Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2019 (208) (entfernen)
Dokumenttyp
- Vortrag (98)
- Zeitschriftenartikel (67)
- Posterpräsentation (36)
- Beitrag zu einem Tagungsband (2)
- Dissertation (2)
- Buchkapitel (1)
- Preprint (1)
- Forschungsbericht (1)
Sprache
- Englisch (161)
- Deutsch (45)
- Mehrsprachig (2)
Schlagworte
- ICP-MS (13)
- Mikroplastik (13)
- Process Analytical Technology (12)
- Isotope analysis (9)
- LIBS (9)
- Laser ablation (9)
- Online NMR Spectroscopy (9)
- CONSENS (8)
- Digitalisierung (8)
- HR-CS-MAS (8)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (158)
- 1.1 Anorganische Spurenanalytik (46)
- 6 Materialchemie (40)
- 1.4 Prozessanalytik (38)
- 1.6 Anorganische Referenzmaterialien (28)
- 1.7 Organische Spuren- und Lebensmittelanalytik (28)
- 1.8 Umweltanalytik (28)
- 6.6 Physik und chemische Analytik der Polymere (21)
- 6.3 Strukturanalytik (18)
- 1.9 Chemische und optische Sensorik (13)
Eingeladener Vortrag
- nein (98)
The high ionization potentials and low wavelength emission lines of halogens difficult the analysis of their organohalogen compounds by ICP-based methods [1]. Other techniques, such as combustion ion chromatography (CIC) or ion-selective electrodes have proven to be more reliable to determine these elements. However, these techniques are more time-consuming and/or have lower precision and accuracy.
High resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS) allows the determination of solid and liquid samples by monitoring a molecule formed with the analyte and a molecule forming reagent. In the case of F, Cl and Br, several molecule forming agents have been studied for their determination. Among all of them, calcium can form a stable bond with the three elements and provides optimal analytical properties for trace analysis [2]. However, the spectral window of commercially available continuum source AAS instruments is not broad enough to cover the wavelength range necessary for a simultaneous determination. Thus, coupling it with a modular simultaneous echelle spectrograph (MOSES), which can register around 200 nm in a single measure, allows the simultaneous study of the three analytes [3].
This instrumentation is capable of register more than 200 nm of the spectra per measure keeping a high resolution. This spectral window is suitable for the monitorization of a variety of transitions of the three molecules. However, some of them are overlapped and the competitive mechanism of formation of the three molecules modify their sensitivity depending on the proportions in the sample.
In this study, a compromise in the conditions and modifiers were selected in order to maximize the sensitivity and signal to noise ratio for the three molecules. The determination was carried out by standard addition of CaF and Cl and Br were obtained from the PLS model.
References:
[1] X. Bu, T. Wang, G. Hall, J. Anal. At. Spectrom., 18, 1443–1451 (2003)
[2] M. Resano, E. García-Ruiz, M. Aramendía, M. A. Belarra, J. Anal. At. Spectrom., 34, 59–80 (2019)
[3] S. Geisler, M. Okruss, H. Becker-Ross, M. Dong Huang, N. Esser, S. Florek, Spectrochimica Acta PartB, 107, 11–16 (2015)
The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence a risky venture. We think that it is crucial to improve the screening process to eliminate most of the immanent deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and simultaneous performance of competition experiments. The latter can directly be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones and blank supernatant has been designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the IgG concentration, which is unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration is not possible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media had been used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system, we conclude that this approach should be preferable to most other protocols leading to many of false positives, causing expensive and lengthy confirmation steps to weed out the poor clones.
During R/V Meteor cruise 141/1, pore fluids of near surface sediments were investigated to find indications for hydrothermal activity in the Terceira Rift (TR), a hyperslow spreading center in the Central North Atlantic Ocean. To date, submarine hydrothermal fluid venting in the TR has only been reported for the D. João de Castro seamount, which presently seems to be inactive. Pore fluids sampled close to a volcanic cone at 2,800‐m water depth show an anomalous composition with Mg, SO4, and total alkalinity concentrations significantly higher than seawater and a nearby reference core. The most straightforward way of interpreting these deviations is the dissolution of the hydrothermally formed mineral caminite (MgSO4 0.25 Mg (OH)2 0.2H2O). This interpretation is corroborated by a thorough investigation of fluid isotope systems (δ26Mg, δ30Si, δ34S, δ44/42Ca, and 87Sr/86Sr). Caminite is known from mineral assemblages with anhydrite and forms in hydrothermal recharge zones only under specific conditions such as high fluid temperatures and in altered oceanic crust, which are conditions generally met at the TR. We hypothesize that caminite was formed during hydrothermal activity and is now dissolving during the waning state of the hydrothermal system, so that caminite mineralization is shifted out of its stability zone. Ongoing fluid circulation through the basement is transporting the geochemical signal via slow advection toward the seafloor.
Unter den von Humboldt in Amerika erworbenen Schriftstücken der Kolonialzeit findet sich eine Tributliste aus dem Jahr 1569, die der Otomí Bevölkerung aus dem Ort Mizquahuala im Staat Hidalgo/ Mexiko zugeordnet wird. Sie ist in Form eines Kalenders ausgeführt, Wochentage und verschiedene Produkte lassen sich unterscheiden. Eduard Seler beschreibt dieses Manuskript zusammen mit einer weiteren Tributliste, die in Inhalt und Zeichnung anders gestaltet ist, jedoch ebenfalls aus dieser Region stammt.
Mit den für die Analyse von Manuskripten bewährten Untersuchungsmethoden werden Papier und Farbmittel identifiziert. Hierzu zählen Raman-, FTIR-, Röntgenfluoreszenz- und VIS- Spektroskopie. Charakteristisch für die Herstellung von schriftlichen Dokumenten in der Kolonialzeit von Amerika ist die Verwendung von indigenem Material wie Papier aus Baumrinde und Pflanzenfarben zusammen mit den aus Europa bekannten Materialien. Geklärt wird, welche Auswahl von Farbstoffen zur Herstellung der Dokumente genutzt wurde, die diese als Gruppe klassifizieren könnte.
Die den beiden Fragmenten zugeordneten Farbmaterialien sowie formale und inhaltliche Aspekte lassen vermuten, dass zwei weitere Schriftstücke der Berliner Sammlung `Manuscripta Americana´, deren Herkunft nicht bekannt ist, mit ihnen in Beziehung gebracht werden können. Stilistisch gleiche Fragmente befinden sich zudem in Mexiko, Paris und den USA.
Im Vergleich dieser Fragmente untereinander wird diskutiert, inwieweit die über die Materialanalyse identifizierten spezifischen Farbstoffe einen Hinweis auf eine gemeinsame lokale Herkunft zulassen.
The presence of any aflatoxin contamination in exported figs needs to be monitored and measured through reliable and traceable methods, which require pure and matrix certified reference materials. On the other hand, certified reference materials (CRM) for determination of aflatoxins in dried fig are not yet available. Moreover, there is a lack of CRMs to be used in routine testing laboratories for method validation and quality control. The routine testing laboratories, participating in commercial proficiency testing (PT) programs, use the results available from consensus values to evaluate the performance of the participating laboratories, rather than metrologically traceable assigned values. This study initially proposed as a key comparison and presented at the EURAMET TC-MC SCOA meeting in Malta in 2015 and subsequently at the CCQM OAWG meeting in April 2015, proposes a CRM candidate for determination of levels of aflatoxins B1, B2, G1, G2 and their total in dried. Evidence of successful participation in formal, relevant international comparisons are needed to document measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs).
In total nine NMI/DI participated in the Track C Key Comparison CCQM-K138 Determination of aflatoxins (AFB1, AFB2, AFG1, AFG2 and Total AFs) in Dried Fig. Participants were requested to evaluate the mass fractions expressed in ng/g units, of aflatoxins B1, B2, G1, G2 and total aflatoxin in a dried food matrix, dried fig. The CCQM-K138 results for the determination of aflatoxins (AFB1, AFB2, AFG1, AFG2 and total AFs) are ranging from 5.17 to 7.27 ng/g with an %RSD of 10.47 for AFB1, ranging from 0.60 to 0.871 ng/g with an %RSD of 11.69 for AFB2, ranging from 1.98 to 2.6 ng/g with an %RSD of 10.36 for AFG1, ranging from 0.06 to 0.32 ng/g with an %RSD of 35.6 for AFG2, and ranging from 8.29 to 10.31 ng/g with an %RSD of 7.69 for Total AFs. All participants based their analyses on LC-MS/MS, HPLC-FLD, HR-LC/MS, and IDMS. Brief descriptions of the analytical methods used by the participants, including sample preparation, analytical technique, calibrants, and quantification approach are summarized in Appendix F. Linear Pool was used to assign the Key Comparison Reference Values (KCRVs) for B1, B2, G1, G2 and total aflatoxins. Due to the traceability requirements for the calibrants not being met, results of KEBS, INTI, VNIIM and BAM were excluded from KCRV determination.
Successful participation in CCQM-K138 demonstrates the following measurement capabilities in determining mass fraction of organic compounds, with molecular mass of 100 g/mol to 500 g/mol, having high polarity (pKow > -2), in mass fraction range from 0.05 ng/g to 500 ng/g in dried food matrices.
Grasses accumulate silicon in the form of silicic acid, which is precipitated as amorphous silica in microscopic particles termed phytoliths. These particles comprise a variety of morphologies according to the cell type in which the silica was deposited. Despite the evident morphological differences, phytolith chemistry has mostly been analysed in bulk samples, neglecting differences between the varied types formed in the same species. In this work, we extracted leaf phytoliths from mature plants of Sorghum bicolor (L.) Moench. Using solid state NMR and thermogravimetric analysis, we show that the extraction methods alter greatly the silica molecular structure, its condensation degree and the trapped organic matter. Measurements of individual phytoliths by Raman and synchrotron FTIR microspectroscopies in combination with multivariate analysis separated bilobate silica cells from prickles and long cells, based on the silica molecular structures and the fraction and composition of occluded organic matter. The variations in structure and composition of sorghum phytoliths suggest that the biological pathways leading to silica deposition vary between these cell types.
Die Geräteentwicklungen im Bereich der Niederfeld-NMR-Spektroskopie im vergangenen Jahrzehnt ermöglichen den Einsatz kompakter, portabler Magnete mit geringen Streufeldern in Laborumgebungen und industriellen Produktionsanlagen. Somit werden neue Möglichkeiten für hochauflösende NMR-Experimente zur Reaktionsüberwachung eröffnet. Im Rahmen des EU-Projekts CONSENS wurden die Möglichkeiten dieser Methode umfassend anhand einer technisch bedeutenden Reaktion (elektrophile aromatische Substitutionsreaktionen) evaluiert.
Um die Flexibilität einer kontinuierlichen und modularen Pilotanlage durch Echtzeit- Qualitätskontrolle zu fördern, wurde ein vollständig automatisiertes Online- NMR-Modul entwickelt. Der Einsatz eines kommerziellen Niederfeld-NMR-Geräts im industriellen Umfeld wurde durch die entwickelten Lösungen der automatisierten Datenanlyse sowie durch ein zertifiziertes Sicherheitskonzept für den Betrieb in explosionsgefährdeten Zonen ermöglicht. Neben der Überwachung der Produktqualität wurden Online-NMR-Daten in einem neuen iterativen Optimierungsansatz zur Maximierung des Anlagenertrags eingesetzt und dienten als zuverlässige Referenz für die Kalibrierung eines Nahinfrarot-Spektrometers.
Für die Entwicklung einer robusten Datenauswertung der NMR-Spektren, die dem Anspruch der Flexibilität bei Produktwechseln genügt, wurden zunächst Versuche im Labormaßstab durchgeführt, um eine Datenbasis zu schaffen. In diesen Versuchen wurden die aromatischen Amine Anilin, p-Toluidin und p-Fluoranilin mit o-Fluornitrobenzol gekoppelt. Durch Zugabe einer Organolithium-Verbindung (Li- HMDS) findet ein Protonenaustausch zwischen dem primären Amin und Li-HMDS statt. Dies führt zu einer hohen Reaktionsenthalpie und instabilen Aryllithium-Verbindungen. Die Reaktionen wurden hinsichtlich anfallender Zwischenprodukte mittels Hochfeld-NMR-Spektroskopie analysiert.
