Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (148)
- Zeitschriftenartikel (71)
- Beitrag zu einem Tagungsband (57)
- Posterpräsentation (37)
- Sonstiges (9)
- Dissertation (3)
- Buchkapitel (2)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Forschungsdatensatz (1)
Sprache
- Englisch (221)
- Deutsch (106)
- Russisch (2)
- Mehrsprachig (1)
Schlagworte
- Thermography (51)
- NDT (40)
- Super resolution (34)
- Zerstörungsfreie Prüfung (24)
- Thermografie (22)
- Laser thermography (21)
- Human Factors (19)
- Non-destructive testing (18)
- LIBS (16)
- NMR (14)
Organisationseinheit der BAM
- 8.0 Abteilungsleitung und andere (330) (entfernen)
Paper des Monats
- ja (3)
Eingeladener Vortrag
- nein (148)
Pulse thermography (PT) has proven to be a valuable non-destructive testing method to identify and quantify defects in fiber-reinforced polymers. To perform a quantitative defect characterization, the heat diffusion within the material as well as the material parameters must be known. The heterogeneous material structure of glass fiber-reinforced polymers (GFRP) as well as the semitransparency of the material for optical excitation sources of PT is still challenging. For homogeneous semitransparent materials, 1D analytical models describing the temperature distribution are available.
Here, we present an analytical approach to model PT for laterally inhomogeneous semitransparent materials.We show the validity of the model by considering different configurations of the optical heating source, the IR camera, and the differently coated GFRP sample. The model considers the lateral inhomogeneity of the semitransparency by an additional absorption coefficient. It includes additional effects such as thermal losses at the samples surfaces, multilayer systems with thermal contact resistance, and a finite duration of the heating pulse. By using a sufficient complexity of the analytical model, similar values of the material parameters were found for all six investigated configurations by numerical fitting.
Industrial Radiology is used for volumetric inspection of industrial objects. By penetration of these objects (typically weldments, pipes or castings) with X-ray or Gamma radiation the 3D-volume is projected onto a 2D image detector. The X-ray film is the oldest radiographic image detector and still in wide use in industry. The industrial X-ray film systems used today differ from these used in medicine. Medical film systems are described well in the literature, but industrial film systems not. So we start with a description of the properties and standards for industrial film systems. The requirements on image quality are defined by several standards and can be verified with different image quality indicators (IQIs). They describe the ability of the human being to detect small and low contrast indications in a noisy image background. The essential parameters for digital industrial radiology are described.
Since about 30 years electronic image detectors are gradually replacing the industrial film. These detectors are based on storage phosphor imaging plates in combination with Laser scanners (“Computed Radiography”, CR) or a variety of different digital detector arrays (DDA). Typical applications of CR and DDAs are discussed as well as new possibilities by digital image processing, which is enabled by the computer based image handling, processing and analysis.
Defect recognition in CFRP components using various NDT methods within a smart manufacturing process
(2018)
The manufacturing process of carbon fiber reinforced polymer (CFRP) components is gaining a more and more significant role when looking at the increasing amount of CFRPs used in industries today. The monitoring of the manufacturing process and hence the reliability of the manufactured products, is one of the major challenges we need to face in the near future. Common defects which arise during manufacturing process are e.g. porosity and voids which may lead to delaminations during operation and under load. To find irregularities and classify them as possible defects in an early stage of the manufacturing process is of high importance for the safety and reliability of the finished products, as well as of significant impact from an economical point of view. In this study we compare various NDT methods which were applied to similar CFRP laminate samples in order to detect and characterize regions of defective volume. Besides ultrasound, thermography and eddy current, different X-ray methods like radiography, laminography and computed tomography are used to investigate the samples. These methods are compared with the intention to evaluate their capability to reliably detect and characterize defective volume. Beyond the detection and evaluation of defects, we also investigate possibilities to combine various NDT methods within a smart manufacturing process in which the decision which method shall be applied is inherent within the process. Is it possible to design an in-line or at-line testing process which can recognize defects reliably and reduce testing time and costs? This study aims to show up opportunities of designing a smart NDT process synchronized to the production based on the concepts of smart production (Industry 4.0). A set of defective CFRP laminate samples and different NDT methods were used to demonstrate how effective defects are recognized and how communication between interconnected NDT sensors and the manufacturing process could be organized.
Es wird ein Verfahren zur Charakterisierung der Beständigkeit und Langzeitstabilität von additiv gefertigten Kunststoff-Bauteilen vorgestellt. Dabei sollen die Prüfkörper über 2000 Stunden künstlich bewittert und währenddessen die Änderungen der Eigenschaften der Bauteile zerstörungsfrei untersucht werden. Die Erkenntnisse dienen für die Entwicklung einer Strategie für eine Qualitätskontrolle von additiv gefertigten Kunststoffteilen.
In flash thermography, the temperature transient is strongly influenced by the temporal shape of the heating pulse for samples with high thermal diffusivity or very thin samples. Here, we present a closed phenomenological approximation of the temporal shape of pulses of Xe-flash lamps. It is a non-stitched solution, has a simple Laplace transform and is suitable for different lamps and energy settings. It is demonstrated that simulated temperature transients, based on this approximation, are well consistent with experimental data.
Active thermography with flash and halogen light excitation is used as a method for non-destructive testing of 3D-printed polymer components. Test specimens with artificial defects have been generated, using laser sintering and fused layer modeling. These test specimens have been investigated in different measurement configurations with both excitation methods. Afterwards, the different measurement conditions were compared regarding their capability to detect the defects. Furthermore, advanced analysis methods are used, to fully exploit the capabilities of these techniques.
Additively manufactured test specimens made of polyamide 12 (PA 12) by Laser Sintering (LS) as well as of acrylnitril-butadien-styrol (ABS) by Fused Layer Modeling (FLM), were tested with active thermography. For this, two different excitation methods (flash and impulse excitation) were used and compared, regarding the suitability for the detection of constructed and imprinted defects. To increase the quality of the thermograms, data processing methods like thermal signal reconstruction (TSR) and Fourier-Transformation were applied. Furthermore, the long-term stability of the probes towards environmental stress, like UV-radiation, heat, water contact and frost is being investigated in the presented project with artificial weathering tests.
In order to test their suitability different non-destructive methods were performed to inspect a GFRP plate with artificial defects. These defects were manufactured by means of thin PTFE sheets inserted between two plies in three different depth. The inspection methods were microwave reflection, flash thermography and phased array ultrasonics, all applied to the same specimen. Selected results are shown for all methods demonstrating opportunities and limits of the particular inspection methods. The achieved detection limits and further application aspects are compared directly to provide a useful information for the planning of inspection tasks.
Systematic errors in the evaluation of uncorrected data from thermographic lock-in measurements
(2018)
Lock-in thermography (LT) is based on the correct evaluation of phase differences between the temperature oscillations at different surface regions of the object under test during periodic heating. Since the usual heating procedures contain a DC component, the actual heating pattern achieved is not harmonic. This causes systematic deviations when phase differences are determined by means of harmonic analysis, e.g. with FFT analysis. The resulting errors depend clearly on the ratio between DC and AC amplitude, which is demonstrated at simulated and experimentally recorded temperature transients. Further experimental LT data obtained by different oscillating energy inputs showed a variety of possible shapes of transients with different DC components.
Systematic errors in the evaluation of uncorrected data from thermographic lock-in measurements
(2018)
Lock-in thermography (LT) is based on the correct evaluation of phase differences between the temperature oscillations at different surface regions of the object under test during periodic heating. Since the usual heating procedures contain a DC component, the actual heating pattern achieved is not harmonic. This causes systematic deviations when phase differences are determined by means of harmonic analysis, e.g. with FFT analysis. The resulting errors depend clearly on the ratio between DC and AC amplitude, which is demonstrated at simulated and experimentally recorded temperature transients. Further experimental LT data obtained by different oscillating energy inputs showed a variety of possible shapes of transients with different DC components.
In the field of optically excited thermography, flash lamps (impulse shaped planar heating) and halogen lamps (modulated planar heating) have become established for the specific regimes of impulse and lock-in thermography. Flying-spot laser thermography is implemented by means of a rasterized focused laser, e. g. for crack detection (continuous wave operation) and photothermal material characterization (high-frequency modulated). The availability of novel technologies, i. e. fast and high-resolution IR cameras, brilliant innovative light sources and high-performance data acquisition and processing technology will enable a paradigm shift from stand-alone photothermal and thermographic techniques to uniform quantitative measurement and testing technology that is faster and more precise. Similar to an LED array, but with irradiance two orders of magnitude higher, a new type of brilliant laser source, i. e. the VCSEL array (vertical-cavity surface-emitting laser), is now available. This novel optical energy source eliminates the strong limitation to the temporal dynamics of established light sources and at the same time is spectrally clearly separated from the detection wavelength. It combines the fast temporal behavior of a diode laser with the high optical irradiance and the wide illumination area of flash lamps. In addition, heating can also be carried out in a structured manner, because individual areas of the VCSEL array can be controlled independently of each other. This new degree of freedom enables the development of completely new thermographic NDT methods.
The detection of cracks before the failure is highly significant when it comes to safety-relevant structures. Crack detection in metallic samples at high surface temperature is one of the challenging situation in manufacturing industries. Laser thermography has already proved its detection capability of surface cracks in metallic samples at room temperature. In this work a continuous wave (CW) laser use to generate a laser, which is using to scan the metal surface with notch. The corresponding heat distribution on the surface monitored using infrared thermal (IR) camera. A simplified 3D model for laser thermography is developed and validated with experimental results. A dedicated image processing algorithm developed to improve the detectability of the cracks. To understand the dependency of surface temperature, laser power, laser scanning speed etc. in defect detection, we carried out parametric studies with our validated model. Here we report the capability of laser thermography in crack detection at elevated temperature.
Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test specimen. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration.
We present current activities with kilowatt-class high-power laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages.
Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz, see Fig.1. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration.
Using the one-dimensional solution to the thermal heat diffusion equation together with the absorptance of the material which is illuminated with a harmonically modulated light source, we can calculate the temperature oscillation at the surface of a solid. As a second step, we calculate the corresponding oscillation of the total thermal emission using Stefan-Boltzmann law as a first order approximation and taking into account the emissivity of the material. Within this framework we can calculate the minimal irradiance of a light source necessary to provoke a measurable signal within a thermographic camera at a noise equivalent temperature difference (NETD) of 30 mK. In Fig. 2 this relationship is displayed for a wide spectrum of modulation frequencies and for a number of different light sources scaled to the same electrical input power and illumination area. Using this figure, it is now easily possible to analyze the range of materials to be tested using lock-in thermography, since only the materials (dotted lines) below the irradiance-vs-frequency curves (solid lines) are heated in excess of the camera’s NETD. This figure clearly shows that laser sources considerably increase the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in texting.
We present current activities with kilowatt-class high-power laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages.
Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz, see Fig.1. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration.
Using the one-dimensional solution to the thermal heat diffusion equation together with the absorptance of the material which is illuminated with a harmonically modulated light source, we can calculate the temperature oscillation at the surface of a solid. As a second step, we calculate the corresponding oscillation of the total thermal emission using Stefan-Boltzmann law as a first order approximation and taking into account the emissivity of the material. Within this framework we can calculate the minimal irradiance of a light source necessary to provoke a measurable signal within a thermographic camera at a noise equivalent temperature difference (NETD) of 30 mK. In Fig. 2 this relationship is displayed for a wide spectrum of modulation frequencies and for a number of different light sources scaled to the same electrical input power and illumination area. Using this figure, it is now easily possible to analyze the range of materials to be tested using lock-in thermography, since only the materials (dotted lines) below the irradiance-vs-frequency curves (solid lines) are heated in excess of the camera’s NETD. This figure clearly shows that laser sources considerably increase the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in texting.
We present current activities with kilowatt-class high-power laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages.
Using an infrared camera for radiometric imaging allows the contactless temperature measurement of multiple surface pixels simultaneously. From the measured surface data, a sub-surface structure, embedded inside a sample or tissue, can be reconstructed and imaged when heated by an excitation light pulse. The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The ground-breaking concept of super-resolution can be transferred from optics to thermographic imaging.
