S Qualitätsinfrastruktur
Filtern
Dokumenttyp
- Vortrag (127)
- Zeitschriftenartikel (36)
- Forschungsbericht (25)
- Beitrag zu einem Tagungsband (22)
- Posterpräsentation (7)
- Sonstiges (5)
- Buchkapitel (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (154)
- Deutsch (69)
- Mehrsprachig (2)
- Italienisch (1)
Schlagworte
- Digitalization (30)
- Certification (29)
- Konformitätsbewertung (27)
- COVID-19 (26)
- Conformity assessment (26)
- Quality infrastructure (24)
- Testing (22)
- Digital transformation (21)
- Laboratory (21)
- Qualitätsinfrastruktur (21)
Organisationseinheit der BAM
- S Qualitätsinfrastruktur (226)
- S.2 Digitalisierung der Qualitätsinfrastruktur (126)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (76)
- S.1 Qualität im Prüfwesen (20)
- 1 Analytische Chemie; Referenzmaterialien (14)
- 1.6 Anorganische Referenzmaterialien (9)
- 1.1 Anorganische Spurenanalytik (5)
- 1.3 Instrumentelle Analytik (5)
- P Präsident (5)
- P.0 Präsident und andere (5)
- S.0 Abteilungsleitung und andere (5)
- 1.8 Umweltanalytik (3)
- 7 Bauwerkssicherheit (3)
- 7.0 Abteilungsleitung und andere (3)
- 9 Komponentensicherheit (3)
- 5 Werkstofftechnik (2)
- 5.1 Mikrostruktur Design und Degradation (2)
- VP Vizepräsident (2)
- VP.1 eScience (2)
- 1.2 Biophotonik (1)
- 1.4 Prozessanalytik (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (1)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 6 Materialchemie (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 6.2 Material- und Oberflächentechnologien (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.0 Abteilungsleitung und andere (1)
- 8.5 Röntgenbildgebung (1)
- 9.3 Schweißtechnische Fertigungsverfahren (1)
- 9.4 Integrität von Schweißverbindungen (1)
- 9.5 Tribologie und Verschleißschutz (1)
- 9.6 Additive Fertigung metallischer Komponenten (1)
- PST Präsidiale Stabsstelle (1)
Paper des Monats
- ja (1)
In this work, we employed glow discharge optical emission spectrometry (GD-OES) depth profiling as a fast and semi-quantitative method to investigate the aluminum (Al) current collector degradation in commercial lithium cobalt oxide (LCO) pouch cells with no Al2O3 pretreatment. After battery aging, a heterogeneous deposit was found on the surface of the cathode. Gray hotspot areas within an extensive pale white region were formed. Consistent with energy dispersive X-ray (EDX) analysis of micro-cross sections milled via targeted focused ion beam (FIB), an Al-containing layer of approximately 3 µm can be observed using GD-OES. We attribute one main cause of this layer is the degradation of the Al current collector. The nonuniform growth of this layer was investigated by performing GD-OES depth profiling at different in-plane positions. We found that the gray area has a higher mass concentration of Al, probably in metallic form, whereas the white area was probably covered more homogeneously with Al2O3, resulting from the inhomogeneous distribution of the pitting positions on the current collector. Compared to FIB-EDX, GD-OES enables a faster and more convenient depth profile analysis, which allows the more productive characterization of lithium-ion batteries (LIBs), and consequently benefits the development of preferable battery materials.
Various microlevel circular economy indicators for assessing sustainability and, partly, additional sustainability characteristics have been developed, but an integrated solution considering the environmental, social, and economic pillars remains a research gap. Method: Based on a multimethod approach, including surveys and the analysis of existing sustainability assessment methodologies and standards, this paper proposes a concept for a multidimensional circular economy indicator tailored to public procurers. It relies on attractive existing building blocks including: the ecological scarcity method, European and international sustainability standards and indicators,and the STAR-ProBio-IAT concept. Results: This article presents the concept of the composite indicator Triple-C, consisting of 20 elements and aimed at facilitating sustainable circular public procurement. It is intended to be incorporated into software that facilitates sustainable product decisions among public procurers in Germany. Conclusions: We propose a generic indicator concept covering all three (environmental, social, and economic) sustainability pillars. More research and additional standards are needed to develop the Triple-C concept further into product-specific applications.
An alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry. For isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions, ranging from 0.06 to 0.99 mol mol–1, previously determined by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS). The calibration ML model was validated with two certified reference materials (LSVEC and IRMM-016). The procedure was applied toward the isotope amount ratio determination of a set of stock chemicals (Li2CO3, LiNO3, LiCl, and LiOH) and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. The results of these determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9 to 6.2‰. This precision was sufficient to resolve naturally occurring variations, as demonstrated for samples ranging from approximately −3 to +15‰. To assess its suitability to technical applications, the NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification. The results obtained were metrologically compatible with each other.
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry.
Seit September 2015 gelten für neue Heizgeräte EU-weit einheitliche Mindeststandards: Heizkessel müssen mindestens den Standard der Brennwerttechnik erreichen (ausgenommen sind B1-Gasetagenheizungen für Mehrfachbelegung). Wird ein alter Wärmeerzeuger ausgetauscht, muss daher stets der Schornstein für die Abgasabführung im Überdruck geeignet sein und gegen Kondensat ertüchtigt werden, also feuchtebeständig sein. Handelt es sich um eine mehrfach belegte Abgasanlage der Arten C4, C8 oder B3, sind alle am Schornsteinstrang angeschlossenen Gasgeräte betroffen. In einem Expertengremium des DVGW wurden Handlungsempfehlungen erarbeitet. Einige Lösungsansätze vermeiden einen sofortigen Austausch aller Geräte an einem gemeinsamen Schornsteinstrang.
The Federal Institute for Materials Research and Testing (BAM) has developed a load-based test method (compensation method) to determine the energy efficency of heat pumps and air conditioners. The method allows for testing with unfixed compressor speed and active control of the unit. Thus, at low part loads the unit under test is allowed to cycle on-off, when the frequency of the compressor drops below its minimum threshold. Therefore, the associated efficiency losses are directly measured and correction calculations as for the current steady state tests become obsolete. In addition, the testing can be performed without the support of the manufacturer by market surveillance authorities, for instance, since no frequency and expansion valve settings are required. To prove that the compensation method is repeatable and reproducible three round robin tests have been organised by BAM.
Current developments in PT
(2021)
COMAR, where do you go?
(2018)
Currently BAM is making efforts to recode COMAR, the database for CRMs and reshape its profile as a database intended for qualitatively top-of-the-market CRMs. These efforts are highlighted and placed into the broad perspective of the international RM markets. A link to EPTIS, the database for PT schemes as a blueprint for the recoding is provided.