Analytische Chemie
Filtern
Erscheinungsjahr
- 2015 (121) (entfernen)
Dokumenttyp
Schlagworte
- Prozessanalytik (9)
- Process analytical technology (7)
- Reaction monitoring (5)
- Concrete (4)
- Ground penetrating radar (4)
- Metrology (4)
- Online NMR spectroscopy (4)
- PFOS (4)
- Quantitative NMR-Spektroskopie (4)
- qNMR (4)
- Environment (3)
- Fluorescence (3)
- LIBS (3)
- Online NMR Spectroscopy (3)
- PFOA (3)
- Process Analytical Technology (3)
- Prozess-Spektroskopie (3)
- Raman spectroscopy (3)
- Reference material (3)
- Simulation (3)
- Smart Sensors (3)
- Soil (3)
- Transmission (3)
- XPS (3)
- Bisphenol A degradation (2)
- CRM (2)
- Chlorides (2)
- Crosshole (2)
- Downhole (2)
- Electron backscatter diffraction (2)
- Embedded sensors (2)
- Haftfestigkeit (2)
- Heavy metal (2)
- Hydroformylation (2)
- Industrie 4.0 (2)
- Jet grout (2)
- Microarray (2)
- Monitoring (2)
- Nanocatalysts (2)
- Nanomaterial (2)
- Nanoparticle (2)
- Nanoparticles (2)
- Orientation mapping (2)
- Prefabricated wall (2)
- Prozess-Sensoren (2)
- Quantum yield (2)
- Reflection (2)
- Reinforced concrete (2)
- Smarte Sensoren (2)
- TiO2 (2)
- Toxic metals (2)
- Ultrasonic (2)
- Ultrasound (2)
- Void detection (2)
- Wastewater (2)
- X-ray diffraction (2)
- XRF (2)
- Zentrifugentechnologie (2)
- 19F-NMR (1)
- 1H-NMR (1)
- 2D-map (1)
- 3D Reconstruction (1)
- 3D Rekonstruktion (1)
- AFM (1)
- API molecule (1)
- ASR (1)
- Absolute Isotopenverhältnisse (1)
- Absorption (1)
- Acidity (1)
- Acoustic emission (1)
- Acoustic test (1)
- Adsorption of pyridine (1)
- Advanced process control (1)
- Aggregate scattering (1)
- Air-coupled (1)
- Alkalis (1)
- Amino acid (1)
- Analyses of inks (1)
- Analytical quality assurance (1)
- Applikationslabor (1)
- Aqueous solution (1)
- Archäologie (1)
- Arzneimittelrückstände in Oberflächenwasserproben (1)
- Asymmetric flow filed-flow fractionation (1)
- BAMline (1)
- BODIPY-Farbstoffe (1)
- BONARES (1)
- Baustoffe (1)
- Baustoffuntersuchungen (1)
- Bearing steel (1)
- Belastungsversuch (1)
- Benchtop NMR Spectroscopy (1)
- Beschichtungen (1)
- Biological structure (1)
- Biozidanalytik (1)
- Blitzthermografie (1)
- Boden (1)
- Bodenfruchtbarkeit (1)
- Brennfleckgröße (1)
- CCS (1)
- CGHE (1)
- CO2 (1)
- CONSENS (1)
- Cadmium (1)
- Carbamazepin (1)
- Carbon dioxide (1)
- Carbon nanotube CNT (1)
- Carbonation (1)
- Catalysis (1)
- Catalytic wet peroxide oxidation (1)
- Cement (1)
- Characterization (1)
- Characterization method (1)
- Chemical analysis (1)
- Chemical sensors (1)
- Chemometrics (1)
- Chemometrie (1)
- Chloride (1)
- Civil engineering (1)
- Clinical diagnostics (1)
- Clustering (1)
- Coda wave interferometry (1)
- Coincidence (1)
- Commercial acoustic devices (1)
- Computersimulation (1)
- Computertomographie (1)
- Concrete condition monitoring (1)
- Concrete evaluation (1)
- Concrete specimens (1)
- Contrast agent (1)
- Coordination polymers (1)
- Cordierite (1)
- Corrosion (1)
- Crack depth (1)
- Cracks (1)
- Crystal lattice (1)
- DFG (1)
- DNA (1)
- DNA origami (1)
- Damages (1)
- Data base (1)
- Data fusion (1)
- Dauerhaftigkeit (1)
- Diameter (1)
- Diesel particulate filter (1)
- Digital image catalogues (1)
- Diutan gum (1)
- Doktorandentagung (1)
- Dosisleistung (1)
- Dye (1)
- Düngemittelgewinnung (1)
- EBSD (1)
- EBSD pattern (1)
- EC definition (1)
- EU Definition of nanomaterial (1)
- Eignungsprüfung (1)
- Einkoppeleffizienz (1)
- Einzelmolekülmagnete (1)
- Eisen (1)
- Electron Rutherford backscattering (1)
- Elektrochemie (1)
- Elementanalyse (1)
- Emissionsmesskammer (1)
- Emulsions (1)
- Emuslions (1)
- Energiekopplung (1)
- Enriched isotope (1)
- Ermüdung (1)
- Estrogen receptor (ER) (1)
- Estrone (1)
- Extinction coefficient (1)
- FD (1)
- FRET (1)
- Fenton oxidation (1)
- Fermentation (1)
- Ferroelectret (1)
- Flow profiles (1)
- Fluor-Substitution (1)
- Fluorescence Imaging (1)
- Fluorescence label (1)
- Fluorescence labeling (1)
- Fluorescence lifetime (1)
- Fluoreszenz (1)
- Fluoride catalyst (1)
- Focusing (1)
- Fügefestigkeit (1)
- Gas calibration (1)
- Gassensor (1)
- Gasspeicher (1)
- Gene-5 protein (1)
- Geographic differentiation (1)
- Geophysics (1)
- Gesamtcyanid (1)
- Gesteuerte Materialien (1)
- Gold-Katalyse (1)
- Granulated blast furnace slag (1)
- Granulierte Hochofenschlacke (1)
- HPLC (1)
- HPLC-MS/MS (1)
- HPLC/MS/MS technique (1)
- Heterogeneity (1)
- High throughput (1)
- High voltage cable accessories (1)
- Honeycombing (1)
- Hybridoma (1)
- ICP-MS (1)
- IDMS (1)
- Image processing (1)
- Imaging (1)
- Indirect Hard Modeling (IHM) (1)
- Infrared spectroscopy (1)
- Initial hydration (1)
- Inspection of CFRP (1)
- Iron (1)
- Iron-gall ink (1)
- Karak Castle (1)
- Kikuchi diffraction (1)
- Kikuchi pattern (1)
- Klebverbindungen (1)
- Kolloquium Prozessanalytik (1)
- Konvektion (1)
- Koordinationspolymere (1)
- LC-ELISA (1)
- Ladder sequencing (1)
- Laminografie (1)
- Laminography (1)
- Laser-induced breakdown spectroscopy (LIBS) (1)
- Lattice parameter determination (1)
- Lubricated contact (1)
- Luminescence (1)
- MALDI-TOF-MS (1)
- MKW (1)
- Machine learning (1)
- Massenspektrometrie (1)
- Materials characterization (1)
- Matrix effects (1)
- Mehr-Proben-Prüfung (1)
- Mehr-Proben-Prüfverfahren (1)
- Merrifield (1)
- Mesoporöse Träger (1)
- Messsysteme (1)
- Metal ions (1)
- Metal matrix (1)
- Metall (1)
- Metrologie (1)
- MicroRNA (1)
- Microcracking (1)
- Micromechanical differential scheme (1)
- Microplastics (1)
- Mikroplastik (1)
- Misindexing (1)
- Mitigation (1)
- Mo (1)
- Mobiles LIBS (1)
- Molar extinction coefficient determination (1)
- Molecular dynamics simulation (1)
- Molecular machines (1)
- Monoclonal antibodies (1)
- Multiplexing (1)
