Energie und Mobilität
Refine
Year of publication
Document Type
- conference proceeding (article) (168)
- Article (143)
- Part of a Book (41)
- conference talk (32)
- Report (19)
- conference proceeding (presentation, abstract) (8)
- Book (7)
- Master's Thesis (4)
- Preprint (4)
- Part of Periodical (3)
- Edited collection (1)
- Review (1)
Is part of the Bibliography
- no (431)
Keywords
- Energiewende (27)
- Erneuerbare Energien (27)
- Klimaneutralität (22)
- Power-to-Gas (21)
- Sektorenkopplung (16)
- Energiespeicher (14)
- Power-to-X (9)
- Wasserstoff (8)
- Netzplanung (7)
- Blindleistung (6)
Institute
- Fakultät Elektro- und Informationstechnik (240)
- Fakultät Maschinenbau (155)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (76)
- Combustion Engines and Emissions Control Laboratory (CEEC) (40)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energienetze (38)
- Labor Elektrische Maschinen und Antriebstechnik (37)
- Computational Mechanics and Materials Lab (CMM) (20)
- Technologie-Campus Neustadt an der Donau (20)
- Labor Intelligente Materialien und Strukturen (17)
- Fakultät Informatik und Mathematik (15)
Begutachtungsstatus
- peer-reviewed (187)
- begutachtet (15)
Mechanical Energy Storage
(2019)
Chemical-energy storage systems use caverns, porous storage facilities, tanks, and storage rooms to store chemical energy sources. Caverns, caves, and reservoirs can also be used to store gaseous media such as air, liquid media such as water, and solid media such as rock. The principles of mechanical energy storage are based on classical Newtonian mechanics, or in other words on fundamental physics from the eighteenth and nineteenth centuries. As a result, these types of storage are typically divided into two categories; storage of kinetic and potential energy, or storage of ‘pressure energy’. In this chapter, storage media is categorized by its aggregate state, and described by its function and application: first compressed air energy storage and then conventional electricity storage—pumped-storage plants. The chapter continues with a discussion of innovative methods of storing potential energy using water as a medium. These include artificially constructed pumped storage, pumped storage in the open sea, dam storage on rivers, pumped storage on heaps in repurposed mining areas, underfloor or underground pumped storage, and surface mine storage. The chapter concludes with a description of classical and modern flywheel energy storage systems. This age-old technology is then compared with a new concept: mechanical stored energy exploiting both pumped storage and change in the potential energy of rocks or large boulders.
The use of alternative fuels in high-power non-road mobile machinery (NRMM) combustion engines is a possible way to substitute fossil fuel. By using pure vegetable oil fuels, like rapeseed oil fuel (DIN 51605), the greenhouse gases can be reduced effectively. Due to the differences in physical and chemical properties, a modification of the engine control unit calibration is necessary to adapt the working process on the fuel. Without modifications, the engine power output with rapeseed oil fuel is lower than with diesel fuel because of the smaller energy content. By adapting the engine settings, like the injection fuel mass, the power loss can be compensated but it accompanies with a higher fuel consumption. The engine emissions at part load conditions show, that there are benefits in particle emissions by using rapeseed oil at similar NOx emissions. Therefore, a design of experiment setup was initiated on a selected engine operation point to determine the effects of further parameters, like rail pressure, manifold pressure and injection pattern, on the process and to see the potential of an optimized calibration.
This paper addresses the optimisation of monitoring and decision-making criteria regarding the future use of structures. The current state of practice in standards and reliability framework are initially summarised. A general methodology for obtaining cost-optimal decisions is then presented on the basis of limit state design, probabilistic reliability analysis and cost estimates. The implementation of the risk-based approach is illustrated in a case study dealing with the roof of a stadium located in northern Italy. As the roof fails to comply with the requirements of the Eurocodes, the installation of a permanent monitoring system is recommended to allow for a real-time reliability assessment. The results demonstrate the potential of monitoring systems and probabilistic reliability analysis for supporting decisions regarding safety measures such as snow removal or temporary closure of the stadium, as well as reflecting the need to implement the discussed procedures in future standards.
Die Energiewende führt zu neuen Herausforderungen für Verteilungsnetzbetreiber hinsichtlich der Erbringung von Systemdienstleistungen, der Integrationsfähigkeit weiterer Erzeugungsanlagen und Lasten sowie bei der Gewährleistung einer hohen Versorgungssicherheit. Die Deckung der steigenden Blindleistungsbedarfe seitens der Netzbetriebsmittel, Verbraucher und Erzeuger gewinnt durch den Wegfall der Großkraftwerke für Netzbetreiber zunehmend an Bedeutung.Das abgeschlossene und vom BMWi geförderte Projekt SyNErgie (Laufzeit von 03/2015 bis 05/2018) beschäftigt sich mit der Entwicklung von Blindleistungsmanagementsystemen für Mittelspannungsnetze (MS-Netze). Ziel dabeiist es, das bisher ungenutzte, freie Blindleistungspotenzial betrieblicher Kompensationsanlagen und dezentraler Erzeugungsanlagen (allg.: Q-Quellen) zu nutzen, um die Blindleistungsänderungsfähigkeit 1 eines Verteilungsnetzes zu erhöhen. Diese Veröffentlichung stellt ausgewählte Einzelergebnisse und Erfahrungen des Projektes vor, welche u. a. über zahlreiche Messungen inMS-Netzen bei Firmen mit Anschlusspunkt in der MS-Ebene, Netzsimulationen und mathematische Modelle abgeleitet wurden.