Nachfolgend wurden die Reaktionen sowohl im Semi-Batch-Verfahren als auch im kontinuierlichen Laborbetrieb mit Online-Niederfeld-NMR-Spektroskopie und Online- Hochfeld-NMR-Spektroskopie untersucht. Da die gemessenen NMR-Spektren besonders im aromatischen Spektralbereich hohe Signalüberlappungen der Reaktanden aufweisen, wurden chemometrische Modelle entwickelt und anhand der Hochfeld-NMR-Methode validiert. Die verwendeten Durchflusszellen für die Niederfeld-NMR-Spektroskopie wurden hinsichtlich ihrer Anwendbarkeit für quantitative Messungen im kontinuierlichen Durchfluss untersucht. Es konnte gezeigt werden, dass Messungen mit einer additiv gefertigten Keramikdurchflusszelle prinzipiell möglich sind.
Vortrag zur Bestimmung von Nichtmetallen in Carbiden halten.
Hierbei geht es um die Bestimmung von C, O und N in Vanadiumcarbid, Wolframcarbid und Niobcarbidmaterialien, einen hierzu durchgeführten Ringversuch mit Beteiligung der Kollegen des AK Sonderwerkstoffe und den Vergleich von Verfahrenskenngrößen.
Acoustically levitated droplets have been suggested as compartmentalized, yet wall-less microreactors for high-throughput reaction optimization purposes. The absence of walls is envisioned to simplify up-scaling of the optimized reaction conditions found in the microliter volumes. A consequent pursuance of high-throughput chemistry calls for a fast, robust and sensitive analysis suited for online interrogation. For reaction optimization, targeted Analysis with relatively low sensitivity suffices, while a fast, robust and automated sampling is paramount. To follow this approach, in this contribution, a direct coupling of levitated droplets to a homebuilt ion mobility spectrometer (IMS) is presented. The sampling, Transfer to the gas phase, as well as the ionization are all performed by a single exposure of the sampling volume to the resonant output of a mid-IR laser. Once formed, the nascent spatially and temporally evolving analyte ion cloud needs to be guided out of the acoustically confined trap into the inlet of the ion mobility spectrometer. Since the IMS is operated at ambient pressure, no fluid dynamic along a pressure Gradient can be employed. Instead, the transfer is achieved by the electrostatic potential gradient inside a dual ring electrode ion optics, guiding the analyte ion cloud into the first stage of the IMS linear drift tube accelerator. The design of the appropriate atmospheric pressure ion optics is based on the original vacuum ion optics design of Wiley and McLaren. The obtained experimental results nicely coincide with ion trajectory calculations based on a collisional model.
Perhaps due in no small part to its historical mystique, mechanochemistry has been shrowded in relative obscurity for quite some time. The successes of mechanochemistry in organic synthesis have often been curtailed by a fundamentally limited mechanistic understanding. Lately, however, the community has made great strides towards understanding the fundamentals, as well as large steps forward regarding industrially significant scale-up via twin-screw extrusion. A variety of recent work has traded in some of mechanochemistry’s mystique for simple, straight-forward chemical guidelines.
Um in einem veränderten Umfeld erfolgreich bestehen zu können, müssen Chemieunternehmen neue Pfade beschreiten. Dazu gehört insbesondere das Potential digitaler Technologien. Mit flexiblen, modularen chemischen Vielzweck-Produktionsanlagen lassen sich häufig wechselnde Produkte mit kürzeren Vorlauf- und Stillstandzeiten zwischen den Kampagnen und dennoch hoher Qualität realisieren. Intensivierte, kontinuierliche Produktionsanlagen erlauben auch den Umgang mit schwierig zu handhabenden Substanzen.
Grundvoraussetzung für solche Konzepte ist eine hochautomatisierte "chemische" Prozesskontrolle zusammen mit Echtzeit-Qualitätskotrolle, die "chemische" Informationen über den Prozess bereitstellt. In einem Anwendungsbeispiel wurde eine pharmazeutische Lithiierungsreaktion aus einer modularen Pilot-Anlage betrachtet und dabei die Vorzüge eines vollautomatischen NMR-Sensors untersucht. Dazu wurde ein kommerziell erhältliches Benchtop-NMR-Spektrometer mit Permanentmagnet auf die industriellen Anforderungen, wie Explosionsschutz, Feldkommunikation und vollautomatischer, robuster Datenauswertung angepasst. Der NMR-Sensor konnte schließlich erfolgreich im vollautomatischen Betrieb nach fortschrittlichen Regelkonzepten und für die Echtzeitoptimierung der Anlage getestet werden. Die NMR-Spektroskopie erwies sich als hervorragende Online-Methode und konnte zusammen mit einer modularen Datenauswertung sehr flexibel genutzt werden. Die Methode konnte überdies als zuverlässige Referenzmethode zur Kalibrierung konventioneller Online-Analytik eingesetzt werden.
Zukünftig werden voll integrierte und intelligent vernetzte "smarte" Sensoren und Prozesse eine kontinuierliche Produktion von Chemikalien und Pharmazeutika mit vertretbaren Qualitätskosten möglich machen.
Metabolites from Alternaria fungi exhibit a variety of biological properties such as phytotoxic, cytotoxic, or antimicrobial activity. Optimization of a literature procedure culminated in an efficient total synthesis of (−)-altenuene as well as a stable isotope-labeled derivative suitable for implementation in a LC-MS/MS method for mycotoxin analysis.
In many scientific fields, isotopic analysis can offer valuable information, e.g., for tracing the origin of food products, environmental contaminants, forensic and archaeological samples (provenance determination), for age determination of minerals (geochronological dating) or for elucidating chemical processes. Up to date, typically bulk analysis is aimed at measuring the isotopic composition of the entire elemental content of the sample. However, the analyte element is usually present under the form of different species. Thus, separating species of interest from one another and from matrix components prior to isotope ratio measurements can provide species-specific isotopic information, which could be used for tracing the origin of environmental pollutants and elucidation of (environmental) speciation. Using on-line hyphenations of separation techniques with multicollector-ICP-MS (MC-ICP-MS) can save time and effort and enables the analysis of different species during a single measurement.
In this work, we developed an on-line hyphenation of CE with multicollector-ICP-MS (CE/MC-ICP-MS) for isotopic analysis of sulfur species. With this method, the isotopic composition of sulfur in sulfate originating from river water could be analyzed without sample preparation. The results were compared with data from off-line analysis of the same samples to ensure accuracy. The precision of the results of the on-line measurements was high enough to distinguish the rivers from one another by the isotopic signature of the river water sulfate. Next to environmental applications, a future field could be species-specific isotopic analysis of biomolecules, as sulfur is the only covalently bound constituent of proteins which can be analyzed by MC-ICP-MS.
Unternehmen der chemischen Industrie müssen neuen Pfade beschreiten, um in einem veränderten Umfeld erfolgreich bestehen zu können. Dazu gehört insbesondere, das Potenzial digitaler Technologien zu nutzen. Die volle Integration und intelligente Vernetzung von Systemen und Prozessen kommt allerdings nur zögerlich voran. Dieser Beitrag ist ein Loblied auf die Feldebene. Er möchte dazu ermutigen, die Digitalisierung der Prozessindustrie auf Basis smarter Sensorik, Aktorik und Kommunikation ganzheitlicher zu denken und informiert über aktuelle technische Perspektiven, wie das Ein-Netzwerk-Paradigma, Ad-hoc-Vernetzungen, Edge-Computing, FPGAs, virtuelle Maschinen oder Blockchain. Diese geben smarter Sensorik, Aktorik und Kommunikation eine völlig neue Perspektive.
Multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) has evolved significantly since its introduction in 1992. The second and third generation instruments now allow isotope ratio measurements at unprecedented precisions, 0.001 % or better. However, precision alone is not enough for producing accurate and reliable isotope ratio measurements. Metrological considerations such as the selection of suitable calibration strategies, proper assessment of instrumental biases, and the estimation of overall measurement uncertainty remain critical to the measurement process. Properly assessed, measurement uncertainty then provides the interval within which a result can be considered both accurate and precise.
All mass spectrometric measurements are affected by instrumental mass discrimination and produce isotope ratios that are biased relative to their “true” ratio. To produce accurate and traceable isotope ratio measurements, it is imperative that certified isotope reference materials (iCRMs) be used for calibration and validation purposes. iCRMs reporting absolute isotope ratios are an analyst’s first choice, particularly when its uncertainty is sufficient for the intended use. However, when smaller uncertainties are required to resolve subtle differences between samples, delta-scale measurements become important. Here, the difference between an isotope ratio measured in a sample and in an internationally accepted isotope reference material (iRM) is determined. This deviation can be positive or negative relative to the iRM, is called a delta value, and is often expressed in per mil units.
This presentation will highlight the potential for MC-ICP-MS to produce isotope ratio measurements with minimal uncertainties by examining three applications involving Mg isotopes: 1) the certification of a set of iCRMs for their absolute isotope ratio using a gravimetric isotope mixture approach; 2) the comparison of these iCRMs with currently accepted Mg delta-scale reference materials through intercalibration, and 3) the determination of isotope fractionation exponents for geochemical applications.
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe (polybromierte Flammschutzmittel) in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.
Warfarin als ein Vertreter der NSO-Hetereozyklen, ist seit den 1950er Jahren einer der bekanntesten Gerinnungshemmer. Beim Menschen wird es bis heute zur Vorbeugung von Thrombose und der Behandlung von Vorhofflimmern und Arrhythmie eingesetzt. Doch schon einige Jahre vor der FDA Zulassung als Medikament wurde es zur Bekämpfung von Nagetieren eingesetzt. Bis heute wurde es nur teilweise durch weitaus wirksamere antikoagulante Rodentizide (ARs) der zweiten Generation, sogenannte Superwarfarine, ersetzt. In der Fachliteratur finden sich zahlreiche Beispiele für sekundäre und tertiäre Vergiftung mit ARs bei Wildtieren und anderen Nichtzieltieren. Bisher ist relativ wenig über die Bioakkumulation, Persistenz und Toxizität von ARs und deren Transformationsprodukten (TPs) in der terrestrischen und aquatischen Umwelt, sowie der Nahrungskette bekannt.
Um Einblicke in mögliche Transformations- und Abbauprozesse von Warfarin zu erhalten und um Umwelteinflüsse zu simulieren, wurde es in einer elektrochemischen Reaktorzelle oxidativ umgesetzt und mittels Massenspektrometrie analysiert. Hinsichtlich der Wasseraufbereitung in Kläranlagen wurden technisch relevante Simulationsverfahren wie Chlorung, UV-Bestrahlung und Ozonung angewendet um potentielle Eliminierungswege aufzuklären. Gebildete Transformationsprodukte wurden daher mittels unterschiedlicher chromatografischer Verfahren getrennt, massenspektrometrisch analysiert und verglichen.
Die Wettbewerbsfähigkeit der Prozessindustrie basiert auf der Sicherung der geforderten Produktqualität bei einer optimalen Nutzung von Anlagen, Rohstoffen und Energie. Ein Weg zur wissensbasierten Produktion führt über die Betrachtung der wesentlichen Apparate-, Prozess- und Freigabedaten aus Betrieben und Labors. Das Potenzial dieser Daten wird heute vielfach noch nicht konsequent für ein umfassendes Verständnis der Produktion genutzt.
Neben Fragen zur Datenerfassung, Datenkonnektivität und Datenintegrität müssen solche Daten für eine ganzheitliche Prozessanalyse zunächst mit Kontextinformationen zusammengebracht werden. Datenquellen enthalten Zeitwertpaare, aber auch diskrete Daten aus LIMS (Laboratory Information Management Systems) oder ELN (Electronic Laboratory Notebooks) und werden zunehmend durch 2D- und 3D-Daten aus der Chromatographie-Massenspektrometrie oder bildbasierter Analytik ergänzt.
Für die automatisierte Merkmalsextraktion, etwa zur Extraktion chemischer Informationen aus den oben genannten Datenquellen werden multivariate Werkzeuge und Algorithmen genutzt. Multivariate Statistiken wie PCA (Principle Component Analysis), PLS (Partial Least Squares) und LDA (Latent Discriminant Analysis) bilden die erste Grundlage für die Datenanalyse. Für diese Verfahren sind heute Datenvorbehandlungsschritte nötig. Die Modellbildung geschieht manuell und ist sehr aufwendig.
Können diese Daten im Zeitalter von ML (Machine Learning) und KI (Artificial Intelligence) anderweitig sinnvoll genutzt werden und ohne klassische Modellbildung? Die Bezeichnung „Big Data“ als Voraussetzung für datengetriebene Auswerteverfahren ist für die Prozessindustrie allerdings unpassend, denn auch bei mengenmäßig großen Datensätzen liegen für Kampagnen typischerweise nur Informationen über einige Batches mit einer Serie von Messdaten vor, die genügend Varianz für eine datengetriebene Auswertung aufweisen – nicht vergleichbar mit den Datenmengen im WWW oder von großen Internet-Konzernen.
