Energie und Mobilität
Refine
Year of publication
Document Type
- conference proceeding (article) (168)
- Article (143)
- Part of a Book (41)
- conference talk (32)
- Report (19)
- conference proceeding (presentation, abstract) (8)
- Book (7)
- Master's Thesis (4)
- Preprint (4)
- Part of Periodical (3)
Is part of the Bibliography
- no (431)
Keywords
- Energiewende (27)
- Erneuerbare Energien (27)
- Klimaneutralität (22)
- Power-to-Gas (21)
- Sektorenkopplung (16)
- Energiespeicher (14)
- Power-to-X (9)
- Wasserstoff (8)
- Netzplanung (7)
- Blindleistung (6)
Institute
- Fakultät Elektro- und Informationstechnik (240)
- Fakultät Maschinenbau (155)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (76)
- Combustion Engines and Emissions Control Laboratory (CEEC) (40)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energienetze (38)
- Labor Elektrische Maschinen und Antriebstechnik (37)
- Computational Mechanics and Materials Lab (CMM) (20)
- Technologie-Campus Neustadt an der Donau (20)
- Labor Intelligente Materialien und Strukturen (17)
- Fakultät Informatik und Mathematik (15)
- Fakultät Bauingenieurwesen (14)
- Labor Datenkommunikation (12)
- Laboratory for Safe and Secure Systems (LAS3) (12)
- Mechatronics Research Unit (MRU) (11)
- Labor Sorptionsprozesse (10)
- Fakultät Angewandte Natur- und Kulturwissenschaften (9)
- Labor Finite-Elemente-Methode (FEM) (8)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (7)
- Labor Industrielle Elektronik (7)
- IT-Anwenderzentrum (ITZ) (6)
- Institut für Sozialforschung und Technikfolgenabschätzung (IST) (6)
- Labor Empirische Sozialforschung (6)
- FuE-Anwenderzentrum Informations- und Kommunikationstechnologien (IKT) (5)
- Labor Bauphysik (5)
- Labor Optische Übertragungssysteme (5)
- Labor für Technikfolgenabschätzung und Angewandte Ethik (LaTe) (5)
- Regensburg Center of Energy and Resources - RCER (5)
- Labor Heizungs- und Klimatechnik (4)
- Labor Informationssicherheit und Complience (ISC) (3)
- Labor Regelungstechnik (3)
- Labor Elektronik (2)
- Labor für Geotechnik (2)
- Labor Biofluidmechanik (1)
- Labor CAD/CAE (1)
- Labor Mehrkörpersimulation (MKS) (1)
- Labor Mikrosensorik (1)
- Regensburg Center of Biomedical Engineering - RCBE (1)
- Regensburg Center of Health Sciences and Technology - RCHST (1)
Begutachtungsstatus
- peer-reviewed (187)
- begutachtet (15)
Since conventional generation plants provide a considerable share of reactive power but are gradually being shut down due to energy transition, leading to power deficits at the transmission grid level, new concepts for the supply of reactive power must be developed. As one possibility for the latter, industrial plants in the distribution grid are considered suitable, as their reactive power potentials can contribute to voltage maintenance and thus to a grid- or system-serving behavior. In this paper, the determination of reactive power potentials provided by industrial compensation systems (ICS) is presented. An industrial plant in the medium voltage grid, with three installed ICSs, is investigated. The potentials are determined and described based on their time characteristics, which provide information about the occurrence and distribution of inductive and capacitive potentials. A grid simulation of the investigated industrial grid is used to analyze the effects of retrieving the reactive power potentials regarding equipment utilizations and voltage limits.
The provision of reactive power is one option for maintaining the grid voltage, that is defined as an ancillary service in Germany. This paper presents an approach for determining deficient voltage deviation demands within an electrical grid for long term reactive power planning investigations. In contrast to previous approaches, which evaluate the Q-behavior of extended ward elements or grid assets, voltage deviations are analyzed bus-specifically. So further reactive power planning investigations are able to scale and optimize additional reactive power sources directly on planning voltage limits using load flow sensitivity techniques. The focus lies on the analysis of the steady state demand at base case conditions. Therefore, a grid planning process is conceptualized. An optimal power flow algorithm based on Differential Evolution is used for an optimal reactive power dispatch of installed reactive power sources, e. g. reactive power compensation systems or (renewable) energy sources to minimize the total voltage deviation according to voltage limits of Transmission System Operators planning principles. Methodological and processuals specifications as well as an application use case with an exemplary transmission system are presented in this paper.
