Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (80)
- Zeitschriftenartikel (51)
- Posterpräsentation (46)
- Vortrag (33)
- Beitrag zu einem Sammelband (8)
- Forschungsbericht (4)
- Sonstiges (2)
- Dissertation (1)
Sprache
- Englisch (152)
- Deutsch (70)
- Mehrsprachig (2)
- Polnisch (1)
Schlagworte
- Structural health monitoring (17)
- RFID sensors (14)
- Gas storage areas (12)
- Membrane-based gas sensing (12)
- Subsurface monitoring (12)
- Monitoring (11)
- Mobile Robot Olfaction (10)
- Nano aerial robot (10)
- Smart structures (10)
- Drop test (9)
- Sensors in concrete (9)
- Gas sensors (8)
- Gas source localization (8)
- Swarm (8)
- Passive RFID (7)
- Autonomous micro UAV (6)
- Distributed linear sensor (6)
- Electronic nose (6)
- Embedded sensors (6)
- Gas sensing (6)
- Mikrodrohne (6)
- Tomographic reconstruction of gas plumes (6)
- Fluorescence (5)
- Funksensorik (5)
- Hopkinson bar (5)
- Localization of gas sources (5)
- Mobile robot olfaction (5)
- Nanocomposites (5)
- Quadrocopter (5)
- Sensornetzwerk (5)
- Strukturüberwachung (5)
- UAV (5)
- UAV-REGAS (5)
- Wireless sensors (5)
- Air quality monitoring (4)
- Chemical sensing (4)
- Cone Calorimeter (4)
- Distributed sensor (4)
- Energy harvesting (4)
- Environmental monitoring (4)
- Fire retardancy (4)
- Hazardous scenarios (4)
- Localization (4)
- Magnetic field (4)
- Mobile sensing system (4)
- RFID (4)
- Schadensfrüherkennung (4)
- Sensor requirements (4)
- TDLAS (4)
- Transmission characteristics (4)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS) (4)
- VOC (4)
- Aerial robot (3)
- Artificial potential field (3)
- Behälter (3)
- Chemical and wind sensing (3)
- Computed tomography (3)
- Dangerous goods (3)
- Embedded sensor (3)
- Fallprüfung (3)
- Fiber bragg grating (3)
- Gas distribution mapping and gas source localization (3)
- Gasmessung (3)
- Gefahrstoffe (3)
- Hopkinsonstab (3)
- Indoor air quality (3)
- Linear sensor (3)
- LoRaWAN (3)
- Long term monitoring (3)
- Long-term requirements (3)
- Magnetostrictive metal coating (3)
- Multisensor system (3)
- Particle filter (3)
- Plume tracking (3)
- SHM (3)
- Self-diagnostic fiber optical sensor (3)
- Sensor planning (3)
- Sensors (3)
- Smart sensors (3)
- Soil test field (3)
- Trail detection (3)
- Trail following (3)
- Accelerometer (2)
- Aerial robot olfaction (2)
- Air quality (2)
- Ammonia (2)
- Ammonia gas sensor (2)
- Anemometric sensor (2)
- BAM Datenbank Gefahrgut (2)
- Bauwerksüberwachung (2)
- Biologically inspired robots (2)
- CCS (2)
- CO2 (2)
- Carbon capture and storage (2)
- Chemometric techniques (2)
- Concrete (2)
- Condition monitoring (2)
- Cone calorimetry (2)
- Dangerous goods container (2)
- Data fusion (2)
- Data mapping (2)
- Data-fusion (2)
- Diagnosis of concrete components (2)
- Digitalisation (2)
- Early-damage-detection (2)
- Embedded systems (2)
- Emission control (2)
- Environment (2)
- Fiber Bragg grating (2)
- Fiber optical sensing (2)
- Fibre optical sensing (2)
- Field conditions (2)
- Flame retardance (2)
- Flammability (2)
- Gas detection (2)
- Gas dispersion simulation (2)
- Gas distribution modelling (2)
- Gas measurement (2)
- Gas standard generator (2)
- Gas tomography (2)
- Gefahrgut (2)
- High impact shock application (2)
- IMS (2)
- Indoor Localization (2)
- Inertial measurement unit (2)
- Inertial navigation system (2)
- Intumescence (2)
- Intumescent coatings (2)