- Multivariate classification (1)
- Mycoplasma (1)
- Mycotoxins (1)
- NDT (1)
- NEXAFS (1)
- NHS (1)
- NHS-Ester (1)
- NMR-Spektroskopie (1)
- Nanoanalytic (1)
- Nanoscale EDX analysis (1)
- Nanoscale T-SEM (1)
- Natrium (1)
- Near infrared spectroscopy (1)
- Non-destructive testing (1)
- Non-metal determination (1)
- Nondestructive testing (1)
- Nuclear structures (1)
- OBOC library (1)
- Online monitoring (1)
- Online-RFA (1)
- Ophthalmische Schichten (1)
- Optical sensors (1)
- Optische Schichten (1)
- Organic osmolytes (1)
- Orientation noise (1)
- Orientation precision (1)
- PAH (1)
- PAK (1)
- PFA (1)
- PLS-R (1)
- Palimpsests (1)
- Palladium (1)
- Partial discharge (1)
- Particle (1)
- Pattern matching (1)
- Peptide (1)
- Peptide synthesis (1)
- Phase analysis (1)
- Photo-Fenton oxidation (1)
- Photostabilität (1)
- Pigments (1)
- Plasma-Injektion (1)
- Plasma-kompatible Partikel (1)
- Plasmonics (1)
- Platinum (1)
- Polycarboxylate ether (1)
- Polymer beads (1)
- Polymer optical fiber POF (1)
- Polymers (1)
- Polyoxometalates (1)
- Polysaccharides (1)
- Polyvinyl alcohol (1)
- Porosity (1)
- Portland cement (1)
- Powder diffraction (1)
- Primary standards (1)
- Primäres Isotopenreferenzmaterial (1)
- Priority pollutants (1)
- Priority substances (1)
- Process control (1)
- Proficiency testing (1)
- Prozess-Sensoren 4.0 (1)
- Prozessindustrie (1)
- Pseudo symmerty (1)
- Pt catalysts (1)
- Pt–Si layers (1)
- Pull-out test (1)
- Pulse echo technique (1)
- Pyrite (1)
- Quality control tool (1)
- Quality infrastructure (1)
- Qualitätskontrolle (1)
- Quantification (1)
- Quantitative concentration (1)
- Quantummechanical molecular dynamics simulation (1)
- REM-EDX (1)
- RFID based sensors (1)
- RT (1)
- Raman Mikroskopie (1)
- Raman imaging (1)
- Raman microscopy (1)
- Raman-Spektroskopie (1)
- Reaction Monitoring (1)
- Reactive azo dye degradation (1)
- Rebar (1)
- Reference Material (1)
- Referenzmaterialien (1)
- Reflection seismics (1)
- Reinheitsbestimmung (1)
- Reverse time migration (1)
- Rice husk as (1)
- Roadmap (1)
- Rotaxanes (1)
- Röntgenröhre (1)
- SEIRA methodology (1)
- SEM-EDX (1)
- SERS (1)
- SHM (1)
- SPME-GC-MS (1)
- SPPS (1)
- Saffron (1)
- Salsa (1)
- Sample loss (1)
- Scaled boundary finite element method (1)
- Scanning Electron Microscopy (SEM) (1)
- Schwerflüchtige organische Verbindungen (1)
- Security (1)
- Seismic (1)
- Seismics (1)
- Sensitized magnetic nanocatalysts (1)
- Sequencing (1)
- Silicone rubber (1)
- Silk Roas Sites (1)
- Single-cell fusion (1)
- Single-molecule magnets (1)
- Solid-phase peptide synthesis (1)
- Solvothermal syntheses (1)
- Sonden (1)
- Sonderprobenanalytik (1)
- Spike (1)
- Split and mix technology (1)
- Spurenelemente (1)
- Stabilizer (1)
- Standards (1)
- Starch (1)
- Steel slag (1)
- Stress (1)
- Structural health monitoring (1)
- Structure viewer (1)
- Subgroup relationships (1)
- Sulfamethoxazole (1)
- Sulfo-NHS (1)
- Sulfur (1)
- Superplasticizer (1)
- Supplementary cementitious materials (1)
- Surface analysis (1)
- Surface functional groups (1)
- Surfactant (1)
- Sustainability (1)
- Sustainable (1)
- Synchrotron (1)
- Synchrotron XRD (1)
- Synchrotron measurements (1)
- TKD (1)
- TPH (1)
- TSA (1)
- Tagungsband (1)
- Tensile test inside a TEM (1)
- Tentagel (1)
- Thermografie (1)
- Thermographie (1)
- Timber (1)
- Time-gated fluorescence detection (1)
- ToF-SIMS (1)
- Total cyanide (1)
- Trace elements (1)
- Transducer (1)
- Transducers (1)
- Transmission Electron Microscopy (TEM) (1)
- Transmissionstarget (1)
- Troubleshooting Samples Analytics (1)
- UV-vis Spectrometry (1)
- Ultrasonic test (1)
- Ultrasound concrete (1)
- Untersuchung von CFK (1)
- Uranine (1)
- Verbundfestigkeit (1)
- Verteilte Sensorik (1)
- Voltammetric electronic tongue (1)
- Volume fraction (1)
- Wall paint (1)
- Water structure (1)
- Wear particle analysis (1)
- Wärmeverluste (1)
- X-ray Fluorescence analysis (1)
- ZfP (1)
- Zugfestigkeit (1)
- absorption (1)
- add-on Funktionen (1)
- ageing (1)
- archaeology (1)
- artificial weathering (1)
- bio-diagnostic (1)
- cold neutrons (1)
- computed tomography (1)
- crystal structures (1)
- degradation (1)
- electrochemical dealloying (1)
- emission (1)
- estrogenic activity (1)
- extraction (1)
- iron embrittlement (1)
- leaching (1)
- maghemite (1)
- metal (1)
- nanoparticles (1)
- nanotechnology (1)
- neutron imaging (1)
- neutron instrumentation (1)
- nutritional supplements (1)
- oxidation state (1)
- pore structure (1)
- rubber (1)
- serine-protease inhibitor (1)
- sporting track (1)
- ssNMR spectroscopy (1)
- structural information (1)
- surface modification (1)
- upconverting nanoparticles (UCNPs) (1)
Eingeladener Vortrag
- nein (23)
Gold nanoparticles (AuNPs) can catalyze the decolorization of organic dyes in the presence of sodium borohydride (NaBH4), which can be utilized for sensitive optical signaling. Here, we monitor the catalytic reduction of a fluorescent substrate, exemplarily chosen uranine, by AuNPs serving as nanocatalysts by absorption and fluorescence spectroscopy. Dye reduction is accompanied by dramatic changes in the absorption and fluorescence properties of uranine. As proposed reaction mechanism, we assume electron transfer between uranine and NaBH4 through the AuNPs nanocatalysts which is currently investigated also by time-resolved fluorescence and detailed spectroscopic studies of the influence of pH, NaBH4, and AuNPs on these effects. As ultimate goal, a model reporter platform with colorimetric andfluorometric signaling is anticipated for the detection of different analytes by coating AuNPs with affinity ligands such as antibodies and aptamers and and special separation methods.
