Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (80)
- Zeitschriftenartikel (51)
- Posterpräsentation (46)
- Vortrag (33)
- Beitrag zu einem Sammelband (8)
- Forschungsbericht (4)
- Sonstiges (2)
- Dissertation (1)
Sprache
- Englisch (152)
- Deutsch (70)
- Mehrsprachig (2)
- Polnisch (1)
Schlagworte
- Structural health monitoring (17)
- RFID sensors (14)
- Gas storage areas (12)
- Membrane-based gas sensing (12)
- Subsurface monitoring (12)
- Monitoring (11)
- Mobile Robot Olfaction (10)
- Nano aerial robot (10)
- Smart structures (10)
- Drop test (9)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (68)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (68)
- 1 Analytische Chemie; Referenzmaterialien (9)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (9)
- 1.9 Chemische und optische Sensorik (7)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 6 Materialchemie (2)
- 6.7 Materialsynthese und Design (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (33)
Nanocomposites of bisphenol A polycarbonate with 2, 4, 6, and 15 wt% multiwall carbon nanotubes (MWNT) and their use in fire retardancy are investigated. Their thermal behavior and pyrolysis are characterized using thermogravimetry, differential scanning calorimeter, oscillatory shear rheology, and dynamic mechanical analysis. The flammability is addressed using LOI and UL 94; the fire behavior, with a cone calorimeter using different irradiation. With increasing MWNT content the storage modulus is increased (10-20%) and melt viscosity increases by several orders of magnitude, particularly for low shear rates. The melt flow, dripping, and deformation during fire are hindered, which influences UL 94 and cone calorimeter results. The peak heat release rate is reduced up to 40-50% due to an improved barrier for small amounts (2 wt%) of MWNT and for low irradiation, whereas the effect is reduced for increasing irradiation and nearly vanishes for increasing filling. Adjuvant but also deleterious mechanisms result in the complex dependency on the MWNT content. Significant flame retardancy effects are specific and limited to only some fire properties. This study allows the materials' potential for implementation in different fire scenarios and tests to be assessed and provides insight into active mechanisms.
Barrier formation and increasing the melt viscosity are addressed as the two main general fire retardancy mechanisms of polymer nanocomposites. They result in specific impacts on fire properties that consequentially cause varying flame retardancy efficiency in different fire tests. The barrier formation retards mainly flame spread (peak of heat release rate) in developing fires, but does not reduce fire load (total heat evolved), ignitability or flammability (limiting oxygen index, UL 94). Furthermore, this flame retardancy effect increases with increasing irradiation and vanishes with decreasing irradiation. The increased melt viscosity prevents dripping, which is beneficial or disadvantageous depending on the fire test used. In some test, it become the dominant influence, transforming self-extinguishing samples into flammable materials or causing wicking. Advantages and the limits are sketched comprehensively for exploiting the main general fire retardancy mechanisms of polymer nanocomposites. It is concluded that barrier formation and changing the melt viscosity in nanocomposites are not sufficient for most applications, but must be accompanied by additional mechanisms in special systems or in combination with other flame retardants.
A method was developed to assess the heat insulation performance of intumescent coatings. The method consists of temperature measurements using the bench-scaled experimental set-up of a cone calorimeter and finite difference simulation to calculate the effective thermal conductivity dependent on time/temperature. This simulation procedure was also adapted to the small scale test furnace, in which the standard time-temperature curve is applied to a larger sample and thus which provides results relevant for approval. Investigations on temperature and calculated effective thermal conduction were performed on intumescent coatings in both experimental set-ups using various coating thicknesses. The results correspond to each other as well as showing the limits of transferability between both fire tests. It is shown that bench-scaled cone calorimeter tests are a valuable tool for assessing and predicting the performance of intumescent coatings in larger tests relevant for approval. The correlation fails for processes at surface temperatures above 750°C, which are not reached in the cone calorimeter, but are attained in the small scale furnace set-up.
Implementation and validation of robot-enabled embedded sensors for structural health monitoring
(2024)
In the past decades, structural health monitoring (SHM) has matured into a viable supplement to regular inspections, facilitating the execution of repair and maintenance work in the early stages of structural damage. With the advent of wireless technologies and advancements in information and communication technologies, civil infrastructure has been increasingly instrumented with wireless sensor nodes to record, analyze, and communicate data relevant to SHM. A promising method for SHM is to embed sensors directly into concrete for recording SHM data from inside structural elements. In this paper, a sensor system for embedment into concrete is proposed, able to assess SHM data recorded from concrete. Power is supplied to the sensors on-demand by quadruped robots, which also collect the SHM data via radio-frequency identification (RFID), providing an automated and efficient SHM process. In laboratory experiments, the capability of the sensor system of automatically collecting the SHM data using quadruped robots is validated. In summary, the integration of RFID technology and robot-based inspection presented in this study demonstrates a vital approach to evolve current SHM practices towards more digitalized and automated SHM.