Fakultät Angewandte Natur- und Kulturwissenschaften
Refine
Year of publication
Document Type
- Article (171)
- conference proceeding (article) (156)
- Report (18)
- Part of a Book (15)
- Preprint (12)
- Book (6)
- conference proceeding (presentation, abstract) (6)
- conference talk (6)
- Study Thesis (3)
- Bachelor-/Diplom Thesis (2)
Is part of the Bibliography
- no (404)
Keywords
- field emission (24)
- silicon (15)
- Current measurement (13)
- Iron (10)
- elemental semiconductors (9)
- CATHODES (8)
- field emitter arrays (8)
- Etching (7)
- Photoacoustic spectroscopy (7)
- field emitter array (7)
Institute
- Fakultät Angewandte Natur- und Kulturwissenschaften (404)
- Labor Mikrosensorik (122)
- Labor Nanoanalytik und Halbleiterchemie (Nanochem) (70)
- Sensorik-Applikationszentrum (SappZ) (68)
- Labor Bauphysik (49)
- Fakultät Maschinenbau (9)
- Labor Empirische Sozialforschung (7)
- Labor Faserverbundtechnik (LFT) (6)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (5)
- Institut für Sozialforschung und Technikfolgenabschätzung (IST) (5)
- Fakultät Elektro- und Informationstechnik (4)
- Fakultät Informatik und Mathematik (3)
- Labor für Technikfolgenabschätzung und Angewandte Ethik (LaTe) (3)
- Technologie-Campus Neustadt an der Donau (3)
- Fakultät Bauingenieurwesen (2)
- Fakultät Betriebswirtschaft (2)
- Labor Optische Übertragungssysteme (2)
- Laboratory for Safe and Secure Systems (LAS3) (2)
- Regensburg Center of Biomedical Engineering - RCBE (2)
- Hochschulleitung/Hochschulverwaltung (1)
- Labor Biofluidmechanik (1)
- Labor Biomechanik (LBM) (1)
- Labor Intelligente Materialien und Strukturen (1)
- Labor für Baustoffe (1)
- Nachhaltiges Bauen (KNB) (1)
- Regensburg Center for Artificial Intelligence - RCAI (1)
- Regensburg Center of Health Sciences and Technology - RCHST (1)
- Regensburg Strategic IT Management (ReSITM) (1)
Begutachtungsstatus
- peer-reviewed (179)
- begutachtet (5)
This research presents two laser-based photoacoustic approaches for analyzing exhaled breath isoprene and acetone. The integration of a PTR-ToF-MS as a reference device ensured the reliability and accuracy of the PAS systems that is based on an ICL for isoprene and a QCL for acetone detection. The calibration yielded limits of detection of 26.9 ppbV and 1.7 ppbV, respectively, and corresponding normalized noise equivalent absorption coefficients (NNEAs) of 5.0E-9 Wcm-1Hz-0.5 and 4.9E-9 Wcm-1Hz-0.5. Laboratory as well as real breath sample measurements from alveolar breath revealed a robust system performance, with only one outlier within the static isoprene measurements. However, discrepancies emerged under dynamic breath sampling conditions, emphasizing the need for further optimization. Especially by knowing the dynamic nature and endogenous origin of exhaled isoprene our findings highlight the potential of breath analysis for non-invasive physio-metabolic and pathophysiological monitoring towards point-of-care devices.
Academic self-regulation is a key factor for motivation and learning achievement. Yet with the large range of individual factors, this is not a one-size-fits-all proposition. This study of L2 Technical English students at two German universities explored learners’ expectations and motivations, in particular regarding self-regulation and self-efficacy via the individual’s time investment in self-led study. In an initial survey, learners (N=1646) reported on their English skill levels and anticipated learning habits. Complementarily, the retrospective survey investigated learners’ (N=796) actual behavior during the course, their perceptions of language skill improvement, and their satisfaction. The initial survey indicates a clear understanding that time investment in self-regulated study will lead to greater improvement, an outcome confirmed in the retrospective survey. Additionally, students who invested more time in their coursework were more satisfied with their achievement, although most learners acknowledge they should have studied more. The results verify that learners recognize the nexus between self-regulation and language skill improvement, yet university students are not satisfied with their capacity to self-regulate their language learning strategies. While differences in students’ skill levels and academic self-efficacy result in divergent degrees of progress, students of all types report benefits to their language skills when motivated to self-regulated study.
