Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (41)
- Beitrag zu einem Tagungsband (34)
- Forschungsbericht (9)
- Beitrag zu einem Sammelband (8)
- Vortrag (2)
- Sonstiges (1)
Sprache
- Englisch (65)
- Deutsch (29)
- Mongolisch (1)
Schlagworte
- Bauprodukte (13)
- Geruch (13)
- Emissionen (9)
- VOC (9)
- Human factors (7)
- Odour (6)
- BAM-Zulassung (4)
- Deponieverordnung (4)
- Geokunststoffe (4)
- AgBB-Schema (3)
Organisationseinheit der BAM
- 4 Material und Umwelt (9)
- 4.2 Material-Mikrobiom Wechselwirkungen (7)
- 8 Zerstörungsfreie Prüfung (7)
- 8.5 Röntgenbildgebung (7)
- 6 Materialchemie (5)
- 6.1 Oberflächen- und Dünnschichtanalyse (2)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.4 Sicherheit von Lagerbehältern (1)
Eingeladener Vortrag
- nein (2)
Messung der empfundenen Geruchsintensität mit Multigas-Sensorsystemen, das Forschungsvorhaben SysPAQ
(2007)
Measuring perceived air quality and intensity by a Sensor System, the European Project SysPAQ
(2008)
In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation.
Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources.
Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related
Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials.
Um eine gute Luftqualität in Gebäuden zu erreichen, müssen Reinigungslasten durch Lüften aus Räumen abgeführt bzw. vermieden oder verringert werden. Wird der Luftwechsel verringert, verschlechtert sich die Raumluftqualität, und die Zufriedenheit der Nutzer nimmt ab. An Arbeitsplätzen kann es bei schlechter Luftqualität und der daraus resultierenden Unzufriedenheit zu einer geringeren Produktivität der Beschäftigten kommen. Um die Reinigungslasten und deren Wirkung auf den Raumnutzer überdas Geruchsempfinden zu verringern, ist neben einer messtechnischen Erfassung der Verunreinigungen auch eine sensorische Prüfung in Innenräumen und von Bauprodukten notwendig. In diesem Artikel wird die Entwicklung der Bewertungsmethodik von Gerüchen im Innenraum erläutert und auf Anwendungen eingegangen.
Emissionen aus Bauprodukten beeinträchtigen die Qualität der Innenraumluft erheblich. Mit Hilfe des AgBB-Schemas werden die Emissionen flüchtiger organischer Verbindungen (VOC) aus Bauprodukten bewertet. Die gesundheitliche Bewertung nach dem AgBB-Schema erfordert produktspezifische Messverfahren.
Diese gibt es mittlerweile für eine Reihe von Produkten. Sie wurden durch Beteiligung verschiedener Forschungseinrichtungen und Messinstitute validiert und u. a. in die Vergabekriterien des Umweltzeichens Blauer Engel übernommen. Die Bewertung ist allerdings mit zumeist niedrigeren Grenzwerten strenger. VOC-Emissionen und Gerüche können beide zu gesundheitlichen Belastungen führen. So ist die sensorische Prüfung ein weiteres wichtiges Element bei der Bewertung von Bauprodukten und vorsorglich auch im AgBB-Schema verankert.
Hauptziel des Projektes ist es, eine Methode der sensorischen Bewertung und Grenzen für die Vergabe des Blauen Engels und für das AgBB-Schema abzuleiten. Auf Grundlage der durchgeführten Untersuchungen (siehe Kapitel 5 Ergebnisse und Diskussion) wird als Bewertungsmethode die empfundene Intensität und die Hedonik vorgeschlagen. Die Ableitung der Grenzwerte für die sensorische Bewertung am 28. Tag erfolgt über die zusätzliche Befragung der Probanden im Rahmen der vorliegenden Studie nach der Zumutbarkeit einer Probe.
Für den Blauen Engel könnte es je Produktgruppe unterschiedliche Grenzen der empfundenen Intensität und der Hedonik geben. Ein erster Vorschlag für mögliche Grenzen, hier zunächst einheitlich für alle
Produktgruppen, ist für die empfundene Intensität 7 pi (5 pi + 2 pi als Sicherheit, Kapitel 5.1.5) und für die Hedonik -1 (0 +/-0,8, gerundet auf -1) (siehe dazu Abbildung 6-2).
Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures.
These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel.
The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample.
For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value.
VOC emissions from building materials accompanying sensory tests for different evaluation schemes
(2011)
Within a follow up project of a former study (Horn et al. 2005) emissions and odor from different types of construction products were investigated (financed by the German Federal Environmental Agency - FKZ 37 07 62 300).
The tested materials were mainly those used for construction of floors indoors. For this type of materials in Germany several labeling procedures exist which are based on Emission chamber testing. Two important labeling procedures in Germany are based on the AgBBevaluation scheme (Däumling et al. 2005). For some applications (flooring material) it is the mandatory Ü-mark of DIBt (German Institute for Construction Technology). Furthermore for carpets, adhesives and many other products, like sealants, mattresses, furniture and so on the voluntary blue angel mark exist. Within this scheme the volatile organic compounds (VOC) compounds are measured with well established procedures and are evaluated with LCI-values which were derived from health information.
Beyond that many complaints according to building products are caused by odors. Therefore an evaluation procedure for the odor is very important and should be implemented into all of the mentioned labeling schemes.
Kunststoff- und Kunststoffrasenflächen kommt bei intensiv genutzten Flächen als Allwetterbeläge eine große Bedeutung zu. Sie leisten einen wichtigen Beitrag zur Absicherung eines ganzjähriger Sportangebote.
Gerade Kunststoffrasen ist aber in den letzten Jahren häufig in die Kritik geraten, insbesondere durch gefährliche Inhaltsstoffe und andere negative Einflüsse auf die Umwelt. Dies hat bei Bauherren zu einer Verunsicherung geführt und Fragen aufgeworfen, die erst teilweise beantwortet sind. Die Diskussionen rund um diesen Allwetterbelag haben bereits dazu geführt, dass von Seiten der Industrie viel verändert wurde und neue innovative Lösungen gefunden werden.
Der Fachbericht stellt eine Handreichung für Fachleute und interessierte Laien dar, um mehr Klarheit besonders hinsichtlich der Umweltanforderungen zu erzielen.
Confocal micro-X-ray fluorescence (micro-XRF) spectroscopy facilitates three-dimensional (3D) elemental imaging of heterogeneous samples in the micrometer range. Laboratory setups using X-ray tube excitation render the method accessible for diverse research fields but interpretation of results and quantification remain challenging. The attenuation of X-rays in composites depends on the photon energy as well as on the composition and density of the material. For confocal micro-XRF, attenuation severely impacts elemental distribution information, as the signal from deeper layers is distorted by superficial layers. Absorption correction and quantification of fluorescence measurements in heterogeneous composite samples have so far not been reported. Here, an absorption correction approach for confocal micro-XRF combining density information from microcomputed tomography (micro-CT) data with laboratory X-ray absorption spectroscopy (XAS) and synchrotron transmission measurements is presented. The energy dependency of the probing volume is considered during the correction. The methodology is demonstrated on a model composite sample consisting of a bovine tooth with a clinically used restoration material.
27Al nuclear magnetic resonance spectra of polycrystalline aluminium borate 9Al2O3 · 2B2O3 have been measured in double rotation at 11.7 and 7.0 T and high-speed magic-angle spinning at 7.0, 9.4, 11.7, 14.1 and 17.6 T. Spinning sidebands from the satellite transitions were observed at 7.0 and 14.1 T. Each of the four structural aluminium sites [Al(IV), Al(V)(1), Al(V)(2) and Al(VI)] are observed, characterised and assigned in the spectra. The obtained parameter set gives a fully consistent interpretation in agreement with the crystal structure of the compound.
We have carried out some laboratory experiments to establish possibilities to melt 16Na2O*10CaO*74SiO2 glasses from consisting of mainly quarz sands of Buir nuur lake. When the sands used directly, the formed glasses had slight blue colour, the origin of which may be connected with aluminium and iron impurities in the sands. Presence of these impurities is confirmed by chemical analyse and ESR study data. Allso have been studied liquid gas extraction phenomena in the sands and melted glass samples and determined some physical properties of them.
Results are reported from a pilot study under the Consultative Committee for Amount of Substance (CCQM) to compare measurements of and resolve any relevant measurement issues in, the amount of thermal SiO2 oxide on (100) and (111) orientation Si wafer substrates in the thickness range 1.5 - 8 nm. As a result of the invitation to participate in this activity, 45 sets of measurements have been made in different laboratories using 10 analytical methods: medium-energy ion scattering spectrometry (MEIS), nuclear reaction analysis (NRA), RBS, elastic backscattering spectrometry (EBS), XPS, SIMS, ellipsometry, grazing-incidence x-ray reflectrometry (GIXRR), neutron reflectometry and transmission electron microscopy (TEM). The measurements are made on separate sets of 10 carefully prepared samples, all of which have been characterised by a combination of ellipsometry and XPS using carefully established reference conditions and reference parameters.