A novel synthetic strategy toward highly fluorinated BODIPY dyes with exceptional photostabilities relying on sustainable gold catalysis has been developed. A key to the tailored pyrrole precursors is the gold catalysis performed in ionic liquids as the reaction medium, allowing a facile recycling of the catalysts. The dyes prepared are well-matching with the spectral windows of popular rhodamine dyes and possess high brightness while showing a distinctly higher photostability than the rhodamines especially in aprotic solvents.
Als schweizweit einziger Hersteller produzierte die Gesellschaft der Ludwig von Roll'schen Eisenwerke seit den 1870er Jahren granulierte Hochofenschlacke. Im Blashochofen von Choindez im Schweizer Jura wird bis Mitte der 1920er Jahre Bohnerz aus dem Delsberger Becken, das kontemporär publizierten Analysen zufolge als Spuren- bzw. Schwermetalle Titan, Chrom, Blei und Vanadium enthält, zu grauem Roheisen verhüttet. In zementgebundenen Mörtelmischungen des 19. und frühen 20. Jahrhunderts aus verschiedenen Regionen der Schweiz finden sich neben reliktischen Hüttensandsplittern vereinzelt bis zu fünfhundert Mikrometer große scharze Kugeln mit grünlichem Schimmer, wohl nicht gemahlener Schlackensand. Deren mittels Ramanmikroskopie (Phasenbestand) und energiedispersiver Röntgenspektroskopie am Rasterelektronenmikroskop (Elementanalytik) ermittelte Mineralogie ergibt in Form von Plattnerit PbO2, Rutil TiO2 und vermitlich Chromit Fe(II)Cr2O4 bzw. Nichromit (Ni,Co,Fe(II))(Cr,Fe(III),Al)2)4 Übereinstimmungen mit den nur die Elementzusammensetzung berücksichtigenden historischen Resultaten. Ebenfalls im Zusammenhang mit dem das Bohnerz begleitenden Boluston samt Huppererde zu sehen sind die Minerale Coelestin SrSO4 und Zirkon ZrSiO4, des Weiteren der Siliciumcarbidpolymorph Moissanit SiC als Reaktionsprodukt von Quarzsand und Brennstoff. Die Kohärenz zwischen um die Jahrhundertwende durchgeführten Analysen von Rohmaterial als auch Ofenbruch aus dem in Choindez betriebenen Hochofen und den in diesem Beitrag diskutierten Resultaten moderner analytischer Methoden spricht für den Gebrauch von granulierter Schlacke aus dem Hause Ludwig von Roll als Mörtelzuschlag. Die Hüttensandkörner, eigentlich latent hydraulisch, sind aufgrund der fehlenden Aufbereitung zu grob für eine effektive Hydratation und deshalb trotz reaktiver Glasphase und Klinkermineralien (Belit Ca2SiO4 und Monocalciumaluminat CaAl2O4) intakt in der Bindemittelmatrix erhalten.
Gravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes to the purity of the solid materials they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Unit. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project called SIB09 Primary standards for challenging elements, a reference solution of molybdenum was prepared directly from the respective metal with a relative expanded uncertainty associated with the mass fraction of Urel(w) < 0.05 %. A highly accurate and precise ICP OES and MC-ICP-MS method was developed to assist with the preparation and as a dissemination tool.
The concreting of prefabricated concrete structures can lead to insufficient bonding or even to remaining cavities. Honeycombs (aggregate clusters without cement) represent potential weakening of the structure and need to be detected non-destructively. In our study we tested the capability of ground penetrating radar (GPR) techniques for this purpose. We applied GPR in reflection mode and zero-offset profiling (ZOP) transmission mode on a precast concrete twin wall with built-in honeycombs. GPR measurements were performed as two channel measurement with ground coupled antennas with centre frequencies of 1.5 GHz and 2.6 GHz mounted to an automated scanner system.
Our findings show that ZOP transmission measurements are a more efficient method to detect voids in reinforced concrete structures compared to reflection mode measurements. This holds for both the effort needed for the measurement and the evaluation as well as the validity of the data. Honeycombs (basically representing voids) are usually characterized by strongly reduced amplitudes and earlier arrivals of the transmitted wave.
The concreting of prefabricated concrete structures can lead to insufficient bonding or even to remaining cavities. Honeycombs (aggregate clusters without cement) represent potential weakening of the structure and need to be detected non-destructively. In our study we tested the capability of ground penetrating radar (GPR)techniques for this purpose. We applied GPR in reflection mode and zero-offset profiling (ZOP) Transmission mode on a precast concrete twin wall with built-in honeycombs. GPR measurements were performed as twochannel measurement with ground coupled antennas with centre frequencies of 1.5 GHz and 2.6 GHz mounted to an automated scanner system.
Our findings show that ZOP transmission measurements are a more efficient method to detect voids in reinforced concrete structures compared to reflection mode measurements. This holds for both the effort needed for the measurement and the evaluation as well as the validity of the data. Honeycombs (basically representing voids) are usually characterized by strongly reduced amplitudes and earlier arrivals of the transmitted wave.
Die quantitative Bestimmung der Haftfestigkeit von Beschichtungen ist von entscheidender Bedeutung sowohl für die Entwicklung als auch für die Qualitätssicherung. In einer Vergleichsstudie zur Haftfestigkeit von optischen und ophthalmischen Schichten wurde mit Hilfe der Zentrifugentechnologie der Einfluss verschiedener Parameter (Substratdicke, Oberflächenvorbehand-lung, Haftvermittler) auf die Haftfestigkeit optischer Schichten auf silikatischen und ophthalmischer Schichten auf polymeren Substraten untersucht.
Zur Bestimmung der Haftfestigkeit in der physikalisch korrekten Dimension Kraft pro Fläche im Stirnabzug stehen die Ein-Proben-Prüfung mit der Zugprüfmaschine und die Mehr-Proben-Prüfung mittels Zentri- fugentechnologie zur Verfügung. Die Zentrifugentechnologie wurde ausgewählt, da die Prüfung von bis zu acht Proben unter nahezu identischen Versuchsbedingungen und somit eine statistisch gesicherte Bestimmung der Haftfestigkeit möglich sind.
Es konnte nachgewiesen werden, dass die Substratdicke einen erheblichen Einfluss auf die gemessene Haftfestigkeit hat. Dies entspricht den Erwartungen, da es sich bei der Haftfestigkeit um eine System- eigenschaft des Schicht-Substrat-Systems handelt. Bei den Delaminationsbrüchen (DF) konnte zwischen Delamination des metallischen Reflektors (DF-R) und Delamination des Dielektrikums (DF-D) unter- schieden werden. Im Fall hinreichender Haftfestigkeit der Beschichtung traten auch Adhäsionsbrüche am Interface zum und Kohäsionsbrüche im Klebstoff auf. Nachfolgende Untersuchungen werden sich mit alternativen Klebstoffen und weiterentwickelten Fügestrategien befassen.