Ein Weg zur wissensbasierten Produktion führt über die Betrachtung der wesentlichen Apparate-, Prozess- und Freigabedaten aus Betrieben und Labors. Das Potenzial dieser Daten wird heute vielfach noch nicht konsequent für ein umfassendes Verständnis der Produktion genutzt.
Neben Fragen zur Datenerfassung, Datenkonnektivität und Datenintegrität müssen solche Daten für eine ganzheitliche Prozessanalyse zunächst mit Kontextinformationen zusammengebracht werden. Datenquellen enthalten vor allem Zeitwertpaare, die numerisch vorbehandelt und möglichst vollautomatisch ausgewertet werden müssen. Am Beispiel NMR-spektroskopischer Daten wird der Stand der Auswertung mit physikalisch motivierten Modellen, wie z. B. dem IHM erläutert.
Advances and Applications of Molecular Absorption Spectrometry: from Non-Metals to Isotope Analysis
(2019)
The present work covers two main aspects of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS), an analytical technique for elemental trace analysis.
First, a comprehensive mechanistic study of molecule formation in graphite furnaces is presented, which is a key step into the recovery of analytical signals. For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in HR-CS-GFMAS. A zirconium coating catalyzes the CaF formation, and its structure was investigated. The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. Here a mechanism is proposed, where ZrO2 works as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface.
Second, analytical methods were developed by using HR-CS-MAS as detector for non-metals and isotope analysis. Therefore, the determination of organic absorbable chlorine in water, the quantification of fluorine in consume care products with declared perfluorinated ingredients, and the determination of sulfur content in crude oils were investigated. Finally, the high resolution of the instrumentation allows to measure isotopic shifts with high precision in some observed molecular spectra. Consequently, the molecular spectra of enriched isotopes of boron and magnesium were investigated, establishing so the potential of HR-CS-MAS for the accurate and precise determination of isotopic amount ratios.
Zusammenfassung
Die vorliegende Arbeit befasst sich mit zwei zentralen Aspekten der High-Resolution-Continuum-Source-Molekülabsorptionsspektrometrie mit Graphitrohrtechnik (HR-CS-GFMAS), einer Analysetechnik für elementare Spurenanalyse.
Der erste Teil der Arbeit umfasst eine mechanistische Studie zur Molekülbildung auf Graphitoberflächen. Dies ist ein wichtiger Schritt, um analytische Signale zu entdecken. Dazu wurde die Molekülbildung von CaF analysiert, welches für die indirekte, analytische Bestimmung von Fluor in HR-CS-GFMAS genutzt wird. Die CaF Bildung wurde mittels einer Beschichtung aus Zirconium katalysiert und deren Struktur analysiert. Die Kinetik dieser Reaktion wurde durch Beobachtung des jeweiligen Molekülspektrums bei verschiedenen Atomisierungstemperaturen beobachtet. Ein Arrheniusplot zeigte für Fluor (n = 1) eine Reaktion Pseudo-erster Ordnung. Ein Übergangszustand wurde über die mit Zirconium überzogene Grafitoberfläche isoliert und seine Struktur mittels spektroskopischer Methoden Energiedispersive Rasterelektronenmikroskopie / Röntgenspektroskopie (REM-EDX), Röntgenphoto¬elektronenspektroskopie (XPS), Röntgenabsorptionsspektroskopie (XAS) und Raman Spektroskopie untersucht. Auf Grundlage dieser Ergebnisse wird ein Mechanismus vorgeschlagen, bei dem ZrO2 als heterogener Katalysator fungiert; in Folge einer Pyrolysestufe wird ein Übergangszustand des ZrO(OCaF) aktiviert, welcher bei höheren Temperaturen CaF(g) an der Zirconium-Graphitoberfläche freisetzt.
Im zweiten Teil der Arbeit werden Analysemethoden entwickelt, in dem HR-CS-MAS als Detektor für Nichtmetalle und Isotopanalyse angewandt wird. Hierfür wurde organisch gebundenes Chlor im Wasser bestimmt, der Fluorgehalt in Pflegeprodukten mit perfluorierten Inhaltsstoffen quantifiziert und der Schwefelgehalt in Erdöl untersucht. Weiterhin ermöglicht die hohe Auflösung der Messgeräte eine präzise Bestimmung der Isotopenverschiebung einiger untersuchter Molekülspektren. Daher wurden die Molekülspektren angereicherter Bor- und Magnesiumisotope untersucht. Auf diese Weise wurde das Potential von HR-CS-MAS für die akkurate und präzise Bestimmung von Isotop-Mengenverhältnissen nachgewiesen.
Magnesium is a major element in the hydrosphere and biosphere, and it is direct correlated with the carbon cycle. Therefore, the study of its isotopic fractionation in sediments and sea water helps to understand the earth’s climate and global warming. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg, and traditionally isotope amount ratios are measured by mass spectrometric methods. Their drawbacks include the high costs for instruments and their operation, experienced operators and elaborate time-consuming chromatographic sample preparation. Recently, an optical spectrometric method has been proposed as faster and low-cost alternative for the analysis of isotope ratios: high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS).
For the determination of Mg isotope ratios in selected rock reference materials, the high-resolution molecular absorption spectrum of in-situ generated MgF molecule was studied applying multivariate analysis and the results compared with MC-ICP-MS. Samples were dissolved by acid digestion and Mg isotopes analyzed with and without matrix extraction. The absorption spectra were recorded for MgF for the electronic transition X 2Σ → B 2Σ+. The MgF spectrum is described as the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF. The isotope analysis was done by deconvolution of the MgF spectrum by partial least square regression (PLS). A PLS model was built and calibrated with enriched isotope spikes and certified reference materials. Spectra data was preprocessed by a derivate of second order and venetian blinds cross-validation was employed for finding the optimum latent variables. Finally, the model was refined by a genetic algorithm which identified the best subset of variables for a precise and accurate regression. Results are compatible with those obtained by MC-ICP-MS with an accuracy of ± 0.3‰ with uncertainties ranging between 0.02 to 0.6‰. This accuracy and precision discriminate the isotope fractionation in geological samples, and it is suitable for earth’s climate studies.
Is it a parmesan cheese from Italy? Who painted the Mona Lisa? The determination of the place of origin is essential for consumer protection, detection of falsifications, and also to bring justice.
All the tangible possess an isotopic fingerprint. However, current technologies are too expensive. We work on the development of fast and low-cost optical instruments and methods for isotope analysis.
Simultaneous multielemental analysis of crude oils by high-resolutions absorption spectrometry
(2019)
When crude oil arrives at a refinery it needs a lot of processing before it is suitable for cracking into lighter fractions. Sulfur has to be extracted to meet ultra-low sulfur legislation for most of the fuel grades, and desalination is a crucial process as chlorine within salts is corrosive to refinery equipment. Measuring the amounts of sulfur and chlorine within crude oil is the first step in a complex clean-up process.
Heavy metals, such as vanadium, nickel and iron need to be removed too. These metals can poison the catalyst used to crack the oil into lighter fractions. This is costly as it reduces the useful life of the catalyst. Like chlorine, heavy metals also have a corrosive effect on the plant. There is some evidence that the presence of some metals in the final product can reduce performance.
A fast determination of elements and size of suspended particles is vital for diagnosis and safeguard of refinery equipment. However, sample preparation for current analytical methods consumes precious time and lost particle size information.
High-resolution continuum source graphite furnace absorption spectrometry (HR-CS-GFAS) is proposed as a fast analytical method for elemental determination in crude oils and potentially for simultaneous multielement and particle size analysis. This HR-CS-GFAS instrumentation is coupled to a modular simultaneous echelle spectrometer (MOSES) and provides a full optical window with high resolution (from 180 to 900 nm with bandwidth λ/170,000). By using this set-up, it is possible to generate a multiparameter 3D spectral image (atomic and molecular lines, isotopic shift, atomization delay, and intensities). The generated spectral images can be analyzed by multivariate regressions for the elemental and particle size analysis. Additionally, if several atomic and molecular lines are simultaneously measured, they may be used in multi-energy calibration (MEC), a method based on the use of many wavelengths of the same absorbing/emitting entity to improve the accuracy in analytical atomic spectrometry. This MEC approach combined with multivariate image analysis allows the quantification of selected elements (Si, Al, Ni, Fe, V, S, and Cl) and overcomes matrix effects.
Society for Applied Spectroscopy (SAS) Atomic Section Student Award.
Magnesium is a major element in the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg. It is due to their relatively large mass difference (~8% between) that isotope fractionation leads to slight variations of isotope amount ratios in biological, environmental and geological samples. Traditionally, isotope ratios are measured by mass spectrometric methods. Their drawbacks include the high costs for instruments and their operation, experienced operators and elaborate time-consuming chromatographic sample preparation.
Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS), and laser ablation molecular isotopic spectrometry (LAMIS).
For the determination of Mg isotope ratios in selected rock reference materials, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied and their results compared with MC-ICP-MS. By HR-CS-MAS, samples were dissolved by acid digestion and Mg isotopes analyzed with and without matrix. The absorption spectrum was recorded for MgF for the electronic transitions X 2Σ → A 2 Πi, and X 2Σ → B 2Σ+. In the case of LAMIS, we investigated the MgF molecule for the electronic transition A 2Πi → X 2Σ, as well as direct analysis by the MgO molecule for the electronic transition A 1Π+ → X 1Σ. The MgF and MgO spectra are described as the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO. The isotope analysis was done by deconvolution of the MgF spectrum by partial least square regression (PLS) calibrated with enriched isotope spikes. Results were accurate with precisions ranging between 0.2 ‰ and 0.8 ‰ (2 SD, n= 10) for HR-CS-GFMAS. No statistically significant differences were observed for samples w/o matrix extraction. On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of direct analysis, however the precision is lower due the lack of solid isotopic calibration standards.
Is it a parmesan cheese from Italy? Who painted the Mona Lisa? The determination of the place of origin is essential for consumer protection, detection of falsifications, and also to bring justice.
All the tangible possess an isotopic fingerprint. However, current technologies are too expensive. We work on the development of fast and low-cost optical instruments and methods for isotope analysis.
Magnesium (Mg) is a major element in a range of silicate and carbonate minerals, the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg with natural abundances of 79 %, 10 %, and 11 %, respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight variations of isotope amount ratios n(26Mg)/n(24Mg) in biological, environmental and geological samples. Traditionally, isotope ratios are measured by mass spectrometric methods and isotope ratios are expressed as deviation from an internationally agreed upon material, i.e. the zero-point of the δ-value scale. Drawbacks of this method include the high costs for instruments and their operation, experienced operators and elaborate, time-consuming chromatographic sample preparation.
Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high- resolution continuum source graphite furnace molecular absorption spectrometry (HR- CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS).
For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X2Σ → A2Πi and X 2Σ → B2Σ+ around wavelengths 358 nm and 268 nm, respectively. In the case of LAMIS, we investigated the MgF molecule for the electronic transition A2Πi → X2Σ as well as the MgO molecule for the electronic transition A1Π+ → X1Σ around 500 nm. The MgF and MgO spectra are described by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by partial least square regression (PLS) calibrated with enriched isotope spikes. Isotope amount ratios in rock samples with and without matrix separation were analyzed. Calculated δ-values were accurate and obtained with precisions ranging between 0.2 ‰ and 0.5 ‰ (1 SD, n = 10). On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared to MC-ICP-MS.
Magnesium is a major element in the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg. It is due to their relatively large mass difference (~8% between) that isotope fractionation leads to slight variations of isotope amount ratios in biological, environmental and geological samples. Traditionally, isotope amount ratios are measured by mass spectrometric methods. Their drawbacks include the high costs for instruments and their operation, experienced operators and elaborate time-consuming chromatographic sample preparation. Recently, an optical spectrometric method has been proposed as faster and low-cost alternative for the analysis of isotope ratios: high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS).
For the determination of Mg isotope ratios in selected rock reference materials, the high-resolution molecular absorption spectrum of in-situ generated MgF molecule was studied applying multivariate analysis and the results compared with MC-ICP-MS. Samples were dissolved by acid digestion and Mg isotopes analyzed with and without matrix. The absorption spectra were recorded for MgF for the electronic transition X 2Σ → B 2Σ+. The MgF spectrum is described as the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF. The isotope analysis was done by deconvolution of the MgF spectrum by partial least square regression (PLS). A PLS model was built and calibrated with enriched isotope spikes and certified reference materials. Spectra data was preprocessed by a derivate of second order and venetian blinds cross-validation was employed for finding the optimum latent variables. Finally, the model was refined by a genetic algorithm which identified the best subset of variables for a precise and accurate regression. Results are compatible with those obtained by MC-ICP-MS with an accuracy of ± 0.3‰ with uncertainties ranging between 0.02 to 0.6‰.