This work aims at investigating the kinetic mechanisms of the reduction/oxidation (redox) reactions of iron oxide/iron pellets under different operating conditions. The reaction principle is the basis of a thermochemical hydrogen storage system. To simulate the charging phase, a single pellet consisting of iron oxide (90% Fe2O3, 10% stabilising cement) is reduced with different hydrogen (H2) concentrations at temperatures between 600 and 800 °C. The discharge phase is initiated by the oxidation of the previously reduced pellet by water vapour (H2O) at different concentrations in the same temperature range. In both reactions, nitrogen (N2) is used as a carrier gas. The redox reactions have been experimentally measured in a thermogravimetric analyser (TGA) at a flow rate of 250 mL/min. An extensive literature review has been conducted on the existing reactions’ kinetic mechanisms along with their applicability to describe the obtained results. It turned out that the measured kinetic results can be excellently described with the so-called shrinking core model. Using the geometrical contracting sphere reaction mechanism model, the concentration- and temperature-dependent reduction and oxidation rates can be reproduced with a maximum deviation of less than 5%. In contrast to the reduction process, the temperature has a smaller effect on the oxidation reaction kinetics, which is attributed to 71% less activation energy (Ea,Re=56.9 kJ/mol versus Ea,Ox=16.0 kJ/mol). The concentration of the reacting gas showed, however, an opposite trend: namely, to have an almost twofold impact on the oxidation reaction rate constant compared to the reduction rate constant.
Im Projekt MAGGIE wurden für das genossenschaftliche historische Stadtquartier „Margaretenau“ in Regensburg Musterlösungen für energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht.
Dazu wurde ein bestehendes Wohngebäude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus Wärmepumpentechnologie und Kraft- Wärme-Kopplung ausgestattet und untersucht, ergänzt durch eine dynamische Wärmelogistik zur Verringerung von Verteilungsverlusten.
Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems während des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Strombörse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltwärme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Gebäudebetrieb.
Für die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realität getestet. Am Bestandsgebäude kam anstelle eines Wärmedämmverbundsystems ein innovativer Dämmputz mit Mikrohohlglaskugeln zum Einsatz.
Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles über mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete für die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erhöht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird.
Planning Principles for Integrating Community Empowerment into Zero-Net Carbon Transformation
(2023)
The adoption of the UN 2030 Agenda and the Sustainable Development Goals is a landmark in international sustainability politics. For example, Europe has set ambitious targets to achieve 100 climate-neutral and smart cities by 2030. However, numerous case studies from different countries have found that accelerating the transition to net-zero carbon emissions is easily hampered by the lack of a coherent systems framework, and that implementation gaps remain at the community level. These barriers are often due to a lack of an adequate end-user (i.e., household) input and early planning participation. This work therefore aims to improve on conventional planning methods that do not reflect innovative technologies with uncertainty and may not be applicable due to the lack of community empowerment, which is a dynamic learning and intervention opportunity for end-users at different planning stages (i.e., outreach, survey, planning, implementation, management, and maintenance). Using the lessons learned from participatory action research, whereby the author was involved as a project director throughout the planning and design process, we identified a
six-step cycle principle. The steps are (1) collective action commitments, (2) local values and resource identification, (3) carbon footprint inventory, (4) optimized integration of environment, economy, and energy action plans, (5) Flexible strategic energy system plans, and (6) digital performance monitoring. Ultimately, the outcomes provide application support for policymakers and planners and stimulate community engagement to contribute to the achievement of zero net carbon emissions.
The effect of both heat and mass transfer characteristic lengths (HTCL, MTCL) of two different adsorber plate heat exchangers (APHE), for application in an adsorption chiller, on the adsorption and desorption kinetics is investigated. Three representative test frames (TF1-TF3) are prepared to examine small-scale adsorbent samples of the microporous silica gel (Siogel of Oker-Chemie, Germany) applying the volumetric large-temperature-jump methodology at different operating conditions. Based on the obtained kinetic data, an analytical model has been developed to predict the specific cooling power (SCP) and the coefficient of performance (COP) of a single-bed adsorption chiller comprising the studied APHEs. It turned out that, within the tested range of HTCL and MTCL, it can be concluded that, the adsorption kinetics are mainly influenced by the MTCL, while the desorption kinetics are dominated by the HTCL of the adsorbent domain. Applying Siogel as loose pellets inside a newly introduced APHE results in of 423.3 and 182.7 W⋅kg−1, at the evaporator temperatures of 15 °C and 5 °C, respectively. Herein, the condenser and adsorber-end temperatures amount to 30 °C and the desorption-end temperature to 90 °C. The corresponding s amount to 0.50 and 0.40, respectively, which represent quite promising results for further design optimizations.