High resolution in situ monitoring of the initial cement hydration influenced by organic admixtures
(2015)
Numerous admixtures are used in the building practice to customize the properties of the cement paste during application. The influences of admixtures on the course of cement hydration and formation of hydrate phases have to be considered. Polycarboxylate ether (PCE) based polymeric superplasticizers (SPs) are known to retard the setting of the cement paste. The extent of the retardation differs depending on the molecular structure of the SP. Additionally, the presence of a stabilizing agent (SA) in the cement paste has a retarding side effect on the setting. The initial cement hydration processes and the detailed mechanisms of the retardation influenced by PCEs, as well as their interactions with particular SAs, are insufficiently understood. Up to now, only the results of phenomenological studies were taken into account to describe this retardation process. A detailed structure analysis monitoring the change of the phase composition during the hydration was never applied. Both SP and SA affect the adsorption of the sulphate ions on the clinker particles, causing changes in the formation of ettringite during the initial hydration, and are therefore a crucial part of the setting process itself. Here, the initial hydration of cement influenced by the interaction of SP and SA was monitored in situ by synchrotron X-ray diffraction. The high time resolution of the measurements allowed a continuous detection of the hydrates formed. The hydration was followed from the starting point of water addition and for couple of hours afterwards. The hydration of the levitated cement pellets containing starch as SA was initialized by adding aqueous solutions of different commercial SPs. Changes in the ettringite formation were detected in comparison to the reference hydration of pure cement.
CONRAD-2 is an imaging instrument using low-energy (cold) neutrons. The instrument is installed at the end of a curved neutron guide which avoids the direct line of sight towards the reactor core. This ensures a very low background of high-energy neutrons and. photons at the sample position. The cold neutron beam provides a wavelength range which is suitable for phase-and diffraction-contrast imaging such as grating interferometry and Bragg edge mapping. The instrument is well suited for high resolution imaging due to the high efficiency of the very thin scintillators that can be used for the detection of cold neutrons. An instrument upgrade was performed recently as a part of an upgrade program for the cold neutron instrumentation at HZB. The parameters of the instrument as well as some research highlights will be presented.
Microorganisms accumulate molar concentrations of compatible solutes like ectoine to prevent proteins from denaturation. Direct structural or spectroscopic information on the mechanism and about the hydration shell around ectoine are scarce. We combined surface plasmon resonance (SPR), confocal Raman spectroscopy, molecular dynamics simulations, and density functional theory (DFT) calculations to study the local hydration shell around ectoine and its influence on the binding of a gene-S-protein (G5P) to a single-stranded DNA (dT(25)). Due to the very high hygroscopicity of ectoine, it was possible to analyze the highly stable hydration shell by confocal Raman spectroscopy. Corresponding molecular dynamics simulation results revealed a significant change of the water dielectric constant in the presence of a high molar ectoine concentration as compared to pure water. The SPR data showed that the amount of protein bound to DNA decreases in the presence of ectoine, and hence, the protein-DNA dissociation constant increases in a concentration-dependent manner. Concomitantly, the Raman spectra in terms of the amide I region revealed large changes in the protein secondary structure. Our results indicate that ectoine strongly affects the molecular recognition between the protein and the oligonudeotide, which has important consequences for osmotic regulation mechanisms.
Aufgrund der natürlichen und vom Menschen verursachten Heterogenität von Böden erfordert der Erhalt und die Verbesserung ihrer Fruchtbarkeit durch landwirtschaftliche Bewirtschaftungsmaßnahmen sorgfältig geplante Ent-scheidungen, die auf einer detaillierten Erfassung der Bodeneigenschaften und einem vertieften Verständnis der Bodenprozesse beruhen. Es ist bekannt, dass die konventionelle, flächen-einheitliche Bewirtschaftung Ertragsver-luste durch zu geringe Bewirtschaftungsintensität (z. B. Düngung) auf einen Teil der Fläche verursacht, während andere Teile des Feldes zu hohe Dosen erhalten und es dadurch zu Verschwendung von Ressourcen und zu Um-weltbelastungen kommt. Trotz der Verfügbarkeit von Technologien für ortsspezifische Düngung ist die Akzeptanz ortsspezifischer Bewirtschaftung (Precision Agriculture) in der Praxis noch gering. Ein wesentlicher Grund dafür ist das Fehlen von kostengünstigen Methoden zur Erfassung der bewirtschaftungsrelevanten Bodenmerkmale. So-wohl für die elementanalytische Untersuchung von Böden als auch für die Untersuchung von Ausgangsmaterialien (z.B. Klärschlammaschen) für ihre Verwendung als Dünger ist eine zuverlässige Analytik und Prozessüberwachung erforderlich.
Mycotoxins are secondary metabolites of fungi which have diverse detrimental effects on humans, animals and crops. Traceable worldwide in foods and animal feeds, these contaminants cause manifold diseases and extensive economic losses. Therefore, European legislation set maximum levels of distinct mycotoxins to minimize the risks for the buying public. But standardized food analysis techniques fail to detect masked mycotoxins, whose research increasingly moves to the fore in recent years. They are formed from detoxification metabolism of plants as well as from fungi, which conjugate for example with glucosides or dihexosides. All masked mycotoxins have one thing in common: They are not detectable with standard methods, thereby contributing to the overall exposure and pose an additional health risk for the consumer.
The dissertation work will focus on the following potential new group of masked toxins. Food safety relevant mycotoxins like zearalenone and ochratoxin A possess one or more 1,3-dicarbonyl moieties. Latter are principally able to form thermodynamically stable chelate complexes with metal cations. First investigations at BAM showed interactions between zearalenone and copper ions and it is conceivable that they possibly build a complex. Our main focus is now to identify, characterize and quantify 1,3-dicarbonyl mycotoxin metal complexes as potential candidates within the group of conjugated mycotoxins.
We will simulate processes of biotransformation and identify distinct metabolites by electrochemistry coupled to liquid chromatography/mass spectrometry (EC-HPLC-MS). The obtained knowledge contributes to a better understanding of masked mycotoxins and an improved monitoring of foods and feeds, to ensure food safety.
Introduction to PowderCell
(2015)
In this paper we present the results of imaging studies of ancient Egyptian metallic artifacts using micro-Computed Tomography (micro-CT). Micro-CT is a non-destructive imaging method with high spatial resolution, which enables the examination of the internal structure of objects. It is thus especially suitable for the investigation of cultural heritage and archaeological findings, when it is not possible to sample or difficult to manipulate the object. Using specialized software for 3D visualization and segmentation, data sets of two objects were analyzed. We gained a clear view of the inner structure of a metallic archaeological artifact from the necropolis of Abusir el-Meleq, which is believed to be very ancient in the Egyptian archaeological context (from the Predynastic Era), and were able to distinguish its different omponents under the thick layers of external concretions. These components give hints about the production technology of the object. We also investigated the contents of a closed metal box found near Abusir dated to the Late/Greco-Roman Period. The identified Content corresponds either to sediments or to mineral remains of the original content of the box. Both artifacts are from excavations conducted in Egypt and are part of the archeological collection of the Ägyptisches Museum und Papyrussammlung in Berlin.
