Filtern
Erscheinungsjahr
- 2011 (194) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (194) (entfernen)
Sprache
- Englisch (194) (entfernen)
Schlagworte
- CCS (7)
- Corrosion (7)
- Steel (7)
- Concrete (6)
- Strain sensor (6)
- Computed tomography (5)
- Structural health monitoring (5)
- CO2-storage (4)
- Emission (4)
- Fibre optic sensors (4)
Photo-oxidative ageing of polymers under defined exposure (UV, humidity) was investigated from two points of view: a) the ageing process Starts from the topmost surface and penetrates slowly towards bulk and b) radicals play an important role among ageing. Therefore, X-ray photoelectron (XPS) and electron spin resonance (ESR) spectroscopy were applied to show both, the progressive incorporation of oxygen during in-situ UV irradiation (XPS) and the formation of radicals (ESR) in the polymer. The intensity of ESR Signals served as measure for radical concentration. The Validation of this correlation was checked for polyethylenes (PE) equipped with different concentrations of Hostavin N30 UV stabilizer.
The outdoor weathering of polymers is mainly due to UV radiation, water, Pollution, humidity, temperature etc. To understand the effects of weathering, simulated tests need to be undertaken in lab scale. Such tests must be quite efficient and similar to the effects of natural weathering. This paper mainly focuses on the effects of UV radiation along with humidity on LDPE.
This paper presents a sampling strategy for mobile gas sensors. Sampling points are selected using a modified artificial potential field (APF) approach, which balances multiple criteria to direct sensor measurements towards locations of high mean concentration, high concentration variance and areas for which the uncertainty about the gas distribution model is still large. By selecting in each step the most often suggested close-by measurement location, the proposed approach introduces a locality constraint that allows planning suitable paths for mobile gas sensors. Initial results in simulation and in real-world experiments with a gas-sensitive micro-drone demonstrate the suitability of the proposed sampling strategy for gas distribution mapping and its use for gas source localization.
Reinforced concrete piles are used in case of structures that are constructed on soft ground to transfer the loads into deeper strata with sufficient bearing capacity. In order to determine the pile’s behavior and possible damage, static and dynamic pile tests are carried out. Dynamic measurements taken from the pile head can show the bearing behavior and structural integrity by using the theory of wave propagation. In order to receive more precise information about the pile features, now, a string of sensors is embedded at different levels of the pile. A fiber optic strain wave sensor, based on the extrinsic Fabry-Perot interferometer (EFPI), has already been developed and tested in full-scale field tests by Schallert (2010). It was possible to detect the introduced deformation caused by the static load and the dilatational wave during dynamic loading. Although the full-scale tests were successful, the engineering design of the sensor body left room - from the economical point of view - to be optimized. After laboratory tests with the optimized sensor, a cast-in-situ bored pile has been built at the BAM Test Site Technical Safety in Horstwalde, South of Berlin. Additionally to the EFPI sensors, fiber Bragg grating (FBG) sensors, temperature sensors and resistance strain gauge (RSG) sensors are embedded in order to compare the signals with each other. In this paper, the modified sensor and the Setup of the cast-in-situ bored pile along with results of dynamic tests are shown.
The paper presents numerical methods to detect and classify defects and inhomogeneities by means of active thermography. The objective is to determine the wall thickness of structure elements with an inaccessible back wall, for example, of pipes or Containers. As test specimens we used approximately 2 cm thick PVC samples with spatial variations in the back wall geometry. Flash lamps provided the heating. To know the thickness of the wall, we used two inversion methods and compared the results achieved. One is an iterative echo defect shape method and already tested on Steel test specimens with good reconstruction results. The second one is the Levenberg-Marquardt method, applied here to thermographic data for non-destructive testing. Since data capturing using active thermography and the presented numerical methods can easily be automated, the combination of these two procedures is a promising approach providing a broad area of application.
