic aromatic hydrocarbons (1)
- Polyethylenimine (1)
- Polymer blends (1)
- Polymer membrane (1)
- Polymer particle (1)
- Polymers (1)
- Polymorphs (1)
- Polyoxometalates (1)
- Polyurethanes (1)
- Pore fluids (1)
- Porphyrin (1)
- Portland cement (1)
- Portland clinker (1)
- Priam's treasure (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Priority effect (1)
- Probenvorbereitung (1)
- Process Industry (1)
- Process control (1)
- Process industry (1)
- Process intelligence (1)
- Production (1)
- Proficiency testing (1)
- Programmed cell death (1)
- Prostate cancer (1)
- Protein (1)
- Protein A (1)
- Protein Purification (1)
- Protein analysis (1)
- Protein content (1)
- Protein hydrolysis (1)
- Protein imaging (1)
- Protein nitration (1)
- Protein oligomerization (1)
- Protein quantification (1)
- Protein test (1)
- Provenance (1)
- Provenance studies (1)
- Provenancing (1)
- Pt-based drugs (1)
- PtNP (1)
- Pulsed-GD-SFMS (1)
- Pulverization (1)
- Pyrethroid (1)
- Pyrolysis (1)
- QC (1)
- Quality Assurance (1)
- Quality Control (1)
- Qualitätskontrolle (1)
- Quantitative bioimaging (1)
- Quantitative determination (1)
- Quantum dots (1)
- Quantum rod (1)
- Quick-XAS (1)
- RBD (1)
- RSSI Received Signal Strength Indicator (1)
- RXES (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Rat/human liver microsomes (1)
- Rational design (1)
- Reaction Monitoring (1)
- Reactor control (1)
- Real-time imaging (1)
- Real-time quality control (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Recovery (1)
- Reference (1)
- Reference Material (1)
- Reference Materials (1)
- Reference measurements (1)
- Referenzmaterial (1)
- Refractory alloys (1)
- Regeneration (1)
- Region of interest (1)
- Remediation (1)
- Renal disease (1)
- Renewable Energy (1)
- Research Data Infrastructure (1)
- Research Data Management (1)
- Resonance wavelength shift (1)
- Reversible covalent hydrazine chemistry (RCHC) (1)
- Revision of the SI (1)
- Rhizopus (1)
- Rhizopus and Aspergillus oryzae (1)
- Rhodamine (1)
- Ring resonator (1)
- River (1)
- River water sulfate (1)
- Robustness (1)
- Round robin exercise (1)
- Round robin test (1)
- SBA-16 (1)
- SC-ICP-MS (1)
- SDHI-fungicide (1)
- SI Traceability (1)
- SI-traceability (1)
- SIDA-LC-MS/MS (1)
- SOM-SM (1)
- SPM (1)
- SPR (1)
- Safety (1)
- Salinomycin (1)
- Sample preparation (1)
- Sample treatment (1)
- Sample-sample bracketing (1)
- Sampling (1)
- Sampling techniques (1)
- Sapphire (1)
- Scale anchor (1)
- Screening method (1)
- Seawater (1)
- Secondary alcohols (1)
- Sediment (1)
- Sedimentation box (SB) (1)
- Selenium (1)
- Self-assembly (1)
- Self-healing (1)
- Semantic data integration (1)
- Semantic interoperability (1)
- Semiconductor nanocrystals (1)
- Semiconductor quantum dot (1)
- Sensing (1)
- Sensor network (1)
- Sensors (1)
- Sequence coverage (1)
- Sequence dependence (1)
- Sequencing (1)
- Sers (1)
- Serum (1)
- Sewage sludge (1)
- Sewage treatment plant (1)
- Signal enhancement (1)
- Silanization (1)
- Silbernanopartikel (1)
- Silica diagenesis (1)
- Silicon (1)
- Silicon chlorides (1)
- Silicon isotopes (1)
- Silver nanoparticles (1)
- Single Cell (1)
- Single cell (1)
- Single cell analysis (1)
- Single cell-ICP-MS (1)
- Single-cell analysis (1)
- Sintered Material (1)
- Sintering (1)
- Slags (1)
- Smart Sensors (1)
- Smart sensors (1)
- Smart test laboratories (1)
- Smartphone readout device (1)
- Society of hair testing (1)
- Soda-lime glass (1)
- Soft-templated mesoporous films (1)
- Software (1)
- Soil available boron (1)
- Soils (1)
- Solid phase extraction (SPE) (1)
- Solid state NMR (1)
- Solid-liquid extraction (1)
- Solid-phase extraction (1)
- Solvent-free (1)
- Solvents (1)
- Sonochemical synthesis (1)
- Sorghum (1)
- Spark plasma sintering (1)
- Special issue, young analytical scientists (1)
- Speciation analysis (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrometer (1)
- Spectrometry (1)
- Speroid (1)
- Spheroid (1)
- Spike protein (1)
- Spinel (1)
- Sputtering (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stability (1)
- Stable isotopes (1)
- Stakeholders (1)
- Standards (1)
- Static Mixing (1)
- Statistical analysis (1)
- Steel (1)
- Strain identification (1)
- Strontium isotope (1)
- Structural Biology (1)
- Structural Health Monitoring (1)
- Sulfur isotopes (1)
- Sulphur isotope (1)
- Sum Parameter (1)
- Sum Parameter Method (1)
- Sum parameter (1)
- Sum parameter method (1)
- Supramolecular chemistry (1)
- Surface chemistry (1)
- Surface coating (1)
- Surface modification (1)
- Surface waters (1)
- Surface-plasmon resonance (1)
- Suspended particulate matter (SPM) (1)
- Sustainability and the Environment (1)
- Sustainable Food Safety (1)
- Sustainable Production (1)
- Suzuki coupling (1)
- Synchrotron FTIR (1)
- Synthetic peptides (1)
- TD-GC-MS (1)
- TED-GC-MS (1)
- TGA-MS (1)
- TXRF-XAS (1)
- Tag (1)
- Tandem MS (1)
- Tantalum oxyfluorides (1)
- Target (1)
- Tattoo inks (1)
- Tau (1)
- Terephthalic acid (1)
- Terrorism (1)
- Tesserae (1)
- Test midpoint (1)
- Test strips (1)
- Tetramethylammonium hydroxide (1)
- The MOUSE (1)
- Therapeutic Antibodies (1)
- Therapeutic Drug Monitoring (1)
- Thermal analysis (1)
- Thermal conductivity device (1)
- Thermal decomposition (1)
- Thermal degradation (1)
- Thermal desorption (1)
- Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring (1)
- Thermal extraction-desorption gas chromatography mass spectrometry (1)
- Thermal model (1)
- Thermo-desorption (1)
- Thermoplastic (1)
- Thin tissue sections (1)
- Time of flight (1)
- Tire Wear (1)
- Tire particles (1)
- Tissue (1)
- Tissue soldering (1)
- Titanium hydride (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Total cyanide (1)
- Total element content (1)
- Total element determination (1)
- Toxic metals (1)
- Toxicity (1)
- Toxicity testing (1)
- Toxikologie (1)
- Toys (1)
- Trace Analysis (1)
- Trace humdity measurement (1)
- Transesterification (1)
- Transferrin (1)
- Transformationsprodukte (1)
- Transient signal (1)
- Trojan silver artefacts (1)
- Truffle (1)
- Truffle Aroma (1)
- Tryptic digest (1)
- Tryptophan (1)
- Tuber melanosporum (1)
- Two-dimensional off-line coupling (1)
- Two-phase system (1)
- Type-I pyrethroids (1)
- UV Bestrahlung (1)
- UV irradiation (1)
- Ultrasensitive (1)
- Ultrasound (1)
- Urban (1)
- Urine (1)
- VO (1)
- Vacuum ionization (1)
- Vacuum ultraviolet (VUV) light (1)
- Validation trial (1)
- Validierung (1)
- Vanadium (1)
- Vanadium redox flow battery (1)
- Vegetable edible oil (1)
- Veterinary drugs (1)
- Viscosity (1)
- Visualization (1)
- Volatile marker (1)
- Volatile organic compounds; (1)
- Volatiles (1)
- WWTP (1)
- Wasser (1)
- Water analysis (1)
- Water stable isotope analysis (1)