Boron and Magnesium present two and three stable isotopes respectevely. It is due to their relatively large mass difference (~ 10%) that isotope fractionation leads to considerable isotope amount ratio variations in the nature. These have been used as a proof of provenance of mineral and biological samples, to estimate a contamination source and to the determination of geological processes by erosion or subduction. Additionally, boron is employed in the nuclear industry due to the capability of its isotope 10B to thermal-neutron capture and therefore 10B enriched boric acid solutions are used in the cooling system of thermonuclear facilities and in the alloying of steel and carbides for protective shielding. Traditionally, isotope ratio variations have been determined by mass spectroscopic methods.
Here an alternative faster and low cost method for isotope ratio determination is proposed: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Isotope amount ratios have been determined by monitoring the absorption spectrum of boron monohydride (BH) for boron and Magnesium monofluoride (MgF) for magnesium in a graphite furnace HR-CS-MAS. Bands (0→0) and (1→1) were evaluated. Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression was built. Results obtained are metrologically compatible with those reported by mass spectrometric methods. Moreover, a precision and accuracy of the method of ± 0.5 ‰. This accuracy and precision is comparable with those obtained by thermal ionization mass spectrometry (TIMS) and multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) for boron isotope ratio measurements
Magnesium is a naturally occurring element that can be found in several mineral forms in the earth crust. This element presents three stable isotopes 24Mg, 25Mg and 26Mg with a natural abundance of 79%, 10%, and 11% respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight isotope amount ratio variations n(26Mg)/n(24Mg) in biological and geological samples. Traditionally, isotope amount ratios have been measured by mass spectrometric methods. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time-consuming. Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS). For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X 2Σ → A 2 Πi and X 2Σ → B 2Σ+ around wavelengths 358 nm and 268 nm respectively. In the case of LAMIS, it was studied the MgF molecule for the electronic transitions A 2Πi → X 2Σ as well as the MgO molecule for the electronic transition A 1Π+ → X 1Σ around 500 nm. The MgF and MgO spectra are composed by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by a partial least square regression (PLS) calibrated with enriched isotope spikes. The isotope amount ratios in rock samples with and without matrix separation were analyzed. Resulting delta values were obtained with precisions ranging between 0.2-0.5 ‰. On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared with MC-ICP-MS.
Mass spectrometric Methods MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
Optical spectrometric methods are proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS) and laser ablation molecular isotopic spectrometry (LAMIS). First, stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated heteronuclear diatomic molecules (MH or MX) in graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. Finally, the application of molecular spectrometry via emission by LAMIS is compared and discussed.
Chemical companies must find new paths to successfully survive in a changing environment. The potential of digital technologies belongs to these. Flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short down-times between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds.
Therefore, fully automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. The advances of a fully automated NMR sensor were exploited, using a given pharmaceutical lithiation reaction as an example process within a modular pilot plant. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as , e.g., explosion safety, field communication, and robust evaluation of sensor data. It was thereof used for direct loop advanced process control and real-time optimization of the process. NMR appeared as preeminent online analytical tool and allowed using a modular data analysis tool, which even served as reliable reference method for further PAT applications.
In future, such fully integrated and intelligently interconnecting “smart” systems and processes can speed up the high-quality production of specialty chemicals and pharmaceuticals.
Multiple sclerosis (MS) is the most common acquired neurological disease affecting Young adults. It leads to myelin destruction and formation of lesions in the brain and permeabilization of the blood-brain barrier (BBB).
Gadolinium based contrast agents (GBCA), used for diagnosis and monitoring by MRI, might accumulate in tissue, including brain. Using an animal model, application of linear and macrocyclic GBCA was investigated. Analysis was performed by laser ablation inductively coupled plasma (LA-ICP) MS. This method works as a bioimaging tool for sample thin sections and allows to identify regions of accumulated Gd in the samples.
In healthy and diseased mice, inflammationmediated changes in the brain were investigated by application of GBCA. The mean objective is to understand the changes in inflamed tissue and correlate alterations of the BBB by LA-ICP-MS (Imaging Mass Cytometry).
Real-time monitoring of newly acidified organelles during autophagy in living cells is highly desirable for a better understanding of intracellular degradative processes. Herein, we describe a reaction-based boron dipyrromethene (BODIPY) dye containing strongly electron-withdrawing diethyl 2-cyanoacrylate groups at the α-positions. The probe exhibits intense red fluorescence in acidic organelles or the acidified cytosol while negligible fluorescence in other regions of the cell. The underlying mechanism is a nucleophilic reaction at the central meso-carbon of the indacene core, resulting in the loss of π-conjugation entailed by dramatic spectroscopic changes of more than 200 nm between its colorless, non-fluorescent leuco-BODIPY form and its red and brightly emitting form. The reversible transformation between red fluorescent BODIPY and leuco-BODIPY along with negligible cytotoxicity qualifies such dyes for rapid and direct intracellular lysosome imaging and cytosolic acidosis detection simultaneously without any washing step, enabling the real-time monitoring of newly acidified organelles during autophagy.
Trialkoxysilane haben sich in den vergangenen Jahren als vielseitig einsetzbare Organosilane erwiesen. Die Einsatzgebiete erstrecken sich vom Witterungsschutz von Bauwerken über haftvermittelnde Eigenschaften in der Glasfaserindustrie, bei Dicht- und Klebstoffen, in Farben und Lacken bis hin zur Modifizierung von polymeren Werkstoffen.
Kommerzielle Benchtop-NMR-Spektrometer haben das Potential auch im Bereich der Silanchemie als Online-Methode zur Reaktionsüberwachung und für die Qualitätskontrolle eingesetzt zu werden. Interessante NMR-Kerne für die oben genanntem Produkte sind 1H und 29Si. In einer gemeinsamen Forschungskooperation zwischen EVONIK und BAM wurde anhand verschiedener Fallstudien die Anwendbarkeit der Niederfeld-NMR-Spektroskopie zur chemischen Analyse von Silanen evaluiert. Im Zuge der Fallstudien wurde gezeigt, wie Niederfeld-NMR-Spektroskopie die Möglichkeiten der Konzentrationsmessung auf neue Anwendungsgebiete erweitert, in denen bestehende Technologien wie z. B. NIR, Raman, UV/VIS, etc. mangels Referenzdaten nicht quantitativ eingesetzt werden können.
Fallstudie 1: Oligomerisierung
Eine Fallstudie setzte dazu an, den Hydrolyse- und Kondensationsverlauf mit einer geeigneten Online-NMR-Analytik zu beobachten, den Reaktionsfortschritt der Hydrolyse und Kondensation auf dieser Basis besser zu verstehen und zu optimieren. Zu diesem Zweck werden durch Zugabe von Wasser zunächst die Alkoxysubstituenten eines Trialkoxysilans hydrolysiert und entsprechende Silanole gebildet. Diese können dann über eine SiOH-Funktion an den zu modifizierenden Werkstoff anbinden und über weitere Silanolgruppen unter Ausbildung von Siloxaneinheiten vernetzen.
Fallstudie 2: Spaltung von cyclischen Silanverbindungen
In einer weiteren Fallstudie wurde die Kinetik der Aufspaltungen einer cyclischen Silanverbindung untersucht. Die Online-NMR-Analytik kam hierbei sowohl im Labor als auch in der industriellen Produktionsanlage zum Einsatz. Hierfür wurde eine vollständig automatisierte Einhausung verwendet, welche den Einsatz eines kommerziellen NMR-Spektrometers in explosionsgeschützten Bereichen ermöglicht.
Fallstudie 3: Qualitätskontrolle für Produktmischungen von Trialkoxysilanen
Für Produktmischungen eines Trialkoxysilans und weiteren Bestandteilen wie u. a. org. Stabilisatoren, Organozinnverbindungen, eines aromatischen Amins und org. Peroxide wurden quantitative 1H-Spektren akquiriert und eine automatische Auswertungsmethode basierend auf Indirect Hard Modeling (IHM) entwickelt. Für die Nebenkomponenten, deren Stoffmengenanteile bis zu 3 Mol-% betragen, wurden durch die zugrunde gelegte Methode typischerweise korrekte experimentelle Stoffmengenanteile gefunden, die weniger als 0,2 Mol-% vom Referenzwert abweichen.
Antifoulingmittel im Wasser
(2019)
In most chemical reactions, stable isotopes are fractionated in a mass-dependent manner, yielding correlated isotope ratios in elements with three or more stable isotopes. The proportionality between isotope ratios is set by the triple isotope fractionation exponent θ that can be determined precisely for, e.g., sulfur and oxygen by IRMS, but not for metal(loid) elements due to the lower precision of MC-ICP-MS analysis and smaller isotopic variations. Here, using Mg as a test case, we compute a complete metrologically robust uncertainty budget for apparent θ values and, with reference to this, present a new measurement Approach that reduces uncertainty on θ values by 30%. This approach, namely, direct educt-product bracketing (sample−sample bracketing), allows apparent θ values of metal(loid) isotopes to be determined precisely enough to distinguish slopes in three-isotope space. For the example of Mg, we assess appropriate quality Control standards for interference-to-signal ratios and Report apparent θ values of carbonate−seawater pairs. We determined apparent θ values for marine biogenic carbonates, where the foraminifera Globorotalia menardii yields 0.514 ± 0.005 (2 SD), the coral Porites, 0.515 ± 0.006 (2 SD), and two specimens of the giant clam Tridacna gigas, 0.508 ± 0.007 (2 SD) and 0.509 ± 0.006 (2 SD), documenting differences in the uptake pathway of Mg among marine calcifiers. The capability to measure apparent θ values more precisely adds a new dimension to metal(loid) δ values, with the potential to allow us to resolve different modes of fractionation in industrial and natural processes.
Zu den letzten beiden Jahrestagungen der GUS wurden Verfahren und Methoden vorgestellt, die es gestatten, den Transfer von Schadstoffen aus Materialien und Produkten in die Umwelt unter umweltrelevanten Bedingungen beschreiben zu können. Dabei lag der Fokus auf den Materialien und der eingesetzten Umweltsimulationen. In einem sich anschließenden Schritt soll nun das Verhalten der freigesetzten organischen Schadstoffe unter den Bedingungen von realen und simulierten Umwelteinflüssen charakterisiert und beschrieben werden. Hier werden im Detail drei potentielle Schadstoffe betrachtet, die Inhaltsstoffe bzw. Additive in den jeweils eingesetzten Materialien sind. Im Falle von Polypropylen (PP) und Polystyrol (PS) handelt es sich um polybromierte Flammschutzmittel BDE 209 (Decabrom-diphenylether, als Einzelsubstanz) und HBCD (Hexabromcyclododecan, als technische Formulierung). Für das eingesetzte Polycarbonat ist BPA (Bisphenol A) als Schadstoff zu definieren, welcher unter umweltrelevanten Bedingungen freigesetzt wird. Im Rahmen der durchzuführenden Arbeiten sollen die aufgeführten prioritären Schadstoffe hinsichtlich möglicher Transformationsprozesse in Umwelt und Klärwerk charakterisiert werden. Die unter den Bedingungen der Ozonung, Chlorierung und UV-Bestrahlung erhaltenen Transformationsprodukte (TPs) sollen im Sinne einer Non-Target-Analytik identifiziert und eindeutig charakterisiert werden. Die Ergebnisse sollen mittels vorhandener Analysenverfahren, wie GC-EI-MS, HPLC-ESI-IT-MSn bzw. LC-MS/MS erzeugt bzw. abgesichert werden. Anhand der in der Struktur eindeutig zu beschreibenden Transformationsprodukte und der Charakterisierung von potentiellen Intermediaten sollen belastbare Reaktionswege und –mechanismen abgeleitet werden.
