Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (33)
- Vortrag (30)
- Posterpräsentation (9)
- Beitrag zu einem Sammelband (1)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- GDMS (5)
- ICP-MS (4)
- Messunsicherheit (3)
- Metrology (3)
- Atomic Force Microscopy (2)
- Calibration (2)
- GD-MS (2)
- GD-OES (2)
- GUM (2)
- Gadolinium-based contrast agents (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (22)
- 1.6 Anorganische Referenzmaterialien (19)
- 1.1 Anorganische Spurenanalytik (6)
- S Qualitätsinfrastruktur (5)
- S.1 Qualität im Prüfwesen (5)
- 9 Komponentensicherheit (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.3 Instrumentelle Analytik (2)
- 1.4 Prozessanalytik (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
Eingeladener Vortrag
- nein (30)
Within the framework of a German government project (initiated by the Federal Environment Agency) to check the compliance of commercially available batteries with the German Battery Ordinance concerning their heavy metal contents, 18 different types of commercially available zinc-air button cells were analysed for their cadmium, lead and mercury contents. After microwave assisted dissolution with aqua regia, Cd and Pb were determined using inductively coupled plasma mass spectrometry (ICP-MS), and Hg was determined using inductively coupled plasma optical emission spectrometry (ICP OES) and atomic absorption spectrometry. Cd contents were found to be much lower than the permitted limits; Pb contents were also found to be below the limits. Hg contents were found to be near the limits, and in one case the limit was exceeded.
The objective of this work was to test the compliance of commercially available batteries with the German Battery Ordinance, a project of the German government that was initiated by the Federal Environment Agency. Different types of commercially available dry cells were analysed for their cadmium, lead and mercury contents. The dry cells underwent mechanical pre-treatment, separation of the different components and microwave-assisted digestion before determination of the heavy metals. Mercury is sometimes added to prevent the generation of gaseous hydrogen from the electrochemical process. Lead could be present since it is sometimes used as an alloying element of zinc. Cadmium has no technical importance and is an undesirable impurity. None of the batteries contained higher heavy metal mass fractions than the permissible limits.
An intercomparison study of analytical methods for the determination of magnesium in low alloy steel
(2012)
In an intercomparison study three low alloy steel materials were analyzed on their content of the trace element Mg, and five different analytical techniques were used, namely spark-OES, inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS), inductively coupled plasma quadrupole mass spectrometry (ICP-QMS), and glow discharge mass spectrometry (GD-MS). Solid steel discs were used for analysis with spark-OES and GD-MS. For the analyses with ICP-OES, ICP-TOFMS, and ICP-QMS steel chips were wet-digested in aqua regia, and the wet-digestion was performed either in polypropylene tubes placed in a heating block or in Teflon pressure vessels using a microwave assisted system. The Mg concentrations obtained for the three steel materials were: 2.0, 2.8, and 10.3 µg g-1, respectively, and the spread in results was acceptable, giving RSD values in the range of 2030%.
We have developed a very fast and entirely gas-phase based purification technique for carbon nanotubes (CNT) that allows removing metal and metal oxide impurities with high effectiveness. CNT agglomerates from chemical vapor deposition (CVD) synthesis which contained carbon encapsulated catalysts were injected into an atmospheric plasma torch. Very high heating rates allow for quasi-instantaneous vaporization of catalyst particles. This way, metal vapors are hyposized to break mechanically instable encapsulations and effuse from incomplete ones faster than thermally induced graphitization stabilizes such particle encapsulations. The ash content of multi-walled (MW) CNT samples was reduced to less than 15% of the initial value within a few milliseconds. Also the metal content of single-walled (SW) CNT agglomerates was significantly reduced. Repeated injection of CNT agglomerates into the plasma torch resulted in higher-purity products of improved structural integrity and increased oxidation resistance.
Hydrophilic interaction chromatography (HILIC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) was optimized for speciation analysis of gadolinium-based contrast agents in environmental samples, in particular surface river waters and plants. Surface water samples from the Teltow channel, near Berlin, were investigated over a distance of 5 km downstream from the influx of a wastewater treatment plant. The total concentration of gadolinium increased significantly from 50 to 990 ngL-1 due to the influx of the contrast agents. After complete mixing with the river water, the concentration remained constant over a distance of at least 4 km. Two main substances [Dotarem® (Gd-DOTA) and Gadovist® (Gd-BT-DO3A)] have been identified in the river water using standards. A gadolinium-based contrast agent, possibly Gd-DOTA (Dotarem®), was also detected in water plant samples taken from the Teltow channel. Therefore, uptake of contrast agents [Gadovist® (Gd-BTDO3A), Magnevist® (Gd-DTPA), Omniscan® (Gd-DTPA-BMA), Dotarem® (Gd-DOTA), and Multihance® (Gd-BOPTA)] by plants was investigated in a model experiment using Lepidium sativum (cress plants). HILICICP-MS was used for identification of different contrast agents, and a first approach for quantification using aqueous standard solutions was tested. For speciation analysis, all investigated contrast agents could be extracted from the plant tissues with a recovery of about 54 % for Multihance® (Gd-BOPTA) up to 106 % for Gadovist® (Gd-BT-DO3A). These experiments demonstrate that all contrast agents investigated are transported from the roots to the leaves where the highest content was measured.
The certification of a boron carbide reference material for chemical composition is described. The mass fractions of 16 elements and two boron species are certified in an international interlaboratory comparison with 35 participating laboratories from six different countries. Beside chemical characterization the certification process includes homogeneity and stability testing of the candidate material boron carbide (type F360, 305M422). Details of the analytical methods used for chemical characterization and of the calculation of the uncertainties of the certified mass fractions are given. The new reference material ERM®-ED102 with certified mass fractions of 18 parameters (elements and species) and of the amount fraction of the isotope 10B is a valuable tool for laboratories working in the field of advanced ceramic materials analysis to improve their analytical results.