- Ionenmobilitätsspektrometrie (2)
- LOI (2)
- Lamb-waves (2)
- Leak detection (2)
- Leakage (2)
- Magnetostriction (2)
- Magnetostriktive Beschichtung (2)
- Membrane-based linear gas sensor (2)
- Micro-drone (2)
- Miniaturized sensor device (2)
- Mobile Robot (2)
- Monitoring of CO2 (2)
- Monitoring of dangerous goods (2)
- Multi sensor device (2)
- Multi-sensor system (2)
- Multichannel measuring (2)
- Multichannel measuring system (2)
- NDT Inspection (2)
- Nanocomposite (2)
- Non-destructive evaluation (2)
- Numerical analysis (2)
- Organoclay (2)
- Person tracking (2)
- Piezoresistive accelerometer (2)
- Plume (2)
- Pump control (2)
- Quadrokopter (2)
- RFID based sensors (2)
- RFID-Sensorsysteme (2)
- RFID-based sensors (2)
- Reactive plume tracking (2)
- Red Phosphorus (2)
- Remote gas sensor model (2)
- Robotik (2)
- Safety management (2)
- Sensor (2)
- Sensor calibration and validation (2)
- Sensortechnik (2)
- Setup and Validation (2)
- Spectroscopy (2)
- Sprengstoffspurendetektion (2)
- Standard gas generator (2)
- Strain (2)
- Suche und Lokalisierung von gasförmigen Gefahrstoffquellen (2)
- Temperature characteristics (2)
- Ultrasound (2)
- Umweltmonitoring (2)
- Vielkanalmesssystem (2)
- Voltammetric electronic tongue (2)
- Wasserstoff (2)
- Wastewater (2)
- Wind vector (2)
- Wireless sensor network (WSN) (2)
- 3D-Verformungsmessung (1)
- Actuators (1)
- Air-based (1)
- Airspeed calibration (1)
- Analysis (1)
- Anemometer (1)
- Anemotaxis (1)
- Auto-validation (1)
- Autonomous UAV (1)
- Autonomous robot (1)
- Bauteilintegrierte Sensoren (1)
- Bauteilmonitoring (1)
- Bauwerk (1)
- Berlin Main Station (1)
- Beschleunigungsaufnehmer (1)
- Betonkorrosion (1)
- Bio-inspired (1)
- Bridge components (1)
- Calibration (1)
- Calibration of electrical quantities (1)
- Calibration of force (1)
- Calibration of temperature (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical source localization (1)
- Chemotaxis (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Container (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- DDS (1)
- Data bus (1)
- Data-Mapping (1)
- Datenbus (1)
- Degradation (1)
- Dehnungsmessstreifen (1)
- Differential displacements (1)
- Digital Certificates (1)
- Digitalisierung (1)
- Discrimination of multiple gas sources (1)
- Distributed multifunctional sensor (1)
- Drop (1)
- Drop tests (1)
- Druckgasspeicher (1)
- DuraBASt (1)
- ECD-Aktorschicht (1)
- ETD (1)
- Early damage detection (1)
- Eindringmodul (1)
- Elastoplastic material parameters (1)
- Electronic transport documents (1)
- Embedded (1)
- Embedded system (1)
- Emissionskontrolle (1)
- Emmbedded sensor (1)
- Energiespeicherung (1)
- Environmental analysis (1)
- Epoxide (1)
- Estimation (1)
- Explosionsschutz (1)
- Faser-Bragg Gitter (1)
- Faser-Bragg-Gitter (FBG) (1)
- Faseroptik-Sensoren (1)
- Fiber Bragg gratings (1)
- Fiber optic sensing (1)
- Fibre optical sensing (1)
- Finite element methods (1)
- Fire testing (1)
- Flame retardancy (1)
- Flammschutz (1)
- Fluorescence sensor (1)
- Fluorescence sensors (1)
- Fluorescent sensor (1)
- Fluoreszenz (1)
- Fluoreszenzlöschung (1)
- Fluoreszenzsensoren (1)
- Flying platforms (1)
- Frequency response (1)
- GC-MS (1)
- Gas detector (1)
- Gas distribution mapping (1)
- Gas distribution modeling (1)
- Gas emission (1)
- Gas storage sites (1)
- Gas-sensitive micro-drone (1)
- Gasdetektion (1)
- Gasemission (1)