In addition to previously reported results on the accelerated weathering of polystyrene samples (PS) containing 1 wt.% hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene samples (PP) containing 0.1 wt.% BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006. For the determination of BDE-209 in the collected raining water the samples were prepared in accordance to a validated protocol. Before the analyses each sample was spiked with isotopically labeled BDE-209. Subsequently the samples were extracted with isooctane. The obtained extracts were concentrated, and the resulting solutions were analyzed by GC/MS. Additionally, the total bromine content was monitored for the weathered and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF) as a non-destructive and rapid method. In general, the resulting data from the accelerated weathering will be compared to those from the natural weathering experiments. Here, the surfaces of the test pieces were analyzed by LA-ICP-MS and XRF as well. Moreover, soil bed tests were conducted in a well characterized model soil. This soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining basin inside of an air-conditioned cellar. In this manner, TOC, water capacity and humidity are recorded parameters. To induce a leaching process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. A defined humidity is a fundamental parameter for a biological activity in the soil. The test polymers were placed up to the half in the soil. Microbial activity of the soil is monitored by a reference polymer (polyurethane) and should induce the release of HBCD and BDE-209 out of the test materials. These released analytes will be captured by passive samplers (silicone tubes) placed in a distinct distance to the polymer samples in the soil. The soil bed experiments are complementary to the weathering experiments due to the biological activity in the soil.
In addition to previously reported results on the accelerated weathering of polystyrene samples (PS) containing 1 wt.% hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene samples (PP) containing 0.1 wt.% BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006. For the determination of BDE-209 in the collected raining water the samples were prepared in accordance to a validated protocol. Before the analyses each sample was spiked with isotopically labeled BDE-209. Subsequently the samples were extracted with isooctane. The obtained extracts were concentrated, and the resulting solutions were analyzed by GC/MS. Additionally, the total bromine content was monitored for the weathered and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF) as a non-destructive and rapid method. In general, the resulting data from the accelerated weathering will be compared to those from the natural weathering experiments. Here, the surfaces of the test pieces were analyzed by LA-ICP-MS and XRF as well. Moreover, soil bed tests were conducted in a well characterized model soil. This soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining basin inside of an air-conditioned cellar. In this manner, TOC, water capacity and humidity are recorded parameters. To induce a leaching process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. A defined humidity is a fundamental parameter for a biological activity in the soil. The test polymers were placed up to the half in the soil. Microbial activity of the soil is monitored by a reference polymer (polyurethane) and should induce the release of HBCD and BDE-209 out of the test materials. These released analytes will be captured by passive samplers (silicone tubes) placed in a distinct distance to the polymer samples in the soil. The soil bed experiments are complementary to the weathering experiments due to the biological activity in the soil.
Warfarin, also known as Coumadin is one of the most popular anticoagulant drugs used as a therapeutic in humans to prevent thrombosis, atrial fibrosis, and fibrillation since the 1950s. Because of its ability to hinder blood from clotting by blocking vitamin K-depending carboxylation of blood clotting precursors, it is also used as a rodenticide worldwide. Until today it has been partially substituted by far more potent anticoagulant rodenticides (ARs), so-called superwarfarins. There are numerous references confirming secondary and tertiary poisoning in non-target-animals and wildlife like mammals, birds, and fish associated with ARs. Up to now relatively little is known about persistence and toxicity of transformation products of those AR in the environment and food chain. Herein, warfarin was chosen as a model compound to determine andelucidate TPs which are generated technically and under environment-like conditions. Such as the simulation of the oxidative phase I metabolism by implementing electrochemical flow cells coupled to mass spectrometry (MS). Obtained results are being compared to TPs generated by UVB-irradiation and ozonation.
Analysis and separation of degradation products and TPs were achieved by a variety of gas- and liquid chromatographic techniques coupled to (high resolution) MS.
Environmental sustainability and –stability of materials concerning the migration of pollutants
(2019)
In addition to previously reported results on the accelerated weathering of polystyrene samples (PS) containing 1 wt. % hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene samples (PP) containing 0.1 wt. % BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006. For the determination of BDE-209 in the collected raining water the samples were prepared in accordance to a validated protocol. Before the analyses each sample was spiked with isotopically labeled BDE-209. Subsequently the samples were extracted with isooctane. The obtained extracts were concentrated, and the resulting solutions were analyzed by GC/MS. Additionally, the total bromine content was monitored for the weathered and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF) as a non-destructive and rapid method. In general, the resulting data from the accelerated weathering will be compared to those from the natural weathering experiments. Here, the surfaces of the test pieces were analyzed by LA-ICP-MS and XRF as well. Moreover, soil bed tests were conducted in a well characterized model soil. This soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining basin inside of an air-conditioned cellar. In this manner, TOC, water capacity and humidity are recorded parameters. To induce a leaching process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. A defined humidity is a fundamental parameter for a biological activity in the soil. The test polymers were placed up to the half in the soil. Microbial activity of the soil is monitored by a reference polymer (polyurethane) and should induce the release of HBCD and BDE-209 out of the test materials. These released analytes will be captured by passive samplers (silicone tubes) placed in a distinct distance to the polymer samples in the soil. The soil bed experiments are complementary to the weathering experiments due to the biological activity in the soil.
Elementanalytische Verfahren werden heute zu mehr eingesetzt als bloß zur Bestimmung von Metallgesamtgehalten in diversen Probenmatrizes. Sie stellen heute ein wichtiges Werkzeug zur Beantwortung lebenswissenschaftlicher Fragen aus Umwelt, Medizin und Biologie dar. In der vorliegenden Arbeit kommt die single-cell-ICP-Flugzeitmassenspektrometrie (single-cell-ICP-TOF-MS) zur Multielementanalytik in einzelnen Kieselalgen (Diatomeen) zum Einsatz und wird zukünftig ein wichtiges Werkzeug z.B. bei der Beantwortung
ökotoxikologischer Fragestellung sein.
In den vergangen Jahren hat das Umweltbewusstsein in der Bevölkerung stark zugenommen und somit auch das Interesse an der Vermeidung von anthropogenen (Schad-)Stoffen in der Umwelt. Eine (neue) Substanzklasse, deren Umweltauswirkungen noch nicht vollständig untersucht sind und die in den vergangenen Jahren immer mehr an Bedeutung gewonnen hat, sind (metallbasierte) Nanomaterialien. Im Gegensatz zu bspw. Elementspezies weisen Nanomaterialien eine Vielzahl von Eigenschaften auf und lassen sich nicht über nur ein Merkmal beschreiben - dies stellt eine große analytische Herausforderung dar. Hier haben sich vor allem die Feld-Fluss-Fraktionierung (AF4) und die single-particle-ICP-MS als leistungsstarke analytische Methoden herausgestellt. In (aquatischen) Umweltmatrizes (z.B. Oberflächengewässern) liegen neben artifiziellen auch natürliche Partikel vor, was eine weitere große Herausforderung für den Nachweis von Nanomaterialien darstellt.
Neben dem Nachweis von anthropogenen Stoffen in der Umwelt ist zudem deren ökotoxikologische Bewertung wichtig. In der aquatischen Ökotoxikologie werden hierzu Testorganismen mit den jeweiligen Substanzen über die Wasserphase exponiert. Effektkonzentrationen (EC50) werden dabei auf Basis der Konzentrationen in der Wasserphase abgeleitet - tatsächlich bioakkumulierte Mengen werden hierbei jedoch meist nicht ermittelt; eine weitere große Herausforderung besteht zudem in der Bewertung von Mischungstoxizitäten. Gängige Testorganismen sind u.a. Kieselalgen (Diatomeen). Diatomeen stehen am Anfang der Nahrungskette - toxikologisch relevante Metalle/Nanomaterialien können sich hierüber im Nahrungsnetz der Oberflächengewässer anreichern und ggf. nachhaltig auswirken.
Im ersten Teil des Vortrages werden zunächst neue elementanalytische Methoden zum Nachweis von metallbasierten Nanopartikeln in Umweltmatrizes auf Basis der AF4/ICP-SFMS sowie stabilen Isotopenlabeln am Beispiel von Eisennanopartikeln vorgestellt.
Im zweiten Teil wird eine neue elementanalytische Methode als komplementäre Technik zur ökotoxikologischen Bewertung von (Schad-)Stoffen vorgestellt. Die neue Methode basiert auf der on-line Kopplung von HPLC mit der single-cell-ICP-(ToF)-MS (sc-ICP-(ToF)-MS) [1, 3-5]. Hierüber konnten wir erfolgreich die automatisierte Multielementanalytik einzelner Diatomeen realisieren und zur Analyse von mit Metallen inkubierten Diatomeen (cyclotella meneghiniana) einsetzen. Wir konnten zeigen, dass die sc-ICP-ToF-MS zukünftig eine leistungsstarke, komplementäre Technik in der aquatischen Ökotoxikologie zum z.B. Test von Metallen und Nanomaterialien darstellt.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
In recent years, elemental imaging of biological samples like tissue thin sections using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining more and more importance. Improvements concerning spatial resolution as well as signal-to-background ratio due to low-dispersion sample chambers make LA-ICP-MS also interesting for single cell analysis.
To evaluate the interaction of nanoparticles (NPs) with cells LA-ICP-MS was applied for the imaging of individual cells. Our findings show, that NP aggregates can be localized within cellular compartments. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures (size, chemical composition, surface modification), as well as on the incubation conditions (concentration, time).
Moreover, LA-ICP-MS is increasingly becoming an important complementary technique in bioanalysis by using element-tagging strategies to determine biomolecules indirectly. Based on the specific binding between antibodies and their corresponding antigens, proteins and peptides can be detected in tissue or cells using tagged antibodies. As artificial tags metal chelates loaded with lanthanides, polymer-based elemental tags or metal-containing nanoparticles can be used. Thereby LA-ICP-MS is a sensitive detection tool for multiplexed immuno-histochemistry of tissue and cell samples.
Our results demonstrate the potential of LA-ICP-MS to investigate the distribution of naturally occurring elements, administered agents as well as biomolecules by using metal-tagged antibodies.
Die metallischen Verunreinigungen in Metallen lassen sich mittels hochauflösender Massenspektrometer relativ einfach ermitteln. Die Glimmentladungs-Massenspektrometrie (GD-MS) stellt hierfür eine schnelle Multielementmethode dar. Aufgrund ihrer höheren Anregungs- und Ionisationsenergien ist die Bestimmung von Nichtmetallen eine weit größere Herausforderung. Außerdem fehlt es an für die direkte Feststofftechnik notwendigen Kalibrierstandards z.B. in Form zertifizierter Referenzmaterialien. Für die quantitative Bestimmung von Verunreinigungen wurden mit Standards dotierte Pulverpresslinge und dotierte, gesinterte Materialien auf ihre Eignung als Kalibrierstandards für die GD-MS untersucht. Dabei kamen unterschiedliche Plasmabedingungen (gepulster/ kontinuierlicher Betrieb; verschiedene Plasmagase) zum Einsatz. Ein Überblick über analytische Kenngrößen und Grenzen der verwendeten Kalibrierstrategien wird gegeben. Zur Validierung des Verfahrens wurde die hochauflösende Continuum Source Absorptionsspektrometrie (HR-CS-MAAS) verwendet. Die analytische Nutzung der Molekül-absorptionsspektrometrie zur Bestimmung von Halogenen basiert auf der Bildung insitu-generierter zweiatomiger Moleküle (AlCl, GaF). Die entstehenden Molekülspektren werden im Echelle-Spektrometer aufgespalten und mittels CCD-Array detektiert, was eine sehr empfindliche Messung und präzise Quantifizierung ermöglicht.
Within the Working Group on Inorganic Analysis (IAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) international key comparisons and pilot studies related to inorganic analysis are carried to ensure consistency in this field at the highest level. Some of these comparisons deal directly with the preparation and characterization of monoelemental solutions or with topics, closely related. The importance of monoelemental solutions lies in the fact that almost every measurement in inorganic analysis relies on the comparison with either a reference material, or references in form of solutions, usually (mono)elemental solutions. All quantitative measurement approaches, e.g. isotope dilution or standard addition, need an accurate reference solution made from a well characterized reference material, prepared under full gravimetric control. These primary (monoelemental) solutions do not only serve as arbitrary references/calibration solutions, but they also link up measurement results to the International System of units (SI), this way establishing the so-called metrological traceability to a measurement unit of the SI. Without such solutions on the highest possible level of accuracy and with the smallest possible associated uncertainties (for e.g. element content and/or impurities), an analysis itself can never be as good as it could be with appropriate reference solutions. This article highlights select key comparisons and pilot studies dealing with monoelemental solution related topics within the IAWG from the foundation of CCQM – 25 years ago – up to latest achievements in the field of inorganic analysis.
Chemical companies must find new paths to successfully survive in a changing environment. The potential of digital technologies belongs to these. Flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short down-times between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds.
Therefore, fully automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. The advances of a fully automated NMR sensor were exploited, using a given pharmaceutical lithiation reaction as an example process within a modular pilot plant. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as , e.g., explosion safety, field communication, and robust evaluation of sensor data. It was thereof used for direct loop advanced process control and real-time optimization of the process. NMR appeared as preeminent online analytical tool and allowed using a modular data analysis tool, which even served as reliable reference method for further PAT applications.