Quantification of impact damages in CFRP and GFRP structures with thermography and ultrasonics
(2018)
For the quantification of impact damage in CFRP and GFRP structures, first passive thermography measurements have been performed at the front and rear side of the test specimens during low velocity impact load. After loading, the damaged structures have been investigated non-destructively with active thermography with flash excitation and with step heating and with two different ultrasonic methods (phased array and air coupled ultrasonics). The damage sizes quantified with all methods are evaluated and compared. In addition, the depth of the greatest damage inside the different test specimens is analysed.
Half-Cell-Potential Mapping (HP) is the most popular non-destructive testing (NDT) method for the detection of active corrosion in reinforced concrete. HP is influenced by parameters such as moisture and chloride gradients in the component. The sensitivity to the spatially small, but dangerous pitting is low. In this study we show how additional measurement information can be used with multi-sensor data fusion to improve the detection performance and to automate data evaluation. The fusion is based on supervised machine learning (SML). SML are methods that recognize relationships in (sensor) data based on given labels. We use SML to distinguish "defective" and "intact" labeled areas in our dataset. It consists of 18 measurement - each contains HP, ground radar, microwave moisture and Wenner resistance data. Exact labels for changing environmental conditions were available in a laboratory study on a reinforced concrete slab, which deteriorated controlled and accelerated. The deterioration progress was monitored continuously and corrosion was generated targeted at a predefined location. The detection results are quantified and statistically evaluated. The SML results shows a significant improvement over the best single method (HP).
Photon counting detectors (PCD) offer new possibilities for x-ray micro computed tomography (CT) in the field of non-destructive testing. For large and/or dense objects with high atomic numbers the problem of scattered radiation and beam hardening severely influences the image quality. This work shows that using an energy discriminating PCD based on CdTe allows to address these problems by intrinsically reducing both the influence of scattering and beam hardening.
Based on 2D-radiographic measurements it is shown that by energy thresholding the influence of scattered radiation can be reduced by up to in case of a PCD compared to a conventional energy-integrating detector (EID).
To demonstrate the capabilities of a PCD in reducing beam hardening, cupping artefacts are analyzed quantitatively. The PCD results show that the higher the energy threshold is set, the lower the cupping effect emerges. But since numerous beam hardening correction algorithms exist, the results of the PCD are compared to EID results corrected by common techniques. Nevertheless, the highest energy thresholds yield lower cupping artefacts than any of the applied correction algorithms.
As an example of a potential industrial CT application, a turbine blade is investigated by CT. The inner structure of the turbine blade allows for comparing the image quality between PCD and EID in terms of absolute contrast, as well as normalized signal-to-noise and contrast-to-noise ratio. Where the absolute contrast can be improved by raising the energy thresholds of the PCD, it is found that due to lower statistics the normalized contrast-to-noise-ratio could not be improved compared to the EID. These results might change to the contrary when discarding pre-filtering of the x-ray spectra and thus allowing more low-energy photons to reach the detectors.
Despite still being in the early phase in technological progress, PCDs already allow to improve CT image quality compared to conventional detectors in terms of scatter and beam hardening reduction.
Bei der Trocknung von Gesteinen vermindert sich der Anteil des Wasservolumens im Porenraum, der als Sättigung bezeichnet wird. Mit abnehmender Sättigung sinkt die elektrische Leitfähigkeit des Gesteins. Die Abhängigkeit der elektrischen Leitfähigkeit von der Sättigung wird durch ein Potenzgesetz entsprechend der 2. Archie-Gleichung beschrieben: log(#CHR:sigma_LOWER#)=n log(S<sub>w</sub>), wobei n der Sättigungsexponent ist. Bei der Trocknung von Gesteinen muss beachtet werden, dass die Wasserleitfähigkeit mit abnehmender Sättigung zunimmt, da die Konzentration der im Wasser gelösten Salze ansteigt. Das hat zur Folge, dass die bei Trocknungsexperimenten bestimmten Sättigungsexponenten deutlich kleiner sind als bei Verdrängungsexperimenten (z.B. Wasser durch Öl) mit gleichbleibender Wasserleitfähigkeit. Bei der Spektral(en) Induzierten Polarisation wird die komplexe elektrische Leitfähigkeit des Gesteins als Funktion der Frequenz betrachtet. Für den Real- und Imaginärteil der elektrischen Leitfähigkeit werden unterschiedliche Sättigungsexponenten bestimmt.
Wir haben an zwei Sandsteinproben (Langenauer und Gravenhorster Sandstein) und einem Baumberger Kalksandstein Trocknungsexperimente durchgeführt. Die Sättigung wurde schrittweise von 100 % bis auf 10 % reduziert. In jeder Sättigungsstufe wurden an den Proben die Spektren der komplexen elektrischen Leitfähigkeit aufgezeichnet. Unsere Experimente zeigen, dass die Sättigungsexponenten für den Imaginärteil der komplexen elektrischen Leitfähigkeit mit 1,23 bis 1,59 deutlich größer sind als die des Realteils mit Werten zwischen 0,41 und 0,90. Dieser Unterschied resultiert aus der Tatsache, dass der Imaginärteil der Leitfähigkeit weniger stark mit zunehmender Wasserleitfähigkeit ansteigt als der Realteil. Für den Realteil der elektrischen Leitfähigkeit wird nach der 1. Archie-Gleichung ein linearer Zusammenhang zwischen Wasserleitfähigkeit und Gesteinsleitfähigkeit erwartet. Der Anstieg des Imaginärteils mit der Wasserleitfähigkeit kann mit einem Potenzgesetz mit einem Exponenten zwischen 0.1 und 0.62 beschrieben werden. Unsere Experimente zeigen, dass der Imaginärteil der elektrischen Leitfähigkeit wesentlich deutlicher auf die Austrocknung von Gesteinen reagiert und damit ein wirksamer Indikator zur Überwachung von Sättigungsänderungen sein kann.
We present an in situ triple coupling of synchrotron X-ray diffraction with Raman spectroscopy, and thermography to study milling reactions in real time. This combination of methods allows a correlation of the structural evolution with temperature information. The temperature information is crucial for understanding both the thermodynamics and reaction kinetics. The reaction mechanisms of three prototypical mechanochemical syntheses, a cocrystal formation, a C@C bond formation (Knoevenagel condensation), and the formation
of a manganese-phosphonate, were elucidated. Trends in the temperature development during milling are identified. The heat of reaction and latent heat of crystallization of the product contribute to the overall temperature increase. A decrease in temperature occurs via release of, for example, water as a byproduct.
Solid and liquid intermediates are detected. The influence of the mechanical impact could be separated from temperature effects caused by the reaction.
Potentialfeldmessung (PM) ist die beliebteste Methode der Zerstörungsfreien Prüfung (ZfP) zur Lokalisierung von aktiver Betonstahlkorrosion. PM wird durch Parameter wie z. B. Feuchtigkeits- und Chloridgradienten im Bauteil beeinflusst, so dass die Sensitivität gegenüber der räumlich sehr begrenzten, aber gefährlichen Lochkorrosion gering ist. Wir zeigen in dieser Studie, wie zusätzliche Messinformationen mit Multisensor-Datenfusion genutzt werden können, um die Detektionsleistung zu verbessern und die Auswertung zu automatisieren. Die Fusion basiert auf überwachtem maschinellen Lernen (ÜML). ÜML sind Methoden, die Zusammenhänge in (Sensor-) Daten anhand vorgegebener Kennzeichnungen (Label) erkennen. Wir verwenden ÜML um „defekt“ und „intakt“ gelabelte Bereiche in einem Multisensordatensatz zu unterscheiden. Unser Datensatz besteht aus 18 Messkampagnen und enthält jeweils PM-, Bodenradar-, Mikrowellen-Feuchte- und Wenner-Widerstandsdaten. Exakte Label für veränderliche Umweltbedingungen wurden in einer Versuchsanordnung bestimmt, bei der eine Stahlbetonplatte im Labor kontrolliert und beschleunigt verwittert. Der Verwitterungsfortschritt wurde kontinuierlich überwacht und die Korrosion gezielt erzeugt. Die Detektionsergebnisse werden quantifiziert und statistisch ausgewertet. Die Datenfusion zeigt gegenüber dem besten Einzelverfahren (PM) eine deutliche Verbesserung. Wir beschreiben die Herausforderungen datengesteuerter Ansätze in der zerstörungsfreien Prüfung und zeigen mögliche Lösungsansätze.
For assuring the safety and reliability of components and constructions in energy applications made of fiber-reinforced polymers (e.g., blades of wind turbines and tidal power plants, engine chassis, flexible oil and gas pipelines) innovative non-destructive testing methods are required. Within the European Project VITCEA complementary methods (shearography, microwave, ultrasonics and thermography) have been further developed and validated. Together with partners from the industry, test specimens have been constructed and selected on-site containing different artificial and natural defect artefacts. As base materials, carbon and glass fibers in different orientations and layering embedded in different matrix materials (epoxy, polyamide) have been considered. In this contribution, the validation of flash and lock-in thermography to these testing problems is presented. Data analysis is based on thermal contrasts and phase evaluation techniques. Experimental data are compared to analytical and numerical models. Among others, the influence of two different types of artificial defects (flat bottom holes and delaminations) with varying diameters and depths and of two different materials (CFRP and GFRP) with unidirectional and quasi-isotropic fiber alignment is discussed.
Es wird ein Verfahren zur Charakterisierung der Beständigkeit und Langzeitstabilität von additiv gefertigten Kunststoff-Bauteilen vorgestellt. Dabei sollen die Prüfkörper über 2000 Stunden künstlich bewittert und währenddessen die Änderungen der Eigenschaften der Bauteile zerstörungsfrei untersucht werden.
Structured illumination using high-power diode lasers generates a two-dimensional interference of thermal waves. In addition, the sources and the sample are moving relative to each other. Using different configurations, we investigate the validity of the temporal and spatial superposition principle of the heat diffusion equation for these cases both experimentally and by numerical-analytical modelling. Furthermore, we investigate the potential of this approach for non-destructive testing.
Angetrieben durch Digitalisierung und die sogenannte Industrie 4.0 steigt die Erwartungshaltung gegenüber der Nutzung von Sensorik. Die Unsicherheit, Widersprüchlichkeit und Redundanz separat verarbeiteter einzelner Quellen soll durch die synergetische Zusammenführung heterogener Datensätze überwunden werden. Dabei steht der zunehmenden Aufgabenkomplexität eine ebenso zunehmende Verfügbarkeit an Sensoren, Daten und Rechenleistung gegenüber.
Der Begriff Datenfusion fasst Ansätze zusammen, die Daten zu abstrakteren, aber besser verständlichen Informationen verarbeiten. Die Fusion ist Kernbestandteil effektiver Assistenzsysteme und beweist in vielzähligen Aufgaben - von militärischen Anwendungen über Flug- und Fahrassistenzsysteme, bis in den Heimbereich – ihr großes Potenzial. Durch die wachsende Automatisierung bei der Messdatenerfassung wird Datenfusion auch in der industriellen Qualitätsprüfung und –sicherung zunehmend attraktiver.
Der Vortrag gibt einen Überblick über den breiten Themenkomplex und widmet sich dabei im Theorieteil speziell der Fragen, welche Informationen in multivariaten Datensätzen stecken und wie sie extrahiert werden können. Anschließend wird ein Beispiel für die erfolgreiche Anwendung zur zerstörungsfreien Prüfung von Betonbauteilen vorgestellt. Der dargestellte Datensatz ist klein, heterogen, hochdimensional und unausgeglichen. Anhand von Algorithmen mit unterschiedlicher Leistungsfähigkeiten hinsichtlich Anpassungsfähigkeit und Invarianz gegenüber Höherdimensionalität wird erläutert welche Prozesse zur Verbesserung der Informationsqualität nötig sind.
Mit additiven Fertigungsverfahren hergestellte Bauteile und Produkte aus Kunststoffen werden zunehmend nicht mehr nur als Prototypen, sondern als voll funktionsfähige Bauteile und Produkte gefertigt. Bedingt durch die Fertigungsprozesse und den schichtweisen Aufbau resultieren physikalische Materialeigenschaften, die stark von den Fertigungsparametern abhängen und zudem anisotrop sind. Von den Fertigungsparametern werden auch die Oberflächeneigenschaften beeinflusst, sodass zu erwarten ist, dass sich die Beständigkeit gegenüber äußeren Umwelteinflüssen bei additiv gefertigten Bauteilen von der konventionell gefertigter unterscheiden kann. Nachfolgend wird daher die Entwicklung eines Qualitätssicherungskonzeptes basierend auf spektroskopischen und zerstörungsfreien Prüfverfahren vorgestellt, in dem der Alterungsprozess von mittels Fused Deposition Modelling (FDM) und mittels Lasersintering (LS) hergestellten Probekörpern untersucht wird.