In order to estimating the amount and kind of emissions from polymeric sporting tracks a laboratory test was developed in BAM that combines artificial weathering and subsequent batch and column tests [1, 2, 3]. The goal consisted in nvestigating a possible change of emissions into soil and groundwater of a new sporting ground as a function of ageing and egradation of the system. At various stages of the weathering, the samples were removed and subjected to especially designed column extraction tests for the solid samples. Both these extracts and the accumulated rainwater run-off of the weathering device were subjected to analytical tests of their ingredients. The overall aim of the test consisted in developing ontrollable, reproducible, and standardisable conditions and methods of investigation that would allow an estimation of the emissions in the course of outdoor application of about five years.
LIBS is on the step from a laboratory application to on-site analysis. A validated mobile LIBS-system for on-site application on building materials is under development at BAM in cooperation with industrial partners (system developers and companies), who will use this technique for investigation on building structures like bridges and parking decks. The system is designed to measure the content of harmful species like chlorine, sulfur or alkalis, to give the engineer a tool for the estimation of the condition of concrete structures and for quality assurance during concrete repair work on-site. In these work results of on-site measurements on a chloride contaminated bridge are shown. Further work will focus on providing guidelines to establish LIBS as a standard procedure for chemical investigations of building materials.
Online NMR spectroscopy is an excellent tool to study complex reacting multicomponent mixtures and gain process insight and understanding. For online studies under process conditions, flow NMR probes can be used in a wide range of temperature and pressure. This paper compiles the most important aspects towards quantitative process NMR spectroscopy in complex multicomponent mixtures and provides examples. After NMR spectroscopy is introduced as an online method and for technical samples without sample preparation in deuterated solvents, influences of the residence time distribution, pre-magnetization, and cell design are discussed. NMR acquisition and processing parameters as well as data preparation methods are presented and the most practical data analysis strategies are introduced.
Für die Prüfung von Leichtbaustrukturen ist in den letzten Jahren ein vermehrter Einsatz der Luftultraschallprüfung zu verzeichnen. Insbesondere eignet sich Luftultraschall für die Prüfung von Faserkunststoffverbunden und hybrider Werkstoffverbunde, die ihre Anwendung in der Automobilindustrie und Luftfahrt finden. Für den Bau von marktüblichen Luftultraschall-Wandlern werden Piezokomposite mit Anpassschichten versehen. Ihre Herstellung ist allerdings sehr anspruchsvoll und die erreichbaren Signal-Rausch-Abstände sind für viele Prüfprobleme als noch nicht ausreichend einzustufen. Zwecks gesteigerter Effizienz beim Schallübertrag in die Luft wurden Luftultraschall-Sender und -Empfänger aus zellulärem Polypropylen entwickelt. Dieses piezoelektrische Material ist aufgrund seiner geringer Dichte und seiner sehr geringen Schallgeschwindigkeit an die niedrige akustische Impedanz der Luft deutlich besser angepasst, als die üblicherweise verwendeten Anpassschichten. Letztere können bei Polypropylen-Wandlern daher gänzlich vermieden werden.
In diesem Beitrag wird Luftultraschall-Prüfung an zwei verschiedenen CFK-Testkörpern vorgestellt: an einer Platte mit T-Stringern aus dem Seitenleitwerk eines Flugzeugs und an einer Platte mit künstlich eingebrachten Fehlern. Es wurde mit unterschiedlichen planaren und fokussierenden Wandlern geprüft. Marktübliche Wandler mit Anpassschichten wurden mit den selbstentwickelten Wandlern aus zellulärem Polypropylen verglichen. Der Signal-Rausch-Abstand und die laterale Auflösung wurden sowohl im Prüfaufbau mit senkrechter Einschallung als auch mit Schrägeinschallung gemessen. Die Ergebnisse zeigen, dass die Schrägeinschallung zwar den Signal-Rauschabstand erhöht, aber die laterale Auflösung verschlechtern kann.
The intention of this compilation of articles was to introduce brand-new developments in the field of chemical imaging which have not been discussed in previous review articles. These include the design of new sensor nanomaterials based on photon uponversion crystals which convert near-infrared excitation light into sensor signals in the visible wavelength range highlighted by Christ and Schäferling. Sun, Ungerböck and Mayr describe the state of the art in oxygen imaging in microreactors and microfluidic devices. Miniaturized sensors for the imaging of oxygen, pH and temperature in microchips, microfluidic platforms and microbioreactors are reviewed by Pfeiffer and Nagl. Furthermore, Dmitriev and Papkovsky present a critical assessment of the applicability of probes for intracellular oxygen sensing.
I hope these articles provide an interesting insight into advanced luminescent sensor materials and the applications of optical micro- and nanosensors in fluorescence imaging today and will be inspiring for the reader. Finally, I would like to thank all authors and referees for spending their time to enable this collection of articles.
This project aims to develop capacity to produce certified reference materials (CRMs) for environmental analysis by transferring know-how between the partners and combining their skills to focus on environmental CRM production. The production process includes good manufacturing practices for processing materials, method development, the validation and application of homogeneity, stability and characterisation tests, the calculation of individual uncertainties (between-unit inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. An inter laboratory comparison registered as a EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
Reliable analysis of chemical indicators in water, sediment and soil samples for the purpose of environmental pollution assessment poses one of the greatest analytical challenges, having in mind the complexity of sample matrix and low concentrations of pollutants. Organics (pesticides, PAHs, PCBs, etc.) and heavy metals (Hg, Cd, Ni, Pb and As) represent target parameters. Laboratories performing sampling and tests in this field regulated by respective EU directives [1], need strong support in terms of providing them with appropriate matrix CRMs enabling the process of quality control. NMIs and DIs with proven metrological capabilities for the production and certification of such materials are necessary for the provision of quality data. This project is aiming to develop capacity to produce CRMs for environmental analysis by transferring the theoretical and practical know-how between the partners and combining their skills to focus on environmental CRM production in accordance with ISO Guide 34 [2]. Production process includes good manufacturing practices for processing materials, method development and validation for homogeneity, stability and characterisation tests, characterisation of selected analytes together with additional information about matrix constituents, the calculation of individual uncertainties (between units inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. Inter laboratory comparison registered as EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
Zur Bestimmung von Arzneimittelrückständen in Oberflächengewässern wird häufig die LC-MS/MS als Methode der Wahl eingesetzt. Obwohl sich dieses Nachweisverfahren durch eine hohe Empfindlichkeit und Selektivität auszeichnet, gibt es vor allem bei geringen Substanzkonzentrationen häufig störende Einflüsse durch Matrixeffekte. Diese Matrixeffekte können unterschiedliche Ursachen haben.
Einige Matrixeffekte werden am Beispiel des Wirkstoffs Carbamazepin erläutert. Carbamazepin wird durch Kläranlagen nur partiell aus dem Abwasser entfernt und ist im Spurenbereich auch noch im Trinkwasser nachzuweisen. Wenn für die LC-MS/MS wasserbasierte Anteile in der mobilen Phase genutzt werden, befinden sich trotz Verwendung einer Labor-Reinstwasseranlage in der mobilen Phase noch kleinste Konzentrationen von Carbamazepin, welche einen Blindwert im unteren ppt-Bereich verursachen.