In future, such fully integrated and intelligently interconnecting “smart” systems and processes can speed up the high-quality production of specialty chemicals and pharmaceuticals.
Regardless of its ban in agricultural use, the triazine derivative terbutryn is still used as a biocide against biofouling in building materials, such as façade colors and roof tiles. From there, it is washed off and may contaminate soil and surface waters, where it shows ecotoxicological behavior. For understanding of these leaching processes, analytical methods that can detect terbutryn in traces are necessary. In contrast to separation methods (Gas (GC) or liquid chromatography (LC)) coupled to mass spectrometry (MS), enzyme immunoassays (EIAs) have proven to be adequate tools for environmental monitoring. Compared to GC-or LC-MS, they are cheap, require only limited time and experimental expertise and enable high throughput. For quantification of terbutryn, EIAs have been established, with a limit of detection (LOD) of 50 ng L-1. For leaching experiments however, a lower LOD would be advantageous.
For detection of terbutryn we developed a direct competitive ELISA based on a monoclonal antibody: Terbutryn and an enzyme-terbutryn conjugate (“tracer”) compete for the binding sites of the immobilized antibody. The bound tracer converts a colourless substrate into a blue-coloured product, which can be detected via spectrophotometry. For quantification of terbutryn, a sigmoidal calibration curve is used. For establishing of the EIA, a new tracer based on a terbutryn surrogate (“hapten”) was synthesized. After optimization of the experimental conditions, the immunoassay exhibited a more than ten-fold increased sensitivity (LOD: 3 ng L-1), high stability against sample compounds (Ca2+, NaCl) and lower cross-reactivities against structurally related compounds, than reported before. Analysis of spiked samples was possible with high precision (inter-assay CV: < 10 %) and accuracy (recoveries from spiked samples: 89 % ± 10%). We therefore propose it as quick and reliable method for leaching studies of terbutryn out of building materials.
We present the optical sensing of phthalate Esters (PAEs), a group of endocrine-disrupting chemicals. The sensing takes place as changes in the fluorescence emission intensity of aminopyrene covalently bound to the organic ligands of the metal−organic framework compound ZIF-8. In the presence of PAEs, a quenching of the fluorescence emission is observed. We evaluated strategies to engineer colloidal size distribution of the sensing particles to optimize the sensory response to PAEs. A thorough characterization of the modified ZIF-8 nanoparticles included powder X-ray diffractometry, transmission electron microscopy, high-performance liquid chromatography, and photophysical characterization. The presented capability of the fluorophore-functionalized ZIF-8 to sense PAEs complements established methods such as chromatography-based procedures, which cannot be used on-site and paves the way for future developments such as hand-held quick sensing devices.
The formation of diffusion layers on Zn layers deposited on Al substrates is mainly used to prevent corrosion effects. Evaluation of the influence exerted by different coating methodologies and heat treatments on the formation of these diffusion layers is of great interest for the aluminium industry. Particularly, multi-elemental in-depth distributions of major, minor and trace elements in Zn-coatings is highly demanded before and after heat treatments. A fast characterization of these materials require a direct solid analytical technique able to provide high sensitivity and high depth resolution. For this purpose, an improved analytical method based on the use of pulsed glow discharge sector field mass spectrometry (pulsed-GD-SFMS) is investigated. Glow discharge operating parameters (e.g. pulse duration, pulse frequency), glow discharge source design (e.g. flow tube lengths), and SFMS mass spectra acquisition conditions (e.g. integration time) are evaluated to achieve low sputtering rates, high mass spectra acquisition rates and improved depth resolution. At the optimize conditions Zn coatings deposited by arc-spray and electrodeposition are analysed before and after heat treatments to evaluate the diffusion of different key elements. Moreover, results are validated using femtosecond laser ablation (fs-LA)-ICP-MS, which provides additional information about the heterogeneous distribution of some elements in the Zn coatings.
Die metallischen Verunreinigungen in Metallen lassen sich mittels hochauflösender Massenspektrometer relativ einfach ermitteln. Die Glimmentladungs-Massenspektrometrie (GD-MS) stellt hierfür eine schnelle Multielementmethode dar. Aufgrund ihrer höheren Anregungs- und Ionisationsenergien ist die Bestimmung von Nichtmetallen eine weit größere Herausforderung. Außerdem fehlt es an für die direkte Feststofftechnik notwendigen Kalibrierstandards z.B. in Form zertifizierter Referenzmaterialien. Für die quantitative Bestimmung von Verunreinigungen wurden mit Standards dotierte Pulverpresslinge und dotierte, gesinterte Materialien auf ihre Eignung als Kalibrierstandards für die GD-MS untersucht. Dabei kamen unterschiedliche Plasmabedingungen (gepulster/ kontinuierlicher Betrieb; verschiedene Plasmagase) zum Einsatz. Ein Überblick über analytische Kenngrößen und Grenzen der verwendeten Kalibrierstrategien wird gegeben. Zur Validierung des Verfahrens wurde die hochauflösende Continuum Source Absorptionsspektrometrie (HR-CS-MAAS) verwendet. Die analytische Nutzung der Molekül-absorptionsspektrometrie zur Bestimmung von Halogenen basiert auf der Bildung insitu-generierter zweiatomiger Moleküle (AlCl, GaF). Die entstehenden Molekülspektren werden im Echelle-Spektrometer aufgespalten und mittels CCD-Array detektiert, was eine sehr empfindliche Messung und präzise Quantifizierung ermöglicht.
Ergot alkaloids play a significant role in human history for more than 1000 years and are part of the most common contaminants of food and feed worldwide. Their high toxicity against humans and livestock even at low concentrations causes a high demand for quick and reliable analytics even though no European limits for ergot alkaloids have been determined yet. Currently the most common methods for the quantitation of the six major ergot alkaloids and their corresponding stereoisomers are HPLC based, using either fluorescence or mass spectrometric detection. Whereas these conventional detection methods measure each compound individually, a novel approach is to transfer all ergot alkaloids to one basic structure, which could be measured as a sum parameter.
Since all ergots contain a lysergic acid amide moiety and a differing peptide component, cleaving the molecule into a simple lysergic acid derivative, which could be quantified via either HPLC-FLD or MS/MS, is intended. To clean up the cleavage reaction mixture molecularly imprinted polymers (MIPs) are a simple and effective way to separate the desired structure. Due to the selectivity of MIPs, an improved matrix separation is expected, which results in fewer interferences in the FLD and the possibility to measure samples with more complex matrices. When fully developed, the novel method could overcome some major drawbacks of the conventional detection methods. Higher throughput and the need for less well-trained personnel are just two advantages, that should lead to a quick and cheap quantitation of ergot alkaloids. First results of this project will be presented, funded by the German ZIM program (Zentrales Innovationsprogramm Mittelstand) of the Federal Ministry for Economic Affairs and Energy.
Ergot alkaloids play a significant role in human history for more than 1000 years and are part of the most common contaminants of food and feed worldwide. Their high toxicity against humans and livestock even at low concentrations causes a high demand for quick and reliable analytics even though no European limits for ergot alkaloids have been determined yet. Currently the most common methods for the quantitation of the six major ergot alkaloids and their corresponding stereoisomers are HPLC based, using either fluorescence or mass spectrometric detection. Whereas these conventional detection methods measure each compound individually, a novel approach is to transfer all ergot alkaloids to one basic structure, which could be measured as a sum parameter.
Since all ergots contain a lysergic acid amide moiety and a differing peptide component, cleaving the molecule into a simple lysergic acid derivative, which could be quantified via either HPLC-FLD or MS/MS, is intended. To clean up the cleavage reaction mixture molecularly imprinted polymers (MIPs) are a simple and effective way to separate the desired structure. Due to the selectivity of MIPs, an improved matrix separation is expected, which results in fewer interferences in the FLD and the possibility to measure samples with more complex matrices. When fully developed, the novel method could overcome some major drawbacks of the conventional detection methods. Higher throughput and the need for less well-trained personnel are just two advantages, that should lead to a quick and cheap quantitation of ergot alkaloids. First results of this project will be presented, funded by the German ZIM program (Zentrales Innovationsprogramm Mittelstand) of the Federal Ministry for Economic Affairs and Energy.
The chemical emissions from products are tested by means of emission test chambers under defined conditions (climate, loading, air change rate). The standard method for the determination of volatile organic compounds (VOC) is the sampling onto Tenax-tubes followed by thermal desorption (TDS) and gas chromatography-mass spectrometry (GC-MS) analysis. The EU-LCI list includes some very volatile organic compounds (VVOC) and some VOC for which there are limitations when using the standard method. For VVOC additional sampling is required using stronger absorbers like Carbotrap or multi-bed adsorption tubes. The analysis of VVOC also requires a different GC oven program and a different column for the separation. For the determination of formaldehyde and other low boiling aldehydes (e.g. acetaldehyde, acetone, propanal, propenal) DNPH-cartridges are used which are extracted with acetonitrile followed by liquid chromatography (HPLC-UV) analysis. The derivatisation of propenal and other unsaturated aldehydes (e.g. 2-butenal) with DNPH might lead to lower findings due to incomplete derivatization and forming of by-products. For a better quantification of acetic acid the use of ion chromatography (IC) is recommended because the analysis of acetic acid with the standard method (TDS) leads to lower findings due to break through during sampling. The use of ion chromatography for the analysis of organic acids requires a third sampling technique. The acids are adsorbed onto silica-gel and extracted with water.
Chlorination procedures are commonly applied in swimming pool water and wastewater treatment, yet also in food, pharmaceutical, and paper production. The amount of chlorine in water needs to be strictly controlled to ensure efficient killing of pathogens but avoid the induction of negative health effects. Miniaturized microfluidic fluorescence sensors are an appealing approach here when aiming at online or at-site measurements. Two meso-enamine-substituted boron dipyrromethene (BODIPY) dyes were found to exhibit favorable indication properties, their reaction with hypochlorite leading to strong fluorescence enhancement. Real-time assays became possible after integration of these fluorescent probes with designed two-dimensional (2D) and three-dimensional (3D) microfluidic chips, incorporating a passive sinusoidal mixer and a microhydrocyclone, respectively. A comparison of the two microfluidic systems, including their abilities to prevent accumulation or circulation of microbubbles produced by the chemical indication reaction, showed excellent fluidic behavior for the microhydrocyclone-based device. After coupling to a miniaturized optical reader for fluorescence detection, the 2D microfluidic system showed a promising detection range of 0.04−0.5 mg L−1 while still being prone to bubble-induced fluctuations and suffering from considerably low signal gain. The microhydrocyclone-based system was distinctly more robust against gas bubbles, showed a higher signal gain, and allowed us to halve the limit of detection to 0.02 mg L−1. The use of the 3D system to quantify the chlorine content of swimming pool water samples for sensitive and quantitative chlorine monitoring was demonstrated.
Besides conventional scanning X-ray fluorescence imaging at synchrotron sources, full-field X-ray fluorescence (FF-XRF) imaging techniques that do not implicitly require spatial scanning of the sample have become available. FF-XRF has become achievable thanks to the development of a new type of energy dispersive CCD-based 2D detector, also referred to as a 'color X-ray camera (CXC)' or 'SLcam'. We report on different imaging schemes for biological samples using FF-XRF imaging: (a) 2D 'zoom' imaging with pinhole optics using the 'camera obscura' principle; (b) 2D 'fixed magnification' imaging using magnifying polycapillary optics; and (c) 3D-FF-XRF imaging using an X-ray sheet beam or computed tomography (CT). The different FF-XRF imaging modes are illustrated using the crustacean Daphnia magna, a model organism for investigating the effects of metals on organism/ecosystem health, and foraminifera, a class of amoeboid protist. Detailed analytical characterization of the set-up is performed through analyzing various reference materials in order to determine limits of detection (LODs) and sensitivities. Experiments were performed using the BAMline at the BESSY synchrotron (Berlin, Germany) and using the P06 Hard X-ray Microprobe at the PETRAIII synchrotron (Hamburg, Germany).
Accelerating chemical process development and manufacturing along with quick adaption to changing customer needs means consequent transformation of former batch to continuous (modular) manufacturing processes. These are justified by an improved process control through smaller volumes, better heat transfer, and faster dynamics of the examined reaction systems.