- Whole water samples (1)
- Workflow (1)
- X-Ray Fluorescence (1)
- X-ray absorption spectroscopy (1)
- X-ray fluorescence spectroscopy (1)
- X-ray fuorescence (1)
- XANES spectroscopy (1)
- XAS (1)
- XRCD method (1)
- Xerogel (1)
- Yerba mate tea (1)
- ZIF-8 (1)
- Zearalenone (1)
- Zearalenone sulfate (1)
- Zebrafisch (1)
- Zenodo (1)
- Zinc (1)
- Zinc analysis (1)
- Zirconium (1)
- Zn (1)
- Zyklisierung (1)
- a-zearalenol (1)
- aRTist (1)
- battery aging mechanism (1)
- bell pepper (1)
- boron (1)
- current collector corrosion (1)
- delta value (1)
- depth profiles (1)
- ion optics (1)
- isotope fractionation (1)
- lank characterization (1)
- magnetic nanocatalysts (1)
- measurement uncertainty (1)
- metabolism (1)
- microstructural changes (1)
- openBIS (1)
- p-Aminothiophenol (1)
- p-Nitrothiophenol (1)
- pH sensor (1)
- pL-droplets (1)
- silicon (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- Ägyptisches Museum Berlin (1)
- β-lactam (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (288)
- 1.1 Anorganische Spurenanalytik (106)
- 6 Materialchemie (71)
- 1.7 Organische Spuren- und Lebensmittelanalytik (69)
- 6.3 Strukturanalytik (51)
- 1.8 Umweltanalytik (40)
- 1.4 Prozessanalytik (27)
- 1.6 Anorganische Referenzmaterialien (27)
- 1.5 Proteinanalytik (26)
- P Präsident (22)
Paper des Monats
- ja (7)
Fast and accurate determination of the protein content of a sample is an important and non-trivial task of many biochemical, biomedical, food chemical, pharmaceutical, and environmental research activities. Different methods of total protein determination are used for a wide range of proteins with highly variable properties in complex matrices. These methods usually work reasonably well for proteins under controlled conditions, but the results for non-standard and complex samples are often questionable. Here, we compare new and well-established methods, including traditional amino acid analysis (AAA), aromatic amino acid analysis (AAAA) based on the amino acids phenylalanine and tyrosine, reversed-phase liquid chromatography of intact proteins with UV absorbance measurements at 220 and 280 nm (LC-220, LC-280), and colorimetric assays like Coomassie Blue G-250 dye-binding assay (Bradford) and bicinchoninic acid (BCA) assay. We investigated different samples, including proteins with challenging properties, chemical modifications, mixtures, and complex matrices like air particulate matter and pollen extracts. All methods yielded accurate and precise results for the protein and matrix used for calibration. AAA, AAAA with fluorescence detection, and the LC-220 method yielded robust results even under more challenging conditions (variable analytes and matrices). These methods turned out to be well-suited for reliable determination of the protein content in a wide range of samples, such as air particulate matter and pollen.
The study, dedicated to Beautiful Pietàs conserved in South Tyrol (Northern Italy), aims to establish, for the first time, a connection between Austroalpine raw materials and the high-fired gypsum mortars constituting the Gothic figure groups in question. The origin and chronology of this stylistically and qualitatively differing ensemble have been subject of art historical debate for nearly a century. The discourse is dominated by three main hypotheses: itinerary of an Austrian artist versus itinerary of the work of art created in an artist’s workshop in Austria versus itinerary of the stylistic vocabulary via graphical or three-dimensional models. The comparison of the δ34S values and the 87Sr/86Sr ratios of the gypsum mortars and Austroalpine sulphate deposits (in a compilation of own reference samples and literature data) points to the exploitation of sediments in the Salzkammergut and possibly also in the evaporite district of the Eastern Calcareous Alps, thus evidencing the import of the sculptures and not the activities of local South Tyrolean or itinerant artists. Two geochronological units are distinguishable: The Pietà in the Church St. Martin in Göflan can be assigned to Upper Permian raw material, whereas the metrologically consistent sculptures in the Church of Our Lady of the Benedictine Abbey Marienberg and in the Chapel St. Ann in Mölten correlate with deposits of the Early Triassic (or the Lower-Middle Triassic transition). The medieval gypsum mortars also differ in their mineralogical characteristics, i.e. in their geologically related minor components, as in the first case, characterised by a significant proportion of primary anhydrite, natural carbonate impurities mainly consist of calcite (partly converted to lime-lump-like aggregates), whereas in the second group dolomite (or rather its hydration products after pyrometamorphic decomposition) predominates, accompanied by celestine, quartz and potassium feldspar. The Pietà in the Cathedral Maria Himmelfahrt in Bozen turned out to be made of Breitenbrunn calcareous sandstone (Leitha Mountains, Burgenland, Austria), which is why the sample is not considered in the geochemical analysis.
Quantitative proteomics is a growing research area and one of the most important tools in the life sciences. Well-characterized and quantified protein standards are needed to achieve accurate and reliable results. However, only a limited number of sufficiently characterized protein standards are currently available. To fill this gap, a method for traceable protein quantification using sulfur isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) was developed in this study.
Gel filtration and membrane filtration were tested for the separation of non-protein-bound sulfur in the protein solution.
Membrane filtration demonstrated a better performance due to the lower workload and the very low sulfur blanks of 11 ng, making it well suited for high-purity proteins such as NIST SRM 927, a bovine serum albumin (BSA). The method development was accomplished with NIST SRM 927e and a commercial avidin. The quantified mass fraction of NIST SRM 927e agreed very well with the certified value and showed similar uncertainties (3.6%) as established methods while requiring less sample preparation and no species-specific standards. Finally, the developed procedure was applied to the tau protein, which is a biomarker for a group of neurodegenerative diseases denoted “tauopathies” including, e.g., Alzheimer’s disease and frontotemporal dementia. For the absolute quantification of tau in the brain of transgenic mice overexpressing human tau, a well-defined calibration standard was needed. Therefore, a pure tau solution was quantified, yielding a protein mass fraction of (0.328 ± 0.036) g/kg, which was confirmed by amino acid analysis.