Mit additiven Fertigungsverfahren hergestellte Bauteile und Produkte aus Kunststoffen werden zunehmend nicht mehr nur als Prototypen, sondern als voll funktionsfähige Bauteile und Produkte gefertigt. Bedingt durch die Fertigungsprozesse und den schichtweisen Aufbau resultieren physikalische Materialeigenschaften, die stark von den Fertigungsparametern abhängen und zudem anisotrop sind. Von den Fertigungsparametern werden auch die Oberflächeneigenschaften beeinflusst, sodass zu erwarten ist, dass sich die Beständigkeit gegenüber äußeren Umwelteinflüssen bei additiv gefertigten Bauteilen von der konventionell gefertigter unterscheiden kann. Nachfolgend wird daher die Entwicklung eines Qualitätssicherungskonzeptes basierend auf spektroskopischen und zerstörungsfreien Prüfverfahren vorgestellt, in dem der Alterungsprozess von mittels Fused Deposition Modelling (FDM) und mittels Lasersintering (LS) hergestellten Probekörpern untersucht wird.
Der Umfang der durch Impacts in Faserverbundmaterialien erzeugten Schäden ist abhängig von der Energie des Impacts, von der Zusammensetzung und dem Aufbau der Faserverbundwerkstoffe und von der Geometrie der Bauteile und hier im Wesentlichen von der Dicke des Bauteils. Der zerstörungsfreie Nachweis dieser Schädigungen kann sowohl mit Ultraschallverfahren als auch mit Verfahren der aktiven Thermografie erfolgen. Ein Vergleich der Nachweisempfindlichkeiten dieser Verfahren für die unterschiedlichen Schädigungen wird in diesem Beitrag in Abhängigkeit vom verwendeten Faserverbundwerkstoff (CFK und GFK), der Dicke des Materials und von der Impactenergie durchgeführt. Ergänzt werden die im Anschluss an die Schädigung eingesetzten ZfP-Verfahren mit zeitlich hochaufgelösten Thermografiemessungen, die bereits während des Impacts aufgenommen wurden.
Der Umfang der durch Impacts in Faserverbundmaterialien erzeugten Schäden ist abhängig von der Energie des Impacts, von der Zusammensetzung und dem Aufbau der Faserverbundwerkstoffe und von der Geometrie der Bauteile und hier im Wesentlichen von der Dicke des Bauteils. Der zerstörungsfreie Nachweis dieser Schädigungen kann sowohl mit Ultraschallverfahren als auch mit Verfahren der aktiven Thermografie erfolgen. Ein Vergleich der Nachweisempfindlichkeiten dieser Verfahren für die unterschiedlichen Schädigungen wird in diesem Beitrag in Abhängigkeit vom verwendeten Faserverbundwerkstoff (CFK und GFK), der Dicke des Materials und von der Impactenergie durchgeführt. Ergänzt werden die im Anschluss an die Schädigung eingesetzten ZfP-Verfahren mit zeitlich hochaufgelösten Thermografiemessungen, die bereits während des Impacts aufgenommen wurden.
Among the photothermal methods, full-field thermal imaging is used to characterize materials, to determine thicknesses of layers, or to find inhomogeneities such as voids or cracks. The use of classical light sources such as flash lamps (impulse heating) or halogen lamps (modulated heating) led to a variety of nondestructive testing methods, in particular, lock-in and flash-thermography. In vertical-cavity surface-emitting lasers (VCSELs), laser light is emitted perpendicularly to the surface with a symmetrical beam profile. Due to the vertical structure, they can be arranged in large arrays of many thousands of individual lasers, which allows power scaling into the kilowatt range. Recently, a high-power yet very compact version of such a VCSEL-array became available that offers both the fast timing behavior of a laser as well as the large illumination area of a lamp. Moreover, it allows a spatial and temporal control of the heating because individual parts of the array can be controlled arbitrarily in frequency, amplitude, and phase. In conjunction with a fast infrared camera, such structured heating opens up a field of novel thermal imaging and testing methods. As a first demonstration of this approach, we chose a testing problem very challenging to conventional thermal infrared testing: The detection of very thin subsurface defects perpendicularly oriented to the surface of metallic samples. First, we generate destructively interfering thermal wave fields, which are then affected by the presence of defects within their reach. It turned out that this technique allows highly sensitive detection of subsurface defects down to depths in excess of the usual thermographic rule of thumb, with no need for a reference or surface preparation.
A composite material is a combination of two or more materials with very different mechanical, thermal and electrical properties. The various forms of composite materials, due to their high material properties, are widely used as structural materials in the aviation, space, marine, automobile, and sports industries. However, some defects like voids, delamination, or inhomogeneous fiber distribution that form during the fabricating processes of composites can seriously affect the mechanical properties of the composite material. In this study, several imaging NDE techniques such as: thermography, high frequency eddy current, ultrasonic, x-ray radiography, x-ray laminography, and high resolution x-ray CT were conducted to characterize the microstructure of carbon fiber composites. Then, a 3D analysis was implemented by the destructive technique of serial sectioning for the same sample tested by the NDE methods. To better analyze the results of this work and extract a clear volume image for all features and defects contained in the composite material, an intensive comparison was conducted among hundreds of 3D-NDE and multi serial sections’ scan images showing the microstructure variation.
X-ray scatter imaging is a well-established NDT technique to inspect complex objects using only a single-sided access. We present a specially designed multi-slit scatter camera consisting of several twisted slits which are parallelly arranged in a metal block. The camera projects one image per slit to the digital detector array, where the images are overlaying each other. The aperture is corrected based on a de-convolution algorithm to focus the overlaying projections into a single representation of the object. To achieve high scatter intensities from an object, it is necessary to optimize the parameters of the scatter system by simulation.
The detection of cracks before the failure is highly significant when it comes to safety-relevant structures. Crack detection in metallic samples at high surface temperature is one of the challenging situation in manufacturing industries.
Laser thermography has already proved its detection capability of surface cracks in metallic samples at room temperature. In this work a continuous wave (CW) laser use to generate a laser, which is using to scan the metal surface with notch.
The corresponding heat distribution on the surface monitored using infrared thermal (IR) camera. A simplified 3D model for laser thermography is developed and validated with experimental results. A dedicated image processing algorithm developed to improve the detectability of the cracks. To understand the dependency of surface temperature, laser power, laser scanning speed etc. in defect detection, we carried out parametric studies with our validated model. Here we Report the capability of laser thermography in crack detection at elevated temperature.
The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. We demonstrate this by imaging a line pattern and a star-shaped structure through a metal sheet with a resolution four times better than the width of the thermal point-spread-function. The ground-breaking concept of super-resolution can be transferred from optics to diffusive imaging by defining a thermal point-spread-function similar to the Abbe limit for a certain optical wavelength.
THz-TDS Systeme können zeitaufgelöst die Amplitude der elektrischen Feldstärke E(t) detektieren. Der Vorteil des verwendeten Messprinzips besteht in dem gleichzeitigen Nachweis von Amplitude und Phase des zwischen der Antenne und dem Detektor sich ausbreitenden elektrischen Feldes eines Impulses. Befindet sich im Strahlengang dielektrisches Material, dann ändern sich die Laufzeit (Time of Flight) und Amplitude des Impulses im Vergleich zum freien Strahlengang.
Planare Fehlstellen, wie Risse oder delaminierte Schichten in Kompositen sowie mehrschichtig aufgebaute Dielektrika können als optische Mehrschichtsysteme aufgefasst werden, mit denen sich die beobachteten Transmissions- und Reflektionseigenschaften im THz-Bereich erklären lassen.
Bei Entwicklung eines optischen Schichtenmodells für das jeweilig ausgewählte Schichtensystem lassen sich zeitliche Impulsverläufe in Abhängigkeit von der Schichtenfolge- und deren –dicke berechnen.
Durch den Fit der experimentell gewonnener Daten mit den aus dem Schichtenmodell berechneten Impulssequenzen lassen sich unter Verwendung der Methode der kleinsten Quadrate Schichtdicken oder die Brechungsindizes der einzelnen Schichten im jeweiligen Testobjekt bestimmen. Anhand eines repräsentativen Beispiels wird die Entwicklung des Schichtenmodells erklärt und die erreichten Genauigkeiten zur Bestimmung der Schichtdicken und Brechungsindizes anhand selbst entwickelter Testkörper diskutiert.
Mit Laserlicht kann man eine Materialoberfläche berührungslos und schnell moduliert aufheizen. Dabei entsteht eine stark gedämpfte Wärmewelle, die tief ins Material eindringen kann. Erzeugt und überlagert man solche thermischen Wellen auf kohärente Weise, dann kann man damit versteckte Materialfehler zerstörungsfrei und sehr präzise aufspüren. Sogar eine bildgebende Tomografie ist denkbar.
The determination of chloride is still one of the main tasks for the evaluation of reinforced concrete structures.
The corrosion of the reinforcement induced by the penetrating chlorides is the dominant damage process affecting the lifetime of concrete structures. In the recent years different research groups demonstrated that LIBS can be a fast and reliable method to quantify chlorine in cement-bound materials. Because chlorine in concrete can only occur as solved ions in the pore solution or bound in salts or hydrated cement phases, the detected emission of chlorine can be correlated with the chloride concentration determined e.g. with potentiometric titration. This work inter alia describes the production of reference samples and possible side effects during the production process. Due to transport processes in the porous matrix of the cement a misinterpretation of the concentrations is possible. It is shown how to overcome these effects and higher precisions of the single measurements can be realised. Using the calibration method, blank sample method and noise method, three different ways of calculating the limit of detection (LOD) and limit of quantification (LOQ) are compared. Due to the preparation of the reference samples a precision of the whole calibration model of sx0 = 0.023 wt% is determined.
The validation of the model is based on different test sets, which are varying in their composition
(different Cl-salts, water-to-cement ratios and additives). The determined mean error of the validation is
0.595 ± 0.063 wt%, which is comparable to standardised methods like potentiometric titration, direct potentiometry
or photometry (0.40 ± 0.06 wt%) [1].
Pulse and flash thermography are experimental techniques which are widely used in the field of non-destructive testing for materials characterization and defect detection. We recently showed that it is possible to determine quantitatively the thickness of semitransparent polymeric solids by fitting of results of an analytical model to experimental flash thermography data, for both transmission and reflection configuration. However, depending on the chosen experimental configuration, different effective optical absorption coefficients had to be used in the model to properly fit the respective experimental data, although the material was always the same. Here, we show that this effect can be explained by the wavelength dependency of the absorption coefficient of the sample material if a polychromatic light source, such as a flash lamp, is used. We present an extension of the analytical model to describe the decay of the heating irradiance by two instead of only one effective absorption coefficient, greatly extending its applicability. We show that using this extended model, the experimental results from both measurement configurations and for different sample thicknesses can be fitted by a single set of parameters. Additionally, the deviations between experimental and modeled surface temperatures are reduced compared to a single optimized effective absorption coefficient.
Investigation on Wall Thickness Ranges Using Digital Radiography for Tangential Projection Technique
(2018)
X-ray testing is based on the attenuation of X-rays when passing through matter. Image detectors acquire the X-ray information which is defined by the local penetrated wall thickness of the tested sample. By X-ray absorption in the detector and following read-out and digitization steps a digital image is generated. As detectors a radiographic film and film digitization, a storage phosphor imaging plate and a special Laser scanner (Computer Radiography - CR) or a digital detector array (DDA) can be used. The digital image in the computer can then be further analyzed using many types of image processing. In the presented work the automated evaluation of wall thickness profiles are investigated using a test steel pipe with 9 different wall thicknesses and various X-ray voltages and different filter materials at the tube port and intermediate between object and detector. In this way the influence of different radiation qualities on the accuracy of the automated wall thickness evaluation depending on the penetrated wall thickness of the steel pipe was investigated.
Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised.