Most of the measurements of temperatures in large pool fires are indirect and present a number of complexities due to the interactions of convection, radiation and soot blockage. In the present work these influences for two organic peroxide [tert-butyl peroxybenzoate (TBPB) and tert-butyl peroxy-2-ethylhexanoate (TBPEH)] pool fires are analysed.
Thermocouple measured temperature in the clear flame zone i.e. combustion zone are found to be 250-400 K lower than from the thermographic measurements. The convective and radiative heat flux contributions from the fire on temperature measurements are discussed. CFD (Computational Fluid Dynamics) simulations have been performed for large pool fires and the predicted time averaged flame temperatures were found to be in qualitative agreement with
measurements due to the stoichiometric combustion model used in the present simulations.
Flame temperature (T), surface emissive power (SEP) of Liquefied Natural Gas (LNG) pool fires (d = 1 m, 6.1 m, 30 m) are investigated by CFD (Computational Fluid Dynamics) simulation and compared with experimental results.
Time averaged flame temperatures of T = 1320 K, T = 1298 K and T = 1281 K are obtained. Surface emissive power (SEP) of 55 kW=m2, 130 kW=m2 and 230 kW=m2 are predicted.
COMSOL Multiphysics® was used as a tool for the better understanding of the evolution of flow patterns during the induced ignition of gases. A simplified model was developed for the scope, by coupling the weakly compressible Navier Stokes module and the convection and conduction module. The current paper presents the results of the performed simulations.
OEMs perceive diamond-like carbon (DLC) coatings as part of a strategy for low frictional tribosystems. Especially the automotive industry anticipates a benefit in applying such coatings in association with the lightweight construction of mechanical parts, for instance in gears and engines. In previous investigations it was shown, that DLC, amorphous carbon (a-C) and tetragonal amorphous carbon (ta-C) coatings can be slip-rolling resistant at least up to ten million load cycles at Hertzian contact pressures P0max of 2.9 GPa lubricated by engine oil at 120°C, Further improvements in load carrying capacity up to P0mean of 2.62 GPa (FN= 5,000 N) were achieved with alternative, available Steel metallurgies as Substrates for thin film coatings. Additional factors, such as influences of the lubrication on the surface chemistry (additives and base oils), wear and friction behavior were investigated.
The use of energetic materials as a main fuel in high temperature process
industries are not known to the scientific community as such. This paper
highlights some of the features and advantages of using organic peroxides
especially di-tert-butyl peroxide (DTBP) in high temperature process industries.
The feasibility of using DTBP as a main or supporting fuel in process industries
have also been justified with the help of Computational Fluid Dynamics (CFD)
simulations. For peroxides requirement of less fuel and air for the same amount
of heat flux has been shown. The resulted emission from the combustion of
DTBP is also discussed.
Infrastructure is subject to continuous ageing. This has given life cycle management of infrastructure an increasing role. Reliable inspection and monitoring tools are therefore an increasing demand. A combination of different non-destructive test methods is often necessary to receive reliable results for material characterization,
flaw detection and the determination of component specific geometry parameters.
Regarding concrete structures thickness measurements are combined with flaw detection and additional information about reinforcement and tendon ducts is required.
Therefore, a multi-sensor measurement approach is necessary with a high degree of automation. Otherwise a time consuming succession of manual measurements has to be performed which would prevent practical applications. A modular control and data acquisition approach is described and the application of two different automated measurement devices is shown. The BetoScan system consists of a self-navigating
mobile robot. The system is especially designed for the investigation of reinforced concrete floors exposed to de-icing salts. The data acquisition of the OSSCAR system a multi-sensor scanner is similar to the robot approach. These different applications are based on a similar kernel allowing the modular use of different contact and noncontact sensors. The described general concept of multi-sensor data acquisition and data analysis presented here is not limited to the field of civil engineering applications.