The entire process involving the determination of Cl by molecular emission detection in Laser-Induced Breakdown Spectroscopy (LIBS) is thoroughly studied in this paper. This critical evaluation considers how spectra are normalized, how interferences from other molecular species signals are removed, and how signal integration is applied. Moreover, a data treatment protocol is proposed to achieve reliable and accurate Cl determination from the CaCl molecular spectral signal, not requiring the use of more complex numerical approaches. Calcium chloride dihydrate (CaCl2⋅2H2O) and high purity anhydrite samples (CaSO4) are used to optimize the acquisition conditions and data treatment of CaCl emission signal. Using the developed protocol, calibration curves for Cl, covering the concentration range from 0 μg/g to 60,000 μg/g of Cl, are successfully achieved. Finally, the suitability of the proposed methodology for Cl determination is successfully applied in industrial gypsum waste samples, where the results obtained by LIBS are validated using high-resolution molecular absorption spectroscopy (HR-CS-MAS) and potentiometric titration.
Here, we describe an optimized fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) in soils utilizing high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR–CS–GFMAS). To omit the bias of the solid phase extraction (SPE) step commonly used during the analysis of extractable organically bound fluorine (EOF) we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol without any additional SPE. Four extraction steps were representative to determine a high proportion of the EOF (>80% of eight extractions). Comparison of the optimized method with and without an additional SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. Differences of up to 94% were observed which were not explainable by coextracted inorganic fluoride. Therefore, not only a more accurate but also a more economic as well as ecologic method (bypassing of unnecessary SPE) was developed. The procedural limit of quantification (LOQ) of the developed method was 10.30 μg/kg which was sufficient for quantifying EOF concentrations in all tested samples. For future PFAS monitoring and potential regulative decisions the herein presented optimized extraction method can offer a valuable contribution.
n situ monitoring of mechanochemical reactions between dicyandiamide (DCD) and CuX2 salts (X = Cl−, NO3−), for the preparation of compounds of agrochemical interest, showed the appearance of a number of phases. It is demonstrated that milling conditions, such as the amount of water added in wet grinding and/or the milling frequency, may affect the course of the mechanochemical reactions, and drive the reaction towards the formation of different products. It has been possible to discover by in situ monitored experiments two novel crystalline forms, namely the neutral complexes [Cu(DCD)2(OH2)2(NO3)2] (2) and [Cu(DCD)2(OH2)Cl2]·H2O (4), in addition to the previously known molecular salt [Cu(DCD)2(OH2)2][NO3]2·2H2O (1, DIVWAG) and neutral complex [Cu(DCD)2(OH2)Cl2] (3, AQCYCU), for which no synthesis conditions were available. Compounds 2 and 4 were fully characterized via a combination of solid-state techniques, including X-ray diffraction, Raman spectroscopy and TGA.
Imaging Keratan Sulfate in Ocular Tissue Sections by Immunofluorescence Microscopy and LA-ICP-MS
(2022)
Carbohydrate-specific antibodies can serve as valuable tools to monitor alterations in the extracellular matrix resulting from pathologies. Here, the keratan sulfate-specific monoclonal antibody MZ15 was characterized in more detail by immunofluorescence microscopy as well as laser ablation ICP-MS using tissue cryosections and paraffin-embedded samples. Pretreatment with keratanase II prevented staining of samples and therefore demonstrated efficient enzymatic keratan sulfate degradation. Random fluorescent labeling and site-directed introduction of a metal cage into MZ15 were successful and allowed for a highly sensitive detection of the keratan sulfate landscape in the corneal stroma from rats and human tissue.
Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed.
TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance.
The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation.
With the increasing production of renewable energy and concomitant depletion of fossil resources, the demand for efficient water splitting electrocatalysts continues to grow. Iridium (Ir) and iridium oxides (IrOₓ) are currently the most promising candidates for an efficient oxygen evolution reaction (OER) in acidic medium, which remains the bottleneck in water electrolysis. Yet, the extremely high costs for Ir hamper a widespread production of hydrogen (H₂) on an industrial scale. Herein, the authors report a concept for the synthesis of electrode coatings with template-controlled mesoporosity surface-modified with highly active Ir species. The improved utilization of noble metal species relies on the synthesis of soft-templated metal oxide supports and a subsequent shape-conformal deposition of Ir species via atomic layer deposition (ALD) at two different reaction temperatures. The study reveals that a minimum Ir content in the mesoporous titania-based support is mandatory to provide a sufficient electrical bulk conductivity. After ALD, a significantly enhanced OER activity results in dependency of the ALD cycle number and temperature. The most active developed electrocatalyst film achieves an outstanding mass-specific activity of 2622 mA mg(Ir)⁻¹ at 1.60 V(RHE) in a rotating-disc electrode (RDE) setup at 25 °C using 0.5 m H₂SO₄ as a supporting electrolyte.
The drug salinomycin (SAL) is a polyether antibiotic and used in veterinary Medicine as coccidiostat and growth promoter. Recently, SAL was suggested as a potential anticancer drug.
However, transformation products (TPs) resulting from metabolic and environmental degradation of SAL are incompletely known and structural information is missing. In this study, we therefore systematically investigated the formation and identification of SAL derived TPs using electrochemistry (EC) in an electrochemical reactor and rat and human liver microsome incubation (RLM and HLM) as TP generating methods. Liquid chromatography (LC) coupled to high-resolution mass spectrometry (HRMS) was applied to determine accurate masses in a suspected target analysis to identify TPs and to deduce occurring modification reactions of derived TPs. A total of 14 new, structurally different TPs were found (two EC-TPs, five RLM-TPs, and 11 HLM-TPs). The main modification reactions are decarbonylation for EC-TPs and oxidation (hydroxylation) for RLM/HLM-TPs. Of particular interest are potassium-based TPs identified after liver microsome incubation because these might have been overlooked or declared as oxidated sodium adducts in previous, non-HRMS-based studies due to the small mass difference between K and O + Na of 21 mDa. The MS fragmentation pattern of TPs was used to predict the position of identified modifications in the SAL molecule. The obtained knowledge regarding transformation reactions and novel TPs of SAL will contribute to elucidate SAL-metabolites with regards to structural prediction.
Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.