The results have been assessed against the National Physical Laboratory (NPL) data and all show excellent linearity. The remaining data sets correlate with the NPL data with average root-mean-square scatters of 0.15 nm, half being better than 0.1 nm and a few at or better than 0.05 nm. Each set of data allows a relative scaling constant and a zero thickness offset to be determined. Each method has an inherent zero thickness offset between 0 nm and 1 nm and it is these offsets, measured here for the first time, that have caused many problems in the past. There are three basic classes of offset: water and carbonadeous contamination equivalent to ~1 nm as seen by ellipsometry; adsorbed oxygen mainly from water at an equivalent thickness of 0.5 nm as seen by MEIS, NRA, RBS and possibly GIXRR; and no offset as seen by XPS using the Si 2p peaks. Each technique has a different uncertainty for the scaling constant and consistent results have been achieved. X-Ray photoelectron spectroscopy has large uncertainties for the scaling constant but a high precision and, critically, if used correctly, has zero offset. Thus, a combination of XPS and the other methods allows the XPS scaling constant to be determined with low uncertainty, traceable via the other methods. XPS laboratories returning results early were invited to test a new reference procedure. All showed very significant improvements. The reference attenuation lengths thus need scaling by 0.986 ± 0.009 (at an expansion factor of 2) deduced from the data for the other methods. Several other methods have small offsets and, to the extent that these can be shown to be constant or measurable, then these methods will also show low uncertainty. Recommendations are provided for parameters for XPS, MEIS, RBS and NRA to improve their accuracy.
Micro-computed tomography (µCT) provides quantitative three-dimensional information of bone around titanium implants similar to classical histology. The study, based on an animal model, using cuboid-shaped biofunctionalised Ti6Al4V implants with surrounding bone after 4 weeks, is performed using 3 µCT-systems with X-ray tubes, one synchrotron-radiation-based µCT-system (SRµCT), and classical histology. Although the spatial resolution of the µCTsystems is comparable, only the results of SRµCT agree with results of classical histology. The X-ray tube sources give rise to huge artefacts in the tomograms (interface scattering, beam hardening), which impaired the quantitative analysis of bone up to about 200 µm from the implant surface. Due to the non-destructive character of µCT the specimens can be subsequently examined by classical histology
without restriction. The quantitative comparison of bone formation uncovers the strong dependence of the detected amount of newly formed bone from the selected slice. This
implies the necessity of 3D analysis. SRµCT and classical histology prove that surface modifications of the titanium implant significantly influence the bone formation. Using SRµCT, the preparation artefacts due to cutting and polishing are excluded.
Der Artikel beschreibt eine arbeitspsychologische Analyse des Einflusses der menschlichen Faktoren auf die Zuverlässigkeit zerstörungsfreier Prüfungen (ZfP). Im Zeitraum von 5 Jahren wurde eine Serie von Untersuchungen zur wiederkehrenden Prüfung in Kernkraftwerken sowie zur Prüfung von Komponenten für die Endlagerung von radioaktivem Abfall durchgeführt. Dieser Beitrag gibt einen Überblick über vier Studien, diskutiert ausgewählte experimentelle Ergebnisse, und schlägt sich daraus ergebende Möglichkeiten zur Optimierung des ZfP-Verfahrens, der Prüfanweisung sowie zur Schulung des Personals vor. Die experimentellen Ergebnisse haben gezeigt, dass sowohl hoher Zeitdruck als auch hohe psychische Arbeitsbeanspruchung die Qualität des Prüfungsergebnisses negativ beeinflussen. Auffällig waren die Einflüsse der Einteilung des Arbeitsplans, der Kommunikation, der Prüfanweisung, der Prüfaufsicht sowie der Demonstrationsübung. Die abgewandelte Fehlermöglichkeits- und Einflussanalyse (Failure Mode and Effects Analysis FMEA) wurde zur Identifizierung potentieller menschlicher Risiken während der Datenaufnahme und deren Auswertung benutzt. Darauf basierend werden verschiedene Präventivmaßnahmen, wie z.B. menschliche Redundanz und Automatisierung vorgeschlagen, sowie sich daraus möglicherweise ergebende Probleme diskutiert. Die experimentellen Ergebnisse haben gezeigt, dass menschliche Redundanz bei kritischen Anwendungen, wie beispielweise der Fehleridentifizierung, zu anderen Fehlerquellen führen kann, wie sozialem Faulenzen bei den Prüfern. Die Verwendung automatisierter softwarebasierter Entscheidungshilfen zur Fehlererkennung bzw. Fehlergrößenbestimmung kann zu übersteigertem Vertrauen in das automatisierte System (automation bias) durch die Prüfer und somit zu Fehlentscheidungen führen. Dadurch kann die Zuverlässigkeit der Prüfung in ungewollter Weise beeinflusst werden. Um die Zuverlässigkeit und Sicherheit der technischen Prozesse zu gewährleisten ist es wichtig, als Hauptfehlerquelle nicht mehr nur das einzelne Individuum zu sehen, sondern ebenfalls die Organisation zu berücksichtigen.
The present work shows results on elemental distribution analyses in Cu(In,Ga)Se2 thin films for solar cells performed by use of wavelength-dispersive and energy-dispersive X-ray spectrometry (EDX) in a scanning electron microscope, EDX in a transmission electron microscope, X-ray photoelectron, angle-dependent soft X-ray emission, secondary ion-mass (SIMS), time-of-flight SIMS, sputtered neutral mass, glow-discharge optical emission and glow-discharge mass, Auger electron, and Rutherford backscattering spectrometry, by use of scanning Auger electron microscopy, Raman depth profiling, and Raman mapping, as well as by use of elastic recoil detection analysis, grazing-incidence X-ray and electron backscatter diffraction, and grazing-incidence X-ray fluorescence analysis. The Cu(In,Ga)Se2 thin films used for the present comparison were produced during the same identical deposition run and exhibit thicknesses of about 2 µm. The analysis techniques were compared with respect to their spatial and depth resolutions, measuring speeds, availabilities, and detection limits.
Die übergeordnete Zielsetzung unserer Untersuchung bestand darin,
am Beispiel von Prüfungen mit Ultraschall eine belastbare Aussage zum Einfluss der Arbeitsbedingungen des Prüfers auf die Qualität der Ergebnisse von zerstörungsfreien Prüfungen zu ermitteln und Möglichkeiten zur Minimierung ungünstiger Einflussfaktoren aufzuzeigen.
Der Schwerpunkt der Untersuchung wurde auf die manuelle Ultraschallprüfung gelegt und der Faktor 'Zeitdruck' (in drei Stufen variiert) als die zu variierende physische Einflussgröße gewählt. Die Variation des Faktors Zeitdruck wurde gemäß dem Prozessmodell von der Erhebung psychologischer Faktoren, die das Individuum und die Organisation beschreiben, begleitet.
Die Ultraschallprüfungen erfolgten mit zehn Prüfern am Großbehälter und an Vergleichskörpern mit eingebrachten Testfehlern (Nuten, Risse). Die ausgewählten Fehler waren typisch für Prüfaufgaben, die bei wiederkehrenden Ultraschallprüfungen in Kernkraftwerken von den Prüfern zu lösen sind. Die Prüfaufgabe bestand darin, die in den vorgegebenen Prüfabschnitten vorhandenen Reflektoren aufzufinden und deren Amplituden, Ortskoordinaten und Längenerstreckungen zu ermitteln. Als Bewertungsmaßstab für die Qualität der Prüfaussage und für den Einfluss des menschlichen Faktors diente die Präzision der gemessenen Werte. Die Ergebnisse zeigen einen hohen Einfluss des menschlichen Faktors auf das Prüfergebnis und eine Einwirkung des Zeitdrucks besonders auf die Präzision der Messwerte. Hierbei war die Wirkung des individuell wahrgenommenen Zeitdrucks zusammen mit der psychischen Arbeitsbeanspruchung signifikant. Es wurde unter anderem herausgearbeitet, dass durch eine gute Vorbereitung auf die Prüfung, z.B. durch die sorgfältige Einweisung und ein vorgeschaltetes Fertigkeitstraining an Vergleichskörpern, die Zuverlässigkeit der Prüfergebnisse verbessert werden kann.
Insgesamt hatte der Faktor 'Organisation' neben der 'Erfahrung' einen hohen Einfluss auf das Leistungsvermögen der Prüfer.
