Refine
Year of publication
Document Type
- Other (112) (remove)
Is part of the Bibliography
- no (112)
Keywords
- Case Study (7)
- Patientenedukation (7)
- Bioökonomie (5)
- Duales Pflegestudium (5)
- Gesetzeskommentar (3)
- Safety-critical systems (3)
- TH Rosenheim, Tag der Forschung 2022 (3)
- Agenda 2030 (2)
- Barrieredeterminanten (2)
- Brustprothese (2)
Institute
- Fakultät für Angewandte Gesundheits- und Sozialwissenschaften (48)
- Fakultät für Holztechnik und Bau (16)
- Fakultät für Informatik (10)
- Fakultät für Ingenieurwissenschaften (8)
- Zentrum für Forschung, Entwicklung und Transfer (4)
- Fakultät für Sozialwissenschaften (3)
- Fakultät für Angewandte Natur- und Geisteswissenschaften (2)
- Fakultät für Chemische Technologie und Wirtschaft (2)
This paper analyses the achievable performance of the orbit prediction for a geostationary satellite using clusters of electrical propulsion (EP) thrusters for station-keeping and a star tracker based attitude control system.
The challenge in the orbit prediction is that the real electrical propulsion thrust is known with limited accuracy only. In combination with thrust pointing errors, these inaccuracies can accumulate to large orbit position errors during long low thrust burn arcs.
The discrepancy between real and predicted satellite position is determined in terms of probability and as a worst case scenario.
Die Erfindung betrifft eine Brustprothese, die aus einem schalenförmigen Körper aus einem weich-elastisch eingestellten Kunststoff besteht, der in Kunststoffolien zu einer oder mehreren Kammern eingeschweißt ist. Erfindungsgemäß wird das Füllmaterial mit polymeren Farbstoffen eingefärbt. Die Erfindung betrifft weiterhin ein Verfahren zum Färben von Brustprothesen.
Agenda:
Studienziel Software-Ingenieur(in) Projekte im Rahmen des Informatik-Studiums Projektbeispiele -IT Partner in Forschungsprojekten
Labor für Software-Technik
-IT Partner in Forschungsprojekten -Einzelanfertigungen für genau einen Kunden -Unterstützung von Startups / Testen von Geschäftsideen -Projekte mit kleinen und mittleren Unternehmen Zusammenarbeit mit FH: Nächste Schritte
Ein Verfahren zur Einbettung von Dekor-Körpern in eine Silikongummi-Matrix umfasst das Auftragen einer ersten aushärtbaren Polysiloxanzusammensetzung auf eine Grundplatte und Angelieren der ersten Polysiloxanzusammensetzung; das Aufbringen der Dekorkörper auf die angelierte erste Polysiloxanzusammensetzung; das Ausfüllen von Zwischenräumen zwischen den Dekorkörpern mit einer zweiten aushärtbaren Polysiloxanzusammensetzung; und das Aushärten der Polysiloxanzusammensetzungen zu einer transparenten Polysiloxan-Matrix mit darin eingebetteten Dekor-Körpern. Ein weiteres Verfahren zur Einbettung von Dekor-Körpern in eine Silikongummi-Matrix umfasst das Auftragen einer aushärtbaren Polysiloxanzusammensetzung auf eine Grundplatte und Aufbringen der Dekor-Körper vor dem Angelieren der ersten Polysiloxanzusammensetzung; das Einsinkenlassen der aufgebrachten Dekor-Körper in die aushärtende Polysiloxanzusammensetzung derart, dass die aufgebrachten Dekor-Körper von der Polysiloxanzusammensetzung vollständig umschlossen werden; und das Aushärten der Polysiloxanzusammensetzungen zu einer transparenten Polysiloxan-Matrix mit den darin eingebetteten Dekor-Körpern derart, dass eine Mehrzahl der eingebetteten Dekor-Körper von der Polysiloxanzusammensetzung vollständig umschlossen bleibt.
Agiles Projektmanagement
(2015)
A method for integrated model-based safety analysis includes integrating a safety analysis model into a system development model of a safety-critical system. The system development model includes model components. The safety analysis model models a failure logic separately for each of the model components. The method includes representing dependencies among the model components with a design structure matrix. The design structure matrix represents each of the model components with a row and a column and shows dependencies between model components with corresponding entries. The method also includes sequencing the design structure matrix, and identifying at least one dependency loop and loop components in the sequenced design structure matrix. The loop components are part of the at least one dependency loop.
A method for automated recertification of a safety critical system with at least one altered functionality is provided. The method includes providing a failure propagation model of the safety critical system. The method also includes updating the failure propagation model of the safety critical system according to the at least one altered functionality using inner port dependency traces between inports and outports of a failure propagation model element representing the at least one altered functionality. The method includes calculating top events of the updated failure propagation model, and comparing the calculated top events with predetermined system requirements to recertify the safety critical system.
An apparatus and method for analyzing availability of a system including subsystems each having at least one failure mode with a corresponding failure effect on the system are provided. The apparatus includes a degraded mode tree generation unit configured to automatically generate a degraded mode tree. The degraded mode tree includes at least one degraded mode element representing a degraded system state of the system that deviates from a normal operation state of the system based on a predetermined generic system meta model stored in a database including Failure Mode and Effects Analysis elements representing subsystems, failure modes, failure effects, and diagnostic measures. The apparatus also includes a processor configured to evaluate the generated degraded mode tree for calculation of the availability of the system.
A method for automated qualification of a safety critical system including a plurality of components is provided. A functional safety behavior of each component is represented by an associated component fault tree element. The method includes automatically performing a failure port mapping of output failure modes to input failure modes of component fault tree elements based on a predetermined generic fault type data model stored in a database.
Informierst du noch - oder lässt du schon mitbestimmen? Ein Stufenmodell partizipativen Arbeitens.
(2017)
Beschichtung für ein medizinisches Instrument, das nach seinem Einführen in einen menschlichen oder tierischen Körper mit dessen Körperflüssigkeit in Kontakt gelangt, umfassend eine Materialzusammensetzung, die wenigstens ein Phosphorylcholin umfassendes Polymer enthält, dadurch gekennzeichnet, dass die Materialzusammensetzung für ein medizinisches Instrument, das auf seiner Oberfläche Polyurethan enthält oder das daraus gänzlich besteht, eine auf das medizinische Instrument aufbringbare Haftungsvernetzungsschicht aus einem chemischen Haftvermittler und einem mit diesem vernetzten Alkohol, mindestens einem zweiwertigen Alkohol mit zwei primären OHGruppen, und das wenigstens eine Phosphorylcholin umfassende Polymer enthält, welches auf der Haftungsvernetzungsschicht als gesonderte Schicht aufgebracht sowie auf dieser und gegebenenfalls mit dieser vernetzt ist.