Die Voraussetzungen für die Vorhersage der Sichtbarkeit von Bildgüteprüfkörpern (BPK) wurden seit Beginn der kommerziellen Anwendung der technischen Radiographie diskutiert und in diversen nationalen und internationalen Standards festgeschrieben. Diese Fragen werden nach Einführung der digitalen Radiographie und der CT wieder neu diskutiert. Draht BPKs wurden in Deutschland seit 1935 (DIN 1915: 1935) und später in den meisten europäischen Ländern benutzt. In den USA und Frankreich wurden vorzugsweise BPKs mit Löchern verwendet (ASTM E 1025 seit 1984 oder E 1742 seit 1992 bzw. die Vorgängernorm MIL STD-543 seit 1962). Jetzt werden auch die Umrechnungsnormen zur Erkennbarkeit von Draht zu Loch-BPKs in Frage gestellt. ISO 19232-3, der französische RCCM-Kode einerseits und ASTM E 747 und ASME BPVC Section V Tab. T-276 andererseits unterscheiden sich erheblich bei den Anforderungen im Bereich hoher Wandstärken (Hochenergieradiographie). Untersuchungen dazu werden vorgestellt. Mit Einführung der digitalen Detektoren ändern sich auch die Rauschspektren. Durch die Herstellung werden insbesondere bei Speicherfolien "Rauschmuster" eingeprägt, die bei hohen Belichtungsdosen sichtbar werden. Diese veränderten Rauschspektren ergeben auch veränderte Erkennungsparameter für menschliche Bildauswerter. Hierzu wurden an ausgewählten Detektoren MTFs (presampled) und normierte Rauschspektren gemessen. Erweiterte Erkennbarkeits-Formeln zur Vorhersage der Sichtbarkeit von BPKs für Bildauswerter und erste Ergebnisse werden vorgestellt.
Spektren von gepulsten Röntgenquellen wie Blitzröhren, Linearbeschleuniger (LINACs) oder Betatrons lassen sich in der Literatur nicht finden. Eine gängige Lehrmeinung ist, dass sich solche Spektren nicht messen lassen. Deshalb wurden in Zusammenarbeit mit der Goethe-Universität Frankfurt und neuester Messtechnik diese Problematik untersucht. Es wurde ein CeBr3-Szintillator-Kristall mit einem klassischen Photoelektronenvervielfacher (PMT) und einer analogen Übertragungskette verwendet, der über Stunden Integrationszeit nur einen sehr geringen Untergrund detektiert. Als kritischter Punkt stellte sich die geeignete Kollimierung von Quelle und Detektor bei möglichst großem Abstand heraus. Zu diesem Zweck wurde das verwendete 7 MeV-Betatron in einen 3t-Bleibunker betrieben, der ein Austrittsloch von 1 mm für die erzeugte Röntgenstrahlung besaß. Der Detektor wurde mit einem Densimet-Zylinder abgeschirmt. Damit konnte die Bedingung für die Spektroskopie gepulster Quellen erreicht werden: pro Puls darf nur 1 Photon den Detektorkristall erreichen, damit ohne Pile-up seine Energie vermessen werden kann. Trotz schnellster Elektronik war es nicht möglich, mehere Photonen pro Röntgenpuls (beim Betatron ca. 1 Mikrosekunde) spektral richtig aufzulösen. Die gemessenen Spektren zeigen die erwartete Form, wie sie z.B. mit aRTist simuliert werden können.
The transition from X-ray film to digital detectors in radiography is accompanied by an increase of unsharpness due to the larger inherent digital detector unsharpness in comparison to film. The basic spatial resolution of digital detectors (see EN ISO 17636-2) is used today to describe this unsharpness. The geometrical unsharpness of the radiographic projection of object structures onto the detector plane is determined by the focal spot size of the X-ray tube and the magnification. The focal spot size is measured today (see ASTM E 1165) from pin hole camera exposures or edge unsharpness (see ASTM E 2903). The final image unsharpness is a result of a convolution of the geometrical and inherent detector unsharpness function, divided by the magnification factor of the object onto the detector plane. Different approximations of this convolution result in ASTM E 1000 and ISO 17636-2 in different optimum values for the magnification factor for a given focal spot size of a X—ray tube and the basic spatial resolution of the detector. The higher contrast sensitivity, an advantage of digital radiography, compared to film radiography is furthermore improved when using higher X-ray voltages as used with film and smaller focal spots of the X-ray tubes. This allows a higher distance between object and detector resulting in reduced object scatter in the image. The interactions between all these parameters will be discussed and simple rules for practitioners will be derived in this contribution.
Recent developments of photon counting and energy discriminating detectors for radiographic imaging
(2018)
The direct detection of X-ray photons into electrical signals is enabled by usage of highly absorbing photo conducting materials (e.g. CdTe) as detection layer of an underlying CMOS semiconductor X-ray image detector. If the read-out speed is high enough (ca. 50 - 100 ns dead time) single X-ray photons can be counted and their energy measured. Read-out noise and dark image correction can be diminished. By setting energy thresholds, selected energy ranges of the X-ray spectrum can be detected or suppressed. This allows material discrimination or reduction of scattered radiation, which results in an enhanced contrast sensitivity.
Up to now THz-TDS-systems aren’t considered to be nondestructive testing facilities for large scale industrial applications, despite it was proven that they provide a comprehensive set of quality parameters. A practical approach to bring THz-TDS in addition to already existing testing systems into the industrial mainstream is systematic development of future test procedures and test facilities for dielectrics. For this purpose polyeth-ylene test specimen with introduced artefacts were designed, to evaluate the detection sensitivity of Time of Flight measurements based on dielectrics. SAFT reconstructed tomograms are presented which visualize the sizes and location of artificially introduced flaws.
We investigate the pore space of rock samples with respect to different petrophysical parameters using various methods, which provide data on pore size distributions, including micro computed tomography (µ-CT), mercury Intrusion porosimetry (MIP), nuclear magnetic resonance (NMR), and spectral-induced polarization (SIP). The resulting cumulative distributions of pore volume as a function of pore size are compared. Considering that the methods differ with
regard to their limits of resolution, a multiple-length-scale characterization of the pore space is proposed, that is based on a combination of the results from all of these methods.
The approach is demonstrated using samples of Bentheimer and Röttbacher sandstone. Additionally, we compare the potential of SIP to provide a pore size distribution with other commonly used methods (MIP, NMR). The limits of Resolution of SIP depend on the usable frequency range (between 0.002 and 100 Hz). The methods with similar Resolution show a similar behavior of the cumulative pore volume distribution in the verlapping pore size range. We assume that µ-CT and NMR provide the pore body size while MIP and SIP characterize the pore throat size. Our study Shows that a good agreement between the pore radius distributions can only be achieved if the curves are adjusted considering the resolution and pore volume in the relevant range of pore radii. The MIP curve with the widest range in Resolution should be used as reference.
More than 80 representatives of SMEs, industrial companies and research institutes met on September 12 at the workshop "Challenges in Additive Manufacturing: Innovative Materials and Quality Control" at BAM in Adlershof to discuss the latest developments in materials and quality control in additive manufacturing.
In special lectures, researchers, users and equipment manufacturers reported on the latest and future developments in additive manufacturing. Furthermore, funding opportunities for projects between SMEs and research institutions on a national and European level were presented.
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects. Material defects are often simulated by flat-bottom holes (FBH) or grooves. Typically, analytical 1D models are used to determine the defect depth of FBHs, grooves or delaminations. However, these models cannot take into account lateral heat flows, or only to a limited extent (semi-empirical model). They are therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Here, we present an approach for quantitative determination of the geometry of FBH or grooves. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a FBHs or groove and its diameter or width, respectively. The model takes lateral heat flows into account as well as thermal losses. Figure 1 shows the temperature increase of a pulsed thermography measurement at three different locations on the sample. The numerical model is fitted to the experimental data (red lines) to quantify the groove. The numerical simulation matches the experimental data well.
Reliability of NDT is affected by human factors, which have thus far received the least amount of attention in the reliability assessments. With increased use of automation, in terms of mechanised testing (automation-assisted inspection and the corresponding evaluation of data), higher reliability standards are believed to have been achieved. However, human inspectors, and thus human factors, still play an important role throughout this process and the risks involved in this application are unknown. The aim of this study was to explore for the first time the risks associated with mechanised NDT and find ways of mitigating their effects on the inspection performance. Hence, the objectives were to identify and Analyse potential risks in mechanised NDT and devise measures against them. To address those objectives, a risk assessment in form of a Failure Modes and Effects Analysis (FMEA) was conducted. This analysis revealed potential for failure during both the acquisition and evaluation of NDT data that could be assigned to human, technology, and organisation. Since the existing preventive measures were judged to be insufficient to defend the system from identified failures, new preventive measures were suggested.
Other than commonly assumed the relaxation times observed in the electrical low-frequency range (1 mHz – 40 kHz) of natural porous media like sandstones and tuff stones cannot be directly related to the dominant (modal) pore throat sizes, measured (e.g.) with mercury intrusion porosimetry (MIP). Working with a great variety of sandstones from very different origins and featuring great variations in textural and chemical compositions as well as in geometrical pore space properties, we observed that particularly samples with narrow pore throats were characterized by long (low-frequency) relaxations. These, however, can (following the current theories) be rather explained by long “characteristic length scales” in these media or low diffusion coefficients along the electrical double layer. However, there is no straightforward way (or single approved method) of getting reliable numbers for properties such as the lengths of pore throats, the diameter and length of the wide pores and their respective distributions. Consequently we follow a multi-methodical approach and combine the benefits of MIP, micro-computed tomography (µ-CT) and nuclear magnetic resonance (NMR) to achieve much deeper insight due to the different resolutions and sensitivities to either pore constrictions (throats) or wide pores. This helps us to understand, whether the observed electrical relaxation phenomena actually depend on geometric length scales or rather on other properties such as chemical composition, clay content, clay type or cation exchange capacity. Our poster showcases selected results of a systematic study on texturally and petrophysically very different sandstones.
Iterative numerical 2D-modeling for quantification of material defects by pulsed thermography
(2018)
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects. Typically, analytical 1D models are used to determine the defect depth of flat-bottom holes (FBH), grooves or delamination. However, these models cannot take into account lateral heat flows, or only to a limited extent. They are therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Here, we present an approach for quantitative determination of the geometry for FBH or grooves. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a groove or FBH and its diameter of width. The model takes lateral heat flows into account as well as thermal losses. Figure 1 shows the temperature increase of a pulsed thermography measurement at three different locations on the sample. The numerical model is fitted to the experimental data (red lines) to quantify the groove. The numerical simulation matches the experimental data well.
THz and mid IR spectroscopy of high-molecular PE (HMW) and ultra high-molecular PE (UHMW) reveals modifications of the molecular structure. Characteristic absorption bands are changed if the two materials are exposed by γ-Co60 radiation up to 600 kGy and subsequently stored at an annealing temperature of 398 K until for 729 days.
Nuklear magnetische Resonanz (NMR) etabliert sich zunehmend im Bauingenieurwesen als eine alternative Methode zur zerstörungsfreien Feuchtebestimmung in Baustoffen. Schäden, die durch einen zu hohen Anteil an Flüssigwasser auftreten können, sind Ablösungen, Korrosion, Frostschäden, Induktion von Salzkristallisationen, etc. Aufgrund der Sensitivität für 1H-Protonen, ist NMR eine geeignete Methode zur Feuchtedetektion. Dabei kann laut Theorie zwischen frei, chemisch oder physikalisch gebundenem Wasser differenziert werden, während in der Praxis abhängig von der Messtechnik und Probengröße größtenteils nur das freie Wasser detektierbar ist. Mithilfe der NMR Relaxometrie lassen sich nicht nur Relaxationsabklingkurven ermitteln, sondern auch Relaxationszeitenverteilungen, sowie bei Vollsättigung ggf. eine Porengrößenverteilung ableiten. Darüber hinaus lassen sich erste Annahmen über die Entwicklung der Porensättigung bei Teilsättigung der Probe treffen.
Ziel dieser Arbeit war die Untersuchung der zeitlichen Entwicklung der Porensättigung während des natürlichen Trocknungsprozesses (Teilsättigung) sowie die Ermittlung der Porengrößenverteilung an Beispiel von zementgebundenen Estrichen. Für den Versuch wurden zwei zementgebundene Estrichproben nach abgeschlossener Hydratation wieder aufgesättigt. Während des anschließenden natürlichen Trocknungsprozesses wurden regelmäßig NMR-Messungen durchgeführt sowie die Massenentwicklung observiert. Hauptfokus lag auf der zeitlichen und tiefenabhängigen Entwicklung der Relaxationszeitenverteilungen. Bei fortschreitender Trocknung der Proben konnte eine Verschiebung des Maximums der Relaxationszeitenverteilung zu kleineren Zeiten beobachtet werden. Die Ursache liegt zum einen in dem abnehmenden Anteil an freiem Wasser in größeren Poren und zum anderen in dem verhältnismäßig zunehmenden Signalanteil durch Wasser in kleineren Poren.