Die Projektergebnisse wurden im Abschlussbericht des Forschungsvorhabens SR2514 dargestellt, es wurden drei Empfehlungen zur Vorbereitung und Einweisung der Prüfer, zur Stärkung der Verantwortung der Prüfaufsicht und zum 4-Augen-Prinzip formuliert. Die Empfehlungen wurden in der KTA- Regel 3201.4 'Komponenten des Primärkreises von Leichtwasserreaktoren; Teil 4: Wiederkehrende Prüfungen und Betriebsüberwachung (RÄE Fassung 2010-11)', umgesetzt.
Für eine ganzheitliche Betrachtung der Sicherheit bei der zerstörungsfreien Prüfung (ZfP) ist es unvermeidlich neben der Technik auch den Prüfer und die Prüforganisation einzubeziehen. Die Prüfung der Unversehrtheit von Endlagerbehältern ist eine eine sicherheitstechnisch wichtige Anwendung. Die Betreiber der geplanten finnischen und schwedischen Endlager, Posiva und SKB, kapseln den radioaktiven Abfall in Kupferkanistern ein und deponieren die Kanister dann in Felsgestein in einer Tiefe von ca. 500m. Die Kanister bestehen aus einem zylinderförmigen Kupfermantel mit einem Deckel und einem Boden, die zusammen die Außenumhüllung ergeben sowie einer Gusseisenmatrix für die Brennstäbe. Alle Komponenten werden auf ihre Dichtheit bzw. strukturelle Unversehrtheit mittels zerstörungsfreier Prüfmethoden geprüft, um sicher zu stellen, dass im Material und in den Schweißnähten keine kritischen Defekte vorhanden sind, die zu Freisetzungen in die Umgebung führen könnten. Vier ZfP Methoden (Ultraschall-, Wirbelstrom- und radiographische Prüfung, und die visuelle Prüfung anhand einer Kamera) werden mechanisiert durchgeführt, die gewonnenen Daten werden von qualifizierten Fachleuten ausgewertet und bieten so die Möglichkeit, dass Fehler entstehen.
Das 'Human Factor'- Untersuchungskonzept besteht aus der Identifizierung potenzieller menschlicher Fehler, deren Ursachen und Präventionsmethoden. Mit Hilfe einer abgewandelten FMEA (Failure Modes and Effects Analysis) wurden mögliche Risiken identifiziert, die die Wahrscheinlichkeit für das Auftreten menschlicher Fehler bei
der Datenauswertung erhöhen. Einige dieser Risiken sind beispielsweise
Verantwortungsdiffusion beim 4-Augen-Prinzip, Übervertrauen in die Technik bei der automatischen Identifikation von Defekten sowie der Aufmerksamkeitsverlust bei dynamischer Bildbetrachtung. Deren Wirkung wird derzeit experimentell überprüft, um Ansatzpunkte für Optimierungen zu ermitteln und damit die Gesamtzuverlässigkeit des Systems zu verbessern.
This paper gives an introduction to the field of human factors with the focus on their influence on the reliability of NDT in the nuclear energy production (in-service inspections) and final storage of highly radioactive nuclear waste. A set of methodological tools has been developed in the scope of three projects, namely: 1) a theoretical model describing potential human factors influencing manual ultrasonic inspection performance during inservice inspections in nuclear power plants; 2) a method for identifying potential human errors during acquisition and evaluation of data gathered with mechanized ultrasonic, radiographic and eddy-current systems, as well as visual testing with a remote camera (Failure Modes and Effects Analysis, FMEA); and 3) use of eye tracking methodology to optimize existing procedures and practices. The experimental results have shown that time pressure, mental workload and experience influence the quality of the inspection performance. Noticeable were influences from the organization of the working schedule, communication, procedures, supervision and demonstration task. Implementing human redundancy in critical tasks, such as defect identification, as well as using an automated aid (software) to help operators in decision making about the existence and size of defects, could lead to other kinds of problems, namely social loafing (excerpting less effort when working on tasks collectively as compared to working alone) and automation bias (uncritical reliance on the proper function of an automated system without recognizing its limitations and the possibilities of automation failure) that might affect the reliability of NDT in an undesired manner.
Die neue Deponieverordnung regelt im Anhang 1 auch den Einsatz von Geokunststoffen im Deponiebau. Deren Eignung muss der zuständigen Behörde gegenüber nachgewiesen werden. Auf die entsprechenden Regelungen wurde im ersten Teil dieses Aufsatzes eingegangen. Zumindest in den nächsten Jahren kommt nur ein Nachweis durch Vorlage einer Zulassung der BAM Bundesanstalt für Materialforschung und -prüfung in Betracht. Das Zulassungsverfahren wird in der Deponieverordnung geregelt. Die Zulassungsbehörde soll u.a. nicht nur ein bestimmtes Produkt auf der Grundlage von Zulassungsrichtlinien überprüfen, sondern auch in Zusammenarbeit mit einem Fachbeirat Anforderungen an den fachgerechten Einbau und das Qualitätsmanagement festlegen. Das Zulassungsverfahren und einige wesentliche technische Zulassungsanforderung, die für Kunststoffdichtungsbahnen, Schutzschichten, Geotextilien, Kunststoff-Dränelement, Bewehrungsgitter aus Kunststoff und Dichtungskontrollsysteme inzwischen erarbeitet und in Zulassungsrichtlinien beschrieben wurden, werden erläutert.
The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA)
(2008)
The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed.
The human factors approach relies on understanding the properties of
human capability and limitations under various conditions and the application of that
knowledge in designing and developing safe systems. Following the principles of
MTO (Man Technology Organization) approach, emphasis should be given to the
way people interact with technical as well as organizational systems.
A model describing human factor influences in relation to the performance shaping
factors and their effect on the manual ultrasonic inspection performance had been
built and a part of it empirically tested. The experimental task involved repeated
inspection of 18 flaws according to the standard procedure under no, middle and
high time pressure. Stress coping strategies, mental workload of the task, stress
reaction and organizational factors have been measured. The results have shown that
time pressure, mental workload and experience influence the quality of the
inspection performance. Organizational factors and their influence on the inspection
results were rated as important by the operators. However, further research is
necessary into the effects of stress.
External and internal head structures of adults of Galloisiana yuasai (Grylloblattodea) are described. The results are compared with conditions found in representatives of other lower neopteran lineages, notably in Austrophasma and Karoophasma (both Mantophasmatodea). Sutures and ridges of the head capsule are discussed. A new nomenclature for head muscles is presented for the entire Dicondylia (= Zygentoma + Pterygota). Galloisiana (like its sister taxon Grylloblatta) is mostly characterized by plesiomorphic features, such as the largely unspecialized orthopteroid mouthparts, the multisegmented filiform antennae, the presence of trabeculae tentorii, the absence of muscles associated with the antennal ampullae, the presence of musculus stipitalis transversalis (0mx11) and the presence of musculus tentoriofrontalis anterior (0te2). Autapomorphies of Grylloblattodea are: (i) compound eyes composed of only 60 ommatidia or less; (ii) a lacinia with a proximal tooth; (iii) a rounded submentum; (iv) loss of musculus craniohypopharyngealis (0hy3); and (v) loss of musculus labroepipharyngealis (0lb5). The phylogenetic evaluation of 104 characters of the head yields a branching pattern with Grylloblattodea as a sister group of Mantophasmatodea in clade Xenonomia. Putative synapomorphies of both taxa are: (i) a distinct angle (more than 60°) between the submentum and the mentum; (ii) posteriorly oriented labial palpi; (iii) a flat and lobe-like hypopharynx with a suspensorium far ventrad of the anatomical mouth opening; (iv) loss of musculus tentorioparaglossalis (0la6); and (v) a connection between the antennal ampulla and the supraoesophageal ganglion containing nuclei. Xenonomia is placed in a clade with the two dictyopteran terminals. Another monophyletic group is Embioptera + Phasmatodea. Most branches of the single tree obtained in our analysis are weakly supported. The results clearly show that more data and a much broader taxon sampling are required to clarify the phylogenetic interrelationships of the lower neopteran orders. However, our results narrow down the spectrum of possible solutions, and represent a starting point for future phylogenetic analyses, with an extensive concatenated dataset.
Overview of different strengthening techniques applied on walls used in historical structures
(2012)
The human factors approach relies on understanding the properties of human capability and limitations under various conditions and the application of that knowledge in designing and developing safe systems. Following the principles of the MTO (Man Technology Organisation) approach, emphasis should be given to the way people interact with technical as well as organisational systems.