The 87Sr/86Sr isotope ratio can, in principle, be used for provenancing of cement. However, while commercial cements consist of multiple components, no detailed investigation into their individual 87Sr/86Sr isotope ratios or their influence on the integral 87Sr/86Sr isotope ratio of the resulting cement was conducted previously. Therefore, the present study aimed at determining and comparing the conventional 87Sr/86Sr isotope ratios of a diverse set of Portland cements and their corresponding Portland clinkers, the major component of these cements. Two approaches to remove the additives from the cements, i.e. to measure the conventional 87Sr/86Sr isotopic fingerprint of the clinker only, were tested, namely, treatment with a potassium hydroxide/sucrose solution and sieving on a 11-µm sieve. Dissolution in concentrated hydrochloric acid/nitric acid and in diluted nitric acid was employed to determine the 87Sr/86Sr isotope ratios of the cements and the individual clinkers. The aim was to find the most appropriate sample preparation procedure for cement provenancing, and the selection was realised by comparing the 87Sr/86Sr isotope ratios of differently treated cements with those of the corresponding clinkers. None of the methods to separate the clinkers from the cements proved to be satisfactory. However, it was found that the 87Sr/86Sr isotope ratios of clinker and cement generally corresponded, meaning that the latter can be used as a proxy for the clinker 87Sr/86Sr isotope ratio. Finally, the concentrated hydrochloric acid/nitric acid dissolution method was found to be the most suitable sample preparation method for the cements; it is thus recommended for 87Sr/86Sr isotope analyses for cement provenancing.
The CCQM-K148.a comparison was coordinated by the BIPM on behalf of the CCQM Organic Analysis Working Group for NMIs and DIs which provide measurement services in organic analysis under the CIPM MRA. It was undertaken as a "Track A" comparison within the OAWG strategic plan. CCQM-K148.a demonstrates capabilities for assigning the mass fraction content of a solid organic compound having moderate molecular complexity, where the compound has a molar mass in the range (75 - 500) g/mol and is non-polar (pKow < −2), when present as the primary organic component in a neat organic solid and where the mass fraction content of the primary component in the material is in excess of 950 mg/g.
Participants were required to report the mass fraction of Bisphenol A present in one supplied unit of the comparison material. Participants using a mass balance method for the assignment were also required to report their assignments of the impurity components present in the material. Methods used by the seventeen participating NMIs or DIs were predominantly based on either stand-alone mass balance (summation of impurities) or qNMR approaches, or the combination of data obtained using both methods. The results obtained using thermal methods based on freezing-point depression methods were also reported by a limited number of participants. There was excellent agreement between assignments obtained using all three approaches to assign the BPA content.
The assignment of the values for the mass fraction content of BPA consistent with the KCRV was achieved by most of the comparison participants with an associated relative standard uncertainty in the assigned value in the range (0.1 - 0.5)%.
The vanadium redox flow battery (VRFB) is currently a potential candidate for stationary energy storage. A major challenge is the unintended vanadium transport through the separator, which results in a fade of capacity. To overcome this issue, it is necessary to understand the transport processes in the membrane on a more fundamental level. In this work, the vanadium species distribution in Nafion™ 117 after cyclization was investigated. Two membranes, one from a charged VRFB and another from a discharged VRFB, were analyzed using ultraviolet–visible spectroscopy (UV/VIS) and X-ray absorption near edge structure spectroscopy (XANES). Little difference between the two membranes was recognizable according to the UV/VIS results. In comparison, the XANES results showed that the membrane from the charged VRFB contains more V3+ than VO2+, whereas for the discharged case, more VO2+ is present in the membrane.
Directing nanoparticles to the nucleus by attachment of nuclear localization sequences (NLS) is an aim in many applications. Gold nanoparticles modified with two different NLS were studied while crossing barriers of intact cells, including uptake, endosomal escape, and nuclear translocation. By imaging of the nanoparticles and by characterization of their molecular interactions with surface-enhanced Raman scattering (SERS), it is shown that nuclear translocation strongly depends on the particular incubation conditions. After an 1 h of incubation followed by a 24 h chase time, 14 nm gold particles carrying an adenoviral NLS are localized in endosomes, in the cytoplasm, and in the nucleus of fibroblast cells. In contrast, the cells display no nanoparticles in the cytoplasm or nucleus when continuously incubated with the nanoparticles for 24 h. The ultrastructural and spectroscopic data indicate different processing of NLS-functionalized particles in endosomes compared to unmodified particles. NLS functionalized nanoparticles form larger intraendosomal aggregates than unmodified gold nanoparticles. SERS spectra of cells with NLS-functionalized gold nanoparticles contain bands assigned to DNA and were clearly different from those with unmodified gold nanoparticles. The different processing in the presence of an NLS is influenced by a continuous exposure of the cells to nanoparticles and an ongoing nanoparticle uptake. This is supported by mass-spectrometry-based quantification that indicates enhanced uptake of NLS-functionalized nanoparticles compared to unmodified particles under the same conditions. The results contribute to the optimization of nanoparticle analysis in cells in a variety of applications, e.g., in theranostics, biotechnology, and bioanalytics.
The ubiquitous Fusarium genus is responsible for the spoilage of vast amounts of cereals and fruits.
Besides the economic damage, the danger to human and animal health by the concomitant exposure to mycotoxins represents a serious problem. A large number of Fusarium species produce a variety of different mycotoxins of which the class of trichothecenes are of particular importance due to their toxicity.
Being identified as the common volatile precursor during the biosynthesis of trichothecenes, (−)-trichodiene (TD) is considered to be a biomarker for the respective mycotoxin content in food samples. We postulated that the development of a non-invasive, on-site GC-IMS method for the quantification of (−)-trichodiene supplemented with a stationary SIDA headspace GC-MS reference method would allow circumventing the laborious and expensive analyses of individual trichothecenes in large cereal samples.
In this work we present the syntheses of the required native calibration standard and an isotope labeled (TD-D3) internal standard.
Abstract Alternariol (AOH) and alternariol-9-monomethyl ether (AME) are two secondary metabolites of Alternaria fungi which can be found in various foodstuff like tomatoes, nuts, and grains. Due to their toxicity and potential mutagenic activity the need for the development of high-throughput methods for the supervision of AOH- and AME-levels is of increasing interest. As the availability of both native and labeled AOH and AME analytical standards is very limited we herein wish to present a novel concise approach towards their synthesis employing a ruthenium-catalyzed ortho-arylation as the key step. Finally, we demonstrate their suitability as internal standards in stable-isotope dilution assay (SIDA)-HPLC-MS/MS analysis commonly used for the quantification of the natural products in food and feed.
Polycyclic aromatic hydrocarbons (PAHs) are a large group of priority organic pollutants, which contaminate environmental compartments, food, and consumer products as well. Due to their frequent occurrence associated with elevated Levels of PAHs, plastic and rubber parts of consumer products and toys are particular sources of exposure. Although European maximum levels exist for eight carcinogenic PAHs in consumer products and toys according to REACH Regulation (EC) No. 1907/2006, certified reference materials (CRM) are still not available. To overcome this lack, the first CRM for the determination of PAHs in rubber toys (BAM-B001) was developed according to the requirements of ISO Guide 35. The whole process of CRM development including preparation, homogeneity and stability studies, and value assignment is presented.
The assignment of the certified mass fractions was based upon in-house study at BAM using stable isotope Dilution analysis (SIDA) gas chromatography mass spectrometry (GC–MS). The obtained values were confirmed by the results of two interlaboratory comparison (ILC) studies with more than 50 expert laboratories from Germany and China. The mass fractions of 14 PAHs including all REACH and GS mark regulated compounds were certified ranging between 0.2 and 15.4 mg/
kg accompanied by expanded uncertainties (coverage factor k = 2). In addition, informative values were determined for 4 PAHs, mainly due to higher uncertainties and/or lack of ILC data for confirmation. BAM-B001 is intended for analytical quality control particularly based on the AfPS GS 2019:01 PAK method and contributes to improve the chemical safety of consumer products including toys.
Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are valuable analytical and quality control methods for most industrial chemical processes as they provide information on the concentrations of individual compounds and by-products. These processes are traditionally carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been realized to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra, to train an ANN with better prediction performance and speed than state-of-the-art analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control.
Given the central role of fatty acids in cancer pathophysiology, the exploitation of fatty acid metabolism as a potential antineoplastic therapy has gained much attention. Several natural and synthetic compounds targeting fatty acid metabolism were hitherto identified, and their effectiveness against cancer cell proliferation and survival was determined. This review will discuss the most clinically viable inhibitors or drugs targeting various proteins or enzymes mapped on nine interconnected fatty acid metabolism-related processes. We will discuss the general significance of each of these processes and the effects of their inhibition on cancer cell progression. Moreover, their mechanisms of action, limitations, and future perspectives will be assessed.
Stir bar sorptive extraction (SBSE) was compared with standardized pump sampling regarding the prospects to assess airborne levels of polycyclic aromatic hydrocarbons (PAHs) in indoor environments. A historic railway water tower, which will be preserved as a technical monument for museum purposes, was sampled with both approaches because the built-in insulationmaterial was suspected to release PAHs to the indoor air. The 16 PAHs on the US EPA list were quantified using gas chromatography with mass spectrometric detection in filters from pump sampling after solvent extraction and on SBSE devices after thermal desorption. SBSEwas seen to sample detectable PAHmasseswith excellent repeatability and a congener pattern largely similar to that observed with pump sampling. Congener patterns were however significantly different from that in the PAH source because release from the insulation material is largely triggered by the respective congener vapor pressures. Absolute masses in the ng range sampled by SBSE corresponded to airborne concentrations in the ng L−1 range determined by pump sampling. Principle differences between SBSE and pump sampling as well as prospects of SBSE as cost-effective and versatile complement of pump sampling are discussed.
This paper describes Food-MetNet, a coordinated preparatory initiative to establish the European Metrology Network on Food Safety (EMN-FS). Food-MetNet aims to establish a long-term ongoing dialogue between the metrology community and relevant stakeholders, in particular, European Union Reference Laboratories (EURLs), National Reference Laboratories (NRLs) and the Joint Research Centre (JRC). This dialogue is meant to support the collection of needs from stakeholders, the take-up of metrological research output and the development of the roadmaps needed to navigate future research.
Cardiolipin (CL) is a major cardiac mitochondrial phospholipid maintaining regular mitochondrial morphology and function in cardiomyocytes. Cardiac CL production includes ist biosynthesis and a CL-remodeling process. Here we studied the impact of CL-biosynthesis and the enzyme Cardiolipin Synthase (CLS) on cardiac function.
CLS and cardiac CL-species were significantly downregulated in cardiomyocytes following catecholamine-induced cardiac damage in mice, accompanied by increased oxygen consumption rates, signs of oxidative stress and mitochondrial uncoupling. RNAi-mediated cardiomyocyte-specific knockdown of CLS in Drosophila melanogaster resulted in marked cardiac dilatation, severe impairment of systolic performance and slower diastolic filling velocity assessed by fluorescence-based heart imaging. Finally, we showed that CL72:8 is significantly decreased in cardiac samples from patients with heart failure with reduced ejection fraction (HFrEF). In summary, we identified CLS as a regulator of cardiac function. Considering the cardiac depletion of CL-species in HFrEF, pharmacological targeting of CLS may be a promising therapeutic approach.zeige mehrzeige weniger
Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration.
Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet Setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet Generator (μDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of μDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running.
Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle.
While mode I (counting) and mode III (μDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic Standard solutions only. It is independent of NP reference materials. The μDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.
High-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GF-MAS) was employed for determining adsorbable organic chlorine (AOCl) in water. Organic chlorine was indirectly quantified by monitoring the molecular absorption of the transient aluminum monochloride molecule (AlCl) around a wavelength of 261.42 nm in a graphite furnace. An aluminum solution was used as the molecularforming modifier. A zirconium coated graphite furnace, as well as Sr and Ag solutions were applied as modifiers for a maximal enhancement of the absorption signal. The pyrolysis and vaporization temperatures were 600 °C and 2300 °C, respectively. Non-spectral interferences were observed with F, Br, and I at concentrations higher than 6 mg L-1, 50 mg L-1, and 100 mg L-1, respectively. Calibration curves with NaCl, 4-chlorophenol, and trichlorophenol present the same slope and dynamic range, which indicates the chlorine atom specificity of the method. This method was evaluated and validated using synthetic water samples, following the current standard DIN EN ISO 9562:2004 for the determination of the sum parameter adsorbable organic halides (AOX) for water quality. These samples contain 4-chlorophenol as the chlorinated organic standard in an inorganic chloride matrix. Prior to analysis, organic chlorine was extracted from the inorganic matrix via solid-phase extraction with a recovery rate >95%. There were no statistically significant differences observed between measured and known values and for a t-test a confidence level of 95% was achieved. The limits of detection and characteristic mass were found to be 48 and 22 pg, respectively. The calibration curve was linear in the range 0.1–2.5 ng with a correlation coefficient R2 = 0.9986.
The quantification of the sulphur mass fraction in pure copper and copper alloys by GDMS and LA-ICP-MS revealed a lack of traceability mainly due to a lack of suitable certified reference materials for calibrating the instruments. Within this study GDMS and LA-ICP-MS were applied as routine analytical tools to quantify sulphur in copper samples by applying reference materials as calibrators, which were characterized for their sulphur mass fraction by IDMS beforehand. Different external calibration strategies were applied including a matrix cross type calibration. Both techniques with all calibration strategies were validated by using certified reference materials (others than those used for calibration) and good agreement with the reference values was achieved except for the matrix cross type calibration, for which the agreement was slightly worse. All measurement results were accompanied by an uncertainty statement. For GDMS, the relative expanded (k = 2) measurement uncertainty ranged from 3% to 7%, while for LA-ICP-MS it ranged from 11% to 33% when applying matrix-matched calibration in the sulphur mass fraction range between 25 mg kg-1 and 1300 mg kg-1. For cross-type calibration the relative expanded (k = 2) measurement uncertainty need to be increased to at least 12% for GDMS and to at least 54% for LA-ICP-MS to yield metrological compatibility with the reference values. The so obtained measurement results are traceable to the international system of units (SI) via IDMS reference values, which is clearly illustrated by the unbroken chain of calibrations in the metrological traceability scheme.
Annexin A5 (anxA5) is a marker for apoptosis, but has also therapeutic potential in cardiovascular diseases, cancer, and, due to apoptotic mimicry, against dangerous viruses, which is limited by the short blood circulation. An 864-amino-acid XTEN polypeptide was fused to anxA5. XTEN864-anxA5 was expressed in Escherichia coli and purified using XTEN as tag.