Durch den Vergleich mit Quecksilberporosimetrie und Gas-Adsorptions-Ergebnissen, konnte aus den NMR-Daten eine unimodale Porengrößenverteilung mit einer dominanten Porengröße von 0,08 bis 0,1 µm und eine effektive Oberflächenrelaxivität von ca. 10 bis 30 µm/s abgeleitet werden.
The aim of this presentation is to highlight how psychology can be used to prevent human error. It starts with examples of accidents, incidents and events that have happened due to too little attention being dedicated to human factors. It continues arguing that human factors are one of the main factors influencing the reliability of non-destructive testing and gives definitions of the main terms. Furthermore, it presents a method used to identify risks in mechanized NDT to be used for the purposes of the final disposal of spent nuclear fuel and presents a study, in which human-centred design and eye tracking have been used to optimism the inspection procedure. The conclusion is that human factors methods can be used to identify problems during the inspection process and generate mitigation strategies that can be used to decrease human error and enhance safety.
Improvement of effectiveness of in-service inspection in nuclear power plants (IAEA-TECDOC-1853)
(2018)
This publication represents a consensus among experts drawn from the IAEA and global practitioners to compile a set of common or good individual practices for use at nuclear power plants to improve ISI effectiveness. It sets forth a number of strategies and practices for improving the effectiveness of ISI and investigates the role of ISI in maintaining or improving safety at plants and the relationship of ISI improvement to cost. Strategies for improving ISI effectiveness are discussed, with consideration given to the entire framework of ISI, including effective selection of the proper inspection scope, inspection interval and NDE efficiency.
This publication is an update of the publication IAEA-TECDOC-1400, Improvement of In-service Inspection in Nuclear Power Plants, which was published in 2004. It takes into account new techniques and technologies for qualification processes for methodologies, equipment, procedures and personnel as well human factors in NDE inspections.
Thermographic NDE is based on the interaction of thermal waves with inhomogeneities. These inhomogeneities are related to sample geometry or material composition. Although thermography is suitable for a wide range of inhomogeneities and materials, the fundamental limitation is the diffusive nature of thermal waves and the need to measure their effect radiometrically at the sample surface only. The propagation of the thermal waves from the heat source to the inhomogeneity and to the detection surface results in a degradation in the spatial resolution of the technique. A new concerted ansatz based on a spatially structured heating and a joint sparsity of the signal ensemble allows an improved reconstruction of inhomogeneities. As a first step to establish an improved thermographic NDE method, an experimental setup was built based on structured 1D illumination using a flash lamp behind a mechanical aperture. As a follow-up to this approach, we now use direct structured illumination using a 1D laser array. The individual emitter cells are driven by a random binary pattern and additionally shifted by fractions of the cell period. The repeated measurement of these different configurations with simultaneously constant inhomogeneity allows for a reconstruction that makes use of joint sparsity. With analytical-numerical modelling or numerical FEM simulations, we study the influence of the parameters on the result of non-linear reconstruction. For example, the influence of the illumination pattern as a variable heat flux density and Neumann boundary condition for convolution with the constant Green's function can be studied. These studies can be used to derive optimal conditions for a measurement technique.
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for evaluation of material defects. Material defects are often simulated by flat-bottom holes (FBH) or grooves. Typically, analytical 1D models are used to determine the defect depth of FBHs, grooves or delaminations. However, these models cannot take into account lateral heat flows, or only to a limited extent (semi-empirical model). Their applicability is therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Additionally, the surfaces of semi-transparent materials have to be blackened to absorb the radiation energy on the surface of the material. Without surface coatings, these models cannot be used for semi-transparent materials. Available 1D analytical models for determination of sample or layer thicknesses also do not take into account lateral heat flows.
Here, we present an approach for quantitative determination of the geometry of FBHs or grooves in semi-transparent materials by considering lateral heat flow. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a FBH or groove and its diameter or width, respectively. The model considers semi-transparency of the sample within the wavelength range of the excitation source as well as of the IR camera and thermal losses at its surfaces. Heat transport by radiation within the sample is neglected. It supports the use of an arbitrary temporal shape of the heating pulse to properly describe the measurement conditions for different heat sources.
Thermal waves are solutions of the heat diffusion equation for periodic boundary conditions and can be seen analogously to strongly damped waves. Although the underlying differential equation differs from the wave equation, the essential property for analogy between both equations is linearity such that superposition applies. This linearity is maintained even after a linear transformation, such as the Fourier transform from time to frequency domain. It follows that the temporal superposition principle is already used in active thermography, e.g. in pulsed thermography, as a superposition of many individual frequencies. However, the systematic spatial superposition has not yet been fully exploited, mainly due to a lack of suitable energy sources.
As a first step, we are investigating how thermal wave fields of arbitrary space-time structures can be engineered using structured laser illumination. The proof of principle was shown using a laser coupled projector. Unfortunately, the available optical output power was limited due to the thermal stress limit of the device. That is why we are working towards a more sophisticated moving 1D array of high-power diode lasers. We characterized the novel light source and believe that apart from the benefit of spatial and temporal illumination it can combine the temporal regimes of impulse and lock-in thermography.
In a second step, we investigate moving and oscillating line sources with different line shapes. We use a Green’s Function ansatz to analytically model the thermal wave propagation of structured 1D laser illumination in isotropic materials. Furthermore, we show some methods how they can be implemented. With this technique, we were able to accelerate our detection method firstly presented in for vertical narrow defects by factor three. Generally, we believe that this technique opens up similar opportunities than in other NDE methods. High-resolution ultrasound, for example, is also based on the superposition of single emitters and a recent concept suggests an option to deal with the diffusion wave character of the thermal waves.
Im Rahmen der Arbeit soll die Anwendbarkeit des Verfahrens der Nuklear Magnetischen Resonanz (NMR) zur Charakterisierung von Porensystemen und Feuchtetransportmechanismen in Baustoffen untersucht werden. Ein Ziel ist dabei die Bestimmung des Flüssigwasseranteils bei Teilsättigung. Dazu wird die Porensättigung in Abhängigkeit der relativen Luftfeuchte im Porensystem berechnet, um erstmals eine Korrelation zwischen dem NMR-Signal und dem Porensättigungsgrad in einem multimodalen Porengrößensystem bei Teilsättigung vornehmen zu können. Derzeit erfolgen Aufsättigungsversuche an Referenzmaterialien (Sandsteine und Kalziumsilikatplatten). Bereits vorgenommene Untersuchungen bei Vollsättigung an Estrichen haben zunächst eine von der Literatur abweichende Oberflächenrelaxivität ergeben. Dieses Ergebnis legt den Verdacht nahe, dass ein hinreichender Ettringitgehalt, ein Hydratationsprodukt, Einfluss auf die resultierende Oberflächenrelaxivität in Baustoffen haben kann. Somit wird ein weiterer Forschungsschwerpunkt auf den Ettringitgehalt gelegt. Neben ersten Voruntersuchungen mit LIBS und NMR-Spektroskopie, zur Überprüfung der Nachweisbarkeit von Ettringit, sowie ersten Tests zur Steuerung der Ettringitbildung mittels Betonverflüssigern wurde bereits eine Messreihe geplant. Für diese und zukünftige Messungen soll dabei auch erstmals ein neu beschaffter und speziell angefertigter NMR-Tomograph (BAM-Größtgeräteinvestition 2016) Anwendung finden und neue Erkenntnisse ermöglichen.
Optical lock-in thermography is a completely contactless and very sensitive NDE technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive, do not need any work safety measures and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Altogether using lasers considerably increases the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in testing [1, 2]. We report on the mentioned benefits of using such high-power lasers and analyze the range of materials to be tested using lock-in thermography in dependence on the laser irradiance, the modulation frequency, the infrared camera as well as the optical and thermal material parameters. In this context, we also address a number of systematic errors caused by the use of ideal and non-ideal heat sources. For example, the measured phase angle in lock-in thermography depends on the irradiance and the modulation bandwidth of the source. This in turn has a decisive influence on the uncertainty in the quantification of, e.g. layer thicknesses.
Angetrieben durch Digitalisierung und die sogenannte Industrie 4.0 steigt die Erwartungshaltung gegenüber der Nutzung von Sensorik. Die Unsicherheit, Widersprüchlichkeit und Redundanz separat verarbeiteter einzelner Quellen soll durch die synergetische Zusammenführung heterogener Datensätze überwunden werden. Dabei steht der zunehmenden Aufgabenkomplexität eine ebenso zunehmende Verfügbarkeit an Sensoren, Daten und Rechenleistung gegenüber.
Der Begriff Datenfusion fasst Ansätze zusammen, die Daten zu abstrakteren, aber besser verständlichen Informationen verarbeiten. Die Fusion ist Kernbestandteil effektiver Assistenzsysteme und beweist in vielzähligen Aufgaben - von militärischen Anwendungen über Flug- und Fahrassistenzsysteme, bis in den Heimbereich – ihr großes Potenzial. Durch die wachsende Automatisierung bei der Messdatenerfassung wird Datenfusion auch in der industriellen Qualitätsprüfung und –sicherung zunehmend attraktiver.
Der Vortrag gibt einen Überblick über den breiten Themenkomplex und widmet sich dabei speziell der Fragen, welche Informationen in multivariaten Datensätzen stecken und wie sie extrahiert werden können. Abschließend wird ein Beispiel für die erfolgreiche Anwendung zur zerstörungsfreien Prüfung von Betonbauteilen vorgestellt. Der systematische Vergleich von Algorithmen, die Charakteristika des Labordatensatzes in unterschiedlicher Weise adressieren erlaubt überraschende Schlussfolgerungen.
Impact damages and delaminations in fibre-reinforced composites (FRC) might not be visible at the surface, but could have an influence on the resistance and on the long-term behaviour of the component. Therefore, and especially for safety relevant structures, non-destructive methods are required for the assessment of such damages.
Active thermography methods are suitable to characterize damages after loading using different kind of excitation techniques and various configurations of infrared (IR) camera and heating sources. Here, flash lamps, impulse excitation with infrared radiator and lock-in technique with halogen lamps or widened laser beams are suited. In addition, non-optical sources like sonotrodes (requiring direct contact to the structure) or induction generators (only suited for carbon fibre reinforced polymer (CFRP) structures) could be applied as well. For the investigation of the evolution of the damage during the impact, passive thermography can be applied in-situ. Elastic and plastic deformations alter the temperature of the structure and thus the temperature on the surface.
In this contribution, at first the general principles of quantitative defect characterisation in FRC using active thermography with flash, impulse and lock-in excitation are described. Optical and thermal properties of the FRC material and its anisotropy are considered. Results of phase differences obtained at flat bottom holes with flash and lock-in thermography are compared for qualifying both methods for quantitative defect characterization. Secondly, the damage evolution of CFRP and GFRP structures under impact load and static tensile loading is described. The spatial and temporal evolution of the surface temperature enables us to distinguish matrix cracks or fibre-matrix separation from delaminations between the layers. Afterwards, all results for loading defects, obtained by passive and active thermography, are compared with each other. Fig. 1 and 2 show the difference of passive and flash thermography obtained at impact and tensile loaded CFRP plates, respectively. As one purpose of these investigations is the development of standards within national (DIN) and European (CEN) standardisation bodies, new draft and final standards are presented and further needs are discussed at the end of the presentation.
The CLEAN ENERGY Flagship is an initiative designed to utilize recent game changing developments in digital, materials and manufacturing technologies to catalyze a radical paradigm shift towards clean, reliable, efficient and cost-optimal energy.
Unifying and drastically accelerating radically new energy material design, processing and integration across the entire value chain addressing energy production, conversion, storage and systems.
CLEAN ENERGY participants are all distinguished research organisations that each benefit from their own industry networks and contacts with regions and state-level activities and have a long history of collaborating with each other (for 10 years now under the umbrella of EERA) within a European collaborative framework.
Through EERA, CLEAN ENERGY aims to become a crucial partner in the SET-Plan, supporting long-lasting approaches through its established networks and internal collaborations.
Lock-in- and flash thermography are standard methods in active thermography. They are widely used in industrial inspection tasks e.g. for the detection of delaminations, cracks or pores. The requirements for the light sources of these two methods are substantially different. While lock-in thermography requires sources that can be easily and above all fast modulated, the use of flash thermography requires sources that release a very high optical energy in the very short time.