Combustion of peroxy-fuels
(2011)
The diffusion flames of organic peroxides exhibit quite different characteristics than hydrocarbons. What makes them interesting to study is their fast burning behaviour. As a result the flame temperature enhances and so does the thermal radiation. Due to all these they demand safe handling during processing. However, they can be utilised at several places in different industries where a fuel with fast burning, high temperature and intense radiation are desired. Some of the possibilities to use them as a main or supporting fuel in a wide range of industrial utilities are the major content of this paper.
Integration of magnetic functional components in LTCC Circuit boards calls for co-firing of dielectric and ferrite tapes. Ni-Cu-Zn ferrites with permeability of p=900 were developed which can be fully densified at the Standard LTCC sintering temperature of 900 °C. Successful co-firing of this ferrite with dielectric tapes requires the adaptation of the shrinkage behavior of the materials as well as the thermal expansion during the cooling period - especially in the temperature range below the transformation point of the glassy phase of the dielectric tape. To match these preconditions, a new dielectric LTCC material with steep sintering curve and high thermal expansion coefficient was designed. Sintered multilayer composed of Ni-Cu-Zn ferrite and tailored dielectric tapes are free of cracks and possess no open porosity. No significant interdiffusion between the ferrite and dielectric tapes was found by EDX measurements. Compared to pure ferrite laminates the permeability of co-sintered Ni-Cu-Zn ferrite layers is drastically reduced to 400, i.e. a decrease of more than 50 %.
To investigate the origin of this permeability reduction, Ni-Cu-Zn ferrite laminates were sintered separately, and in combination with alumina release tapes or dielectric tapes, respectively. SEM and EDX analysis of co-fired laminates reveal differences in the ferrite grain growth behavior. Ferrite laminates with homogeneous microstructure and grain size up to 50 pm exhibit large permeability. However, growth of ferrite grains does not take place near the interface between ferrite and release or dielectric tapes. There is a strong correlation between high permeability and volume fraction of large ferrite grains. Regions of fine and coarse grains inside the ferrite layers show different bismuth concentration; the Bi-content is larger in regions of fine ferrite grains.
Structural health monitoring of wind turbine blades by strain measurement and vibration analysis
(2011)
Wind turbine blades have to withstand a high number of load cycles in mostly hard weather conditions over 20 years. In a research project BAM and several partners have designed, evaluated and tested a condition monitoring system for all parts of a wind turbine. At a rotorblade with a length of 58 m fibre bragg grating sensors were applied for in-service strain measurement. Additionally a complex test rig was designed to enable real biaxial loading conditions at a representative test rotor blade to simulate the mechanical loading conditions in the lab. In this test blade with a length of 8 m also fibre bragg grating sensors were implemented to determine their influences for the structure and the condition monitoring system. Vibration measurements were carried out at different test phases. The results were compared with finite element strain and modal analysis.
Neutrons are absorbed particularly by hydrogen containing materials so
they can be used as a tool for visualising heterogeneous density distributions of organic materials. Penetration limits are set by the layer thicknesses and the neutron energies applied. In case of specimens with a flat shape the situation may be encountered that the object only could be penetrated in selected directions. In addition, the overall size may exceed the beam diameter and thus the viewing window if a certain region of interest should be studied by tomography without destroying the integrity of the specimen.
This study shows the capabilities and limits of thermal and fast neutrons to investigate flat wooden specimens such as boards and girders by neutron tomography under such circumstances. Taking projections was impaired either by the limits of penetrability or by the total size of the object. As a consequence, projections were included for reconstruction only from a limited angular range of 90°. It could be shown that an approach based on the slice theorem was capable to visualise structural features along the beam directions while simply omitting the perpendicular ones without causing additional artefacts.
Small samples with a thickness of up to 2 cm but several times broader could be studied with the ANTARES facility of the FRM II neutron source in Garching providing thermal neutrons while larger objects required a beam of higher energy as available in the NECTAR facility of the same institution. The fast (fission) neutrons (1.5 – 2 MeV) of this site allowed investigating an area of interest inside a girder with a cross section of 23.5 x 49 cm². Internal features such as inclusions could be detected as well as a heterogeneous density distribution in glue layers.