We investigate the influence of the geometry and doping level on the performance of n-type silicon nanowire field emitters on silicon pillar structures. Therefore, multiple cathodes with 50 by 50 pillar arrays (diameter: 5 μm, height: 30 μm, spacing: 50 μm) were fabricated and measured in diode configuration. In the first experiment, we compared two geometry types using the same material. Geometry 1 is black silicon, which is a highly dense surface covering a forest of tightly spaced silicon needles resulting from self-masking during a plasma etching process of single crystal silicon. Geometry 2 are silicon nanowires, which are individual spaced-out nanowires in a crownlike shape resulting from a plasma etching process of single crystal silicon. In the second experiment, we compared two different silicon doping levels [n-type (P), 1–10 and <0.005 Ω cm] for the same geometry. The best performance was achieved with lower doped silicon nanowire samples, emitting 2 mA at an extraction voltage of 1 kV. The geometry/material combination with the best performance was used to assemble an integrated electron source. These electron sources were measured in a triode configuration and reached onset voltages of about 125 V and emission currents of 2.5 mA at extraction voltages of 400 V, while achieving electron transmission rates as high as 85.0%.
An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone
(2024)
n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.
An Inexpensive Uv-Led Photoacoustic Based Real-Time Sensor-System Detecting Exhaled Trace-Acetone
(2024)
In this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 6.4 ppbV and an NNEA of 1.1E-9 Wcm-1Hz-0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.
Für den sicheren Betrieb eines Brennstoffzellenfahrzeugs sind Sensoren wichtig, welche die Wasserstoffkonzentration im Fahrzeuginterieur kontinuierlich überwachen, um möglichen Entzündungen bzw. Explosionen vorzubeugen. Dafür wurden von verschiedenen nationalen und internationalen Instanzen bestimmte Kriterien definiert, die Wasserstoffsensoren für einen Einsatz in Brennstoffzellenfahrzeugen erfüllen müssen. Im Jahr 2020gab es noch keinen einzigen kommerziell erhältlichen Sensor, der alle diese Kriterien bedienen konnte.
In der vorliegenden Arbeit wurde für zwei verschiedene Sensoren die Eignung des thermischen Wirkprinzips für die Detektion von Wasserstoff im Kontext dieser Sicherheitskriterien untersucht. Dabei wurden mit einem MEMS-Sensor und einem Mikrodrahtsensor zwei vergleichsweise einfache Geometrien herangezogen, welche den eindimensionalen und zylindersymmetrischen Fall abbilden sollen. Für zwei dynamische Operationsmodi (gepulste Ströme und 3ω-Methode) wurden darauf aufbauend analytische Modelle basierend auf vereinfachten Sensorgeometrien entwickelt, um die Temperaturentwicklung des
Sensorelements in Abhängigkeit der Zeit zu charakterisieren. Diese Studien wurden anschließend anhand von detaillierteren Modellen mithilfe von FEM-Simulationen ergänzt und spezifiziert. Darin konnte gezeigt werden, dass für den gepulsten Betrieb sowohl die Pulshöhe als auch die Zeitkonstante des gemessenen Widerstands- bzw. Temperaturpulses als Messgröße herangezogen werden kann. Beim 3ω-Betrieb konnte zudem eine starke Frequenzabhängigkeit dieser Widerstands- bzw. Temperaturcharakteristik beobachtet werden. Die analytischen und numerischen Studien wurden anschließend durch experimentelle Ergebnisse bestätigt. Im Hinblick auf die zuvor definierten Kriterien stellte sich heraus, dass die Auswertung der Zeitkonstante beim gepulsten Betrieb im Hinblick auf Sensitivität und Auflösungsgrenze der Auswertung der Pulshöhe deutlich unterlegen ist. Beim 3ω-Betrieb können durch die hochintegrierte Messumgebung deutlich höhere Genauigkeiten und Auflösungsgrenzen erzielt werden. Für den MEMS-Sensor wurde bei einer Anregungsfrequenz von 1 Hz mit 55 ppm die bislang geringste in der Literatur berichtete Auflösungsgrenze für einen thermischen Wasserstoffsensor erreicht. Der Leistungsverbrauch ist dabei im Vergleich zum Pulsbetrieb entsprechend des jeweiligen Tastgrads leicht bis mäßig erhöht, die Ansprechzeit wird bei beiden Operationsmodi maßgeblich durch die Sensorgeometrie beeinflusst. Die geometrischen Parameter der jeweiligen Sensoren haben ferner einen starken Einfluss auf die Sensitivität, womit die Divergenz in der
Performance von MEMS-Chip und Drahtsensor erklärt werden kann. Es besteht ferner eine starke Temperatur- und Feuchtigkeitsabhängigkeit des Sensorsignals, welches bei beiden Operationsmodi indirekt proportional zur Wärmeleitfähigkeit des betrachteten Gasgemischs ist. Die Abhängigkeit vom definierten Umgebungsdruck ist lediglich für die