- Gasfreisetzung (1)
- Gasquellenlokalisierung (1)
- Gassensor (1)
- Gassensorik (1)
- Gasspeicher (1)
- Gefahrenszenarien (1)
- Gefährdungsbeurteilung (1)
- Glasspeicher (1)
- Guided wave (1)
- H2Safety@BAM (1)
- High Impact testing (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Hochdynamische Untersuchungen (1)
- Hopkinson Bar (1)
- Hopkinson pressure bar (1)
- Hopkinson-Stab (1)
- Humidity sensors (1)
- Hydraulic levelling system (1)
- Hydrogen (1)
- Hydrogen technology (1)
- Härtevergleichsplatten (1)
- Impact (1)
- Indentation (1)
- Inertial measurement unit (IMU) (1)
- Instrumentierte Eindringprüfung (1)
- Intumescent coating materials (1)
- Ion mobility spectrometry (1)
- Klebstoffe (1)
- KonSens (1)
- Koordinatenmessung (1)
- Kraftabhängige Funktion (1)
- Ladungssicherung (1)
- Ladungsssicherung (1)
- Lamb wave (1)
- Large scale soil test field (1)
- Laser-based displacement measuring system (1)
- Legged robots (1)
- Luftfrachtsicherheit (1)
- Magneto-optischer Sensor (1)
- Maschinennachgiebigkeit (1)
- Measurement (1)
- Measurement uncertainty (1)
- Mesh routing (1)
- Metal oxide semiconductor (1)
- Methane measuring (1)
- Mg(OH)2 (1)
- Micro UAV (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Mini-UAV (1)
- Mobile Sensorik (1)
- Mobile sensors (1)
- Modeling and simulation (1)
- Moisture (1)
- Moisture measurements (1)
- Monitoring of CO 2 (1)
- Multi-Hop WSN (1)
- Multi-hop (1)
- Multi-sensor (1)
- Multi-sensor device (1)
- Multifunctional sensor (1)
- Multigassensoren (1)
- Multihop (1)
- Multirotor aircraft (1)
- Multivariate analysis (1)
- Nano UAV Swarm (1)
- New sensor principles (1)
- Nickel-/Nickel-Eisen- Magnetostriktion (1)
- Nitroaromaten (1)
- Odor localization (1)
- Oil (1)
- Oil spills (1)
- Olfaction (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- PVD-Haftfestigkeit (1)
- Passive sensor interface (1)
- Passive sensors (1)
- Pattern recognition methods (1)
- Permeation (1)
- Permeation method (1)
- Petrol (1)
- Petroleum (1)
- Phototransistor (1)
- Piezoresistive accelerometers (1)
- Porous building materials (1)
- Portable (1)
- Power-to-Gas (1)
- Prototyp (1)
- Prüfung (1)
- QI Digital (1)
- Quadruped robots (1)
- Quality Infrastructure (1)
- Quantification (1)
- Quantification of gas concentrations (1)
- RAM packages (1)
- RFID Sensor systems (1)
- RFID sensors systems (1)
- RFID Sensors systems (1)
- Radioactive (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Real-time (1)
- Reinforced concrete (1)
- Remote gas sensing (1)
- Remote sensing (1)
- Richtlinie (1)
- Risikoanalyse (1)
- SHT (1)
- Safety region model (1)
- Schadenfrüherkennung (1)
- Selbstkalibrierung (1)
- Selective permeability (1)
- Self-diagnosis (1)
- Sensoren (1)
- Sensorik (1)
- Sensorvalidierung (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Single cable system (1)
- Small scale test furnace (1)
- Small-scale Cone Calorimeter Untersuchungen (1)
- Smartphone (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Spatially distributed monitoring (1)
- Sphärische Indenter (1)
- Strain measurements (1)
- Structural Health Monitoring (1)
- Structural Health Monitoring (SHM) (1)
- Structure health monitoring (1)
- Subsurface (1)
- System adhesive/ strain gauge (1)
- TD-GC-MS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Technische Infrastruktur (1)
- Technische Überwachung (1)
- Temperaturabhängige Prüfung (1)
- Temperature behavior (1)