A model describing human factor influences in relation to the performance shaping factors and their effect on manual ultrasonic inspection performance had been built and a part of it empirically tested. The experimental task involved repeated inspection of 18 defects according to the standard procedure under no, middle and high time pressure. Stress coping strategies, the mental workload of the task, stress reaction and organisational factors have been measured. The results have shown that time pressure, mental workload and experience influence the quality of the inspection performance. Organisational factors and their influence on the inspection results were rated as important by the operators. However, further research is necessary into the effects of stress.
Die Integrität der Verstärkungsfasern in Komposit-Zahnstiften ist entscheidend für die Biegefestigkeit und die langfristige Haftung am Zement in den Wurzelkanälen. Es wurde vermutet, dass die Integrität von glasfaserverstärkten Zahnstiften durch das Beschleifen während der zahnmedizinischen Behandlung beeinträchtigt wird. Eine Beschädigung der Fasern führt zu einer erheblichen strukturellen Schwächung über den gesamten Stiftdurchmesser. Glasfragmente, die durch den Kontakt mit dem Zahnbohrer entstehen, können sich vom Stift lösen und die Haftfähigkeit erheblich verringern. Mit Hilfe hochauflösender Synchrotron-Röntgen-Refraktions-Radiographie (SXRR) konnte das Ausmaß der Schäden zuverlässig identifiziert und charakterisiert werden.
Dazu wurden die Glasfaserstifte sowohl im Herstellungszustand als auch nach der Bearbeitung mit einem Diamantbohrer untersucht. Die Datensätze wurden zur Visualisierung und Quantifizierung der morphologischen Charakteristika intakter und durch das Beschleifen beschädigter Regionen analysiert. Sie zeigen Schäden im bearbeiteten Bereich (z. B. Brüche, Splitter und Risse) sowie herstellungsbedingte Inhomogenitäten der Fasern mit einer signifikanten Zunahme der inneren Oberflächen in Probenregionen, die durch das Beschleifen beschädigt wurden.
size limitations and high production costs of L-PBF make it competitive for smaller, highly complex components, while the less complex elements of an assembly are manufactured conventionally. This leads to scenarios that use L-PBF only where it’s beneficial, and it require an integration and joining to form the final product. For example, L-PBF combustion swirlers are welded onto cast parts to produce combustion systems for stationary gas turbines. Today, the welding process requires complex welding fixtures and tack welds to ensure the correct alignment and positioning of the parts for repeatable weld results. In this paper, L-PBF and milled weld preparations are presented as a way to simplify the Tungsten inert gas (TIG) welding of rotationally symmetrical geometries using integrated features for alignment and fixation. Pipe specimens with the proposed designs are manufactured in Inconel 625 using L-PBF and milling. The pipe assembly is tested and TIG welding is performed for validation. 3D scans of the pipes before and after welding are evaluated, and the weld quality is examined via metallography and computed tomography (CT) scans. All welds produced in this study passed the highest evaluation group B according to DIN 5817. Thanks to good component alignment, safe handling, and a stable welding process, the developed designs eliminate the need for part-specific fixtures, simplify the process chain, and increase the process reliability. The results are applicable to a wide range of components with similar requirements.
The morphology of the antennal hearts in the head of Phasmatodea and Embioptera was investigated with particular reference to phylogenetically relevant key taxa. The antennal circulatory organs of all examined species have the same basic construction: they consist of antennal vessels that are connected to ampullae located in the head near the antenna base. The ampullae are pulsatile due to associated muscles, but the points of attachment differ between the species studied. All examined Phasmatodea species have a Musculus (M.) interampullaris which extends between the two ampullae plus a M. ampulloaorticus that runs from the ampullae to the anterior end of the aorta; upon contraction, all these muscles dilate the lumina of both ampullae at the same time. In Embioptera, only the australembiid Metoligotoma has an M. interampullaris. All other studied webspinners instead have a M. ampullofrontalis which extends between the ampullae and the frontal region of the head capsule; these species do not have M. ampulloaorticus. Outgroup comparison indicates that an antennal heart with a M. interampullaris is the plesiomorphic character state among Embioptera and the likely ground pattern of the taxon Eukinolabia. Antennal hearts with a M. ampullofrontalis represent a derived condition that occurs among insects only in some embiopterans. These findings help to further clarify the controversially discussed internal phylogeny of webspinners by supporting the view that Australembiidae are the sister group of the remaining Embioptera.
Since the beginnings of the European American Workshops (EAW) in 1997, the aim was to gather the experts in NDE reliability and discuss burning topics with the aim of identifying crucial problems and suggesting ways to move forward. This was usually achieved during the so-called break-out sessions, in which predetermined topics were discussed. During the 5th EAW, held in Berlin in 2013, this approach was replaced by an Open Space Technology (OST) approach. The benefit of this approach is seen in the freedom of topic choices, i. e., the topics are not predetermined but rather arise at that moment in that space and by the participants choice. The following topics arose: new reliability methods (Bayesian, MAPOD,
), structural health monitoring, definition of requirements of NDE by customer versus provider, what value of POD is good enough?, human factors, manual versus automated inspection, and basic concepts of reliability of NDE. The participants were encouraged to walk from one session to another and openly express their opinions. These were in the end summarized by a chosen group of moderators and presented in this paper.
We developed new procedures for internal standardization and calibration to be used for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for elemental micro mapping imaging of biological samples like Western blot membranes and tissue sections. These procedures are based on printing of metal spiked inks onto the top of thin layer samples for simultaneous internal standardization and calibration of LA-ICP-MS. In the case of internal standardization the ink is spiked with indium as an internal standard and homogenously printed over the entire membrane (size 56 cm2) prior to LA-ICP-MS detection, a standard deviation (RSD) value of 2% was achieved. In the second approach the metal content of lanthanide tagged proteins and antibodies after biological work flows was quantified by LA-ICP-MS on nitro-cellulose membranes. In this case the inks spiked with varying metals were printed with different densities on the same nitrocellulose membranes in well-defined squares to produce matrix-matched calibration standards. For validation and calibration the ink squares were excised and the specific metal content was measured by liquid ICP-MS after solubilization of the membrane slice. For the printed calibration standard limits of detection (LOD) of <4 fmol for different metals and relative process standard deviations of 12% only were determined via LA-ICP-MS.
Human factors approach to the reliability of NDT in nuclear waste management in Sweden and Finland
(2010)
Nuclear power industry has the responsibility to manage and dispose of all radioactive waste from its
plants. Finnish Posiva and Swedish SKB are leading in the world in the development of disposal of
spent nuclear fuel. Their method consists of encapsulating spent nuclear fuel in copper canisters and
depositing them in the bedrock at a depth of about 500 meters for the next 100 000 years, leaving the
radioactivity to decrease naturally through the decay of the radioisotopes in it. The copper canisters,
consisting of a copper tube, a lid and a bottom (which make the outer shell) and an insert made of a
cast iron, need to be inspected for their structural integrity to ensure no critical defects are present in
the materials and welds that could lead to a leakage of the waste into the environment. Data acquired
by 4 different non-destructive testing (NDT) methods (i.e. UT, ET, RT and VT with a remote camera)
are evaluated by skilled human operators and therefore could be subject to human error.
Human Factors approach lies in identifying potential errors made by the human, their causes
and ways of preventing them. A customized Failure Modes and Effects Analysis (FMEA) was
conducted to anticipate possible human failures during the data evaluation. The results led to
designing several experiments (e.g. diffusion of responsibility within the 4-eye principle, over trust in
automated systems) which are being experimentally tested in ongoing projects. The results are
expected to lead to the optimization of the procedures followed by the NDT operators and
consequently to the improvement of the overall NDT reliability.
Concrete is by far the most common building material in the world. Due to its good durability it is widely used in building envelopes. One major part of the embodied energy in concrete comes from the production of Portland cement that consumes around 3,500 MJ energy per each ton of cement. Globally 2.6 billion tons of Portland cement is produced and the consumption is increasing. Since concrete will be used as main building material also in future construction, it is reasonable to develop concrete building components with lower embodied energy.Using the example of an ultra-high performance concrete (UHPC) façade element, it is demonstrated how the embodied energy can be reduced by application of hydrothermal curing.
Geruchslabel für Bauprodukte
(2009)
We present a handheld fiber-coupled terahertz spectrometer operating at a center wavelength of 1550 nm. The key elements are a fs-fiber laser, a fiber stretcher delay line and fiber-coupled antennas, which contain novel InAlAs-InGaAs multi layer chips. First experimental data obtained with this system demonstrates its great potential and robustness. In addition, we investigate different hazardous and harmless liquids in reflection geometry. These experiments show that liquids are in principle distinguishable by terahertz spectroscopy. Finally, first steps towards an algorithm that allows for an extraction of the liquids dielectric properties are discussed. The algorithm works for the analysis of reflection data even if the liquid is located inside a container.