Zeitkonstante relevant, bei der Pulshöhe besteht keine Druckabhängigkeit. Es konnte eine grundsätzliche Eignung des thermischen Messprinzips für den Einsatz eines Wasserstoffsensors im Automobilbereich festgestellt werden. Für eine Anwendung müssen allerdings Referenzsensoren für Temperatur, Feuchtigkeit und Druck implementiert werden und eine Kalibrierung in Abhängigkeit dieser Größen erfolgen. Der 3ωBetrieb ist aufgrund der höheren Genauigkeit zu bevorzugen. Während der MEMSSensor im Hinblick auf Sensitivität, Ansprechzeit und Leistungsaufnahme gut abschneidet, liegen die Vorteile des Mikrodrahtsensors in seiner Robustheit und der vergleichsweise einfachen Realisierbarkeit
The article presents the process of developing a silicon electron source designed for high-vacuum microelectromechanical system (HV MEMS) devices, i.e., MEMS electron microscope and MEMS x-ray source. Technological constraints and issues of such an electron source are explained. The transition from emitters made of carbon nanotubes to emitters made of pure silicon is described. Overall, the final electron source consists of a silicon tip emitter and a silicon gate electrode integrated on the same glass substrate. The source generates an electron beam without any carbon nanotube coverage. It generates a high and stable electron current and works after the final bonding process of an HV MEMS device.
In this work, high-current field emission electron source chips were fabricated using laser-micromachining and MEMS technology. The resulting chips were combined with commercially available printed circuit boards (PCBs) to obtain a multichip electron source. By controlling the separate electron sources using an external current control circuit, we were able to divide the desired total current evenly across the individual chips deployed in the PCB-carrier. In consequence, we were able to show a decreased degradation due to the reduced current load per chip. First, a single electron source chip was measured without current regulation. A steady-state emission current of 1 mA with a high stability of ±1.3% at an extraction voltage of 250 V was observed. At this current level, a mean degradation slope of −0.7 μA/min with a nearly perfect transmission ratio of 99% ± 0.4% was determined. The measurements of a fully assembled multichip PCB-carrier electron source, using a current control circuit for regulation, showed that an even distribution of the desired total current led to a decreased degradation. This was determined by the increase in the required extraction voltage over time. For this purpose, two current levels were applied to the electron source chips of the PCB-carrier using an external current control circuit. First, 300 μA total current was evenly distributed among the individual electron source chips followed by the emission of 300 μA per electron source chip. This allows the observation of the influence of a distributed and nondistributed total current, carried by the electron source chips. Thereby, we obtained an increase in the mean degradation slope from +0.011 V/min (300 μA distributed) to +0.239 V/min (300 μA per chip), which is approximately 21 times higher. Moreover, our current control circuit improved the current stability to under 0.1% for both current levels, 300 μA distributed and 300 μA per chip.
Media watchdog weblogs can play an important role in media accountability, provided that the bloggers are regularly active and have an appropriate awareness of their role in the media landscape. The following article examines the presence and influence of media watchblogs in selected nations, as well as the operators’ standards and perceptions of their roles. In semi-structured qualitative interviews, operators of watchblogs in Germany, Austria, Switzerland and the United Kingdom discussed their perceptions of their role, their ethical guidelines, their financing and any conflicts of interest, and their projections for the future. The interviews reveal that most media watchbloggers do not interpret their role to be a Fifth Estate with a mandate to monitor the mass media. The watchbloggers are reluctant to accept and uphold formal ethical and quality criteria, and limitations on time and money make them unable to guarantee ongoing critical media analysis. For these reasons, media watchblogs are determined to be a weak instrument of media accountability.