- Temperature and Frequency Compensation (1)
- Temperature behavior (1)
- Temperature behavior of a piezoresistive accelerometer (1)
- Temperature calibration (1)
- Temperature dependent and high dynamic load tests (1)
- Temperaturkompensation (1)
- Test (1)
- Test Streifen (1)
- Test gas generation (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Thrust (1)
- Tribologie (1)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS); UAV-REGAS (1)
- Tunable diode laser absorption Spectroscopy (TDLAS) (1)
- UAS (1)
- UHF antenna (1)
- UL94 (1)
- Uncertainty (1)
- Urban air monitoring (1)
- Validation (1)
- Vereinfachtes Verfahren (1)
- Verschiebungsfeld (1)
- Verteilte Sensorik (1)
- WLAN (1)
- WSN (1)
- Wasserstofferzeugung (1)
- Water quality (1)
- Water quality control (1)
- WiFi (1)
- Wind (1)
- Wind estimation (speed and direction) (1)
- Wind speed and direction (1)
- Windvektor (1)
- Windvektorbestimmung (1)
- Wireless mobile sensor device (1)
- Wischprobenahme (1)
- agricultural economy (1)
- binäres Regressionsverfahren (1)
- embedded sensor (1)
- environment (1)
- fluorescence (1)
- gas analysis (1)
- pH-Sensor (1)
- poly(propylene) (PP) (1)
- polymeren Baustoffen (1)
- poultry odorous air monitoring (1)
- spectroscopy (1)
- Öl (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (68)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (68)
- 1 Analytische Chemie; Referenzmaterialien (9)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (9)
- 1.9 Chemische und optische Sensorik (7)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 6 Materialchemie (2)
- 6.7 Materialsynthese und Design (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (33)
In Glasfasern eingeschriebene Bragg-Gitter (FBG: fibre-based Bragg gratings) sind über die Verschiebung der Bragg-Wellenlänge in der Lage, Stauchungen und Dehnungen von Glasfasern hochgenau zu erfassen. In Kompositwerkstoffe eingebettete faseroptische Sensoren können Bauteile bezüglich ihrer mechanischen Integrität überwachen und früh-zeitig Informationen über Materialveränderungen gewinnen.
Um die Zuverlässigkeit eines solchen Sensors zu gewährleisten, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit der Werkstoff-Matrix on-line und in-situ sicherzu-stellen. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnosefähiger Schichtsensor entwickelt, der mit Hilfe von magnetostriktiven Aktorschichten aus Nickel bzw. Eisen-Nickel validiert werden kann.
Der FAMOS²-Schichtsensor wird durch ein PVD (physical vapour deposition)/ECD (electro-chemical deposition) Hybridschichtsystem realisiert, das auf dem Fasermantel im Bereich des FBG haftfest, homogen und langzeitfunktional abzuscheiden ist. Dabei wird in einem ersten Schritt ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer als Haftvermittler auf der Glasfaser bzw. als leitfähige Startschicht für den nachfolgenden ECD-Prozess abgeschieden. Um eine rotationssymmetrische Schich-tabscheidung zu gewährleisten, erfolgt während der PVD-Beschichtung eine Rotation der Glasfasern. In einem zweiten Schritt wird dann unter Verwendung eines klassischen Watts-Elektrolyten in einer speziell entwickelten ebenfalls rotationssymmetrisch aufgebau-ten ECD-Durchströmungszelle dann die etwa 30 Mikrometer dicke, magnetostriktive Ak-torschicht auf dem PVD-Schichtsystem abgeschieden, im Vergleich sowohl reine Nickel-Schichten als auch Nickel-Eisen-Schichten.
