• Treffer 10 von 10
Zurück zur Trefferliste

Electrochemiluminescence Based Enzymatic Urea SensorUsing Nanohybrid of Isoluminol-gold Nanoparticle-graphene Oxide Nanoribbons

  • This study evaluates on the possibility of using gold nanoparticles functionalizedwith the luminol derivative N-(aminobutyl)-N-(ethylisoluminol)(ABEI) and hybridizedwith graphene oxidenanoribbons on acarbon based screen-printedelectrode (ABEI-AuNP-GONR/SPE) as an enzymaticelectrochemiluminescence (ECL) urea sensor.The electrocatalytic activity and ECL intensity of ABEI-AuNP-GONR/SPE were found to increase proportionally with the concentrationofurea in the analyte sample,owing to the rise in pH value.These phenomena are attributed to increased formation of luminol monoanion precursors for further electrochemical oxidation,which in turn produce eitherluminol radicals or excited3-amino-phthalate molecules.The luminescence is most likely caused by the interaction of luminol radicals with superoxide radicals formed from dissolved oxygen. Thesensitivity of our sensor was determinedtobe 170.58 mM@1 and 16.23 mM@1 for urea concentrations from 2to5.82 mM and from 5.82 to 30 mM, respectively,This study evaluates on the possibility of using gold nanoparticles functionalizedwith the luminol derivative N-(aminobutyl)-N-(ethylisoluminol)(ABEI) and hybridizedwith graphene oxidenanoribbons on acarbon based screen-printedelectrode (ABEI-AuNP-GONR/SPE) as an enzymaticelectrochemiluminescence (ECL) urea sensor.The electrocatalytic activity and ECL intensity of ABEI-AuNP-GONR/SPE were found to increase proportionally with the concentrationofurea in the analyte sample,owing to the rise in pH value.These phenomena are attributed to increased formation of luminol monoanion precursors for further electrochemical oxidation,which in turn produce eitherluminol radicals or excited3-amino-phthalate molecules.The luminescence is most likely caused by the interaction of luminol radicals with superoxide radicals formed from dissolved oxygen. Thesensitivity of our sensor was determinedtobe 170.58 mM@1 and 16.23 mM@1 for urea concentrations from 2to5.82 mM and from 5.82 to 30 mM, respectively, coveringthe normal urea level in human blood.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Ismail_et_al-2017-Electroanalysis.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:N. S. Ismail, Quynh Hoa Le, T. H. Vu, Yuki Inoue, H. Yoshikawa, M. Saito, E. Tamiya
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Electroanalysis
Jahr der Erstveröffentlichung:2017
Herausgeber (Institution):Osaka University, Japan
Verlag:Wiley-VCH Verlag GmbH & Co. KGaA
Verlagsort:Weinheim
Jahrgang/Band:29
Ausgabe/Heft:4
Erste Seite:938
Letzte Seite:943
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Biosensors; Graphene oxide; Nanomaterials
DOI:10.1002/elan.201600477
URL:http://onlinelibrary.wiley.com/doi/10.1002/elan.201600477
ISSN:1040-0397
ISSN:1521-4109
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:13.07.2017
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:25.08.2017
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.