Applicability: Odour measurement based on ISO 16000-28 - enhanced determination of indoor air quality

  • Odours might cause offensive nuisance and are under suspicion to be directly harmful to health. Surprisingly their assessment is by definition no part of the determination of indoor air quality (yet). As odours emit from building materials as well as from common consumer goods the users awareness increases continuously and demand for improved consumer protection raises. In comparison to well established methods for the determination of volatile organic compounds (VOC) in the air, there is little experience regarding the applicability, comparability and reproducibility of odour measurements. Considering this, the international and the German standardisation take into account odour assessment, e.g. ISO 16000-28 and VDI 4302-1. In Germany the AgBB-Scheme is a mandatory tool for the evaluation of building products and it is intended to implement odour measurement into it. Initially and essentially the newly developed method had to be put to test involving institutes that deal with VOCOdours might cause offensive nuisance and are under suspicion to be directly harmful to health. Surprisingly their assessment is by definition no part of the determination of indoor air quality (yet). As odours emit from building materials as well as from common consumer goods the users awareness increases continuously and demand for improved consumer protection raises. In comparison to well established methods for the determination of volatile organic compounds (VOC) in the air, there is little experience regarding the applicability, comparability and reproducibility of odour measurements. Considering this, the international and the German standardisation take into account odour assessment, e.g. ISO 16000-28 and VDI 4302-1. In Germany the AgBB-Scheme is a mandatory tool for the evaluation of building products and it is intended to implement odour measurement into it. Initially and essentially the newly developed method had to be put to test involving institutes that deal with VOC measurements. To test the applicability of the method an interlaboratory test was conducted. The results and identified potential improvements are presented in this study (Brosig, 2013).zeige mehrzeige weniger

Volltext Dateien herunterladen

  • HP1079.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Laura Brosig, Wolfgang HornORCiD, Lars Pyza, Oliver Jann
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Indoor Air 2014 - 13th International conference on indoor air quality and climate (Proceedings)
Jahr der Erstveröffentlichung:2014
Erste Seite:HP1079, 1
Letzte Seite:4
Freie Schlagwörter:Building materials; Hedonic tone; Odour measurement; Perceived intensity; VOC
Veranstaltung:Indoor Air 2014 - 13th International conference on indoor air quality and climate
Veranstaltungsort:Hongkong, China
Beginndatum der Veranstaltung:07.07.2014
Enddatum der Veranstaltung:12.07.2014
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:20.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:18.09.2014
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.