Refine
Year of publication
- 2018 (11) (remove)
Document Type
- Conference Proceeding (11) (remove)
Is part of the Bibliography
- no (11)
Keywords
We present low-cost, high-efficient electromagnetic coupling between open ring geometry and a so-called butterfly structure on standard printed circuit boards (FR4) for the purpose of short range wireless data and power transfer at an UHF resonance frequency of 868 MHz. The components of the transfer system are characterized by simulation and experiments in terms of associated scattering parameters. Characterizing the efficiency of the coupled resonators, RF signal power transmission is examined for high power transfer as well as for low power DC supply utilizing a voltage doubler rectifier. With an enhanced butterfly structure coupler, unmodulated RF power transmission of 17.3 W is achieved with an efficiency of more than 95%. Furthermore, signal transmission of Pulse-Width-Modulated (PWM) signals with frequencies up to 5 MHz is demonstrated.
Outdoor-I-U-Messungen an Photovoltaik- (PV) - Modulen haben den Vorteil, dass Effekte wie „light soaking“ oder „light-induced degradation“ unter natürlichen Bedingungen untersucht werden können. Solche Outdoor-Analysen können unter Anwendung des Selbstreferenzierungsalgorithmus (SRA) die Zuverlässigkeit von Indoor-Flasher-Messungen erreichen. Dieses neue Konzept liefert I-UEigenschaften für wesentlich mehr Testbedingungen als vom Standard IEC 61853 gefordert und so können Schwachlichtkurven aller relevanten elektrischen I-U-Parameter für bestimmte Temperaturen erzeugt werden. Wir berichten über experimentelle Ergebnisse einer 6-tägigen Outdoor-Messkampagne an Dünnschicht-PV-Modulen. Wir evaluieren darüber hinaus die Möglichkeiten, Temperaturkoeffizienten, STC- und NOCT-Daten zu bestimmen und I-U-Kennlinien als Basis für Fitting-Analysen abzuleiten. Abschließend wird die Genauigkeit der neuen Outdoor-Methode untersucht.
Der Lüftung von Wohnräumen und damit der Versorgung von Menschen mit guter Luftqualität wird immer noch eine relative geringe Bedeutung beigemessen. Das ist umso bemerkenswerter als wir einen Großteil unserer Lebenszeit in geschlossenen Räumen verbringen. Die gültige DIN 1946 Teil 6 regelt zum einen den nutzerun¬abhängigen Luftwechsel zum Feuchteschutz und legt zum andere Planungsvorgaben für einen hygienischen Luftwechsel fest. Die wesentliche Neuerung in dieser Norm aus dem Jahre 2009 war die verpflichtende Sicherstellung des Luftwechsels zum Feuchteschutz ohne Nutzereingriff für jeden Neubau und bei lüftungs¬technisch relevanten Sanierungen. Das Gebäude oder die Wohnung muss diesen Mindestluftwechsel von selbst sicherstellen. Reicht dazu der Infiltrationsluftwechsel durch Leckagen nicht aus, sind geeignete lüftungstech¬nische Maßnahmen zu planen und umzusetzen. Somit wurde für Wohnungen die Erstellung eines Lüftungskonzeptes nötig.
In der überarbeiteten Norm wurde dieses Grund¬prinzip beibehalten. Einige der wesentlichen Änderungen sind:
• Neue Berechnung der Infiltration und der Luft¬volumenströme zur Ermittlung der Notwen¬digkeit einer lüftungstechnischen Maßnahme.
• Bei der Berechnung der Volumenströme werden typische Belegungsdichten der Nut-zungseinheiten berücksichtigt.
• Neuaufnahme und definierte Beschreibung von kombinierten Lüftungssystemen, z.B. Kombinationen aus freier und ventilatorge-stützter Systeme.
Über die Auswirkungen der neuen Berechnungs¬ansätze insbesondere auf die Fensterlüftung berichtet der Vortrag.
Soil nailing systems are a common way to stabilize slopes and construction pits. Their design is usually based on the mechanical equilibrium of a rigid body motion and therefore, only tensile stresses are considered and accompanying forces like bending (shear stresses) in the soil nails are neglected. Continuous strain measurements along nails could verify this assumption, but may not be performed using conventional sensing technologies.
This paper reports about monitoring of a soil nailed slope stabilization using distributed fiber optic sensing. Soil nails in different anchoring horizons were instrumented and autonomously monitored over several weeks, in which the construction pit was excavated continuously. After the excavation, the final load bearing capacity of one selected nail was determined within a classical geotechnical load test. In addition to the field measurements, the bending behavior of the instrumented nail system was analyzed under laboratory conditions.
The presented studies demonstrate the high potential of distributed fiber optic sensing systems and their capability to extend traditional measurement methods in foundation engineering applications.
Electric-current-assisted sintering (ECAS) is a novel process that can potentially replace the conventional sintering method. It is hypothesized that the process can reduce the sintering time and can be used in situ; thus, can be more cost effective. The purpose of this research is to investigate the effect of direct current on the sintered properties of iron-copper powder metal. Experiments were conducted at various conditions to determine the optimal process parameters for this particular powder metal. The parameters investigated were electric current levels and energizing time. Experiments also included sintering the powder using a conventional furnace. Samples from both types of experiments were compared to determine the metallurgical differences due to the sintering process. Mechanical and microstructure examination were conducted to aid in determining the feasibility of ECAS.
Besonders einfache Lüftungssysteme sind heute vor allem in der Sanierung wichtig. In einer Vielzahl von Messreihen hat sich gezeigt, dass das System der zentralen Zulufteinbringung mit Verteilung über aktive Überströmer im Hinblick auf den Schadstoffaufbau und der sich einstellenden Luftqualität ausreichend funktioniert.
The IT architecture for meter reading and utility services is at the core of new business models and has a decisive role as an enabler for resource efficiency measures. The communication architecture used by those services has significant impact on cost, flexibility and speed of new service rollout. This article describes how the dominant system model for meter reading came about, what alternative models exist, and what trade-offs those models have for rollout of new services by different stakeholders. Control of a self learning home automation system by dynamic tariff information (Real-Time-Pricing) is given as an application example.