Weitere Matrixeffekte treten durch die unterschiedliche Qualität der Oberflächenwasserproben auf. Koelutionen von weiteren Inhaltstoffen zeitgleich mit dem Zielanalyten führen zu einer Diskriminierung des Meßsignals. Verbindungen, die den gleichen Massenübergang bei nahezu identischer Retentionszeit zeigen, erfordern eine reproduzierbare chromatographische Vortrennung oder die Wahl einer alternativen HPLC-Säule.
Untergrundspeicher für Roh- und Abfallstoffe gewinnen zunehmend an Bedeutung. Verwendet werden sie vor allem für Stoffe wie Erdgas, Wasserstoff, Erdöl und neuerdings auch für Kohlen-stoffdioxid (CO2). Diese Stoffe werden meist unter Druck in Kavernen- oder Porenspeichern einge-lagert. Die Speicher dienen einerseits zum Ausgleich von Ungleichgewichten zwischen Ange-bot/Förderung und Nachfrage/Verbrauch und zur Erhöhung der Versorgungssicherheit. Anderer-seits bestehen Konzepte Abfallstoffe oder Gefahrstoffe für die Umwelt (aktuell CO2-Speicherung) dort für lange Zeiträume einzulagern. Mit den Einlagerungsstoffen verbunden ist ein signifikantes Gefahrenpotential für Mensch und Umwelt, falls es trotz aller Sicherheitsmaßnahmen zu einem unkontrollierten Austritt dieser Stoffe kommen sollte. Daher kommt dem Monitoring derartiger Untergrundspeicher und den darüber befindlichen Bodenstrukturen eine extrem hohe Bedeutung zu.
Ein hochaktuelles Beispiel, das die Überwachung entsprechender Bodenflächen fordert, ist die unterirdische CO2-Speicherung im Rahmen der CO2-Abscheidung und -Speicherung (Carbon Dioxide Capture and Storage, CCS). CCS gilt als wichtige Brückentechnologie der Energiewirtschaft und wird weltweit vorangetrieben, während die Sicherheit von Bevölkerung und Biosphäre noch kont-rovers diskutiert wird. Auch die EU setzt auf CCS und gibt in der EU-Richtlinie 2009/31 als Ziel-setzung bis 2015 vor, 15 Pilotanlagen zu bauen und in Betrieb zu nehmen. Als Bedingung für die Genehmigung der CO2-Speicherung ist explizit die Überwachung der Speicheranlagen durch Monito-ring vorgeschrieben, wobei die technisch besten Lösungen zum Einsatz kommen sollen.
Das zu entwickelnde Messsystem adressiert neben den o.g. Anwendungsfeldern weitere, bei denen insbesondere die Emission von Gasen ein Risiko für Mensch und Umwelt darstellt oder wirt-schaftlichen Schaden verursachen kann. Hierzu zählen die Überwachung von Abfalldeponien, Ge-fahrgutlagerstätten, kontaminierten Altlastengebieten, Moor-, Torf-, Kohleflözen (präventive Branderkennung) und geodynamisch aktiven Regionen. Auch moderne Fördertechnologien, wie das Hot-Dry-Rock-Verfahren (HDR) zur Energiegewinnung durch Einpressen von überkritischem CO2 in den Erdkörper, das die Beweglichkeit eines Gases mit der Dichte einer Flüssigkeit kombiniert und Wärmeaustausch im Erdinneren bewirkt, bergen das Risiko unkontrollierter Gasemissionen und bedürfen der umfassenden Überwachung.
The increasing pollution of terrestrial and aquatic ecosystems with plastic debris, which leads to the accumulation of microscopic plastic particles of still unknown fate, is an upcoming problem of our time. In order to monitor the degree of contamination and to understand the underlying processes of degradation and internalization of plastic debris, analytical methods are urgently needed, which help to identify and quantify microplastics. Currently, expensive collected and purified materials enriched on filters are investigated by (micro) infrared spectroscopy (FTIR). Few studies using micro-Raman spectroscopy have been published as well. In contrast to FTIR, Raman spectroscopy can handle wet samples, but it suffers from interference of fluorescent materials. Both micro-FTIR- and micro-Raman, always include time consuming scanning and mapping procedures followed by the manual inspection and measurement of selected particles.
Troubleshooting Samples Analytics:
Impurities in products: unexpected & unwanted occurrence, unknown identity, analytical method unclear, often various analytical methods, necessary, short response time important (< 1 d), benefits: allocation of its source within hours safes cost
• Investigations planned, coordinated and documented by TSA team
• Variety of analytical methods available
The paper addresses beech wood as well as vulcanized fiber and discusses the results obtained when using acoustic emission and thermography as non-destructive testing techniques along tensile and load increase fatigue tests to characterize the wooden material’s behavior under increasing fatigue loads to get enhanced information regarding the fatigue behavior of both materials. Reference is mainly made to the materials’ anisotropic and microstructural behavior and what implications this has with respect to the materials’ strength. The influence of moisture is discussed, as well as parameters that may deserve monitoring in the sense of structural health monitoring to be applied in timber structures in general.
Sixteen Ayyubid-Mamluk glazed pottery sherds were analyzed in order to identify and characterize the elemental composition to determine their provenance. The tested sherds were collected from the historical site of Karak Castle, southern Jordan.
Chemical analysis for the sixteen samples has been carried out using Synchrotron Radiation X-ray Fluorescence Spectrometry (SR-XRF) Technique. Furthermore, the semiquantitative analysis of the elements Fe – Cu – Zn – Br – Rb – Sr – Y – Zr – Nb – Mo – Pd – Ag – Cd and Pb has been performed for the samples based on Principal Component Analysis (PCA) and hierarchical Cluster Analysis with Bray-Curtis in order to define grouping of different glazed pottery by obtaining information on their similarity and clustering. The results of chemical analysis provided persuasive evidence that the Karak Castle pottery sherds have at least three different sources of provenance.
Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. This involves also jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty of this method is to predict the column diameter and its material strength. Here, we present two-dimensional finite-difference numerical simulation results of a promising non-destructive quality assurance testing tool to evaluate the diameter of jet grout columns. This approach incorporates crosshole and downhole seismic measurements. Preliminary tests showed that this tool is applicable under real site conditions.
The design of sample flow cells, commonly used in online analytics and especially for medium resolution NMR spectroscopy (MR-NMR) in low magnetic fields, was experimentally and theoretically investigated by 1H-NMR and numerical simulations. The flow pattern was characterised to gain information about the residence time distribution and mixing effects. Both 1H-NMR imaging and spectroscopy were used to determine the characteristics of flow cells and their significance for on-line measurements such as reaction monitoring or hyphenated separation spectroscopy. The volume flow rates investigated were in the range from 0.1 to 10 ml/min, typically applied in the above mentioned applications. When compared to those commonly used in high-field NMR, the special characteristics of flow cells for MR-NMR were revealed by various NMR experiments and compared with CFD simulations. The influence of the design of the inlet and outlet on the flow pattern was investigated as well as the effect of the length of the cell. For practical use, a numerical estimation of the inflow length was given. In addition, it was shown how experiments on the polarisation build-up revealed insight into the flow characteristics in MR-NMR.