Ein äußeres Magnetfeld dehnt die magnetostriktive Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke eines zu messenden oder zu Validierungszwecken vorgegebenen Magnetfeldes korreliert. Die Anpassung der Beschichtungsverfahren an die Fasergeome-trie und die mechanischen Eigenschaften der Hybridschichten werden hinsichtlich der me-chanischen Integrität des faseroptischen Sensors diskutiert und der Nachweis der Selbst-diagnosefähigkeit erbracht.
Flammschutz von polymeren Baustoffen: Bewertung von Konzepten auf der Basis von small- scale Cone Calorimeter Untersuchungen. In der Arbeit wurden zwei unterschiedliche Flammschutzkonzepte polymerer Baustoffe mit Hilfe des Cone Calorimeter untersucht und bewertet. Polymer-Schicht-Nanocomposites sind ein neues Konzept für flammgeschützte Werkstoffe, die aus einer Polymermatrix und der Zugabe eines nanoskaligen Schichtsilikat- Additivs von ca. 5 Gew.-% bestehen. Im Brandfall bilden die Schichtsilikate eine Barriere, die den Wärmetransport in das Material bzw. den Stofftransport der Pyrolysegase aus dem Material hemmt. Mit einem Modellsystem wurde gezeigt, dass dieser Barriereeffekt das Brandverhalten hinsichtlich der Flammenausbreitung verbessert, in anderen Brandszenarien aber wirkungslos bleibt. Die Ergebnisse der Cone Calorimeter Untersuchungen wurden mit denen der Entflammbarkeitstests UL 94 und LOI verglichen. Eine Korrelation in Richtung kleiner Probendimensionen (downscale) und in Richtung Phase der Brandentstehung wurde aufgezeigt. Die Anwendung intumeszierender Beschichtungen auf Bauteile verschiedener Art, wie z. B. tragende Stahlkonstruktionen, ist ein etabliertes Brandschutzkonzept. Das intumeszierende Polymermaterial schäumt unter Wärmeeinwirkung auf und bildet eine wärmeisolierende Schicht. Zur Bewertung der Wirkungsweise dieses Polymermaterials wurde ein auf Temperaturmessungen basierendes Verfahren mit dem Cone Calorimeter und für Simulationsrechnung entwickelt. Die Ergebnisse wurden mit denen aus Kleinprüfstanduntersuchungen verglichen. Eine Korrelation in Richtung großer Probendimensionen (upscale) und in Richtung der Phase des voll entwickelten Brandes konnte bis zu einer Temperaturgrenze gezeigt werden.
Eine Reihe von Prüfproblemen in der chemischen Industrie, in Kraftwerksanlagen und in Transportsystemen ist aufgrund schwieriger Zugangsmöglichkeiten nur begrenzt technisch bzw. wirtschaftlich effizient durchführbar. Das hier vorgestellte Projekt beinhaltet die Entwicklung eines Verfahrens der zerstörungsfreien Prüfung über weite Entfernungen (bis zu 100 m), das zum Einsatz in automatisierten Messsystemen bzw. zur Integration in Langzeitüberwachungssysteme geeignet ist. Grundlage des Verfahrens ist die gezielte Anregung und Auswertung von Lamb-Wellenmoden, wodurch eine effektive Unterscheidung von Fehler- und Formanzeigen sowie eine Klassifizierung unterschiedlicher Fehlertypen möglich werden.