An energy-based method to determine material constants in nonlinear rheology with applications
(2016)
Many polymer-type materials show a rate-dependent and nonlinear rheological behavior. Such a response may be modeled by using a series of spring-dashpot systems. However, in order to cover different time scales the number of systems may become unreasonably large. A more appropriate treatment based on continuum mechanics will be presented herein. This approach uses representation theorems for deriving material equations and allows for a systematic increase in modeling complexity. Moreover, we propose an approach based on energy to determine thematerial parameters.This method results in a simple linear regression problemeven for highly nonlinearmaterial equations. Therefore, the inverse problem leads to a unique solution. The significance of the proposed method is that the stored and dissipated energies necessary for the procedure are measurable quantities. We apply the proposed method to a 'semi-solid' material and measure its material parameters by using a simple-shear rheometer.
The in situ analysis of the damage evolution in a metal Matrix composite (MMC) using synchrotron X-ray refraction radiography (SXRR) is presented. The investigated material is an Al alloy (6061)/10 vol% Al2O3 MMC after T6 heat treatment.
In an interrupted tensile test the gauge section of dog bone-shaped specimens is imaged in different states of tensile loading. On the basis of the SXRR images, the relative change of the specific surface (proportional to the amount of damage) in the course of tensile loading was analyzed. It could be shown that the damage can be detected by SXRR already at a stage of tensile loading, in which no Observation of damage is possible with radiographic absorption-based imaging methods.
Moreover, the quantitative analysis of the SXRR images reveals that the amount of damage increases homogeneously by an average of 25% with respect to the Initial state. To corroborate the experimental findings, the damage distribution was imaged in 3D after the final tensile loading by synchrotron X-ray refraction computed tomography (SXRCT) and absorption-based synchrotron X-ray computed tomography (SXCT). It could be evidenced that defects and damages cause pronounced indications in the SXRCT images.
The indication-oriented Dental Bone Graft Substitutes (DBGS) selection, the correct bone defects classification, and appropriate treatment planning are very crucial for obtaining successful clinical results. However, hydrophilic, viscoelastic, and physicochemical properties’ influence on the DBGS regenerative potential has poorly been studied. For that reason, we investigated the dimensional changes and molecular mobility by Dynamic Mechanical Analysis (DMA) of xenograft (cerabone®), synthetic (maxresorb®), and allograft (maxgraft®, Puros®) blocks in a wet and dry state. While no significant differences could be seen in dry state, cerabone® and maxresorb® blocks showed a slight height decrease in wet state, whereas both maxgraft® and Puros® had an almost identical height increase. In addition, cerabone® and maxresorb® blocks remained highly rigid and their damping behaviour was not influenced by the water. On the other hand, both maxgraft® and Puros® had a strong increase in their molecular mobility with different damping behaviour profiles during the wet state. A high-speed microscopical imaging system was used to analyze the hydrophilicity in several naturally derived (cerabone®, Bio-Oss®, NuOss®, SIC® nature graft) and synthetic DBGS granules (maxresorb®, BoneCeramic®, NanoBone®, Ceros®). The highest level of hydrophilicity was detected in cerabone® and maxresorb®, while Bio-Oss® and BoneCeramic® had the lowest level of hydrophilicity among both naturally derived and synthetic DBGS groups. Deviations among the DBGS were also addressed via physicochemical differences recorded by Micro Computed Tomography, Scanning Electron Microscopy, Fourier Transform Infrared Spectroscopy, X-ray powder Diffractometry, and Thermogravimetric Analysis. Such DBGS variations could influence the volume stability at the grafting site, handling as well as the speed of vascularization and bone regeneration. Therefore, this study initiates a new insight into the DBGS differences and their importance for successful clinical results.
The formation and properties of laser-induced periodic surface structures (LIPSS) were investigated on carbon fibers under irradiation of fs-laser pulses characterized by a pulse duration τ = 300 fs and a laser wavelength λ = 1025 nm. The LIPSS were fabricated in an air environment at normal incidence with different values of the laser peak fluence and number of pulses per spot. The morphology of the generated structures was characterized by using scanning electron microscopy, atomic force microscopy and Fast-Fourier transform analyses. Moreover, the material structure and the surface chemistry of the carbon fibers before and after laser irradiation was analyzed by micro Raman spectroscopy and X-ray photoelectron spectroscopy. Large areas in the cm2 range of carbon fiber arrangements were successfully processed with homogenously distributed high- and low-spatial frequency LIPSS. Beyond those distinct nanostructures, hybrid structures were realized for the very first time by a superposition of both types of LIPSS in a two-step process. The findings facilitate the fabrication of tailored LIPSS-based surface structures on carbon fibers that could be of particular interest for e.g. fiber reinforced polymers and concretes.
Metal-Assisted and Solvent-Mediated Synthesis of Two-Dimensional Triazine Structures on Gram Scale
(2020)
Covalent triazine frameworks are an emerging material class that have shown promising performance for a range of applications. In this work, we report on a metal-assisted and solvent-mediated reaction between calcium carbide and cyanuric chloride, as cheap and commercially available precursors, to synthesize two-dimensional triazine structures (2DTSs). The reaction between the solvent, dimethylformamide, and cyanuric chloride was promoted by calcium carbide and resulted in dimethylamino-s-triazine intermediates, which in turn undergo nucleophilic substitutions. This reaction was directed into two dimensions by calcium ions derived from calcium carbide and induced the formation of 2DTSs. The role of calcium ions to direct the two-dimensionality of the final structure was simulated using DFT and further proven by synthesizing molecular intermediates. The water content of the reaction medium was found to be a crucial factor that affected the structure of the products dramatically. While 2DTSs were obtained under anhydrous conditions, a mixture of graphitic material/2DTSs or only graphitic material (GM) was obtained in aqueous solutions. Due to the straightforward and gram-scale synthesis of 2DTSs, as well as their photothermal and photodynamic properties, they are promising materials for a wide range of future applications, including bacteria and virus incapacitation.
Formalin-fixed paraffin-embedded (FFPE) specimen from biopsy materials are a widespread sample format for pathologists and medical researchers. Pathologists are archiving vast numbers of FFPE samples which can be stored for decades. Conventional immunohistochemical staining (IHC) of biomarkers on FFPE tissue sections is one of the most important analytical techniques for cancer diagnosis and pathology in general. However standardization for IHC samples and quality management is tedious and differs significantly from clinic to clinic. Combining established IHC staining strategies with modern mass spectrometry mediated methods would increase it`s potential and enable access of large FFPE archives for multiplexed quantitation purposes. In this work element mass spectrometry and a new ink-jet printed internal standardization approach was successfully combined with IHC staining to facilitate quantitative multiplex assays for archived FFPE samples. The printing strategy improves elemental image resolution and reproducibility of paraffin embedded breast cancer tissue sections in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) using conventional IHC staining as a model system to investigate the new capabilities of this technique. For the internal standardization we applied a conventional CD-ink-jet printer to print a metal spiked ink onto the top of thin layer tissue sections with constant density. Printing was carried out in a direct comparison to an iodination of the tissue section as previously described as an alternative standardization method. The use of the printed internal standard allowed correction of the fluctuation during the laser ablation process and compensated instrumental drift effects. Mediated by the ink correction approach we achieved better signal-to-background-ratios (SBR) of 74 and better spatial resolution of 30 µm compared to iodination (SBR=23). This improved performance was demonstrated on tumorous areas in FFPE breast cancer tissue sections and allowing detection of Her-2 in tumorous areas of this tissue with significantly improved contrast.
Objectives. There is concern that the integrity of fiberglass dental posts may be affected by chairside trimming during treatment. We hypothesize that hard X-ray methods of phase contrast-enhanced micro-CT (PCE-CT) and synchrotron based X-ray refraction (SXRR) can reliably identify and help characterize the extent of damage.
Methods. Fiberglass posts were imaged both as manufactured and following trimming with a diamond bur. Each of the posts was imaged by SXRR and by PCE-CT. Datasets from PCE-CT were used to visualize and quantify 2D and 3D morphological characteristics of intact and of damage-affected regions caused by trimming. Results. The SXRR images revealed fiber inhomogeneities from manufacturing with a significant increase in internal surfaces in sample regions corresponding to damage from trimming. PCE-CT volumes unveiled the micromorphology of single fibers in the posts and some damage in the trimmed area (e.g. fractures, splinters and cracks). Area, perimeter, circularity, roundness, volume and thickness of the glass fibers in the trimmed area were statistically different from the control (p < 0.01).
Significance. The integrity of single fibers in the post is critical for bending resistance and for long-term adhesion to the cement in the root canals. Damage to the fibers causes substantial structural weakening across the post diameter. Glass fragments produced due to contact with the dental bur may separate from the post and may significantly reduce bond capacity. The above mentioned synchrotron-based imaging techniques can further facilitate assessment of the structural integrity and the appearance of defects in posts (e.g. after mechanical load).