XTEN864-anxA5 was coupled with DTPA and indium-111. After intravenous or subcutaneous injection of 111In-XTEN864-anxA5, mouse blood samples were collected for blood half-life determination and organ samples for biodistribution using a gamma counter. XTEN864-anxA5 was labeled with 6S-IDCC to confirm binding to apoptotic cells using flow cytometry.
To demonstrate targeting of atherosclerotic plaques, XTEN864-anxA5 was labeled with MeCAT(Ho) and administered intravenously to atherosclerotic ApoE−/−mice. MeCAT(Ho)-XTEN864-anxA5 was detected together with MeCAT(Tm)-MAC-2 macrophage antibodies by imaging mass cytometry (CyTOF) of aortic root sections. The ability of anxA5 to bind apoptotic cells was not affected by XTEN864. The blood half-life of XTEN864-anxA5 was 13 h in mice after IV injection, markedly longer than the 7-min half-life of anxA5. 96 h after injection, highest amounts of XTEN864-anxA5 were found in liver, spleen, and kidney. XTEN864-anxA5 was found to target the adventitia adjacent to atherosclerotic plaques. XTEN864-anxA5 is a long-circulating fusion protein that can be efficiently produced in E. coli and potentially circulates in humans for several days, making it a promising therapeutic drug.
With the aim of identifying the origin and the manufacturer of a cement, a reliable procedure that provides unambiguous results is needed. Such procedure could resolve practical issues in damage research, liability issues and forensic investigations. A substantial number of attempts for fingerprinting of building materials, including cement, has already been carried out during the last decades. Most of them were based on concentration analysis of the main elements/components. This review provides an overview of provenance studies of cement and the main approaches commonly used. Provenance studies of cement via isotope techniques are also presented and discussed as representatives of the state-of-the-art in the field. Due to the characteristic properties and the occurrence of carefully selected isotope ratios, unique fingerprints of different kinds of materials can be provided by these methods. This property has largely been explored in various scientific fields such as geo- and cosmochemistry, food forensics, archaeology, geochronology, biomedical studies, and climate change processes. However, the potential of isotope techniques in cement and concrete research for provenance studies has barely been investigated.
Therefore, the review outlines a suitable approach using isotope ratios, which could lead to reliable provenancing of cementitious materials in the future.
MACC1 is a prognostic and predictive metastasis biomarker for more than 20 solid Cancer entities. However, its role in cancer metabolism is not sufficiently explored. Here, we report on how MACC1 impacts the use of glucose, glutamine, lactate, pyruvate and fatty acids and show the comprehensive analysis of MACC1-driven metabolic networks. We analyzed concentrationdependent changes in nutrient use, nutrient depletion, metabolic tracing employing 13C-labeled substrates, and in vivo studies. We found that MACC1 permits numerous effects on cancer
metabolism. Most of those effects increased nutrient uptake. Furthermore, MACC1 alters metabolic pathways by affecting metabolite production or turnover from metabolic substrates. MACC1 supports use of glucose, glutamine and pyruvate via their increased depletion or altered distribution within metabolic pathways. In summary, we demonstrate that MACC1 is an important regulator of metabolism in cancer cells.
Background: Prevention of metastatic invasion is one of the main challenges in the treatment of alveolar rhabdomyosarcoma. Still the therapeutic options are limited. Therefore, an anti-tumor screening was initiated focusing on the anti-metastatic and anti-invasion properties of selected medicinal plant extracts and phytoestrogens, already known to be effective in the prevention and treatment of different cancer entities.
Methods: Treatment effects were first evaluated by cell viability, migration, invasion, and colony forming assays on the alveolar rhabdomyosarcoma cell line RH-30 in comparison with healthy primary cells.
Results: Initial anti-tumor screenings of all substances analyzed in this study, identified the plant extract of Vincetoxicum arnottianum (VSM) as the most promising candidate, harboring the highest anti-metastatic potential. Those significant anti-motility properties were proven by a reduced ability for migration (60%), invasion (99%) and colony formation (61%) under 48 h exposure to 25 μg/ml VSM. The restricted motility features were due to an induction of the stabilization of the cytoskeleton – actin fibers were 2.5-fold longer and were spanning the entire cell. Decreased proliferation (PCNA, AMT, GCSH) and altered metastasis (e. g. SGPL1, CXCR4, stathmin) marker expression on transcript and protein level confirmed the significant lowered tumorigenicity under VSM treatment. Finally, significant alterations in the cell metabolism were detected for
25 metabolites, with levels of uracil, N-acetyl serine and propanoyl phosphate harboring the greatest alterations. Compared to the conventional therapy with cisplatin, VSM treated cells demonstrated a similar metabolic shutdown of the primary cell metabolism. Primary control cells were not affected by the VSM treatment.
Conclusions: This study revealed the VSM root extract as a potential, new migrastatic drug candidate for the putative treatment of pediatric alveolar rhabdomyosarcoma with actin filament stabilizing properties and accompanied by a marginal effect on the vitality of primary cells.
Lipid droplets, the dynamic organelles that store Triglycerides (TG) and cholesterol esters (CE), are highly accumulated in colon cancer cells. This work studies the TG and CE subspecies profile in colon carcinoma cell lines, SW480 derived from primary tumor, and SW620 derived from a metastasis of the same tumor. It was previously reported that the total TG and CE content is dramatically higher in SW620 cells; however, TG and CE subspecies profile has not been investigated in detail. The work presented here confirms that the total TG and CE Content is significantly higher in the SW620 cells. Moreover, the fatty acid (FA) composition of TG is significantly altered in the SW620 cells, with significant decrease in the abundance of saturated triglycerides. This resulted in a significantly decreased TG saturation index in the SW620 cells. The saturation index of CE was also significantly decreased in the SW620 cells.
Laser metal deposition is a rapidly evolving method for additive manufacturing that combines high performance and simplified production routine. Quality of production depends on instrumental design and operational parameters that require constant control during the process. In this work, feasibility of using optical spectroscopy as a control method is studied via modeling and experimentally. A simplified thermal model is developed based on the time-dependent diffusion-conduction heat equation and geometrical light collection into detection optics. Intense light emitted by a laser-heated spot moving across a sample surface is collected and processed to yield the temperature and other temperature-related parameters. In a presence of surface defects the temperature field is distorted in a specific manner that depends on a shape and size of the defect. Optical signals produced by such the distorted temperature fields are simulated and verified experimentally using a 3D metal printer and a sample with artificially carved defects. Three quantities are tested as possible metrics for process monitoring: temperature, integral intensity, and correlation coefficient. The shapes of the simulated signals qualitatively agree with the experimental signals; this allows a cautious inference that optical spectroscopy is capable of detecting a defect and, possibly, predicting its character, e.g. inner or protruding.
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry.