By introducing high-power vertical cavity surface emitting lasers (VCSELs) arrays to the field of thermography a source is now available that covers these two areas. VCSEL arrays combine the fast temporal behavior of a diode laser with the high optical irradiance and the wide illumination range of flash lamps or LEDs and can thus potentially replace all conventional light sources of thermography.
However, the main advantage of this laser technology lies in the independent control of individual array areas. It is therefore possible to heat not only in terms of time, but also in terms of space. This new degree of freedom allows the development of new NDT methods. We demonstrate this approach using a test problem that can only be solved to a limited extent in active thermography, namely the detection of very thin, hidden defects in metallic materials that are aligned vertically to the surface. For this purpose, we generate destructively interfering thermal wave fields, which make it possible to detect defects within the range of the thermal wave field high sensitivity. This is done without pre-treatment of the surface and without using a reference area to depths beyond the usual thermographic rule of thumb.
Die nicht ionisierende elektromagnetische Strahlung im Bereich von Terahertz-Frequenzen ermöglicht berührungslose und zerstörungsfreie Mess- und Prüftechnik in zahlreichen Bereichen. Nach ersten Anwendungen in der Astronomie und der Atmosphärenforschung wurden in letzter Zeit Anwendungsfelder in der Sicherheitstechnik, der Medizintechnik, der Nachrichtentechnik und der zerstörungsfreien Prozess- und Qualitätskontrolle erschlossen. Dielektrische Materialien wie Kunststoffe und Keramiken können von Terahertz-Wellen durchdrungen werden. Das ermöglicht Untersuchungen des Objektinneren ohne spezielle Schutzmaßnahmen, wie sie z.B. beim Röntgen notwendig sind. Die Richtlinie erleichtert die Verständigung zwischen Nutzern, Herstellern und dem Vertrieb von Terahertz-Systemen. In der Richtlinie werden bekannte Einsatzgebiete sowie die eingesetzten Verfahren und Funktionsprinzipien aufgeführt, um den Leser bei der Auswahlentscheidung zu unterstützen. Nach einer kurzen Einführung in die physikalischen Grundlagen und Hinweisen zur elektromagnetischen Verträglichkeit, zum Strahlenschutz und zur regulierten Frequenzvergabe werden die verschiedenen Geräteklassen von Terahertz-Systemen ausführlich vorgestellt. Die Richtlinie gibt Hinweise zur messtechnischen Charakterisierung von Terahertz-Wellen. Einsatzgebiete von Terahertz-Systemen, wie die zerstörungsfreie Prüfung, die Dicken- und Abstandsmessung, die Tomografie und die chemische Analytik, werden mit ihren spezifischen Eigenschaften im Detail beschrieben. Umfangreiche Literaturverweise vereinfachen eine vertiefte Beschäftigung mit den Themen der Richtlinie. Eine tabellarische Übersicht mit einer Zusammenfassung, welche Terahertz-Systeme für welche Anwendungsfelder eingesetzt werden können, vervollständigt die Richtlinie.
Feuchte, insbesondere in Form von Flüssigwasser, stellt in Baustoffen ein hohes Schadenspotential dar. Um mit zerstörungsfreier Prüfung mögliche Risikostellen zu lokalisieren und Präventionsmaßnahmen zu ergreifen, sind Kenntnisse über das Porengefüge und Feuchtetransportmechanismen im Baustoff erforderlich. Eine wesentliche Problematik besteht derzeit in der Erfassung und Quantifizierung von Feuchteverteilungen bei Teilsättigung.
Wir verfolgen derzeit einen Ansatz, mittels Nuklear Magnetischer Resonanz (NMR) in Korrelation mit relativen Luftfeuchtmessungen den Flüssigwasseranteil bei Teilsättigung zu ermitteln. Mit Protonen-NMR lassen sich Relaxationszeiten von Wasserstoffprotonen in Abhängigkeit von ihrer Bindungsart und ihrer Umgebung - z. B. Porenstruktur und -größe - erfassen. Allerdings lässt sich bei Materialien mit sehr breiten Porengrößenverteilungen nicht klar differenzieren, ob kurze Relaxationszeiten durch größere teilgesättigte oder kleinere vollgesättigte Poren verursacht werden. Für die Korrelation mit der relativen Luftfeuchte im Baustoff erfolgt zunächst eine künstliche Regulierung im Klimaschrank. Durch einen neuentwickelten Ansatz von Hillerborg lassen sich dann bei jeder Luftfeuchte die adsorbierten Wasserschichtdicken und der Porensättigungsgrad für die vorhandenen Porengrößen berechnen. Mithilfe des berechneten Porensättigungsgrades lässt sich eine genauere Analyse der zeitlichen Entwicklung von Relaxationszeitenverteilungen (insbesondere bei Trocknungs- und Aufsättigungsprozessen) vornehmen. Somit sollen erstmals Aussagen zu kürzeren Relaxationszeiten bei teilgesättigten Porensystemen, die beispielsweise auch eine multimodale Porengrößenverteilung aufweisen, getroffen werden können.
In dieser Arbeit wird die Kombination aus NMR und der relativen Luftfeuchte an sehr porösen Dämmplatten aus Kalziumsilikat, die zur Wärmedämmung sowie der Entgegenwirkung von Schimmelbildung eingesetzt werden, angewendet. Untersucht werden 28 Proben à 6 Gruppen, die von unterschiedlichen Herstellern stammen bzw. unterschiedlich hergestellt wurden.
Leitungswasserschäden nahmen im Jahr 2016 mit rund 2,6 Milliarden Euro den größten Posten bei Gebäudeversicherungen ein. Die Bestimmung und Lokalisierung des Schadensausmaßes ist dabei ein erster wichtiger Schritt, um die erforderlichen Sanierungsarbeiten abschätzen und effizient vornehmen zu können. Hierfür sind Radar und Neutronensonden bereits etablierte Verfahren. Für verlässliche Aussagen zum quantitativen Feuchtegehalt eines Baustoffes werden jedoch zerstörende Sondierungsbohrungen zur Kalibrierung der aufgenommenen Daten benötigt. Dieser hohe zeitliche und finanzielle Aufwand soll zukünftig durch den parallelen Einsatz der genannten Messverfahren verhindert werden.
In der durchgeführten Studie wurden Estrichprobekörper auf Zement- und Anhydritbasis mit variablen Dicken und Festigkeiten hergestellt und deren Austrocknung mit Radar und Neutronensonde über einen Zeitraum von 90 Tagen beobachtet. Als Referenzverfahren zur Ermittlung des Feuchteverlaufs dienten die gravimetrische Darr- und chemische Calcium-Carbid-Methode, welche an kleineren Schwesterproben der gleichen Charge angewendet wurden. Kontinuierliche Wägungen der größeren Probekörper gaben hierbei Aufschluss über den durch Austrocknung schwindende Wasseranteil.
Aus dem aufgenommen Radardatensatz konnten anschließend markante Signalmerkmale im Zeit- und Frequenzbereich extrahiert und deren Zusammenhang zum Feuchtegehalt der Estrichtypen untersucht werden. Hierbei wurden gängige Methoden aus der Literatur zur Feuchtemessung mit Radar angewandt, wobei die Kombination dieser und das Hinzuziehen der Neutronensonde mittels Datenfusion zu einem höheren Informationsgehalt beiträgt. Somit kann eine zerstörungsfreie Quantifizierung des Feuchteschadens an schwimmenden Fußbodenaufbauten vorgenommen werden
Leitungswasserschäden nahmen im Jahr 2016 mit rund 2,6 Milliarden Euro den größten Posten bei Gebäudeversicherungen ein. Die Bestimmung und Lokalisierung des Schadensausmaßes ist dabei ein erster wichtiger Schritt, um die erforderlichen Sanierungsarbeiten abschätzen und effizient vornehmen zu können. Hierfür sind Radar und Neutronensonden bereits etablierte Verfahren. Für verlässliche Aussagen zum quantitativen Feuchtegehalt eines Baustoffes werden jedoch zerstörende Sondierungsbohrungen zur Kalibrierung der aufgenommenen Daten benötigt. Dieser hohe zeitliche und finanzielle Aufwand soll zukünftig durch den parallelen Einsatz der genannten Messverfahren verhindert werden. In der durchgeführten Studie wurden Estrichprobekörper auf Zement- und Anhydritbasis mit variablen Dicken und Festigkeiten hergestellt und deren Austrocknung mit Radar und Neutronensonde über einen Zeitraum von 90 Tagen beobachtet. Als Referenzverfahren zur Ermittlung des Feuchteverlaufs dienten die gravimetrische Darr- und chemische Calcium-Carbid-Methode, welche an kleineren Schwesterproben der gleichen Charge angewendet wurden. Kontinuierliche Wägungen der größeren Probekörper gaben hierbei Aufschluss über den durch Austrocknung schwindende Wasseranteil. Aus dem aufgenommen Radardatensatz konnten anschließend markante Signalmerkmale im Zeit- und Frequenzbereich extrahiert und deren Zusammenhang zum Feuchtegehalt der Estrichtypen untersucht werden. Hierbei wurden gängige Methoden aus der Literatur zur Feuchtemessung mit Radar angewandt, wobei die Kombination dieser und das Hinzuziehen der Neutronensonde mittels Datenfusion zu einem höheren Informationsgehalt beiträgt. Somit kann eine zerstörungsfreie Quantifizierung des Feuchteschadens an schwimmenden Fußbodenaufbauten vorgenommen werden
Iterative numerical 2D-modelling for quantification of material defects by pulsed thermography
(2019)
This paper presents a method to quantify the geometry of defects such as flat bottom holes (FBH) and notches in opaque materials by a pulse thermography (PT) experiment and a numerical model. The aim was to precisely describe PT experiments in reflection configuration with a simple and fast numerical model in order to use this model and a fit algorithm to quantify defects within the material. The algorithm minimizes the difference between the time sequence of a line shaped region of interest (ROI) on the surface (above the defect) from the PT experiment and the numerical data. Therefore, the experimental data can be reconstructed with the numerical model. In this way, the defect depth of a notch or FBH and its width or diameter was determined simultaneously. A laser was used for heating which was widened to a top hat spatial profile to ensure homogeneous illumination (rectangular impulse profile in time). The numerical simulation considers heating conditions and takes thermal losses due to convection and radiation into account. We quantified the geometry of FBH and notches in steel and polyvinyl chloride plasticized (PVC-U) materials with an accuracy of < 5 %.
19th and 20th centuries glass paint layers consist of a colour body and a colourless lead silicate flux, in which borax or boric acid was added as further component to improve the paint ability and to reduce the firing temperature for multiple layers of paint. Model glasses were used in laboratory tests to investigate the stability of glass paints with additions of boron oxide. To determine boron in paint layers, a LIBS-system with pulsed NdYAG-laser was used.
Photothermal radiometry with an infrared camera allows the contactless temperature measurement of multiple surface pixels simultaneously. A short light pulse heats the sample. The heat propagates through the sample by diffusion and the corresponding temperature evolution is measured at the sample’s surface by an infrared camera. The main drawback in radiometric imaging is the loss of the spatial resolution with increasing depth due to heat diffusion, which results in blurred images for deeper lying structures. We circumvent this information loss due to the diffusion process by using blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The structured illumination is realized by parallel laser lines from a vertical-cavity surface-emitting laser (VCSEL) array controlled by a random binary pattern generator. By using 150 different patterns of structured illumination and our iterative joint sparsity algorithm, it was possible to resolve 1 mm thick lines at a distance down to 0.5 mm, which results in a resolution enhancement of approximately a factor of four compared to the resolution of 5.9 mm for homogenous illuminated thermographic reconstruction.
Die zeitaufgelöste THz-Spektroskopie (THz-TDS) operiert mit elektromagnetischen Impulsen, die ein Amplitudenspektrum im unteren THz-Bereich aufweisen. Die THz-TDS ist in der Lage, dielektrische Volumina zerstörungs- und kontaktfreie zu durchstrahlen. Um eine 3D-THz Bildung zu ermöglichen, wurde für die THz-TDS ein rechnergestütztes Mess- und Rekonstruktionsverfahren (THz-TDSAFT) entwickelt, mit dem es gelingt, unter Verwendung der im Zeitbereich registrierten THz-TDS-Daten das Volumeninnere in Form eines dreidimensionalen Tomogramms zu rekonstruieren. Die THz-TD-SAFT basiert auf die für die Ultraschalltechnik entwickelte Synthetische Apertur Fokussierung (SAFT) bzw. des heuristisch begründeten Algorithmus des Synthetischen Apertur Radars (SAR). Anhand von Beispielen wird die Möglichkeiten der THz-TD-SAFT demonstriert und nachgewiesen, dass mit dem Rekonstruktionsansatz die künstlich eingebauten Fehlstellen bezüglich der Position und Größe geometrisch richtig im Tomogramm abgebildet werden können.
