The intention of this compilation of articles was to introduce brand-new developments in the field of chemical imaging which have not been discussed in previous review articles. These include the design of new sensor nanomaterials based on photon uponversion crystals which convert near-infrared excitation light into sensor signals in the visible wavelength range highlighted by Christ and Schäferling. Sun, Ungerböck and Mayr describe the state of the art in oxygen imaging in microreactors and microfluidic devices. Miniaturized sensors for the imaging of oxygen, pH and temperature in microchips, microfluidic platforms and microbioreactors are reviewed by Pfeiffer and Nagl. Furthermore, Dmitriev and Papkovsky present a critical assessment of the applicability of probes for intracellular oxygen sensing.
I hope these articles provide an interesting insight into advanced luminescent sensor materials and the applications of optical micro- and nanosensors in fluorescence imaging today and will be inspiring for the reader. Finally, I would like to thank all authors and referees for spending their time to enable this collection of articles.
This project aims to develop capacity to produce certified reference materials (CRMs) for environmental analysis by transferring know-how between the partners and combining their skills to focus on environmental CRM production. The production process includes good manufacturing practices for processing materials, method development, the validation and application of homogeneity, stability and characterisation tests, the calculation of individual uncertainties (between-unit inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. An inter laboratory comparison registered as a EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
Reliable analysis of chemical indicators in water, sediment and soil samples for the purpose of environmental pollution assessment poses one of the greatest analytical challenges, having in mind the complexity of sample matrix and low concentrations of pollutants. Organics (pesticides, PAHs, PCBs, etc.) and heavy metals (Hg, Cd, Ni, Pb and As) represent target parameters. Laboratories performing sampling and tests in this field regulated by respective EU directives [1], need strong support in terms of providing them with appropriate matrix CRMs enabling the process of quality control. NMIs and DIs with proven metrological capabilities for the production and certification of such materials are necessary for the provision of quality data. This project is aiming to develop capacity to produce CRMs for environmental analysis by transferring the theoretical and practical know-how between the partners and combining their skills to focus on environmental CRM production in accordance with ISO Guide 34 [2]. Production process includes good manufacturing practices for processing materials, method development and validation for homogeneity, stability and characterisation tests, characterisation of selected analytes together with additional information about matrix constituents, the calculation of individual uncertainties (between units inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. Inter laboratory comparison registered as EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
Zur Bestimmung von Arzneimittelrückständen in Oberflächengewässern wird häufig die LC-MS/MS als Methode der Wahl eingesetzt. Obwohl sich dieses Nachweisverfahren durch eine hohe Empfindlichkeit und Selektivität auszeichnet, gibt es vor allem bei geringen Substanzkonzentrationen häufig störende Einflüsse durch Matrixeffekte. Diese Matrixeffekte können unterschiedliche Ursachen haben.
Einige Matrixeffekte werden am Beispiel des Wirkstoffs Carbamazepin erläutert. Carbamazepin wird durch Kläranlagen nur partiell aus dem Abwasser entfernt und ist im Spurenbereich auch noch im Trinkwasser nachzuweisen. Wenn für die LC-MS/MS wasserbasierte Anteile in der mobilen Phase genutzt werden, befinden sich trotz Verwendung einer Labor-Reinstwasseranlage in der mobilen Phase noch kleinste Konzentrationen von Carbamazepin, welche einen Blindwert im unteren ppt-Bereich verursachen.
Weitere Matrixeffekte treten durch die unterschiedliche Qualität der Oberflächenwasserproben auf. Koelutionen von weiteren Inhaltstoffen zeitgleich mit dem Zielanalyten führen zu einer Diskriminierung des Meßsignals. Verbindungen, die den gleichen Massenübergang bei nahezu identischer Retentionszeit zeigen, erfordern eine reproduzierbare chromatographische Vortrennung oder die Wahl einer alternativen HPLC-Säule.
Untergrundspeicher für Roh- und Abfallstoffe gewinnen zunehmend an Bedeutung. Verwendet werden sie vor allem für Stoffe wie Erdgas, Wasserstoff, Erdöl und neuerdings auch für Kohlen-stoffdioxid (CO2). Diese Stoffe werden meist unter Druck in Kavernen- oder Porenspeichern einge-lagert. Die Speicher dienen einerseits zum Ausgleich von Ungleichgewichten zwischen Ange-bot/Förderung und Nachfrage/Verbrauch und zur Erhöhung der Versorgungssicherheit. Anderer-seits bestehen Konzepte Abfallstoffe oder Gefahrstoffe für die Umwelt (aktuell CO2-Speicherung) dort für lange Zeiträume einzulagern. Mit den Einlagerungsstoffen verbunden ist ein signifikantes Gefahrenpotential für Mensch und Umwelt, falls es trotz aller Sicherheitsmaßnahmen zu einem unkontrollierten Austritt dieser Stoffe kommen sollte. Daher kommt dem Monitoring derartiger Untergrundspeicher und den darüber befindlichen Bodenstrukturen eine extrem hohe Bedeutung zu.