Eine Herausforderung performancebasierter Prüfverfahren zur Bewertung der Dauerhaftigkeit ist die Beschleunigung natürlicher Mechanismen. Dies ist notwendig, um innerhalb kurzer Zeit die Langzeit-Leistungsfähigkeit ermitteln zu können. Die Bestimmung der Frost-Tausalzbeständigkeit von Beton kann durch den CDF-Test erfolgen, welcher für Betone mit ausreichendem Frost-Tausalz-Widerstand sehr gut funktioniert. Bei Proben mit einer unzureichenden bzw. unbekannten Performance können erhöhte Randabwitterungen auftreten, welche durch das Ablösen des seitlichen Abdichtbands entstehen. Der zunehmende Randeinfluss führt so zu einer Verfälschung der Ergebnisse und zu einer Unterschätzung der tatsächlichen Performance des Bauteils. In diesem Beitrag werden Mörtel- und Betonprobekörper mit unterschiedlichen Abwitterungsraten in Anlehnung an das CDF-Verfahren untersucht. Zusätzlich wird die Oberflächenschädigung der Proben anhand einer neuartigen Messmethode mittels hochauflösendem 3D-Laserscanning ausgewertet. Die Ergebnisse zeigen, dass die Randeffekte mit der Laserscan-Methode umgangen und vergleichbare Ergebnisse zu den CDF-Untersuchungen erzielt werden können. Somit können Betone ohne Randeinflüsse charakterisiert und eine präzise Prognose der Langzeitbeständigkeit getroffen werden.
Hochschulen für angewandte Wissenschaften (HAW) kommt als regionalen Innovationstreibern eine gesellschaftliche Verantwortung durch ihre Zusammenarbeit mit Unternehmen und Gesellschaft zu. Diese Zusammenarbeit geschieht im Rahmen von Aktivitäten des Wissens- und Technologietransfers. Die Beurteilung des Erfolgs dieser Transferaktivitäten verursacht jedoch regelmäßig Schwierigkeiten, da geeignete Indikatoren zur Erfolgsmessung fehlen. Im Rahmen des vom Bundesministerium für Bildung und Forschung (BMBF) geförderten Verbundforschungsprojektes Transfer_i wurde ein Modell zur Objektivierung und Messung von Forschungsleistung, forschungsbasiertem Transfer sowie dessen Umsetzung am Markt in Form von Innovationen erarbeitet. Mit dem Forschungsprojekt wurden kausale Zusammenhänge für das Gelingen von Transfer identifiziert und daraufhin entsprechende Indikatoren definiert, um auf dieser Basis die Steuerung von Transferprozessen zu ermöglichen.
In diesem Beitrag werden zwei im Projekt Transfer_i entwickelte Modelle und Indikatoren vorgestellt, die die Voraussetzungen für einen erfolgreichen Transferprozess abbilden können. Auf dieser Grundlage zeigen wir anhand eines Projekts (MAGGIE) der Ostbayerischen Technischen Hochschule (OTH) Regensburg mit mehreren regionalen Partnern, wie die vorher definierten Modelle und Indikatoren in einem konkreten Anwendungsfall verwendet werden können. Abschließend beschreiben wir die erforderlichen Rahmenbedingungen für die erfolgreiche Umsetzung von Transfer an Hochschulen und wie darauf bezogene Indikatoren effektiv eingeführt werden können.
The performance of nanoelectronic and molecular electronic devices relies strongly on the employed functional units and their addressability, which is often a matter of appropriate interfaces and device design. Here, we compare two promising designs to build solid-state electronic devices utilizing the same functional unit. Optically addressable Ru-terpyridine complexes were incorporated in supramolecular wires or employed as ligands of gold nanoparticles and contacted by nanoelectrodes. The resulting small-area nanodevices were thoroughly electrically characterized as a function of temperature and light exposure. Differences in the resulting device conductance could be attributed to the device design and the respective transport mechanism, that is, thermally activated hopping conduction in the case of Ru-terpyridine wire devices or sequential tunneling in nanoparticle-based devices. Furthermore, the conductance switching of nanoparticle-based devices upon 530 nm irradiation was attributed to plasmon-induced metal-to-ligand charge transfer in the Ru-terpyridine complexes used as switching ligands. Finally, our results reveal a superior device performance of nanoparticle-based devices compared to molecular wire devices based on Ru-terpyridine complexes as functional units.