Zearalenone (ZEN), an estrogenic mycotoxin produced by several species of Fusarium fungi, is a common contaminant of cereal-based food worldwide. Due to frequent occurrences associated with high levels of ZEN, maize oil is a particular source of exposure. Although a European maximumlevel for ZEN in maize oil exists according to Commission Regulation (EC) No. 1126/2007 along with a newly developed international standard method for analysis, certified reference materials (CRM) are still not available. To overcome this lack, the first CRM for the determination of ZEN in contaminated maize germ oil (ERM®-BC715) was developed in the frame of a European Reference Materials (ERM®) project according to the requirements of ISO Guide 35. The whole process of CRM development including preparation, homogeneity and stability studies, and value assignment is presented. The assignment of the certified mass fraction was based upon an in-house study using high-performance liquid chromatography isotope dilution tandem mass spectrometry. Simultaneously, to support the in-house certification study, an interlaboratory comparison study was conducted with 13 expert laboratories using different analytical methods. The certified mass fraction and expanded uncertainty (k=2) of ERM®-BC715 (362± 22) μg kg−1 ZEN are traceable to the SI. This reference material is intended for analytical quality control and contributes to the improvement of consumer protection and food safety.
A method, based on electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICP OES), has been optimized for direct solid sampling analysis of soda-lime glass - the most common type of industrially manufactured glass. This method allows fast and reliable quantification of the main elements - Al, Ca, K, Mg, Na, and Si - and trace elements - As, Ba, Cd, Ce, Co, Cr, Cu, Fe, Mn, Mo, Ni, (P), Pb, Sb, (Se), Sn, Sr, Ti, V, Zn, and Zr. In the presented ETV-ICP OES method, calibration is performed predominantly with matrix-free synthetic samples. This metrological advantage is normally not achieved with direct solid sampling methods and is one of the goals of the present study. In a certification interlaboratory comparison for the soda-lime glass CRM BAM-S005c, 2 out of 16 laboratories employed the ETV-ICP OES method. An improved analytical performance was obtained compared with the results of laboratories that used conventional liquid ICP OES. For both methods, the average relative deviations between the laboratory results and certified values as well as the average values of relative standard deviation were with a few exceptions <10%, in most cases even <5%, which indicated high trueness and precision.
X-ray absorption spectroscopy (XAS), in its various modalities, has gained exponential attention and applicability in the field of biological and biomedical systems. Particularly in this field, challenges like low concentration of analyte or proneness to radiation damage have certainly settle the basis for further analytical developments, when using X-ray based methods. Low concentration calls for higher sensitivity—by increasing the detection limits (DL); while susceptibility for radiation damage requires shorter measurement times and/or cryogenic sample environment possibilities. This manuscript reviews the latest analytical possibilities that make XAS more and more adequate to investigate biological or biomedical systems in the last 5 years.
Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes.
An alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry. For isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions, ranging from 0.06 to 0.99 mol mol–1, previously determined by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS). The calibration ML model was validated with two certified reference materials (LSVEC and IRMM-016). The procedure was applied toward the isotope amount ratio determination of a set of stock chemicals (Li2CO3, LiNO3, LiCl, and LiOH) and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. The results of these determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9 to 6.2‰. This precision was sufficient to resolve naturally occurring variations, as demonstrated for samples ranging from approximately −3 to +15‰. To assess its suitability to technical applications, the NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification. The results obtained were metrologically compatible with each other.
A recently introduced inductively coupled plasma-time-of-flight-mass spectrometer (ICP-ToF-MS) shows enhanced sensitivity compared to previous developments and superior isotope ratio precision compared to other ToF and commonly used single-collector ICP-MS instruments. Following this fact, an improvement for isotope dilution ICP-MS using the new instrumentation has been reported. This study aimed at investigating whether this improvement also meets the requirements of species-specific isotope dilution using GC/ICP-MS, where short transient signals are recorded. The results of the analysis of monomethylmercury (MMHg) of a sediment reference material show that isotope ratio precision of ICP-MS instruments equipped with quadrupole, sector-field, and time-of-flight mass analyzers is similar within a broad range of peak signal-to-noise ratio when analyzing one isotopic system. The procedural limit of quantification (LOQ) for MMHg, expressed as mass fraction of Hg being present as MMHg, w(Hg)MMHg, was similar as well for all investigated instruments and ranged between 0.003 and 0.016 μg/kg. Due to the simultaneous detection capability, the ICP-ToF-MS might, however, be more favorable when several isotopic systems are analyzed within one measurement. In a case study, the GC/ICP-ToF-MS coupling was applied for analysis of MMHg in sediments of Finow Canal, a historic German canal heavily polluted with mercury. Mass fractions between 0.180 and 41 μg/kg (w(Hg)MMHg) for MMHg, and 0.056 and 126 mg/kg (w(Hg)total) for total mercury were found in sediment samples taken from the canal upstream and downstream of a former chemical plant.
The allergenic and inflammatory potential of proteins can be enhanced by chemical modification upon exposure to atmospheric or physiological oxidants. The molecular mechanisms and kinetics of such modifications, however, have not yet been fully resolved. We investigated the oligomerization and nitration of the grass pollen allergen Phl p 5 by ozone (O3), nitrogen dioxide (NO2), and peroxynitrite (ONOO–). Within several hours of exposure to atmospherically relevant concentration levels of O3 and NO2, up to 50% of Phl p 5 were converted into protein oligomers, likely by formation of dityrosine cross-links. Assuming that tyrosine residues are the preferential site of nitration, up to 10% of the 12 tyrosine residues per protein monomer were nitrated. For the reaction with peroxynitrite, the largest oligomer mass fractions (up to 50%) were found for equimolar concentrations of peroxynitrite over tyrosine residues. With excess peroxynitrite, the nitration degrees increased up to 40% whereas the oligomer mass fractions decreased to 20%. Our results suggest that protein oligomerization and nitration are competing processes, which is consistent with a two-step mechanism involving a reactive oxygen intermediate (ROI), as observed for other proteins. The modified proteins can promote pro-inflammatory cellular signaling that may contribute to chronic inflammation and allergies in response to air pollution.
Background - It is known that dietary intake of polyunsaturated fatty acids may improve cardiac function. However, relatively high daily doses are required to achieve sufficient cardiac concentrations of beneficial omega‐3 fatty acids. The liver X receptor (LXR) is a nuclear hormone receptor and a crucial regulator of lipid homeostasis in mammals. LXR activation has been shown to endogenously reprogram cellular lipid profiles toward increased polyunsaturated fatty acids levels. Here we studied whether LXR lipid reprogramming occurs in cardiac tissue and exerts cardioprotective actions.
Methods and Results - Male 129SV mice were treated with the LXR agonist AZ876 (20 µmol/kg per day) for 11 days. From day 6, the mice were injected with the nonselective β‐agonist isoproterenol for 4 consecutive days to induce diastolic dysfunction and subendocardial fibrosis while maintaining systolic function. Treatment with isoproterenol led to a marked impairment of global longitudinal strain and the E/e' ratio of transmitral flow to mitral annular velocity, which were both significantly improved by the LXR agonist. Histological examination showed a significant reduction in isoproterenol‐induced subendocardial fibrosis by AZ876. Analysis of the cardiac lipid composition by liquid chromatography‐high resolution mass spectrometry revealed a significant increase in cardiac polyunsaturated fatty acids levels and a significant reduction in saturated fatty acids by AZ876.