As an example, for such modular process units we present the design and validation of an integrated nuclear magnetic resonance (NMR) micro mixer tailor‐made for a desired chemical reaction based on computational modelling. The micro mixer represents an integrated modular production unit as an example for the most important class of continuous reactors. The quantitative online NMR sensor represents a smart process analytical field device providing rapid and non‐invasive chemical composition information without need for calibration. We describe the custom design through computational fluid dynamics (CFD) for the demands of the NMR sensor as well as for the given reaction conditions. The system was validated with an esterification reaction as an example for a chemical reaction process.
Systems utilizing such an online NMR analyser benefits through short development and set‐up times based on “modular” spectral models. Such models can simply be built upon pure component NMR spectra within minutes to a few hours (i.e., assignment of the NMR signals to the components) instead of tedious DoE calibrations runs. We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). The approach was validated for typical industrial reactions, such as hydrogenations or lithiations.
The elemental analysis of seawater is often critical to the understanding of marine chemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdown spectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a great potential for in-situ elemental analysis of seawater. In practice, it is crucial to create a compact, low cost and power saving instrument for the long-term deep-sea observation. A recently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidate as it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHz can provide a considerable throughput for LIBS analysis. However, the DPSS lasers operate at moderate pulse energies, usually less than one mJ, which cannot sustain stable breakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such a μJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. The phase interface and mass flow generated by the near-field ultrasound can greatly reduce the breakdown threshold and enhance element-specific emissions. Meanwhile, the high repetition-rate pulses can also improve the breakdown probability and generate unique emission lines originated from the water molecule. We further demonstrate that the high repetition-rate DPSS laser combined with the Echelle spectrometer can provide effective quantitative analysis for metal elements in bulk water.
High-resolution mass spectrometry, either combined with gas or liquid chromatography (GC/LC-HR-MS), is currently the most powerful analytical option for broad nontargeted small molecule analysis. To transform HR-MS raw data from metabolomics or environmental studies into chemically meaningful data, several computational steps are needed, including peak detection, deconvolution of these peaks into compounds and putative identification of compounds using databases. Each of these steps can cause problems and still requires methodological advancements. Computational compound annotation as one of the steps, however, has proven particularly challenging, mainly due to the chemical diversity of organic analytes. In addition, different annotation approaches are needed for the different platforms used in HR-MS screening. We recently introduced InterpretMSSpectrum as an annotation workflow for GC-HR-MS using atmospheric pressure chemical ionization (APCI). InterpretMSSpectrum locates molecular ion, fragment and adduct peaks, calculates their most likely sum formula combination and graphically summarizes results as an annotated mass spectrum. As a complementary approach for LC-HR-MS, we presented findMAIN, which scores MS1 spectra based on explained intensity, mass accuracy and isotope charge agreement of adducts and related electrospray ionization (ESI) products to determine the neutral mass of unknown compounds. Both approaches were validated against large spectral libraries containing more than 600 compounds, for which correct annotation was achieved in over 80% of the cases. Based on the experiences from this validation, we here compare soft-ionization GC/LC-HR-MS regarding “annotatability” of unknown compounds from a computational perspective. As a main advantage for GC-HR-MS, the relatively uniform ionization behavior of commonly used trimethylsilyl (TMS) derivatives observed under APCI allowed differentiation of molecular ion peaks from in-source fragments based on relatively compact set of rules. By contrast, neutral mass inference in ESI required a more complex evaluation scheme, due to the higher diversity of ionization products observable in ESI. We demonstrate such differences by practical examples of both software packages applied to metabolomics studies and discuss the challenges connected to transferring the approaches to environmental screening.
Im Vortrag werden Anforderungen und Lösungsvorschläge für das Labor der Zukunft diskutiert. Industrie 4.0 bzw. das Labor 4.0 hilft uns, komplexere Prozesse schneller umzusetzen. Entwicklung von Anlagen und Prozessen beginnt im Labor 4.0. Dazu werden offene, nicht proprietäre Schnittstellen und Standards bei Laborgeräten und Feldgeräten dringend benötigt.
Der Vortrag beschreibt den Entwicklungsprozess des Analysenverfahrens TED-GC-MS zur Bestimmung von Mikroplastikgehalten in Umweltproben im Rahmen des BMBF-Projektes MiWa. Die Funktionsweise, die Automatisierung und die Optimierung einzelner Geräteparameter und Leistungsdaten werden gezeigt. Untersuchungen des Einflusses von Probenmatrices werden dargestellt und die Ergebnisse einiger Messkampagnen und Ringversuche vorgestellt, die die Routinefähigkeit des Verfahrens dokumentieren.
Analysis of dynamic systems
(2019)
Monitoring specific information (i.e., physico-chemical properties, chemical reactions, etc.) is the key to chemical process control when looking at dynamic systems, and quantitative online NMR spectroscopy is the method of choice for the investigation and understanding of dynamic multi-component systems. NMR provides rapid and non-invasive information, and due to the inherent linearity between sample concentration and signal intensity, peak areas can be directly used for quantification of multiple components in a mixture (without the need for any further calibration). This is one of the most attractive features of quantitative NMR spectroscopy. With the launch of devices covering magnetic field strengths from 40 to 90 MHz, so called compact or benchtop NMR systems, this analytical method is now reaching a sufficient degree of compactness and operability for an application outside of very specialized laboratories.
Whilst there are also many other tools available to examine various analytical parameters from dynamic processes, such as mass spectrometry, (near) infrared or Raman spectroscopy, each of these tools can only really be used independently. How can we examine and compare all data describing a particular chemical reaction? How can we visualize information rich, specific, or direct methods together with less specific but established analytical methods? And how can we transfer calibration information to the most appropriate process analytical method or method combination? Quantitative NMR spectroscopy (qNMR) has the potential to substitute offline laboratory analysis for calibration purposes by delivering quantitative reference data as an online method.
The workshop briefly presents the current state of the art of the analysis of dynamic systems by online NMR spectroscopy and analytical data fusion, with the remaining time being used for questions and open discussion with the attendees.
Tempeh is a common food in Indonesia, produced by fungal fermentation of soybeans using Rhizopus sp., as well as Aspergillus oryzae, for inoculation. Analogously, for economic reasons, mixtures of maize and soybeans are used for the production of so-called tempeh-like products. For maize, a contamination with the mycoestrogen zearalenone (ZEN) has been frequently reported. ZEN is a mycotoxin which is known to be metabolized by Rhizopus and Aspergillus species. Consequently, this study focused on the ZEN transformation during tempeh fermentation. Five fungal strains of the genera Rhizopus and Aspergillus, isolated from fresh Indonesian tempeh and authentic Indonesian inocula, were utilized for tempeh manufacturing from a maize/soybean mixture (30:70) at laboratory-scale. Furthermore, comparable tempeh-like products obtained from Indonesian markets were analyzed. Results from the HPLC-MS/MS analyses show that ZEN is intensely transformed into its metabolites alpha-zearalenol (alpha-ZEL), ZEN-14-sulfate, alpha-ZEL-sulfate, ZEN-14-glucoside, and ZEN-16-glucoside in tempeh production. alpha-ZEL, being significantly more toxic than ZEN, was the main metabolite in most of the Rhizopus incubations, while in Aspergillus oryzae fermentations ZEN-14-sulfate was predominantly formed. Additionally, two of the 14 authentic samples were contaminated with ZEN, alpha-ZEL and ZEN-14-sulfate, and in two further samples, ZEN and alpha-ZEL, were determined. Consequently, tempeh fermentation of ZEN-contaminated maize/soybean mixture may lead to toxification of the food item by formation of the reductive ZEN metabolite, alpha-ZEL, under model as well as authentic conditions.
Die Vorgehensweise bei der Zertifizierung von Referenzmaterialien in der BAM entsprechend den Regeln des ISO-Guide 35 wird an Beispielen beschrieben. Darüber hinaus wird ein umfassender Überblick über Referenzmaterialien zur Analyse der Nichtmetalle Sauerstoff, Wasserstoff, Stickstoff, Kohle und Schwefel gegeben.
Die zunehmenden Nachweise von Kunststoffen in verschiedenen Umweltmedien erfahren in den letzten Jahren weltweit ein zunehmendes wissenschaftliches, gesellschaftliches und politisches Interesse. Besondere Aufmerksamkeit erfahren Kunststoffpartikel von 1-1.000 µm, sogenanntes Mikroplastik. Es wurde mittlerweile in Wasser, Böden, Luft und Biota nachgewiesen. Obwohl die Wirkungen auf die natürlichen Umweltfunktionen noch unklar sind und kontrovers diskutiert werden, ist allein durch die ubiquitäre Präsenz eine systematische Erfassung von Eintragsquellen und Verbleib der Partikel über alle Umweltmedien notwendig, um Maßnahmen zur Reduktion der Einträge zu veranlassen.
Für eine zuverlässige Erfassung sind medienübergreifende Verfahren zu entwickeln, welche die drei analytischen Schritte, Probennahme, Probenaufbereitung und Detektion beinhalten. Die Verfahren adressieren unterschiedliche Zielgruppen, welche verschiedene analytische Informationen fordern. Für die akademische Bewertung werden Verfahren mit hohem analytischen Aufwand favorisiert, welche möglichst detaillierte Information über Partikelsorte, -größe, -zahl und -oberflächenbeschaffenheit geben. Im Gegensatz dazu, fordern Anwender aus der Praxis schnelle und einfache Monitoring Verfahren, welche die Bestimmung eines Massengehaltes, bzw. eines Grenzwertes zulassen. Allen ist gemeinsam, dass ein hoher interdisziplinärer Anspruch besteht, der sowohl technische Voraussetzungen zur repräsentativen Probennahme und die Limitationen von Detektionsverfahren berücksichtigt, als auch die Fachkompetenz von Biologen, Umweltwissenschaften, Analytiker und Polymerwissenschaftler einschließt.
Verfahren zum Mikroplastiknachweis müssen auch verschieden Proben mit sehr unterschiedlichen Gehalten an natürlicher Matrix gerecht werden. So müssen allein für Wasser Verfahren entwickelt werden, die Mikroplastik verschiedener Form (sphärische Partikel, komplexe Bruchstücke, Fasern) aus Medien mit sehr variablen Partikelanteil (u.a. Trinkwasser, Oberflächenwasser, Abwasser) repräsentativ erfassen, sowie schnell und kostengünstig sind – einschließlich der notwendigen Probenaufbereitung. Die jeweiligen Detektionsverfahren müssen z.B. einzelne Partikel oder integrale Gehalte über drei Dekadenklassen für thermoplastische und insbesondere auch elastomere Partikelsorten erfassen können.
There have been an increasing number of publications on flow chemistry applications of compact NMR. Despite this, there is so far no comprehensive workflow for the technical design of flow cells. Here, we present an approach that is suitable for the design of an NMR flow cell with an integrated static mixing unit. This design moves the mixing of reactants to the active NMR detection region within the NMR instrument, presenting a feature that analyses chemical reactions faster (5–120 s region) than other common setups. During the design phase, the targeted mixing homogeneity of the components was evaluated for different types of mixing units based on CFD simulation. Subsequently, the flow cell was additively manufactured from ceramic material and metal tubing. Within the targeted working mass flow range, excellent mixing properties as well as narrow line widths were confirmed in validation experiments, comparable to common glass tubes.
Arraying of single cells for mass spectrometric analysis is a considerable bioanalytical challenge. In this study, we employ a novel single cell arraying technology for quantitative analysis and isotopic fingerprinting by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS). The single cell arraying approach is based on a piezo-acoustic microarrayer with software for automated optical detection of cells within the piezo dispense capillary (PDC) prior to arraying. Using optimized parameters, single cell occupancy of >99%, high throughput (up to 550 cells per hour), and a high cell recovery of >66% is achieved. LA-ICP-TOF-MS is employed to detect naturally occurring isotopes in the whole mass range as fingerprints of individual cells. Moreover, precise quantitative determination of metal-containing cell dyes is possible down to contents of ∼100 ag using calibration standards which were produced using the same arrayer.
In the last decades, significant efforts have been made to investigate possible cytotoxic effects of metallic nanoparticles (NPs). Methodologies enabling precise information regarding uptake and intracellular distribution of NPs at the single cell level remain to be established. Mass cytometry (MC) has been developed for high-dimensional single cell analyses and is a promising tool to quantify NP−cell interactions. Here, we aim to establish a new MC-based quantification procedure to receive absolute numbers of NPs per single cell by using a calibration that considers the specific transmission efficiency (TE) of suspended NPs. The current MC-quantification strategy accept TE values of complementary metal solutions. In this study, we demonstrate the different transmission behavior of 50 nm silver NPs (AgNP) and silver nitrate solution. We have used identical AgNPs for calibration as for in vitro-differentiated macrophages (THP-1 cell line) in a time- and dose-dependent manner. Our quantification relies on silver intensities measuring AgNPs in the same detection mode as the cells. Results were comparable with the TE quantification strategy using AgNPs but differed when using ionic silver. Furthermore, intact and digested cell aliquots were measured to investigate the impact of MC sample processing on the amount of AgNPs/cell. Taken together, we have provided a MC-specific calibration procedure to precisely calculate absolute numbers of NPs per single cell. Combined with its unique feature of multiplexing up to 50 parameters, MC provides much more information on the single cell level than single cell-inductively coupled plasma mass spectrometry (SC-ICP-MS) and, therefore, offers new opportunities in nanotoxicology.