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects, to determine thermal material parameters, and the thickness of test specimens through calibration or mathematical models. However, the application to semitransparent materials is quite new and demanding, especially for semitransparent materials like epoxy, polyamide 12, or glass fiber reinforced polymers with epoxy or polyamide matrix.
In order to describe the temporal temperature evolution in such materials, which are recorded with an infrared camera during pulse thermography experiments, much more influences have to be considered, compared to opaque materials:
- The wavelength of the excitation source and the spectral range of the infrared camera
- The angles between the specimen, the excitation source and the infrared camera
- The area behind the specimen
- The roughness of the material surface
- The scattering mechanism within the material
Here, we will consider all these influences and describe how they can be treated mathematically in analytical or numerical models (using COMSOL Multiphysics software). These models describe the temperature development during the pulse thermography experiment in reflection and transmission configuration. By fitting the results of the mathematical models to experimental data it is possible to determine the thickness or the optical and thermal properties of the specimen.
Der Beitrag beschreibt den Aufbau und die Entwicklung einer Heißluftquelle als Wärmequelle für die aktive Thermografie. Als Ausgangspunkt wird zunächst die Quellenlage betrachtet. In der Literatur über Thermografie spielt Heißluft als Wärmequelle nur in weniger als 0,1% eine Rolle, die Ursache dafür ist nicht bekannt. Es wird vermutet, dass dieser Erwärmungsmethode unterstellt wird, sie hätte Nachteile bezüglich Homogenität der Erwärmung sowie Leistungseintrag. In einer der raren Publikationen über einen Verfahrensvergleich schnitt die Heißluft-Thermografie jedoch nicht schlechter als die Vergleichsverfahren mit optischer Anregung ab, bei gleichzeitig deutlichem Zeitgewinn und geringerem technischen Aufwand.
Danach wird der fertige Versuchsaufbau mit seinen wesentlichen Komponenten dargestellt. Der Einfluss der Geometrie der Luftaustrittsdüse auf die erreichbare Wärmeverteilung an einem flachen Blech wurde an mehreren Düsen untersucht. Hierbei erwies sich eine langgestreckte Umlenkdüse mit einer Strahlumlenkung von etwa 20° als optimal zur Erzeugung einer möglichst homogenen Erwärmung.
Ein weiterer zu optimierender Parameter war die erreichbare Schaltdynamik des Heißgasstromes. Beim schnellen Schalten großer Volumenströme treten Druckstöße mit entsprechenden Temperaturänderungen auf. Hinzu kommt, dass der verwendete MFC (mass flow controller) bei großen Volumenströmen zum Einschwingen bei Schaltprozessen neigt.
Daher enthält der Aufbau einen offenen Bypass zur Stabilisierung des Volumenstroms. Mit dem so realisierten Messplatz wurde die Reproduzierbarkeit der erzielten Erwärmung durch mehrfache Wiederholungsmessungen über einen längeren Zeitraum untersucht. Hierzu wurde ein auch zu Validierungszwecken genutzter PVC-Block mit 13 mm Dicke jeweils für 60 s erwärmt und die Oberflächentemperatur des PVC-Blocks mit einer IR-Kamera aufgezeichnet. Bei jeweiligem Neuaufbau ohne Justierhilfe ergab sich eine Reproduzierbarkeit von etwa 22% bei 5 Versuchen. Unter Nutzung einer Justierhilfe (Schablone für Abstand in der Kamerasoftware) ließ sich die Reproduzierbarkeit auf 5% bei 7 Versuchen reduzieren.
Ein weiterer zu klärender Punkt war der erzielbare Wärmeeintrag im Vergleich zu einer Anregung mit Blitzlampen. Hierzu wurde eine Messung mit 60 s Heißluftheizung direkt mit einer Evaluierungsmessung mit Blitzlampen am gleichen PVC-Probekörper mit 4 FBB an der Rückseite verglichen. Die Inhomogenität der Erwärmung wurde durch eine Phasenauswertung unterdrückt. Die Phasenauswertung gestattete den Nachweis aller 4 FBB, wobei das Signal zu Rausch-Verhältnis bei der Heißlufterwärmung deutlich besser war. Der direkte Vergleich der Temperaturkurven zeigt, dass bei 60 s Heizlufterwärmung ca. 4,5 mal mehr Energie als bei der Blitzanregung vom Probekörper absorbiert wurde. Hieraus lässt sich die eingekoppelte Heizleistung mit 100 mW/cm² abschätzen. Das entspricht in etwa dem Niveau, wie es auch mit bewegten Halogenstrahlern, bewegten IR-Strahlern oder der Sonne erreicht wird.
Diese Ergebnisse belegen, dass eventuell vorhandene Vorbehalte gegenüber einer Heißluft als Wärmequelle für die aktive Thermografie zumindest für thermisch langsame Materialien wie Kunststoffe oder mineralische Baustoffe unbegründet sind. Die Einsatzgrenzen bei der Untersuchung thermisch schnellerer Materialien wie Metalle steht noch aus, hier ist mit Abstrichen zu rechnen. Auf der anderen Seite lässt eine mögliche Düsenoptimierung noch deutliche Verbesserungen erwarten.
Das vorgestellte Projekt beschäftigt sich mit den optischen, thermophysikalischen und mechanischen Materialeigenschaften von additiv gefertigten Kunststoffteilen und deren Alterung. Dazu wurden mittels Fused Layer Modeling (FLM) Probekörper aus ABS hergestellt, die anschließend für drei Monate einer künstlichen Bewitterung unterzogen wurden. Die dabei erzeugte definierte Alterung wurde nach drei Zeitabschnitten jeweils mit zerstörungsfreien Methoden charakterisiert. Dabei wurde neben den spektroskopischen Standardmethoden auch die aktive Thermografie eingesetzt. Die Ergebnisse zeigen, dass sich mittels der Thermografie sowohl chemische Veränderungen als auch mechanische Schädigungen (Fehlstellen) darstellen lassen. Die Bewitterung beeinflusst die Teiltransparenz der Proben zumindest im sichtbaren Spektralbereich, was bei der Charakterisierung der Fehlstellen, die mittels optisch angeregter aktiver Thermografie detektiert wurden, berücksichtigt werden muss.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or hardly accessible areas. A challenging task, however, is the generation of threedimensional distribution maps from these gas measurements.
Suitable reconstruction algorithms can be adapted, for instance, from the field of computed tomography (CT), but both their performance and strategies for selecting optimal measuring poses must be evaluated. For this purpose simulations are used, since, in contrast to field tests, they allow repeatable conditions. Although several simulation tools exist, they lack realistic models of remote gas sensors. Recently, we introduced a model for a Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor taking into account the conical shape of its laser beam. However, the novel model has not yet been validated with experiments. In this paper, we compare our model with a real sensor device and show that the assumptions made hold.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or hardly accessible areas. A challenging task, however, is the generation of threedimensional distribution maps from these gas measurements.
Suitable reconstruction algorithms can be adapted, for instance, from the field of computed tomography (CT), but both their performance and strategies for selecting optimal measuring poses must be evaluated. For this purpose simulations are used, since, in contrast to field tests, they allow repeatable conditions. Although several simulation tools exist, they lack realistic models of remote gas sensors. Recently, we introduced a model for a Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor taking into account the conical shape of its laser beam. However, the novel model has not yet been validated with experiments. In this paper, we compare our model with a real sensor device and show that the assumptions made hold.
Diese Arbeit beschäftigt sich mit den Eigenschaften der photonenzählenden und spektralauflösenden Detektortechnik und möglichen Anwendungsgebieten in der zerstörungsfreien Prüfung. Dabei wurden konventionelle und photonenzählende Detektortechniken hinsichtlich der Bildqualität und Anwendbarkeit bei unterschiedlichen Prüfaufgaben verglichen und untersucht, inwiefern sich die Energieschwellwertsetzung auf die erreichbare Bildqualität und eine Materialdiskriminierbarkeit bei verschiedenen radiographischen Verfahren auswirkt.
Anhand von Anwendungsbeispielen wurden diese Eigenschaften und deren Auswirkung auf das Messergebnis analysiert. Neben der Radiographie wurden auch dreidimensionale Verfahren wie CT und Laminographie berücksichtigt.
Als eine der wichtigsten Eigenschaften der photonenzählenden Detektortechnik wurden zunächst die Energieauflösung des photonenzählenden Detektors und die Homogenität der Energieantwort über größere Detektorbereiche bestimmt. Dabei stellte sich heraus, dass die Energieauflösung eines abgegrenzten Detektorbereichs ca. 32 % bei 60 keV beträgt und die Streuung in der Energieantwort der einzelnen Detektorbereiche ca. 12 % ausmacht, woraus sich eine Gesamtunsicherheit in der spektralen Detektorantwort von ca. 44 % ergibt. Die geringe Energieauflösung und das stark heterogene Verhalten der Detektorbereiche ergeben sich vor allem aus der Detektorelektronik, welche nur eine globale Energieschwellwertsetzung zulässt.
Trotz dieser Einschränkungen konnte demonstriert werden, dass auch konventionelle radiographische Verfahren, wie Radiographie oder CT, vom Einsatz der photonenzählenden Technik profitieren. So ist es mit dieser Technik möglich, bei sehr geringen Dosisleistungen (z.B. aufgrund der Durchstrahlung großer Wandstärken von dichten Materialien) noch sehr gute Bildqualitäten zu erreichen. Die hohe Dynamik und Kontrastempfindlichkeit dieser Technik begünstigen die Inspektion von Leichtbauwerkstoffen wie Faserverbunde, was anhand von Vergleichen mit herkömmlicher Detektortechnik und anderen ZfP-Verfahren gezeigt werden konnte. Daneben konnte durch den Einsatz der Energieschwellwertsetzung der Einfluss von nicht bildzeichnender Streustrahlung im Röntgenbild um bis zu 20 % reduziert werden. Die Auswirkungen von Aufhärtungseffekten in der CT konnten sogar um bis zu Faktor 1 000 (in der mittleren quadratischen Abweichung), im Vergleich zu herkömmlicher Detektortechnik, reduziert werden.
Der Einsatz von photonenzählender Detektortechnik mit Röntgenblitzröhren ist hingegen nicht sinnvoll, da aufgrund der hohen Photonendichte pro Puls und einer endlichen Totzeit des Detektors in der Größenordnung der Pulsbreite eines Blitzes nur ein geringes Signal detektiert werden kann.
Im Hinblick auf eine Materialdiskriminierbarkeit konnte demonstriert werden, dass im Fall einer Radiographie anhand der Energieschwellwertsetzung im Detektor eine materialstärkenunabhängige Diskriminierung zwischen zwei Materialien (hier: Al und Fe) erzielt werden kann. Unter Einsatz mehrerer Energiefenster und eines Verfahrens der explorativen und multivariaten Datenanalyse konnte eine materialaufgelöste CT eines Multi-Material-Phantoms erreicht werden, wobei die Schwächungskoeffizienten der enthaltenen Materialien im relevanten Energieberiech teilweise sehr dicht beieinander lagen.
Neben Radiographie und CT wurde auch die Möglichkeit einer materialaufgelösten Laminographie am Beispiel eines glasfaserverstärkten Rotorblatts untersucht. Anhand der Energieschwellwertsetzung war nicht nur eine eindeutige Trennung der Glasfasern von der Epoxidharzmatrix möglich, sondern auch eine signifikante Reduzierung der durch die Laminographie entstandenen Artefakte. Der damit verbundene Gewinn an Information führt zu einer verbesserten Aussagefähigkeit des Untersuchungsergebnisses, was letztendlich eine gesteigerte Betriebssicherheit zur Folge hat.