Conclusions - The present study provides evidence that the LXR agonist AZ876 prevents subendocardial damage, improves global longitudinal strain and E/e' in a mouse model of isoproterenol‐induced cardiac damage, accompanied by an upregulation of cardiac polyunsaturated fatty acids levels. Cardiac LXR activation and beneficial endogenous cardiac lipid reprogramming may provide a new therapeutic strategy in cardiac disease with diastolic dysfunction.
Over the last few years, the Federal Institute for material research (BAM, Berlin) together with the Centre for the Study of Manuscript Cultures (CSMC, University of Hamburg) have initiated a systematic material investigation of black inks produced from Late Antiquity to the Middle Ages (ca. fourth century CE–fourteenth/fifteenth centuries CE), aimed primarily at extending and complementing findings from previous sporadic studies. Part of this systematic investigation has focused on Egyptian Coptic manuscripts, and the present preliminary study is one of its outputs. It centres on a corpus of 45 Coptic manuscripts—43 papyri and 2 ostraca—preserved at the Palau-Ribes and Roca-Puig collections in Barcelona. The manuscripts come from the Monastery of Apa Apollo at Bawit, one of the largest monastic settlements in Egypt between the Late Antiquity and the Early Islamic Period (sixth–eighth centuries CE). The composition of their black inks was investigated in situ using near-infrared reflectography (NIRR) and X-ray fluorescence (XRF). The analyses determined that the manuscripts were written using different types of ink: pure carbon ink; carbon ink containing iron; mixed inks containing carbon, polyphenols and metallic elements; and iron-gall ink. The variety of inks used for the documentary texts seems to reflect the articulate administrative system of the monastery of Bawit. This study reveals that, in contrast to the documents, written mostly with carbon-based inks, literary biblical texts were written with iron-gall ink. The frequent reuse of papyrus paper for certain categories of documents may suggest that carbon-based inks were used for ephemeral manuscripts, since they were easy to erase by abrasion.
A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run.
Ergot alkaloids are mycotoxins formed by fungi of the Claviceps genus, which are some of the most common contaminants of food and feed worldwide. These toxins are a structurally heterogeneous group of compounds, sharing an ergoline backbone. Six structures and their corresponding stereoisomers are typically quantified by either HPLC-FLD or HPLC-MS/MS and the values subsequently summed up to determine the total ergot alkaloid content. For the development of a screening method targeting all ergot alkaloids simultaneously, the alkaloids need to be transferred to one homogeneous structure: a lysergic acid derivative. In this study, two promising cleaving methods—acidic esterification and hydrazinolysis—are compared, using dihydroergocristine as a model compound. While the acidic esterification proved to be unsuitable, due to long reaction times and oxidation sensitivity, hydrazinolysis reached a quantitative yield in 40-60 min. Parallel workup of several samples is possible. An increasing effect on the reaction rate by the addition of ammonium iodide was demonstrated. Application of hydrazinolysis to a major ergot alkaloid mix solution showed that all ergopeptines were cleaved, but ergometrine/-inine was barely affected. Still, hydrazinolysis is a suitable tool for the development of a sum parameter screening method for ergot alkaloids in food and feed.
A new method combining isotope dilution mass spectrometry (IDMS) and standard addition has been developed to determine the mass fractions w of different elements in complex matrices: (a) silicon in aqueous tetramethylammonium hydroxide (TMAH), (b) sulfur in biodiesel fuel, and (c) iron bound to transferrin in human serum. All measurements were carried out using inductively coupled plasma mass spectrometry (ICP–MS). The method requires the gravimetric preparation of several blends (bi)—each consisting of roughly the same masses (mx,i) of the sample solution (x) and my,i of a spike solution (y) plus different masses (mz,i) of a reference solution (z).
Only these masses and the isotope ratios (Rb,i) in the blends and reference and spike solutions have to be measured. The derivation of the underlying equations based on linear regression is presented and compared to a related concept reported by Pagliano and Meija. The uncertainties achievable, e.g., in the case of the Si blank in extremely pure TMAH of urel (w(Si)) = 90% (linear regression method, this work) and urel (w(Si)) = 150% (the method reported by Pagliano and Meija) seem to suggest better applicability of the new method in practical use due to the higher robustness of regression analysis.
SnOct2 (Sn(II) 2-ethylhexanoate) catalyzed ROPs of L-lactide were performed in bulk with eight different alcohols as initiators. The time was varied between 1 h and 24 h for all initiators. For two initiators the temperature was also lowered to 115 ◦C. Even-numbered chains were predominantly formed in all polymerizations at short times, but the rate of transesterification (e.g. even/odd equilibration) and the molecular weight distribution were found to depend significantly on the nature of the initiator. Observed transesterification reactions also continued in solid poly (L-lactide), and with the most active initiator, almost total equilibration was achieved even at 130 ◦C. This means that all chains including those of the crystallites were involved in transesterification reactions proceeding across the flat surfaces of the crystallites. The more or less equilibrated crystalline polylactides were characterized by DSC and SAXS measurements with regard to their melting temperature (Tm), crystallinity and crystal thickness.
Poor air quality, particularly in urban areas, causes various diseases and degrades living standards. Air Quality could be affected by emissions of odor, Volatile Organic Compounds (VOCs), and other gases. Therefore, assessment and monitoring of odorous air quality using sensitive, simple, rapid, accurate and portable tools is very important for public health. This study aimed to characterize odor emissions to detect malfunctions in facilities and to prevent air pollution and olfactory nuisance in the environment. A gas chromatographic method, in conjunction with sensorial analysis were performed for odorous air samples analysis collected from neighborhood of Meknes city (Morocco). Advanced multivariate statistical approaches, such as Principal Components Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to describe samples similarities. The electronic nose (e-nose) data processing exhibits a satisfactory discrimination between the odorous air samples. Twenty-four VOCs with known molecular formulas were identified with Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS). A validated Partial Least Square (PLS) model foresees good calibration between e-nose measurement and TD-GCMS analysis. The finding indicates that TD-GC–MS approach in conjunction with e-nose unit could be suitable tool for environmental measurement-based odor emissions.
The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods.
Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction Desorption gas chromatography–mass spectrometry (TED-GC–MS).
A set of strained aromatic macrocycles based on [n]cyclo2,7-(4,5,9,10-tetrahydro)pyrenylenes is presented with size dependent photophysical properties. The K-region of pyrene was functionalized with ethylene glycol groups to decorate the outer rim and thereby confine the space inside the macrocycle. This confined space is especially pronounced for n = 5, which leads to an internal binding of up to 8.0×104 M–1 between the ether-decorated [5]cyclo-2,7-pyrenylene and shape complementary crown ether–cation complexes.
Both, the ether-decorated [n]cyclo-pyrenylenes as well as one of their host–guest complexes have been structurally characterized by single crystal X-ray analysis. In combination with computational methods the structural and thermodynamic reasons for the exceptionally strong binding have been elucidated. The presented rim confinement strategy makes cycloparaphenylenes an attractive supramolecular host family with a favorable, size-independent read-out signature and binding capabilities extending beyond fullerene guests.