In the recent decade, metal pyrithione complexes have become important biocides for antifouling purposes in shipping. The analysis of metal pyrithione complexes and their degradation products/species in environmental samples is challenging because they exhibit fast UV degradation, transmetalation, and ligand substitution and are known to be prone to spontaneous species transformation within a chromatographic system. The environmental properties of the pyrithione species, e.g., toxicity to target and non-target organisms, are differing strongly, and it is therefore inevitable to identify as well as quantify all species separately. To cope with the separation of metal pyrithione species with minimum species transformation during analysis, a capillary electrophoresis (CE)–based method was developed. The hyphenation of CE with selective electrospray ionization- and inductively coupled plasma–mass spectrometry (ESI-, ICP-MS) provided complementary molecular and elemental information for the identification and quantification of pyrithione species. To study speciation of pyrithiones, a leaching experiment of several commercial antifouling paints containing zinc pyrithione in ultrapure and river water was conducted. Only the two species pyrithione (HPT) and dipyrithione ((PT)2) were found in the leaching media, in concentrations between 0.086 and 2.4 μM (HPT) and between 0.062 and 0.59 μM ((PT)2), depending on the paint and leaching medium. The limits of detection were 20 nM (HPT) and 10 nM ((PT)2). The results show that complementary CE-MS is a suitable tool for mechanistical studies concerning species transformation (e.g., degradation) and the identification of target species of metal pyrithione complexes in real surface water matrices, laying the ground for future environmental studies.
In X-ray fluorescence (XRF), a sample is excited with X-rays, and the resulting characteristic radiation is detected to detect elements quantitatively and qualitatively. Quantification is traditionally done in several steps:
1. Normalization of the data
2. Determination of the existing elements
3. Fit of the measured spectrum
4. Calculation of concentrations with fundamental parameters / MC simulations / standard based
The problem with standard based procedures is the availability of corresponding standards. The problem with the calculations is that the measured intensities for XRF measurements are matrix-dependent. Calculations must, therefore, be performed iteratively (= time consuming) in order to determine the chemical composition.
First experiments with gold samples have shown the feasibility of machine learning based quantification in principle. A large number of compositions were simulated (> 10000) and analyzed with a deep learning network. For first experiments, an ANN (Artificial Neural Network) with 3 hidden layers and 33x33x33 neurons was used. This network learned the mapping of spectra to concentrations using supervised learning by multidimensional regression. The input layer was formed by the normalized spectrum, and the output layer directly yielded the searched values. The applicability for real samples was shown by measurements on certified reference materials.
Bundling analytical capacities to understand phase formation in recycling of functional materials
(2019)
Transitioning from combustion engine-driven transportation to e-mobility demands a paradigm shift – from a system geared to maximize energy efficiency (i.e. fuel consumption) to a system that may be constrained by the availability of high technology (critical) metals required for electrical energy storage systems and drives. In the wake of these developments efforts in securing new resources of these metals from recycling of end-of-life products are increasing steadily.
Recycling of Li-Ion batteries has recently been evaluated. The results pinpoint to a critical need for understanding slag Formation and its dependence on metal components like Mn under extreme conditions. This will allow researchers to predict optimal Operation setting and to react quickly to changing market demands (which may be Li or Co at one point but may also shift to Ni or rare earth elements (REE)). The long-term goal is to control the formation of specific phases in slags allowing for a Maximum yield of elements of interest and optimal recovery in the separation processes that follows. The combination of data on the physical micro structure and local chemistry of the multi-Phase products during and after processing will help to understand and derive thermodynamic and kinetic data on its formation.
In this paper we are giving an overview on the analytical challenges and approaches to provide robust data on local element concentration and species (especially Mn which is a common component of next generation Li-ion batteries cathodes), spanning the dimensions from the nanometer scale to the bulk material. The complementary interactions of X-rays and electrons make them ideal probes to collect Interface and “in-depth” information. Before- and -after studies as well as in situ structural changes and Phase (trans)formation, changes in elemental and elemental species (e.g. oxidation state) distribution may be tracked by X-ray diffraction (XRD), X-ray fluorescence microscopy and X-ray Absorption spectroscopy. The application of such advanced analytical tools will not only provide essential clues during early lab-based experiments towards the development of new recycling technologies, but may also be deployed for on-line and in-line monitoring of industrial processes.
Synchrotron radiation sources with their unique properties in terms of intensity, polarization and adjustability offer a wide range of possibilities in materials research. A basic introduction about the creation and special properties of synchrotron radiation will be given. Examples of current work at BAMline, the high-energy measuring facility of the Federal Institute for Materials Research and Testing at the synchrotron BESSY, are used to illustrate the possibilities and limitations of existing measuring methods. It will be shown how the formation of corrosion layers can be tracked, how the abrasion of implants leads to the introduction of heavy metals into the surrounding bone matrix and how the detection of smallest impurities in gold is possible by optimizing the measuring conditions. Finally, an outlook at the hardware and software developments to be expected in the coming years is given.
Tandem mass spectrometry represents an important analytical tool to unravel molecular structures and to study the gas-phase behavior of organic molecules. Besides commonly used methods like collision-induced dissociation and electron capture or transfer dissociation, new ultraviolet light–based techniques have the potential to synergistically add to the activation methods. Here, we present a new simple, yet robust, experimental design for polychromatic activation of trapped ions using the 115–160 nm output of a commercially available deuterium lamp. The resulting continuous dissociative excitation with photons of a wide energy range from 7.7 to 10.8 eV is studied for a comprehensive set of analyte classes in both positive and negative ion modes. While being simple, affordable, compact, and of low maintenance, the new setup initiates fragmentation of most precursor ions via their known dissociation pathways. Additionally, some new fragmentation patterns were discovered. Especially, electron loss and electron capture reactions with subsequent fragmentations were observed. For oligonucleotides, peptides, carbohydrates, and organic dyes, in comparison to collision-induced dissociation, a significantly wider fragment distribution was obtained, resulting in an information increase. Since the individual photons carry enough energy to post-ionize the nascent fragments, a permanent vacuum ultraviolet light exposure inside the ion trap potentially goes along with a general increase in detection capability.
A fast and simple method for sulfur quantification in crude oils was developed by using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). For this, heavy crude oil samples were prepared as microemulsion (shake) and injected into a graphite furnace (shut). Finally, the concentration of sulfur was determined by monitoring in situ the transient molecular spectrum of GeS at wavelength 295.205nm after adding a germanium solution as molecular forming agent (and go). Zirconium dioxide in the form of nanoparticles (45–55nm) was employed as a permanent modifier of the graphite furnace. Calibration was done with an aqueous solution standard of ammonium sulfate, and a characteristic mass (m0) of 7.5ng was achieved. The effectiveness of the proposed method was evaluated analizing, ten heavy crude oil samples with Sulfur amounts ranging between 0.3 and 4.5% as well as two NIST standard reference materials, 1620c and 1622e. Results were compared with those obtained by routine ICP-OES analysis, and no statistical relevant differences were found.
We applied high resolution laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) with cellular spatial resolution for bioimaging of nanoparticles uptaken by fibroblast multicellular spheroids (MCS). This was used to quantitatively investigate interactions of silver nanoparticles (Ag NPs) and the distributions of intrinsic minerals and biologically relevant elements within thin sections of a fibroblast MCS as a three-dimensional in vitro tissue model. We designed matrix-matched calibration standards for this purpose and printed them using a noncontact piezo-driven array spotter with a Ag NP suspension and multielement standards. The limits of detection for Ag, Mg, P, K, Mn, Fe, Co, Cu, and Zn were at the femtogram (fg) level, which is sufficient to investigate intrinsic minerals in thin MCS sections (20 μm thick). After incubation for 48 h, Ag NPs were enriched in the outer rim of the MCS but not detected in the core. The localization of Ag NPs was inhomogeneous in the outer rim, and they were colocalized with a single-cell-like structure visualized by Fe distribution (pixel size of elemental images: 5 × 0.5 μm). The quantitative value for the total mass of Ag NPs in a thin section by the present method agreed with that obtained by ICP-sector field (SF)-MS with a liquid mode after acid digestion.
The knowledge of transformation pathways and identification of transformation products (TPs) of veterinary drugs is important for animal health, food, and environmental matters. The active agent Monensin (MON) belongs to the ionophore antibiotics and is widely used as a veterinary drug against coccidiosis in broiler farming. However, no electrochemically (EC) generated TPs of MON have been described so far. In this study, the online coupling of EC and mass spectrometry (MS) was used for the generation of oxidative TPs. EC-conditions were optimized with respect to working electrode material, solvent, modifier, and potential polarity. Subsequent LC/HRMS (liquid chromatography/high resolution mass spectrometry) and MS/MS experiments were performed to identify the structures of derived TPs by a suspected target analysis. The obtained EC-results were compared to TPs observed in metabolism tests with microsomes and hydrolysis experiments of MON.
Five previously undescribed TPs of MON were identified in our EC/MS based study and one TP, which was already known from literature and found by a microsomal assay, could be confirmed.
Two and three further TPs were found as products in microsomal tests and following hydrolysis, respectively. We found decarboxylation, O-demethylation and acid-catalyzed ring-opening reactions to be the major mechanisms of MON transformation.
The most challenging part in performing a single cell ICP-MS (sc-ICP-MS) approach is the sample preparation, in particular the reduction of the ionic background. This step is, in many cases, time-consuming and required for each sample separately. Furthermore, sc-ICP-MS measurements are mostly carried out "manually", given the fact that present systems are not allowing for an automated change of samples. Thus, within this work, we developed an approach based on a HPLC system coupled on-line with sc-ICP-MS via a set of switching valves as well as an in-line filter for automated cell washing. This set-up enables the ionic background removal as well as analysis of single cells completely automated without any manual sample pretreatment. Our approach was applied for the analysis of the single celled diatom species Cyclotella meneghiniana, a marine diatom species, on the basis of Mg24 and facilitates testing in 11 min per sample, requiring only around 10,000 cells in a volume of 10 µL and approx. 10 mL of a 5% MeOH/95% deionized water (v/v) mixture. Even at extremely saline culturing media concentrations (up to 1000 mg L-1 magnesium) our on-line approach worked sufficiently allowing for distinction of ionic and particulate fractions. Furthermore, a set of diatom samples was analyzed completely automated without the need for changing samples manually. So, utilizing this approach enables analyzing a high quantity of samples in a short time and therefore in future the investigation of ecotoxicological effects is simplified for example in terms of metal accumulation by taking biovariability into account.
We investigated the penetration of silver nanoparticles (Ag NPs) into a three-dimensional in vitro tissue analog using NPs with various sizes and surface coatings, and with different incubation times. A high-Resolution laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) time-of-flight (TOF) instrument was applied for imaging the distributions of elements in thin sample sections (20 μm thick). A fibroblast multicellular spheroid (MCS) was selected as the model system and cultured for more than 8 days to produce a natural barrier formed by the extracellular matrix containing collagen. The MCS was then exposed for up to 48 h to one of four types of Ag NPs (∅ 5 nm citrate coated, ∅ 20 nm citrate coated, ∅ 20 nm polyvinylpyrrolidone coated, and ∅ 50 nm citrate coated). Imaging showed that the penetration pathway was strongly related to steric networks formed by collagen fibrils, and Ag NPs with a hydrodynamic diameter of more than 41 nm were completely trapped in an outer rim of the MCSs even after incubation for 48 h. In addition, we examined the impact of these NPs on essential elements (P, Fe, Cu, and Zn) in
areas of Ag NP accumulation. We observed a linear increase at the sub-femtogram level in the total concentration of Cu (fg per pixel) in samples treated with small or large Ag NPs (∅ 5 nm or ∅ 50 nm) for 48 h.
Today, in scientific events often a certain separation between researchers from laboratories with highly sophisticated equipment and those from less privileged laboratories can be observed. It is not an uncommon situation that results presented at conferences are rubbished or ridiculed because the investigator only used low-end analytical methods.
The assessment of the study is then biased based on the equipment, regardless of the actual quality of the study.