Der Vorteil der Nutzung geführter Wellen für die zerstörungsfreie Prüfung liegt in ihrer vergleichsweise guten Ausbreitungsfähigkeit über weite Entfernungen. Die sich daraus ergebenden Möglichkeiten der Untersuchung großer bzw. schwer zugänglicher Bereiche einer Struktur bieten innovative Ansätze für die Entwicklung robuster Structural-Health-Monitoring-Systeme (SHM). Erst durch die Verfügbarkeit leistungsfähiger Rechentechnik wird ein breiter Einsatz derartiger Verfahren möglich. Die Technik kann zur Materialcharakterisierung an ebenen bzw. zylindrischen, dünnwandigen Flächen aus Metall oder auch CFK genutzt werden. Adressierte Anwendungsfelder sind z.B. die Untersuchung von Flugzeugtragflächen oder Pipelines. Des Weiteren wird der Einsatz solcher Verfahren zur Überwachung sicherheitsrelevanter Bauteile z.B. aus Laminaten angestrebt, wie sie verstärkt in der Luft- und Raumfahrt Anwendung finden. Im Rahmen des Projekts wurde auf Grundlage vorhandener Technik (Wellenanregung mittels Ultraschall-Gruppenstrahlprüfköpfen) ein umfassendes Verständnis für die Technologie und anwendungsrelevante Parameter (Probenmaterial und -dimensionen, Welleneigenschaften, Anregungs-, Transmissions-, Reflektionscharakteristika) gewonnen und Algorithmen zur Erkennung von Schädigungsbildern (z.B. Riss, Loch, Verdünnung) entwickelt.
Neben der Algorithmusentwicklung zur Detektion und Analyse von Schadstellen, lag ein Projektschwerpunkt in der Entwicklung einer geeigneten Gerätetechnik. Als sensorisches Elemente wurde Ultraschall-Gruppenstrahlertechnik eingesetzt. Besondere Anforderungen werden an die Technik zur Anregung der Wellenmoden unter Verwendung geeigneter Piezoaktoren gestellt. In diesem Bereich existiert bislang keine kommerziell erhältliche Gerätelösung, weshalb eine Neuentwicklug der Anregetechnik realisiert wurde. Speziell für die hohe Anzahl an Aktorkanälen, die benötigt wird, um unterschiedliche Moden und Wellenformen anzuregen, wurde eine äußerst leistungsfähige Anregeeinheit entwickelt.
Dehnungsmessstreifen (DMS) gehören zu den Standardsensoren beim Messen mechanischer Größen.
Sie finden Ihre Anwendung auf unterschiedlichen Gebieten, als sensorische Komponente in
Messaufnehmern (z.B. Wägezelle, Kraftaufnehmer) oder für Dehnungsmessungen im Bereich der
Strukturüberwachung unter anderem an Brücken oder Bauwerken. Sie werden in verschiedenen Größen
geliefert und mit entsprechenden Klebstoffen auf der Objektoberfläche des Messobjekts an der jeweiligen
Messstelle angebracht und an das Messsystem angeschlossen. Dieser Aufbau wird bei den
verschiedenen Anwendungen unterschiedlichen Temperaturen und Umwelteinflüssen ausgesetzt. Dabei
wird das System DMS/Klebstoff in seinen Eigenschaften verändert und das Ergebnis der
Dehnungsmessung beeinflusst. Beispielsweise kann es zu einer Verfälschung der Messergebnisse
kommen, wenn der Klebstoff die Dehnung des Messobjekts nicht vollständig auf den DMS überträgt, oder
es kann eine Nullpunktverschiebung der Dehnungsmessung auftreten.
An der Bundesanstalt für Materialforschung und -prüfung werden Fallversuche von Lager- und
Transportbehältern durchgeführt. Für diese werden Dehnungsmessstreifen auf den Behälter angebracht
um die Dehnung bzw. Verformung zu messen. Bei den Versuchen werden verschiedene Parameter
berücksichtigt: Neben unterschiedlichen Fallhöhen (u.a. 9 m und 1 m) wird auch der Temperatureinfluss
auf den Fallversuch z.B. bei -40 °C oder +100 °C untersucht. Zur Applizierung von DMS auf
Objektoberflächen gibt es für verschiedene Anwendungsbedingungen (DMS-Typ, Objektoberflächenbeschaffenheit,
Einsatztemperatur) von den DMS-Herstellern jeweils empfohlene Klebstoffe.
Insbesondere für Anwendungsfälle mit hochdynamischer Belastung (Fallversuche, Crash-Tests) und
großem Temperaturbereich ist es erforderlich, dass die Dehnungsmessstreifen zuverlässige Werte
ausgeben. Dies ist nur gegeben, wenn der Klebstoff eine gute Verbindung zwischen Messobjekt und
Dehnungsmessstreifen herstellt.