This paper proposes a multi domain physical model of permanent magnet synchronous machines, considering electrical, magnetic, thermal and mechanical effects. For each component of the model, the main wave as well as lower and higher harmonic wave components of the magnetic flux and the magnetic potential difference may be considered. The permanent magnets are modeled as discrete azimuthal segments in order to consider possible partial demagnetization effects. For each magnet segment a linearized temperature dependent B-H curve is considered. The main advantage of the presented model is that time transient operational behavior of a permanent magnet synchronous machine can be considered under various electrical, magnetic, thermal and mechanical conditions. The electromagnetic condition of surface magnet machine is compared with finite element analysis.
In this work a buck converter model for multidomain simulations is proposed and compared with a state-of-the-art buck converter model. In the proposed model no switching events are calculated. By avoiding the computation of the switching events in power electronic models the processing time of multidomain simulations can be decreased significantly. The proposed model calculates any operation point of the buck converter in continuous inductor current conduction mode (CICM) while considering the conduction losses and switching losses. It is possible to utilize the proposed modeling approach also for other dc-to-dc converter topologies. Laboratory test results for the validation of the proposed model are included.
The paper presents a concept and an implementation of Modelica simulation interaction using the operating system inter-process communication method of the Named Pipe. The main aim of this presented work is to implement a hardware-in-the-loop simulation (HILS) environment based on Dymola which runs on a normal Microsoft Windows Personal Com-puter. An energy storage test bench is connected by an ana-logue and digital data input/output card with the Dymola simulation computer. With this proposed system, particularly long-time simulations with sample rates up to 30 Hz can be executed very cost effective. Typical applications are simulations of drive cycles to test energy storage systems in electrified vehicles such as batteries or fuel cells. Other application ex-amples are the verification of battery models, thermal management models or battery management sys-tem (BMS) models. In this paper all methods used for implementation are described in detail. Especially the concept of inter-process communication and the concept for real-time and simulation time synchronization is discused. An application example which uses the provided concept is also shown at in this paper. In this example a longitudinal simulation of a vehicle is pre-sented. The startup phase of the internal combusting engine model and a short drive cycle in combination with a connected real battery is shown.
This paper deals with a simulative approach for investigating the impact of inverter pulse inhibition during field weakening operation of permanent magnet synchronous machines and asynchronous induction machines. The modelling and simulation language Modelica is used to design models for the vehicle, the electric machine and the inverter in different abstraction levels. It is shown that when using a permanent magnet synchronous machine, a sudden breakdown of the field weakening current causes induction of high voltages in the stator windings. Hence, the electric system of the vehicle has to be protected against the resulting high currents. Furthermore precautions have to be taken to avoid dangerous driving conditions because of high braking torques in an inverter fault operation mode. In the case of the asynchronous induction machine an inverter pulse inhibition poses no big problem, neither for the electric system of the vehicle, nor the driver.
This paper focuses on simulation of permanent magnet synchronous machine (PMSM) with fractional-slot windings (FSW) in Modelica. Modeling of the electrical machines with object-oriented approach is shortly described, and a new Modelica library for simulation of electrical machines is introduced. The results of simulation of PMSMs with fractional slot windings are presented and explained. Special attention is paid to the higher harmonics and subharmonics produced by the winding and their influence on machine operation.
Condition monitoring of rotor problems such as demagnetization and eccentricity in permanent magnet synchronous motors (PMSM) is essential for guaranteeing high motor performance, efficiency, and reliability. However, there are many limitations to the off-line and on-line methods currently used for PMSM rotor quality assessment. In this paper, an inverter-embedded technique for automated detection and classification of PMSM rotor faults is proposed as an alternative. The main concept is to use the inverter to perform a test whenever the motor is stopped, to detect rotor faults independent of operating conditions or load torque oscillations, which is not possible with motor current signature analysis (MCSA). The d-axis is excited with a dc+ac signal, and the variation in the inductance pattern due to the change in the degree of magnetic saturation caused by demagnetization or eccentricity is observed for fault detection. An experimental study on a 7.5kW PMSM verifies that demagnetization and eccentricity can be detected and classified independent of the load with high sensitivity.