Hydroformylation represents an important homogeneous catalyzed process, which is widely used within chemical industry. Usually applied with simple alkenes like Propene and Butene aldehydes obtained from alkenes >C6 are relevant intermediates in production of plasticizers, surfactants and polymers. Today the active catalyst species is often based on valuable Rhodium complexes in aqueous solution. This implies the problem of limited water solubility of the reactands, which is acceptable for short chain lengths, but states a problem in case of higher alkenes. Along with that efficient separation and recycling of the catalyst becomes more complicated. There are different approaches tackling this problem, e.g., by using of salt formation in the BASF process or downstream distillation within the Shell process
The Collaborative Research Center InPROMPT aims to establish a novel process concept for the hydroformylation of long-chained olefins, using a rhodium complex as catalyst in the presence of syngas. Recently, the hydroformylation in micro-emulsions, which allows for the efficient recycling of the expensive rhodium catalyst, was found to be feasible. However, the temperature and concentration sensitive multi-phase system demands a continuous observation of the reaction to achieve an operational and economically feasible plant operation. For that purpose, we tested the potential of both NMR and Raman spectroscopy for process control assistance. The lab-scale experiments were supported by sampling for off-line GC-analysis as reference analytics. The results of the NMR experiments will be part of another contribution.
This paper reflects recent progress in the field of fluorescent polymer optical fiber sensors (F-POF) for partial discharge (PD) detection in high voltage (HV) cable accessories using optical-only PD detection by coincidence single photon counting. In experiments with artificial PD sources these sensors show the ability to detect optical emissions from picocoulomb-level PDs in a real-scale model of a translucent high voltage cable accessory. False positives (caused by detector noise) are efficiently suppressedwhile maintaining sufficient sensitivity,even when the sensor is located in an unfavorable position.
Polyglycerol (PG) coated polypropylene (PP) films were synthesized in a two-step approach that involved plasma bromination and subsequently grafting hyperbranched polyglycerols with very few amino functionalities. The influence of different molecular weights and density of reactive linkers were investigated for the grafted PGs. Longer bromination times and higher amounts of linkers on the surface afforded long-term stability. The protein adsorption and bacteria attachment of the PP-PG films were studied. Their extremely low amine content proved to be beneficial for preventing bacteria attachment.
Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance). This showed that modern NMR equipment is also suitable for the observation of hydrocarbon samples in the expanded fluid phase or gas phase. Since Quantitative NMR spectroscopy (qNMR) is a direct ratio method of analysis without the need of calibration it was used to determine impurities in appropriate liquid and liquefied hydrocarbon isomers up to C6, which are used for preparation of primary gas standards, e.g., natural gas or exhaust gas standards. At the same time it is possible to yield structural information with a minimum of sample preparation. Thus, cross contaminations between different isomers of the observed hydrocarbons and their (NMR-active) impurities can be identified and quantified.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example the method has beneficially been used by National Measurement institutes for recent CCQM comparisons including the CCQM–K55 series of purity studies.
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of 4 individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
The need for technological progress in bio-diagnostic assays of high complexity requires both fundamental research and constructing efforts on nano-scaled assay recognition elements that can provide unique selectivity and design-enhanced sensitivity features. Nanoparticle induced sensitivity enhancement and its application related to multiplexed capability Surface-Enhanced InfraRed Absorption (SEIRA) assay formats are well suitable for these purposes. The potential of diverse fluorophore–antibody conjugates, being chemisorbed onto low-cost gold nanoparticulate SEIRA substrates, has been explored with respect to their spectral discriminability. These novel biolabels deliver molecular SEIRA fingerprints that have been successfully analyzed by both uni- and multivariate analyzing tools, to discriminate their multiplexing capabilities. We show that this robust spectral encoding via SEIRA fingerprints opens up new opportunities for a fast, reliable and multiplexed high-end screening in biodiagnostics.
Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. One commonly applied method is jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty linked with this method is to predict the resulting column diameter and its material strength. In this paper we illustrate the application of a newly developed non-destructive quality assurance testing tool used to determine the diameter of jet grout columns. This approach incorporates standard crosshole and downhole seismic measurements. To demonstrate its effectiveness, we tested the new approach within two-dimensional finite-difference numerical simulations. Additional field tests showed that this tool is also applicable in real site conditions. For this purpose, three jet grout columns were produced with different process parameters in a depth between 3.0 and 10 m. The evaluated diameters were within 1.0 and 1.5 m, slightly deviating from the previously predicted range by the jet grouting contractor. Moreover, we were able to detect the base of the columns at 10 m depth with no significant difficulties. On the other hand, unsaturated, partly unconsolidated sands between ground water level and surface considerably affected the seismic data, hence complicating the detection of the top of the columns.
Lewis and Brønsted sites were quantified in a series of weak acidic hydroxylated magnesium fluorides by Fourier transform infrared spectroscopy (FTIR) and solid state nuclear magnetic resonance spectroscopy (NMR) with pyridine as probe molecule. Molar extinction coefficients, which are necessary for quantitative FTIR measurements, were calculated by an easy approach. It utilizes the fact that both signals, used for the quantification by FTIR, are caused by the same deformation vibration mode of pyridine. Comparison of quantitative FTIR experiments and quantification by NMR shows that concentrations of acidic sites determined by FTIR spectroscopy have to be interpreted with caution. Furthermore, it is shown that the transfer of molar extinction coefficients from one catalyst to another may lead to wrong results. Molar extinction coefficients and concentrations of acidic sites determined by FTIR spectroscopy are affected by grinding and probably the particle size of the sample. High temperature during FTIR experiments has further impact on the quantification results.
N-Hydroxysuccinimide (NHS) esters are the most important activated esters used in many different bioconjugation techniques, such as protein labelling by fluorescent dyes and enzymes, surface activation of chromatographic supports, microbeads, nanoparticles, and microarray slides, and also in the chemical synthesis of peptides. Usually, reactions with NHS esters are very reliable and of high yield, however, the compounds are sensitive to air moisture and water traces in solvents. Therefore, the quantification of NHS would be a very helpful approach to identify reagent impurities or degradation of stored NHS esters. No robust and sensitive method for the detection of NHS (or the more hydrophilic sulfo-NHS) has been reported yet. Here, a chromatographic method based on HILIC conditions and UV detection is presented, reaching a detection limit of about 1 mg L-1, which should be sensitive enough for most of the applications mentioned above. Exemplarily, the hydrolytic degradation of a biotin-NHS ester and a purity check of a fluorescent dye NHS ester are shown. An important advantage of this approach is its universality, since not the structurally variable ester compound is monitored, but the constant degradation product NHS or sulfo-NHS, which avoids the necessity to optimize the separation conditions and facilitates calibration considerably.
Laser-induced breakdown spectroscopy (LIBS) is a combination of plasma generation on the sample surface by a high power laser pulse and optical emission spectroscopy (OES). It is a direct measurement method without an extensive sample preparation. Concrete is a multi phase system. With LIBS it is possible to distinguish the different phases and based on that to correlate the chloride content to the cement mass. This is done by scanning the surface with a resolution of up to 0.1 mm. The high measurement frequency of 100 Hz or even higher allows the in-situ visualization of the chloride content over the measured area. With a calibration a quantification of chloride concentration is possible. As an example the LIBS measurement on a 50 mm by 70 mm area with a resolution of 0.5 mm and the visualization of the chloride distribution takes only 10 minutes. Additionally it is possible to evaluate the carbonation depth from the same measurement. Examples of practical application to determine the chloride-to-cement-content on concrete samples are presented. The possibilities and the limitations of LIBS are discussed.