As the world is getting more connected, the demands of services in automotive industry are increasing with the requirements such as IoT (Internet of Things) in cars, automated driving, etc. Eventually, the automotive industry has evolved to a complex network of servi ces, where each organization depends on the other organizations, to satisfy its service requirements in different phases of the vehicle life cycle. Because of these heterogeneous and complex development environments, most of the vehicle component interface models need to be specified in various manifest ations to satisfy the semantic and syntactic requirements, specific to different application development environments or frameworks. This paperdescribes an approach to semantic analysis of components interfaces description models of heterogeneous frameworks, that are used for vehicle applications. The proposed approach intends to ensure that interface description models of different service-based vehicle frameworks can be compared, correlated and re-used based on semantic synergies, across different vehicle platforms, development environments and organizations. The approach to semantic synergy exploration could further provide the knowledge base for the increase in interoperability, overall efficiency and development of an automotive domain specific general software solutions, by facilitating coexistence of components of heterogeneous frameworks in the same high-performance ECU for future vehicle software.
Masonry structures were built by various techniques using different materials, the properties of which exhibit a considerable scatter dependent on periods of construction and region-specific conditions. For historic structures with a heritage value, various non- or minor-destructive tests (NDTs) are commonly applied, while the application of destructive tests (DTs) is minimized. The contribution is based on investigations of 15 historic stone and clay brick masonry structures, for which NDT strengths of masonry units are verified by DTs. The proposed operational approach makes it possible to account for statistical uncertainty due to a limited number of DTs used to calibrate NDTs.
DC- DC converters control the power flow and thus the power distribution between the components on different voltage levels. They are essential for (dis)charging batteries and influence the safety and stability of the entire battery management system (BMS). Therefore, testing the functionality and the reliability of DC-DC converters is crucial. This is especially true for decentralized battery management systems (DBMS), where multiple nodes communicate to collectively control the system. The used DC-DC converters are modified to parameterize them during operation via microcontroller interfaces. Integrating the communication into the control loop requires an analysis of the control behavior due to additional delays. Therefore, this paper proposes a framework to test DC-DC converters considering the control and communication perspectives. The response time, the control accuracy and stability of these DC-DC converters, e.g., under continuous and abrupt load changes, are measured in automated tests. The dedicated software framework simulates the DBMS and stimulates the hardware components (e.g. electronic loads, data acquisition) via respective interfaces (CAN, RS232). This allows the test of various DC-DC converters with flexibly adaptable load and power generation profiles. An initial application validates the test framework by verifying the aforementioned aspects and thus the applicability of a DC-DC converter within the DBMS.
The development of 48V high power (>15 kW) automotive propulsion drives demands close integration of the power electronics and the electrical machine. Due to the large operating currents distributed multi-phase topologies are needed and physically separating the power converter from the e-machine would involve heavy cabling and costly connections. The volume and cost of the filter capacitor represents a major challenge in closely integrated high power integrated modular motor drives and techniques are needed to minimize this. The DC-link capacitor requires a large ripple current handling capability and cost, size and reliability limitations result in suitable candidate technologies being those with low volumetric energy densities. Use of interleaved multi three-phase machines are attractive due to the associated capacitor ripple current reduction. Discontinuous modulation schemes may also be employed as a technique for reducing the current ripple. In this paper techniques for capacitor ripple reduction are assessed through simulation and compared.
With an increasing number of sold electric vehicles (EVs), a large number of used batteries will be at disposal. How to deal with these resources is one of the major challenges in reducing the environmental impact of batteries throughout their entire life cycle. Heterogeneous cell parameters due to the different usage histories are a challenge for second-life use. The effort and cost of remanufacturing required to test and assemble a new battery pack is a further concern. Systems that combine battery packs/modules without full reassembly offer advantages such as cost and reusability. A decentralized battery management system (DBMS) provides a suitable architecture for such systems involving different types of batteries. In this paper, an architecture for a decentralized, battery state-dependent control is shown. The proposed DBMS supports various types of batteries, is scalable and flexibly adaptable for a wide range of applications. Despite the significant advantages, there are increased requirements to meet for the hardware implementation and the applied control strategies. Therefore, the necessary hardware components and their requirements are described and the hardware implementations are provided.