Detection of suspended nanoparticles with near-ambient pressure x-ray photoelectron spectroscopy
(2017)
Two systems of suspended nanoparticles have been studied with near-ambient pressure x-ray photoelectron spectroscopy: silver nanoparticles in water and strontium fluoride—calcium fluoride core-shell nanoparticles in ethylene glycol. The corresponding dry samples were measured under ultra high vacuum for comparison. The results obtained under near-ambient pressure were overall comparable to those obtained under ultra high vacuum, although measuring silver nanoparticles in water requires a high pass energy and a long acquisition time. A shift towards higher binding energies was found for the silver nanoparticles in aqueous Suspension compared to the corresponding dry sample, which can be assigned to a change of surface potential at the water-nanoparticle interface. The shell-thickness of the core-shell nanoparticles was estimated based on simulated spectra from the National Institute of Standards and Technology database for simulation of electron spectra for surface analysis. With the instrumental set-up presented in this paper, nanoparticle suspensions in a suitable Container can be directly inserted into the analysis chamber and measured without prior sample preparation.
In this contribution a Raman spectrometer based control structure for the heating of a desorption column is proposed. For this purpose calibration experiments for the absorption of carbon dioxide using monoethanolamine solutions are carried out and calibration models are developed to measure both carbon dioxide liquid loads and monoethanolamine mass fractions. The calibration experiments are supported by online NMR spectroscopy to accurately measure the appearance of all species in the electrolyte system. Both models are tested during the plant operation of a mini-plant for the oxidative coupling of methane and the proof of concept for the control structure is given. The Raman spectroscopy implemented in the ATEX conform mini-plant shows a reliable and robust performance being even indifferent to impurities hindering the GC analysis.
Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge).
Bauprodukte, die in Innenräumen verwendet werden, sollten die Gesundheit und das Wohlbefinden der Personen die sich darin aufhalten nicht durch das Ausdünsten von Geruchsstoffen stören. Die DIN ISO 16000-28 „Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ (DIN ISO 16000-28) beschreibt umfassend die Möglichkeiten der Geruchsprüfung. In Verbindung mit der Anwendung der VDI-Richtlinie 4302 Blatt 1 „Geruchsprüfung von Innenraumluft und Emissionen aus Innenraummaterialien“ (VDI 4302 Blatt 1) ist sie zur Bewertung der empfundenen Intensität von Bauprodukten mit Vergleichsmaßstab geeignet (Umweltbundesamt 2015). In einem vom Umweltbundesamt (UBA) geförderten Forschungsprojekt der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) und der Bundesanstalt für Materialforschung und –prüfung (BAM) wurden erstmals verschiedene Vergleichsmaßstäbe miteinander verglichen. Ziel des derzeitigen Folgeprojektes ist nun, Mindestanforderungen an Vergleichsmaßstäbe zu erarbeiten, welche die Reproduzierbarkeit der Ergebnisse erhöhen und mit denen die Norm konkretisiert werden kann. Dieser Beitrag stellt die Untersuchungen und Ergebnisse des ersten Projektes und die Schlussfolgerungen für die Durchführung des zweiten Projektes dar.
Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt.
Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes.
Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020.
In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation
method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results.
Determination of short carbon fiber orientation in zirconium diboride ceramic matrix composites
(2024)
In fiber-reinforced components, the fiber alignment and orientation have paramount influence on the thermomechanical properties of the resulting composite, for both short and continuous fiber. Here we present the case of an ultra-refractory matrix intended for extreme environment applications, ZrB2, reinforced with 20 vol% and 50 vol% short carbon fibers. In both cases, fibers tend to align perpendicular to the uniaxial pressure applied during shaping and sintering of a pellet, although the fiber tilt across the pellet thickness is difficult to determine. Moreover, for high volume fractions of reinforcement, the spatial distribution of the fibers is heterogeneous and tends to have domains of preferential orientations. We compare the information on the fiber distribution as collected by scanning electron microscopy images, X-ray computed tomography and synchrotron X-ray refraction radiography (SXRR). The three techniques prove to be complementary. Importantly, we demonstrate that SXRR yields the most statistically significant information due to the largest field of view, yet with a sensitivity down to the nanometer, and that can be successfully applied also to heavy matrix materials, such as zirconium boride.
Im Rahmen des BMBF-geförderten Forschungsprojekts ReMin – REALight werden in einem Projektteam aus Industriepartnern und Forschungseinrichtungen unter Koordination der Bauhaus-Universität Weimar leichte Gesteinskörnungen aus Bau- und Abbruchabfällen und industriellen Nebenprodukten auf thermischem Weg hergestellt. Die Aufgabe der Bundesanstalt für Materialforschung und -prüfung (BAM) ist es, diese im Drehrohrofen erzeugten Blähgranulate für gebundene Anwendungen in Beton und Mörtel umfassend zu charakterisieren. Gemeinsam mit der Opus Denkmalpflege GmbH wird die Applikation feiner, gebrochener Blähgranulate in leichten Steinergänzungsmörteln für die Restaurierung von Sandsteinobjekten untersucht. Hierzu wird ein zweischichtiges Mörtelsystem bestehend aus einem Füll- und einem Deckmörtel entwickelt. Erste Ergebnisse der Rezepturentwicklung verschiedener kalkhaltiger Leichtmörtel mit gebrochenen Blähgranulaten werden vorgestellt. Die neuen Leichtmörtel sind hinsichtlich der entwickelten Druckfestigkeit gleichwertig gegenüber herkömmlichen Restauriermörteln.
Heterogeneous construction and demolition waste can be used as raw material to produce lightweight aggregates (LWA) similar to expanded clays. In the joint research project “REALight”, LWA were produced from masonry rubble in a thermal expanding process using a pilot production plant with a rotary kiln. Our research focuses on the characterisation of the novel LWA and their use in different hydraulically bound applications.
Infra-lightweight concrete (ILC) was produced with the novel LWA, which accounts for two thirds of total aggregate volume, and Celitement, which is a hydraulic binder with a low carbon footprint. Its dry bulk density is ≤ 800 kg/m³. Strength and durability properties are comparable to ILC data from the literature.
Lime-based repair mortars (LRM) containing LWA are beneficial for sandstone conservation due to their similar properties regarding porosity, water absorption and strength. A two-layer repair mortar system, which consists of a filling mortar to fill large voids and a covering mortar to modulate the surface texture to the historic sandstone, was developed.
In our contribution, we present results of the LWA characterisation according to the European standard EN 13055:2016. Requirements and challenges of the use of the novel LWA in ILC and LRM are discussed.
Comparative study of the co-assembly behaviour of 3-chloro-4-hydroxy-phenylazo dyes with DTAB
(2023)
The co-assembly of three one-fold negatively charged 3-chloro-4-hydroxy-phenylazo dyes (Yellow, Blue and Red) with the cationic surfactant dodecyltrimethylammoniumbromide (DTAB) was studied to probe dye–DTAB binding stoichiometry and assembly morphology. For each dye, phase separation was observed above a given dye : DTAB ratio with the ratio depending on the dye. While Yellow and DTAB showed liquid/liquid phase separation above Yellow : DTAB = 1 : 1.67, crystalline dye–DTAB complexes were observed for Blue–DTAB and Red–DTAB above Blue : DTAB = 1 : 2.56 and Red : DTAB = 1 : 2.94 respecively. In homogeneous solution, UV/vis spectroscopic investigations suggest stochiometries of Yellow : DTAB = 1 : 2, Blue : DTAB = 1 : 3 and Red : DTAB = 1 : 4. It was concluded, that Yellow exhibits the highest dye : DTAB binding stoichiometry in both, dye–surfactant complexes in the 2-phase region and in solution, whereas the lowest dye : DTAB binding stoichiometry was observed for Red–DTAB in both cases. The observed stoichiometries are inversely correlated to the impact dye addition has on the morphology of DTAB micelles. Generally, addition of dye to DTAB micelles leads to a reduction in spontaneous curvature of these micelles and to the formation of triaxial ellipsoidal or cylindrical micelles from oblate ellipsoidal DTAB micelles. At a DTAB concentration of 30 mM and a dye concentration of 5 mM, this effect was most pronounced for Red and least pronounced for Yellow, whilst Blue showed an intermediate effect.