Simulation is an indispensable tool for the engineering of systems containing electric drives. Depending on the design phase and the engineering task different levels of modeling details are required: proof of concept; investigation of energy and power consumption; design of control; etc. The new EDrives library provides three levels of abstraction for inverters: quasi static (neglecting electrical transients); averaging (neglecting switching effects) and switching – for serving different demands. The inverters can feed the machine models of the Modelica Standard Library: Modelica.Magnetic.FundamentalWave and the new Modelica.Magnetic.QuasiStatic.FundamentalWave. The EDrives library copes with arbitrary phase numbers and can be easily extended to develop new control algorithms. In this publication the structure of the library and the implemented control principles are presented. Furthermore; examples comparing the three different levels of abstraction are included.
The majority of industrial controlled induction machine drives are connected to the mains via a diode bridge. However; if reduction of harmonic currents and / or regenerative operation is desired; replacing the diode bridge by an active front-end (AFE) is required. This paper describes two models of an AFE: a power balance model disregarding switching effects; and an ideal switching model of a pulse width modulation (PWM) converter. Both models are controlled utilizing space phasors in a voltage oriented reference frame. Voltage oriented control (VOC) of the mains converter can be compared with field oriented control (FOC) of a machine converter. Design and parametrization of the main parts—synchronization with mains voltage; current controller and DC voltage controller—are described in detail. Additionally; simulation results proving the implementation and demonstrating possible investigations as well as an outlook on further enhancements are presented.
Sensorless PM-Drive Aspects
(2010)
The development procedure of permanent magnet drives for sensor less operation beginning from standstill under overload conditions has to consider different design aspects coevally. First, the robust rotor position sensing by test signal enforces a design with a strongly different behavior of the spatial dq-oriented differential inductance values. Therefore, the interior rotor magnet array arrangement is from principle predestinated for the controlled sensor less mode including standstill. Fortunately, in order to reduce costs, the distinct reluctance torque capability of such interior magnet arrangement is additionally used for a significantly increased torque by applying a pre-oriented stator current space vectors within the quasi-steady control.
Two state-of-the-art machine designs are mainly used in recent electric and hybrid electric vehicles: asynchronous induction machines with squirrel cage which are robust but need a current component to excite the magnetic field; and permanent magnet synchronous machines which rely on somehow more sensible parts but the magnets are able to excite a magnetic field without current. However; if speed gets high enough to reach the field weakening range; for both machine the field oriented control has to prescribe a field current sufficient to reduce the field not to exceed the voltage limits of the stator circuit. Especially for the permanent magnet synchronous machine this paper investigates whether it is possible to determine an optimal field current for every operation point to minimize either total current consumption or losses.
This paper presents a comprehensive computational fluid (CFD) model of a radial flux permanent magnet synchronous machine with interior magnets. In the CFD model the water jacket cooling and a simplified model of the topology of the distributed stator winding are considered. The heat sources of the CFD model are determined from a finite element analysis of the machine. The numerically determined temperature distributions of the machine are compared with measurement results from sensors located both in the stator and rotor. The particular focus of this paper is the analysis of the temperatures and the heat flow in the air gap and from the stator winding head and the rotor to the inner air.
The majority of the work performed for detecting eccentricity faults for permanent magnet synchronous motors (PMSM) focus on motor current signature analysis (MCSA), as it provides continuous on-line monitoring with existing current sensors. However, MCSA cannot be applied under nonstationary conditions and cannot distinguish faults with load torque oscillations, which are limitations for many PMSM drive applications. In this paper, it is shown that the d-axis inductance, L d , decreases with increase in the severity of eccentricity due to the change in the degree of magnetic saturation, and it is proposed as a new fault indicator. The inverter can be used to perform a standstill test automatically whenever the motor is stopped, to measure L d for eccentricity testing independent of load variations or oscillations, which is not possible with MCSA. An FE and experimental study on a 10hp PMSM verifies that eccentricity can be detected independent of the load with high sensitivity and reliability.