Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (21)
- Zeitschriftenartikel (13)
- Beitrag zu einem Sammelband (10)
- Posterpräsentation (3)
- Forschungsbericht (3)
- Buchkapitel (1)
- Vortrag (1)
Schlagworte
- Ultrasonic echo (9)
- Radar (7)
- Ultraschallecho (7)
- Concrete (6)
- Non-destructive testing (6)
- SAFT (6)
- Beton (5)
- Reconstruction calculation (4)
- Ultraschall (4)
- Ultraschallecho-Verfahren (4)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
This paper presents the progress of successful location of grouting faults in tendon ducts with ultrasonic imaging. The examples were obtained in the research group FOR 384 funded by DFG (German Research Foundation). The co-operation of experimental research and modeling allowed imaging and identification of grouted and ungrouted areas of tendon ducts (including strands) in a large test specimen (40 m²). In addition to the criteria for indicating grouting faults in post-tensioned ducts known until now the phase evaluation of reflected ultrasonic pulses is described. Experiments and modeling of wave propagation are presented for reflections at metal plates in concrete (thickness range 0.5 mm to 40 mm) and for tendon ducts including strands.
The main part of the progress was achieved by automated measurements using dry contact transducers, 3D-SAFT reconstruction including phase evaluation and modeling considering wave propagation for typical elastic parameters and exact experimental site conditions. The results for shear waves as well as for pressure waves are compared in the frequency range from 50 kHz to 120 kHz.
Characterization of reflector types by phase-sensitive ultrasonic data processing and imaging
(2008)
Ultrasonic and radar imaging techniques are limited in resolution by the wavelength in the material, yet information beyond those limits is hidden in complex frequency dependent reflection coefficients. The analysis of the phase of complex reflection coefficients together with the properties of imaging algorithms can help to characterize and to classify indications of defects in concrete buildings. This paper describes a method to extract phase information from measurements and SAFT reconstructed images. The influencing factors like material properties, transducer characteristics, and imaging algorithms based on Born or Physical Optics approximations are elaborated. Simulated and experimental results are briefly discussed.
Non-destructive and minor destructive testing methods enable a classification of historic structures, building processes, applied building technologies and materials. Therefore, these methods should be part of the global investigation of historic buildings which is usually required before the planning of any building intervention. The case study presented herein encompasses experimental work carried out at the St. Servatius Church in Quedlinburg, Germany. Within a comprehensive restoration campaign, non-destructive on-site investigations were carried out with radar and ultrasonics. The results were combined with plans, views and cores recorded in advance.