VOC-emissions and their odours from building products and furnishings present indoors should not have an impact on personal well-being or health. Odours can be measured by applying the standard ISO 16000-28. Indoor air determination of odour emissions from building products using test chambers. One of the described procedures is the assessment of perceived intensity using a comparative scale by a group of panellists. In this paper, the perceived intensity sampling procedure and its evaluation method are investigated and shown to need improvement. New technical developments in the methodology used to increase the reproducibility of measurement results are discussed. Since odour tests are used for labelling, they have a major influence on the assessment of construction products, similar to the procedure of the German Committee for Health Evaluation of Building Products (AgBB). In the original ISO standard, the evaluation is typically performed using a sampling container separated from the emission chamber. For a better sample presentation, an adapter was developed to connect the emission test chamber to the evaluation funnel and thus enable an odour assessment which is comparable to a direct measurement. The investigations show that losses of odourous substances can be greatly reduced, which is very desirable when seeking to obtain reliable results in odour measurement. Another experimental series was carried out to reduce the measurement effort in the evaluation of perceived intensity. Application of the developed greater than or less than/equal to. query could be helpful here. The results show that the query mostly leads to the same result as the evaluation of the perceived intensity using the method according to the standard but is much easier to perform. Overall, the results can contribute to improving the acceptance of the evaluation of perceived intensity using ISO 16000-28 and to determining odours from building materials increasingly more precisely.
Healthy and energy efficient buildings must be free from disturbing odours. Odour emissions from building materials can be measured with the well-known and accepted standard ISO 16000-28 “Indoor air – Part 28: Determination of odour emissions from building products using test chambers”. For commonly used emission test chambers the sample air is collected in containers (bags) and presented to a group of panel members for the purpose of evaluating the odour. A standard sets requirements for the on-demand presentation in detail. These include the validation procedure for container materials, pre-treatment of bags, details on storage of filled bags and how to carry out the measurements. However, although these measures are proven in practice, incorrect measurements are still possible. Also errors can occur due to a very complex measurement procedure. So, there is a great need for research into how the odour samples are presented.
The proposal planned to be presented will introduce a new development in sample provision by using an adapter which enables collection and provision of sample air without storage or transport of bags. The adapter is a sample container which is permanently positioned on the emission test chamber´s outlet and continuously filled with sample air flowing through it. The flow is briefly interrupted at the time when a sample is taken by a panel member for the test.
The size of the container is sufficient to provide enough sample air for evaluation by at least one panel member via a funnel. Since sampling and presentation are technically connected, it means you can almost do away with storage or transportation and thus it can be presented almost unchanged to the panelmembers. The aim is to reduce measurement errors in the odour samples provision process and the improvement of measurement reproducibility. The paper presents the construction of the adapter as well as the results of emission and odour tests carried out so far.
Menschen, die in der gemäßigten Klimazone leben, verbringen bis zu 90% ihres Lebens in Innenräumen. Deshalb hat das Innenraumklima eine sehr große Bedeutung für deren Wohlergehen, Gesundheit und Leistungsfähigkeit. In Deutschland wird ca. 40% der eingesetzten Primärenergie für das Heizen, Kühlen und Klimatisieren der Innenräume verwendet.
Das Forschungsvorhaben hat eine Laufzeit vom Oktober 2013 bis März 2017. Es wird in Kooperation mit der Bundesanstalt für Materialforschung und –prüfung (BAM) und der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) durchgeführt. Die HTW Berlin koordiniert das Projekt. Die Rheinisch-Westfälische Technische Hochschule Aachen (RWTH) wird teilweise über einen Auftrag in das Projekt integriert.
Ziel des Projektes ist es Baustoffe auf ihre Geruchsemissionen zu untersuchen, um Bauprodukte mit niedrigen Emissionen und Gerüchen identifizieren zu können. Den Verbraucherinnen und Verbrauchern wird somit die Möglichkeit gegeben emissions- und geruchsarme Baustoffe zu wählen.
Die Aufgabenstellung des Projektes ist nachfolgend aufgeführt:
Arbeitspaket 1: Geruchsmessung bei Produkten mit dem Blauen Engel (siehe Kapitel 4 und 5);
Arbeitspaket 2: Untersuchung von Vergleichsmaßstäben (siehe Kapitel 6);
Arbeitspaket 3: Untersuchung der Linearität der Acetonskala (siehe Kapitel 7);
Arbeitspaket 4: Erstellung einer Produktdatenbank (siehe Kapitel 8).
Die Geruchsuntersuchung ist in den Vergabekriterien für den „Blauen Engel“ für textile Bodenbeläge (RAL UZ-128) eingebunden worden. Aus den weiteren Untersuchungen sind für die Normung wichtige Erkenntnisse erarbeitet worden.
Bauprodukte und Einrichtungsgegenstände für Innenräume, wie Bodenbeläge und Wandpaneele, sollen das Wohlbefinden und die Gesundheit der Raumnutzerinnen und -nutzer nicht durch das Ausdünsten von Geruchsstoffen stören. Mit der Geruchsprüfung nach ISO 16000-28 „Innenraumluft - Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ wird der Produktgeruch zu einer messbaren Größe. So kann z. B. die empfundene Intensität, also die Stärke eines Geruchseindruckes, mit Hilfe eines Vergleichsmaßstabes von Probandinnen und Probanden ermittelt werden. Im hier vorgestellten Projekt werden Vorschläge zur Weiterentwicklung der Methode vorgestellt, um im Ergebnis die Reproduzierbarkeit der Messergebnisse weiter zu verbessern. Dabei werden vor allem das Probenpräsentationssystem und die Bewertungsmethodik für die empfundene Intensität bei der Bewertung von Bauprodukten gemäß AgBB-Schema betrachtet, da diese einen wesentlichen Einfluss haben.
Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed.
TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance.
The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation.
Die Abtrennung von CO2 aus industriellen Gasströmen ist eine großtechnisch wichtige Trennaufgabe. Neben der Aufarbeitung von Erdgas werden diese Verfahren zur Verminderung der CO2-Emission durch industrielle Rauchgase, insbesondere für alternativlose Prozesse wie die Stahl- und Zementproduktion diskutiert.
The fluorolytic sol–gel synthesis is applied with the intention to obtain two different types of core–shell nanoparticles, namely, SrF2–CaF2 and CaF2–SrF2. In two separate fluorination steps for core and shell formation, the corresponding metal lactates are reacted with anhydrous HF in ethylene glycol. Scanning transmission electron microscopy (STEM) and dynamic light scattering (DLS) confirm the formation of particles with mean dimensions between 6.4 and 11.5 nm. The overall chemical composition of the particles during the different reaction steps is monitored by quantitative Al Kα excitation X-ray photoelectron spectroscopy (XPS). Here, the formation of stoichiometric metal fluorides (MF2) is confirmed, both for the core and the final core–shell particles. Furthermore, an in-depth analysis by synchrotron radiation XPS (SR-XPS) with tunable excitation energy is performed to confirm the core–Shell character of the nanoparticles. Additionally, Ca2p/Sr3d XPS intensity ratio in-Depth profiles are simulated using the software Simulation of Electron Spectra for Surface Analysis (SESSA). In principle, core–shell like particle morphologies are formed but without a sharp interface between calcium and strontium containing phases.
Surprisingly, the in-depth chemical distribution of the two types of nanoparticles is equal within the error of the experiment. Both comprise a SrF2-rich core domain and CaF2-rich shell domain with an intermixing zone between them. Consequently, the internal morphology of the final nanoparticles seems to be independent from the synthesis chronology.
Gated detection with intensified detectors, e.g., ICCDs, is today the accepted approach for detection of plasma emission in laser-induced breakdown spectroscopy (LIBS). However, these systems are more cost-intensive and less robust than nonintensified CCDs. The objective of this paper is to compare, both theoretically and experimentally, the performance of an intensified (ICCD) and nonintensified (CCD) detectors for detection of plasma emission in LIBS. The CCD is used in combination with a mechanical chopper, which blocks the early continuum radiation from the plasma. The detectors are attached sequentially to an echelle spectrometer under the same experimental conditions. The laser plasma is induced on a series of steel samples under atmospheric conditions. Our results indicate that there is no substantial difference in the performance of the CCD and ICCD. Signal-to-noise ratios and limits of detection achieved with the CCD for Si, Ni, Cr, Mo, Cu, and V in steel are comparable or even better than those obtained with the ICCD. This result is further confirmed by simulation of the plasma emission signal and the corresponding response of the detectors in the limit of quantum (photon) noise.