Ein hochaktuelles Beispiel, das die Überwachung entsprechender Bodenflächen fordert, ist die unterirdische CO2-Speicherung im Rahmen der CO2-Abscheidung und -Speicherung (Carbon Dioxide Capture and Storage, CCS). CCS gilt als wichtige Brückentechnologie der Energiewirtschaft und wird weltweit vorangetrieben, während die Sicherheit von Bevölkerung und Biosphäre noch kont-rovers diskutiert wird. Auch die EU setzt auf CCS und gibt in der EU-Richtlinie 2009/31 als Ziel-setzung bis 2015 vor, 15 Pilotanlagen zu bauen und in Betrieb zu nehmen. Als Bedingung für die Genehmigung der CO2-Speicherung ist explizit die Überwachung der Speicheranlagen durch Monito-ring vorgeschrieben, wobei die technisch besten Lösungen zum Einsatz kommen sollen.
Das zu entwickelnde Messsystem adressiert neben den o.g. Anwendungsfeldern weitere, bei denen insbesondere die Emission von Gasen ein Risiko für Mensch und Umwelt darstellt oder wirt-schaftlichen Schaden verursachen kann. Hierzu zählen die Überwachung von Abfalldeponien, Ge-fahrgutlagerstätten, kontaminierten Altlastengebieten, Moor-, Torf-, Kohleflözen (präventive Branderkennung) und geodynamisch aktiven Regionen. Auch moderne Fördertechnologien, wie das Hot-Dry-Rock-Verfahren (HDR) zur Energiegewinnung durch Einpressen von überkritischem CO2 in den Erdkörper, das die Beweglichkeit eines Gases mit der Dichte einer Flüssigkeit kombiniert und Wärmeaustausch im Erdinneren bewirkt, bergen das Risiko unkontrollierter Gasemissionen und bedürfen der umfassenden Überwachung.
The increasing pollution of terrestrial and aquatic ecosystems with plastic debris, which leads to the accumulation of microscopic plastic particles of still unknown fate, is an upcoming problem of our time. In order to monitor the degree of contamination and to understand the underlying processes of degradation and internalization of plastic debris, analytical methods are urgently needed, which help to identify and quantify microplastics. Currently, expensive collected and purified materials enriched on filters are investigated by (micro) infrared spectroscopy (FTIR). Few studies using micro-Raman spectroscopy have been published as well. In contrast to FTIR, Raman spectroscopy can handle wet samples, but it suffers from interference of fluorescent materials. Both micro-FTIR- and micro-Raman, always include time consuming scanning and mapping procedures followed by the manual inspection and measurement of selected particles.
Troubleshooting Samples Analytics:
Impurities in products: unexpected & unwanted occurrence, unknown identity, analytical method unclear, often various analytical methods, necessary, short response time important (< 1 d), benefits: allocation of its source within hours safes cost
• Investigations planned, coordinated and documented by TSA team
• Variety of analytical methods available
The paper addresses beech wood as well as vulcanized fiber and discusses the results obtained when using acoustic emission and thermography as non-destructive testing techniques along tensile and load increase fatigue tests to characterize the wooden material’s behavior under increasing fatigue loads to get enhanced information regarding the fatigue behavior of both materials. Reference is mainly made to the materials’ anisotropic and microstructural behavior and what implications this has with respect to the materials’ strength. The influence of moisture is discussed, as well as parameters that may deserve monitoring in the sense of structural health monitoring to be applied in timber structures in general.
Sixteen Ayyubid-Mamluk glazed pottery sherds were analyzed in order to identify and characterize the elemental composition to determine their provenance. The tested sherds were collected from the historical site of Karak Castle, southern Jordan.
Chemical analysis for the sixteen samples has been carried out using Synchrotron Radiation X-ray Fluorescence Spectrometry (SR-XRF) Technique. Furthermore, the semiquantitative analysis of the elements Fe – Cu – Zn – Br – Rb – Sr – Y – Zr – Nb – Mo – Pd – Ag – Cd and Pb has been performed for the samples based on Principal Component Analysis (PCA) and hierarchical Cluster Analysis with Bray-Curtis in order to define grouping of different glazed pottery by obtaining information on their similarity and clustering. The results of chemical analysis provided persuasive evidence that the Karak Castle pottery sherds have at least three different sources of provenance.
Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. This involves also jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty of this method is to predict the column diameter and its material strength. Here, we present two-dimensional finite-difference numerical simulation results of a promising non-destructive quality assurance testing tool to evaluate the diameter of jet grout columns. This approach incorporates crosshole and downhole seismic measurements. Preliminary tests showed that this tool is applicable under real site conditions.
The design of sample flow cells, commonly used in online analytics and especially for medium resolution NMR spectroscopy (MR-NMR) in low magnetic fields, was experimentally and theoretically investigated by 1H-NMR and numerical simulations. The flow pattern was characterised to gain information about the residence time distribution and mixing effects. Both 1H-NMR imaging and spectroscopy were used to determine the characteristics of flow cells and their significance for on-line measurements such as reaction monitoring or hyphenated separation spectroscopy. The volume flow rates investigated were in the range from 0.1 to 10 ml/min, typically applied in the above mentioned applications. When compared to those commonly used in high-field NMR, the special characteristics of flow cells for MR-NMR were revealed by various NMR experiments and compared with CFD simulations. The influence of the design of the inlet and outlet on the flow pattern was investigated as well as the effect of the length of the cell. For practical use, a numerical estimation of the inflow length was given. In addition, it was shown how experiments on the polarisation build-up revealed insight into the flow characteristics in MR-NMR.