In- and quasielastic neutron scattering is employed to investigate both the vibrational density of states and the molecular dynamics of two homologous discotic liquid crystals (DLC) with different length of the alkyl side chain based on a triphenylene derivate. For both compounds characteristic low frequency excess contributions to the vibrational density of states are found. Therefore it is concluded that these liquid crystals show a glass-like behaviour. Elastic scans further show that in these materials a rich molecular dynamics takes place.
For absorption processes with fluctuating feed gas compositions it is vital to continuously adjust
the operation point to achieve energy efficiency. In this contribution a Raman-based advanced
process control (APC) is introduced for the absorption of carbon dioxide (CO2) using an aqueous
solution of monoethanolamine (MEA). The APC is based on a Raman spectroscopic analysis of
the composition and CO2 load of the scrubbing liquid and a non-linear model predictive control
(NMPC) to adjust the scrubbing liquid cycle. In addition, an outer real-time optimization loop is
set in place to update the set points for the absorption process depending on the current feed gas composition minimizing the energy consumption of the process. Implementation and testing of the APC have been carried out in a mini-plant at TU Berlin. During a plant operation of more than 160 hours robustness and stability of the APC were shown.
Recommendations on a Revision of the EC Definition of Nanomaterial Based on Analytical Possibilities
(2015)
In October 2011 the European Commission (EC) published a "Recommendation on the definition of nanomaterial" (2011/696/EU), to promote consistency in the interpretation of the term "nanomaterial" for legislative and policy purposes in the EU. The EC NM Definition includes a commitment to its review in the light of experience and of scientific and technological developments. This review is ongoing in 2015 and as a contribution to the review the Joint Research Centre of the European Commission (JRC) has already developed a series of three scientific-technical reports with the title: “Towards a review of the EC Recommendation for a definition of the term nanomaterial” which provides to the EC policy services science-based options on how the definition could be revised or supported with additional guidance.
The overarching nature and wide scope of the EC NM Definition, as it does not exclude a priori any particulate material regardless the state, form and size, creates many analytical challenges in its imple-mentation for all stakeholders, including enterprises and regulators.
The NanoDefine project has as core objective to support the implementation of the EC NM Definition. In this report key aspects of the EC NM Definition are addressed, with the goal to improve the implement-ability of the EC NM Definition. These aspects are presented and discussed based on the results of two years of research performed within the framework of the project. As a result this report assesses how well the requirements of the EC NM Definition can be fulfilled with currently available analytical possi-bilities. It presents recommendations and options on a revision of the EC NM Definition to improve the implementability of the definition based on currently available analytical possibilities, according to the state of the art of mid-2015.
Of the technical issues considered in this report, the following seem to deserve the most attention in terms of clarification of the definition and/or provision of additional implementation guidance:
The term ‘external dimension’.
A clear definition of 'External dimension' should be included in the text of the EC NM definition and more precise guidance on what is considered as an external dimension and how to properly character-ise it should be provided.
The ‘number based particle size distribution‘.
The EC NM Definition uses a threshold related to the number based size distribution of particles. Yet most of the easily available techniques provide a mass-, volume- or scattered light intensity-based size distribution which needs to be converted into a number based distribution to be used for regulatory pur-poses. A specific guidance on the conditions under which these methods can be used to identify a na-nomaterial by employing appropriate quantity or metrics conversion should be provided.
The ‘polydispersity‘ and ‘upper size limit‘
Polydispersity is a challenge for the measurement of particle size distribution for the EC NM definition, specifically for materials with high polydispersity index and broad size distribution especially when the volume or mass of the fraction containing particles below 100 nm is very small. Therefore a dedicated guidance should be provided that allows applying an upper size limit in measurements and particle statistics.
This paper describes the production and characteristics of the nanoparticle test materials prepared for common use in the collaborative research project NanoChOp (Chemical and optical characterization of nanomaterials in biological systems), in casu suspensions of silica nanoparticles and CdSe/CdS/ZnS quantum dots (QDs). This paper is the first to illustrate how to assess whether nanoparticle test materials meet the requirements of a "reference material" (ISO Guide 30, 2015) or rather those of the recently defined category of "representative test material (RTM)" (ISO/TS 16195, 2013). The NanoChOp test materials were investigated with small-angle X-ray scattering (SAXS), dynamic light scattering (DLS), and centrifugal liquid sedimentation (CLS) to establish whether they complied with the required monomodal particle size distribution. The presence of impurities, aggregates, agglomerates, and viable microorganisms in the suspensions was investigated with DLS, CLS, optical and electron microscopy and via plating on nutrient agar. Suitability of surface functionalization was investigated with attenuated total reflection Fourier transform infrared spectrometry (ATR-FTIR) and via the capacity of the nanoparticles to be fluorescently labeled or to bind antibodies. Between-unit homogeneity and stability were investigated in terms of particle size and zeta potential. This paper shows that only based on the outcome of a detailed characterization process one can raise the status of a test material to RTM or reference material, and how this status depends on its intended use.
Here, we summerize our efforts concerning new design concepts and examples for fluorescence standards that can provide traceability to radiometric units and present a first step towards a toolbox of fluorescence standards, currently consisting of:
i) A first set of liquid fluorescence standards enables the determination of a broad variety of fluorescence parameters was developed and certified by BAM and is distributed by Sigma-Aldrich.
ii) Ready-to-use, glass-based fluorescence standards for instrument performance validation (IPV) and determination instrument-to-instrument variations can also be used as wavelength standard for fluorescence instruments with low requirements on spectral resolution and allow monitoring of temporal changes of the wavelength-dependent spectral responsivity.
iii) Novel calibration tools and validation concepts for microarray-based platforms used in molecular diagnostics and food safety control.
iv) We currently develop reference materials, which can be used as reliable quantum yield standards for relative methods for the determination of QY and can be valuable in the evaluation of the performance and sources of uncertainty of absolute, standard-free methods using e.g. integrating spheres.
Ultrasonic echo testing is widely used in non-destructive testing in civil engineering to investigate concrete structures, to measure thickness, and to locate and characterise built-in components or inhomogeneities. Currently, synthetic aperture focusing techniques are mostly used for imaging. These algorithms are highly developed but have some limitations. For example, it is not possible to image the lower boundary of built-in components like tendon ducts or vertical reflectors. We adopted reverse time migration for non-destructive testing in civil engineering in order to improve the imaging of complicated structures in concrete. By using the entire wavefield, including waves reflected more than once, there are fewer limitations compared to synthetic aperture focusing technique algorithms. As a drawback, the required computation is significantly higher than that for the techniques currently used. Simulations for polyamide and concrete structures showed the potential for non-destructive testing. The simulations were followed by experiments at a polyamide specimen. Here, having acquired almost noise-free measurement data to test the algorithm, we were able to determine the shape and size of boreholes with sufficient accuracy. After these successful tests, we performed experiments at a reinforced concrete foundation slab. We obtained information from the data by reverse time migration, which was not accessible by traditional imaging. The imaging of the location and structure of the lower boundary of the concrete foundation slab was improved. Furthermore, vertical reflectors inside the slab were imaged clearly, and more flaws were found. It has been shown that reverse time migration is a step forward in ultrasonic testing in civil engineering.