Im ersten Teil dieses Aufsatzes wurde gezeigt, dass nur ein Teil der für den Deponiebau wesentlichen technischen Eigenschaften in den europäisch harmonisierten Bauproduktnormen DIN EN 13252 und DIN EN 13257, die der CE-Kennzeichnung der Geotextilien (GTX) und geotextilverwandten Produkte (GTP) zugrunde liegen, erfasst werden. Um eine im Wesentlichen vorhandene Gleichwertigkeit der Produkteigenschaften überhaupt abwägen zu können, müssen aber sämtliche relevanten Eigenschaften bekannt sein. Dies erfordert für CE-gekennzeichnete Produkte zusätzliche Prüfungen auf der Grundlage der DepV-Liste der Kriterien und Einwirkmechanismen (Anhang 1, Nummer 2.1.1, DepV). In diesem Teil werden die Tabellen C1 und C2 sowie die Tabelle D aus dem ersten Teil, in denen die Eigenschaften der harmonisierten europäischen Normen (hEN) den Anforderungen der DepV gegenübergestellt wurden, in technischer Hinsicht näher erläutert.
In absehbarer Zeit werden CE-gekennzeichnete Geovliesstoffe, Geogewebe, geosynthetische Dränelemente und Geogitter aus Kunststoff erhältlich sein, bei denen die CE-Leistungserklärung den Hinweis enthält 'dauerhaft für bis zu 100 Jahre' oder sogar 'dauerhaft für mindestens 100 Jahre'. Hersteller, Bauherren, Planer und zuständige Behörden werden sich daher die Frage stellen, ob diese Produkte auf der Grundlage von Anhang 1 Nummer 2.1 Satz 7 Ziffer 1 der Deponieverordnung (DepV) im Deponiebau auch ohne Zulassung verwendet werden dürfen. Ein Vergleich der europäisch harmonisierten Bauproduktnormen DIN EN 13252 und DIN EN 13257, die der CE-Kennzeichnung der Geotextilien und geotextilverwandten Produkte zugrunde liegen, mit den Anforderungen der DepV zeigt nun aber, dass nur ein Teil der für den Deponiebau wesentlichen technischen Eigenschaften in diesen Normen erfasst werden. Daher sind für CE gekennzeichnete Produkte zusätzliche Prüfungen auf der Grundlage der DepV-Liste der Kriterien und Einwirkmechanismen erforderlich. Die in den Produktnormen beschriebene Qualitätssicherung ist nach Anhang 1 Nummer 2 Satz 14 ff der DepV ebenfalls für die Gleichwertigkeit nicht ausreichend. Eine CE-Kennzeichnung ist deshalb noch kein Nachweis, dass die Produkte dem Stand der Technik nach der DepV entsprechen und die Eigenschaften der Produkte den geforderten Eigenschaften im Wesentlichen gleichwertig sind, auch wenn mit Bezug auf den Anhang B der genannten Normen deren Dauerhaftigkeit für 100 Jahre vom Hersteller deklariert wird.----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
In the near future, CE-marked woven and nonwoven geotextiles, geocomposite drains and geogrids will be available on the market, whose declaration of performance will contain the qualification 'predicted service life up to 100 years' or even 'predicted service life minimum 100 years'. Manufacturer, principals and their design engineers as well as the responsible authorities will have to deal with the question, whether such products can be used on the basis of Annex 1, no. 2.1, sentence 7, cipher 1 of the German landfill ordinance (DepV) as components of landfill liner and capping systems. A comparison of the harmonized European standards hEN 13252 and 13257, on which the CE-marking of geotextiles and geotextile-related products is based, with the DepV, shows that only a few of the essential technical characteristics actually relevant for landfill constructions are considered in these standards. Therefore, additional tests based on the DepV-list of criteria and mechanisms of action are necessary for CE-marked products. Requirements on quality managements in the hEN are likewise not adequate for essential equivalence with respect to annex 1, No. 2.1, sentence 14 ff, DepV. Therefore, CE-marking is actually no proof of the fulfilment of the state of the techno logy according to the DepV and of the essential equivalence of product properties to the required properties, albeit the declaration of performance indicates a predicted service life of 100 years.
Analyser-based imaging expands the performance of X-ray imaging by utilizing not only the absorption properties of X-rays but also the refraction and scatter rejection (extinction) properties. In this study, analyser-based computed tomography has been implemented on imaging an articular cartilage sample, depicting substructural variations, without overlay, at a pixel resolution of 3.6 µm.
Der Einsatz von nichtrostenden Duplexstählen im Bauwesen findet in den letzten Jahren zu-nehmende Verbreitung. Insbesondere die Lean-Duplexstähle sind aufgrund geringerer not-wendiger Legierungszuschläge von Nickel und Molybdän eine kostengünstigere Alternative zu den jahrzehntelang etablierten austenitischen Stahlsorten. Verschiedene Korrosionsuntersu-chungen an der BAM sowie Erfahrungen aus der Anwendung konnten nachweisen, dass Lean-Duplexstähle unter verschiedenen Einsatzbedingungen ein vergleichbar gutes, in man-chen Fällen sogar besseres Korrosionsverhalten aufweisen als austenitische Referenzwerkstoffe der gleichen Korrosionswiderstandsklasse. Im Hinblick auf die technisch-mechanischen Eigenschaften konnten von der Fa. Modersohn initiierte Untersuchungen zeigen, dass unter Beachtung der gefügebedingten Einsatzgrenzen eine gute Verarbeitbarkeit und mechanische Sicherheit bei gleichzeitiger Materialeinsparung gewährleistet werden kann. Die positiven Ver-suchsergebnisse haben wesentlich zur Akzeptanz und einer damit einhergehenden Erweiterung der Einsatzgebiete dieser alternativen Werkstoffe im Bauwesen beigetragen.
The stress-induced tetragonal to monoclinic (t-m) zirconia phase transformation can provide a certain degree of plasticity to Ceria-stabilized (Ce-TZP) zirconia-based composites. Characterizing and monitoring this phase transition on a millimeter-size range, within the bulk and in-situ remains a challenge. In this work, the mechanical behavior of Ce-TZP based composite was studied in tension, combining microscopy and synchrotron Xray refraction techniques. In contrast with microscopy methods, which only provide surface information, X-ray refraction radiography (SXRR) allowed the visualization of all the transformation bands, over the entire length and thickness of tested specimens, opening up new avenues for in-situ stress-induced t-m transformation studies.
Oral bioavailability of cyclosporine: Solid lipid nanoparticles (SLN®) versus drug nanocrystals
(2006)
For the development of an optimized oral formulation for cyclosporine A, 2% of this drug has been formulated in solid lipid nanoparticles (SLN, mean size 157 nm) and as nanocrystals (mean size 962 nm). The encapsulation rate of SLN was found to be 96.1%. Nanocrystals are composed of 100% of drug. For the assessment of the pharmacokinetic parameters the developed formulations have been administered via oral route to three young pigs. Comparison studies with a commercial Sandimmun Neoral/Optoral® used as reference have been performed. The blood profiles observed after oral administration of the commercial microemulsion Sandimmun® revealed a fast absorption of drug leading to the observation of a plasma peak above 1000 ng/ml within the first 2 h. For drug nanocrystals most of the blood concentrations were in the range between 30 and 70 ng/ml over a period of 14 h. These values were very low, showing huge differences between the measuring time points and between the tested animals. On the contrary, administration of cyclosporine-loaded SLN led to a mean plasma profile with almost similarly low variations in comparison to the reference microemulsion, however with no initial blood peak as observed with the Sandimmun Neoral/Optoral®. Comparing the area under the curves (AUC) obtained with the tested animals it could be stated that the SLN formulation avoids side effects by lacking blood concentrations higher than 1000 ng/ml. In this study it has been proved that using SLN as a drug carrier for oral administration of cyclosporine A a low variation in bioavailability of the drug and simultaneously avoiding the plasma peak typical of the first Sandimmun® formulation can be achieved.
Solid lipid nanoparticles (SLN) were produced loaded with cyclosporine A in order to develop an improved oral formulation. In this study, the particles were characterized with regard to the structure of the lipid particle matrix, being a determining factor for mode of drug incorporation and drug release. Differential scanning calorimetry (DSC) and wide-angle X-ray scattering (WAXS) measurements were employed for the analysis of the polymorphic modifications and mode of drug incorporation. Particles were produced using Imwitor®900 as lipid matrix (the suspension consisted of 10% particles, 8% Imwitor®900, 2% cyclosporine A), 2.5% Tagat S, 0.5% sodium cholate and 87% water. DSC and WAXS were used to analyse bulk lipid, bulk drug, drug incorporated in the bulk and unloaded and drug-loaded SLN dispersions. The processing of the bulk lipid into nanoparticles was accompanied by a polymorphic transformation from the ß to the α-modification. After production, the drug-free SLN dispersions converted back to ß-modification, while the drug-loaded SLN stayed primarily in α-modification. After incorporation of cyclosporine A into SLN, the peptide lost its crystalline character. Based on WAXS data, it could be concluded that cyclosporine is molecularly dispersed in between the fatty acid chains of the liquid-crystalline α-modification fraction of the loaded SLN.