Hydroformylation represents an important homogeneous catalyzed process, which is widely used within chemical industry. Usually applied with simple alkenes like Propene and Butene aldehydes obtained from alkenes >C6 are relevant intermediates in production of plasticizers, surfactants and polymers. Today the active catalyst species is often based on valuable Rhodium complexes in aqueous solution. This implies the problem of limited water solubility of the reactands, which is acceptable for short chain lengths, but states a problem in case of higher alkenes. Along with that efficient separation and recycling of the catalyst becomes more complicated. There are different approaches tackling this problem, e.g., by using of salt formation in the BASF process or downstream distillation within the Shell process
The Collaborative Research Center InPROMPT aims to establish a novel process concept for the hydroformylation of long-chained olefins, using a rhodium complex as catalyst in the presence of syngas. Recently, the hydroformylation in micro-emulsions, which allows for the efficient recycling of the expensive rhodium catalyst, was found to be feasible. However, the temperature and concentration sensitive multi-phase system demands a continuous observation of the reaction to achieve an operational and economically feasible plant operation. For that purpose, we tested the potential of both NMR and Raman spectroscopy for process control assistance. The lab-scale experiments were supported by sampling for off-line GC-analysis as reference analytics. The results of the NMR experiments will be part of another contribution.
This paper reflects recent progress in the field of fluorescent polymer optical fiber sensors (F-POF) for partial discharge (PD) detection in high voltage (HV) cable accessories using optical-only PD detection by coincidence single photon counting. In experiments with artificial PD sources these sensors show the ability to detect optical emissions from picocoulomb-level PDs in a real-scale model of a translucent high voltage cable accessory. False positives (caused by detector noise) are efficiently suppressedwhile maintaining sufficient sensitivity,even when the sensor is located in an unfavorable position.
Polyglycerol (PG) coated polypropylene (PP) films were synthesized in a two-step approach that involved plasma bromination and subsequently grafting hyperbranched polyglycerols with very few amino functionalities. The influence of different molecular weights and density of reactive linkers were investigated for the grafted PGs. Longer bromination times and higher amounts of linkers on the surface afforded long-term stability. The protein adsorption and bacteria attachment of the PP-PG films were studied. Their extremely low amine content proved to be beneficial for preventing bacteria attachment.
Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance). This showed that modern NMR equipment is also suitable for the observation of hydrocarbon samples in the expanded fluid phase or gas phase. Since Quantitative NMR spectroscopy (qNMR) is a direct ratio method of analysis without the need of calibration it was used to determine impurities in appropriate liquid and liquefied hydrocarbon isomers up to C6, which are used for preparation of primary gas standards, e.g., natural gas or exhaust gas standards. At the same time it is possible to yield structural information with a minimum of sample preparation. Thus, cross contaminations between different isomers of the observed hydrocarbons and their (NMR-active) impurities can be identified and quantified.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example the method has beneficially been used by National Measurement institutes for recent CCQM comparisons including the CCQM–K55 series of purity studies.
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of 4 individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
The need for technological progress in bio-diagnostic assays of high complexity requires both fundamental research and constructing efforts on nano-scaled assay recognition elements that can provide unique selectivity and design-enhanced sensitivity features. Nanoparticle induced sensitivity enhancement and its application related to multiplexed capability Surface-Enhanced InfraRed Absorption (SEIRA) assay formats are well suitable for these purposes. The potential of diverse fluorophore–antibody conjugates, being chemisorbed onto low-cost gold nanoparticulate SEIRA substrates, has been explored with respect to their spectral discriminability. These novel biolabels deliver molecular SEIRA fingerprints that have been successfully analyzed by both uni- and multivariate analyzing tools, to discriminate their multiplexing capabilities. We show that this robust spectral encoding via SEIRA fingerprints opens up new opportunities for a fast, reliable and multiplexed high-end screening in biodiagnostics.
Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. One commonly applied method is jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty linked with this method is to predict the resulting column diameter and its material strength. In this paper we illustrate the application of a newly developed non-destructive quality assurance testing tool used to determine the diameter of jet grout columns. This approach incorporates standard crosshole and downhole seismic measurements. To demonstrate its effectiveness, we tested the new approach within two-dimensional finite-difference numerical simulations. Additional field tests showed that this tool is also applicable in real site conditions. For this purpose, three jet grout columns were produced with different process parameters in a depth between 3.0 and 10 m. The evaluated diameters were within 1.0 and 1.5 m, slightly deviating from the previously predicted range by the jet grouting contractor. Moreover, we were able to detect the base of the columns at 10 m depth with no significant difficulties. On the other hand, unsaturated, partly unconsolidated sands between ground water level and surface considerably affected the seismic data, hence complicating the detection of the top of the columns.