Field emitter arrays (FEAs) are a promising component for novel vacuum micro- and nanoelectronic devices, such as microwave power amplifiers or fast-switching X-ray sources. However, the interrelated mechanisms responsible for FEA degradation and failure are not fully understood. Therefore, we present a measurement method for quantitative observation of individual emission sites during integral operation using a low-cost, commercially available CMOS imaging sensor. The emission and degradation behavior of three differently doped FEAs is investigated in current-regulated operation. The measurements reveal that the limited current of the p-doped emitters leads to an activation of up to 55% of the individual tips in the array, while the activation of the n-type FEA stopped at around 30%. This enhanced activation results in a more continuous and uniform current distribution for the p-type FEA. An analysis of the individual emitter characteristics before and after a constant current measurement provides novel perspectives on degradation behavior. A burn-in process that trims the emitting tips to an integral current-specific ideal field enhancement factor is observed. In this process, blunt tips are sharpened while sharp tips are dulled, resulting in homogenization within the FEA. The methodology is described in detail, making it easily adaptable for other groups to apply in the further development of promising FEAs.
Silicon nanowire field emission arrays (50 × 50 pillars) were fabricated on a silicon glass hybrid wafer. The glass acts both as the support for the whole structure and insulator between cathode and extraction grid. The extraction grid matches the emitter structures and is optically aligned and adhered to the emitter chip by a vacuum compatible epoxide adhesive. These chips exhibit an emission current of about 600 μA at an extraction voltage of 300 V. The electron transmission through the grid is above 80 %. 58-hour longtime measurements were conducted showing low degradation of the emission current and high stability of electron transmission.
It is common practice to use maximum FAST time-weighted sound pressure levels to assess transient impact noise, as these levels correlate well with human perception of impact noise. Maximum FAST time-weighted levels are known to be dependent on the reverberation time of the receiving room. In previous studies, an analytical correction term was developed using a Dirac impulse. The correction term is used to calculate the maximum FAST time-weighted levels from peak sound pressure levels. Peak levels are independent of the reverberation time of the room. Applying the correction term makes it possible to compare measurement results from different rooms. The correction term has been validated in several studies for the standard rubber impact ball. In this paper, the influence of the source signal (Dirac impulse) on the correction term is studied. Analytical and numerical models are employed to investigate the consequences of stretching the impulse in time and of changing its shape. The results are compared with empirical solutions developed in other studies.
A silicon field emission electron source consisting of a cathode and a grid electrode has been fabricated by laser micromachining. The cathode features 21×21 tips on an area of 4×4 mm 2 , With a self-aligning MEMS technology for the aperture grid, a high electron transmission (99 %) was achieved. Onset voltages of 50…70 V were observed for an emission current of 1 nA. A stable emission current of 1 mA ± 1.3 % at an extraction voltage of 250 V was observed during a 30-min operation.
To decrease the number of kilometers driven during the development of autonomous cars or driving assistance systems, performant simulation tools are necessary. Currently, domain distance effects between simulation and reality are limiting the successful application of rendering engines in data-driven perception tasks. In order to mitigate those domain distance effects, simulation tools have to be as close to reality as possible for the given task. For optical sensors like cameras, the luminance of the scene is essential. We provide within this paper a method to measure the luminance of rendered scenes within CARLA, an often used open-source simulation environment. Thereby, it is possible to validate the environment and weather models by taking real-world measurements with photometric sensors or with the help of open-source weather data, published e.g. by the German federal service for weather data (DWD - "Deutscher Wetterdienst"). Employing our proposed luminance measurement, the domain gap resulting from the simulation can be specified, which makes it possible to evaluate the statements about the safety of the automated driving system determined within the simulation. We show that the ratio between global and diffuse radiation modeled by the default atmosphere models within CARLA are under limited conditions similar to real-world measurements taken by the DWD. Nevertheless, we show, that the ratio’s temporal variability in real-world situations is not modeled by CARLA.