This international symposium is devoted to promote a broad exchange of information on technologies, applications and quality assurance in the area of digital industrial radiology and computed tomography. The meeting provides a unique opportunity for users, scientists, equipment suppliers and all who are interested to discuss the present and future possibilities for industrial applications of the following topics:
- Xray detectors and sources
- Image processing algorithms
- Quantitative imaging
- Defect detection & localisation
- Feature extraction
- Dimensional control
- CT, multi-angle - radiography
- Laminography & Tomosynthesis
- Modelling
- Film replacement
- Phase contrast
- Multi-energies and photon counting
- Other radiation techniques (e.g. - neutrons)
- Multi-techniques fusion
- Standardisation
- Qualification & system reliability
- Inspection for Additive Manufacturing
- Scattering
Metallische Mikropartikel in der Größenfraktion von ca. 10 – 100 Mikrometer bilden das Grundmaterial für den additiven Aufbau komplexer Strukturen durch lokales Aufschmelzen mit einem Laserstrahl. Entscheidend für dieses Verfahren ist die Kenntnis der Größen-, Form- und Defektverteilungen von Partikelfraktionen, da sie direkten Einfluss auf die Fließfähigkeit des Pulvers während des lagenweisen Auftragens, als auch auf die finale innere Porosität des Bauteils haben. Im Pulver vorhandene Poren verlassen in der Regel das Schmelzbad vor dem Erstarren nicht wieder, da deren Konvektionszeiten größer sind als die Zeit, während der das lokale Schmelzbad besteht, so dass einmal durch die Ausgangspartikel eingebrachte Poren in der Regel auch im fertigen Bauteil verbleiben. Eine strenge Qualitätskontrolle des Ausgangspulvers ist also Voraussetzung, um hochwertige Bauteile mit geringer Restporosität zu erhalten. Der Vorteil der Röntgentomographie ist dabei, dass mit nur sehr geringem Präparationsaufwand innenliegende Poren bis zu einem Durchmesser von wenigen Mikrometern detektiert werden können. Dies ist mit konkurrierenden Verfahren (Licht- / Elektronenmikroskopie, Laserbeugung) so nicht möglich. Zusammenfassend werden wir zeigen, dass die zerstörungsfreie Bildgebung mit der Röntgen-Mikrotomographie für die Qualitätskontrolle in der additiven Fertigung ein leistungsfähiges Werkzeug ist. Wir erörtern die Grenzen der Methode durch eine numerische Studie mithilfe des Simulationsprogramms aRTist. Dabei werden verschiedene Partikelgrößen dahingehend untersucht, welche Poren mit mikroradiographischen Verfahren detektierbar sind. Dazu wird ein Modell für eine dreilagige dichteste Kugelpackung entwickelt, so dass auch Überlagerungen von Anzeigen untersucht werden können. Im Ergebnis werden verschiedene Partikel- und Porengrößenkombinationen untersucht und die entsprechenden Detektionsgrenzen bestimmt.
Neben der klassischen Durchstrahlung wird die bildgebende Röntgen-rückstreuung bisher nur sehr begrenzt eingesetzt. Vor über 20 Jahren hatte Philips mit „COMSCAN“ eine erste industrielle Anwendung in der Luftfahrt gefunden, die sogar eine Tiefenauflösung besaß. Die Firma AS&E in Boston bietet Röntgenrückstreu-Anlagen für den Sicherheitsbereich an. In diesen wird mit einem hochkollimierten Nadelstrahl aus einem rotierenden Blendenrad ein Objekt einseitig abgetastet. Zur Detektion der gestreuten Strahlung aus dem Objekt werden großflächige Detektoren direkt neben dem rotierenden Nadelstrahlkollimator eingesetzt. Ein solcher Prototyp wird an der BAM für den Einsatz in der zerstörungsfreien Prüfung untersucht und optimiert. Als neues industrielles Einsatzgebiet wird dabei die in situ Überwachung in der additiven Fertigung avisiert. Hier ist die Zugänglichkeit zum entstehenden Werkstück in den 3D-Druckanlagen stark eingeschränkt, was den Einsatz einer zweiseitigen Durchstrahlung oder der Computer-Tomographie, bei der das Objekt rotiert wird, verhindert. Auch sind die in der additiven Fertigung eingesetzten Werkstoffe (Polymere, Keramik, Leichtmetalle wie Al oder Ti) für die Rückstreuung besser geeignet als Metalle höherer Dichte, da das Streusignal mit der Ordnungszahl und der Materialdichte abnimmt. Allerdings sind die Anforderungen an räumliche Auflösung und Kontrastempfindlichkeit in der zerstörungsfreien Prüfung additiv gefertigter Bauteil deutlich höher als im Sicherheitsbereich, da hier Bauteilfehler mit typischen Dimensionen kleiner als 1 mm sicher detektiert werden müssen. Die Untersuchung dieser Grenzen des derzeitigen Standes der Röntgenrückstreutechnik mit Nadelstrahl ist ein Teilbereich des mehrjährigen BAM-Themenfeldprojektes „ProMoAM“. Im Vortrag werden die ersten Ergebnisse der Optimierung sowie die gefundenen Anwendungsgrenzen an Beispielen erläutert.
Neues aus der BAM 2019
(2019)
X-ray back scatter imaging is rarely applied compared to classical X-ray projection imaging. More than 20 years ago the company Philips developed “COMSCAN”, a first application case for aircraft industry, which allowed even a depth resolution using back scatter imaging. The company AS&E in Boston offers back scatter imaging solutions for the security market. The principle is to scan the object with a highly collimated X-ray needle beam from one side only and to detect the backscattered radiation by a large area detector side by side with the collimation wheel. A new prototype is investigated at BAM for application and optimization in non-destructive testing. As modern industrial application field in-situ inspection in additive manufacturing is targeted. The accessibility of the printed part during the production process is very limited. This prevent the application of a two sided X-ray inspection or Computed Tomography, were an rotation of the object is required to acquire projections from 360 degrees. An important advantage for the X-ray back scatter technique are also the materials used in additive manufacturing (polymers, ceramics, light metals like Aluminum or Titanium). These materials with lower density and lower Z values give better scatter signals than metals with higher densities and Z values. The back scatter intensity decreases with increasing density and Z value of the material. But the requirements on spatial resolution and contrast sensitivity are more stringent for non-destructive testing of additive manufactured parts compared to the security area. In NDT sizes of indications smaller than 1 mm have to be detected clearly. The investigation of these limits on a state-of-the-art prototype for X-ray back scattering using rotating collimated X-ray needle beams is a part of the BAM project “ProMoAM”. The contribution shows first results of the optimization for NDT and the achieved application limits for several example cases.
X-Ray Computed Tomography (CT) is applied in industry for flaw detection, flaw evaluation and dimensional measurement. This requires the correct CT system settings for sufficient visibility and detectability of flaws and structure elements. The visibility of indications for human observers on a monitor depends on the square root of the reconstructed flaw area (here pores with diameter < ½ inch) in the cross sectional 2D images, the Contrast to Noise Ratio (CNR) and the Modulation Transfer Function (MTF). This applies also to 2D-projections, meaning also to “normal” digital radiographs. The ASTM guide E 1441 describes three essential functions for prediction of the visibility of small circular indications in slice images of a 3D reconstruction or a 2D reconstruction. This is the Contrast Discrimination Function (CDF), the MTF (see also the revision of ASTM E 1695), and the Contrast Detail Dose (CDD) function. The prediction of the visibility of circular indications in reconstructed slice images can be determined from the Contrast Detail Dose function, which is the combination of CDF and MTF and a physiological factor c. The measurement procedures and formulas for the prediction of the detail visibility by CDD will be corrected, tested and verified by modelling and in a Round Robin Test with modern commercial 3D CT systems of different manufacturers. Conclusions will be reported and recommendations will be given for the correct psychological factor c and the consideration of the influence of artefacts, as e.g. cupping and scatter.
Der Ersatz von Röntgenfilmen durch digitale Detektoren in der Zerstörungsfreien Prüfung im Anlagenbau wird seit 2013 durch neue ISO-Normen unterstützt. Nach der Erfolgsgeschichte der digitalen Photographie und der fast voll-ständigen Ablösung der Filmtechnik in der optischen Bilderfassung wird erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollzieht. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Computerra-diographie mit Speicherfolien eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluorosko-pe gibt. Mit Einführung der DIN EN ISO 17636-2 zur Schweißnahtprüfung wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte (Fehlernachweiß-empfindlichkeit) erreicht wird. Ein Überblick zeigt, welche Parameter für den praktischen Einsatz wichtig sind und wie sie ermittelt werden. Praktische Einsatzbeispiele im Anlagenbau werden diskutiert.
Der Ersatz von Röntgenfilmen durch digitale Detektoren in der Zerstörungsfreien Prüfung im Anlagenbau wird seit 2013 durch neue ISO-Normen unterstützt. Nach der Erfolgsgeschichte der digitalen Photographie und der fast vollständigen Ablösung der Filmtechnik in der optischen Bilderfassung wird erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollzieht. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Computerradiographie mit Speicherfolien eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluoroskope gibt. Mit Einführung der DIN EN ISO 17636-2 zur Schweißnahtprüfung wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte (Fehlernachweißempfindlichkeit) erreicht wird. Ein Überblick zeigt, welche Parameter für den praktischen Einsatz wichtig sind und wie sie ermittelt werden. Praktische Einsatzbeispiele im Anlagenbau werden diskutiert.
Die Technologie der hybriden Teilchen (oder Photonen) zählenden Bilddetektoren wurde seit mehr als 2 Jahrzehnten durch Institutionen wie das CERN (MediPix-/ TimePix-Chips) oder das Paul-Scherrer-Institut (Pilatus-/ Eiger-Chips) entwickelt. Die Ursprünge dieser Technologie kommen aus der Hochenergie-Physik mit ihren Beschleuniger-basierten Experimenten, bei denen ein zuverlässiger und rauschfreier Nachweis jedes ionisierten Teilchens gefordert wird. Eine Energieauflösung wird ebenfalls oft verlangr. Das ist auch in der klassischen Radiographie von Nutzen, so wurden diese Detektoren auch dafür optimiert. Neueste Photonen zählenden Detektoren besitzen folgende exzellenten Bildeigenschaften: rauschfreie Photonen-Detektion in einem hohen Dynamikbereich (SNR >2500 erreichbar), hohe räumliche Auflösung (bis zu 10 µm Pixelgröße), Energieschwellen bis zur vollen spektralen Auflösung und eine sehr hohe Geschwindigkeit (bis zu Tausenden Bildern pro Sekunde). Diese hybriden Detektoren können mit hochabsorbierenden Sensorschichten aus CdTe, CZT oder GaAs bestückt werden, um bildgebende Anwendungen mit Gamma- oder harten Röntgenstrahlen zu realisieren, in denen bisher Szintillator basierende Bilddetektoren dominierten (z.B. für NDT, SPECT, PET). Im Beitrag wird der erste wirklich große Photonen zählende Detektor mit CdTe und einer lückenlosen Detektionsfläche, die aus einer theoretisch unbegrenzten Anzahl von MediPix-/ TimePix-Modulen besteht, gezeigt. Die erste kommerzielle Version eines solchen Detektors hat eine Fläche von 7cm x7cm, 1,6 Megapixel und erfüllt die Anforderungen der Prüfklasse „B“ in der industriellen Radiographie. Die Energie auflösenden Fähigkeiten dieses Detektors erlauben eine „Farb-Radiographie“, in der verschiedene Materialien in verschiedene Farben dargestellt werden. Der 2. Teil dieses Beitrags stellt einen voll spektral auflösenden Gamma- und Röntgen-Bilddetektor mit dickem CdTe und 2,4 Megapixel vor, der auf TimePix3-Chips basiert und eine sehr hohe Ortsauflösung von ~10 µm erreicht. Die hohe Zeitauflösung von TimePix3 wird mit großem Nutzen für eine substantielle Verbesserung der erhaltenen Bilder und Spektren zur Unterdrückung interner Fluoreszenzstrahlung sowie Comptonstreuungsanteilen, die die Bildinformation verschmieren, verwendet.
In den letzten zwei Jahren wurden 11 neue Standards/Standardrevisionen zur RT veröffentlicht (ohne Strahlenschutz) und 5 werden dafür gestrichen. Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei Prüfpraxis und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Die Standards zur Schweißnahtprüfung in der Kerntechnik, DIN 25435, wurden ins Englische übertragen und bei ISO TC 85 SC 6 bearbeitet. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der Guide ASTM E 1441 zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wird revidiert. E 2445 zur CR Long Term Stability wird ebenfalls revidiert. Die Revision soll auch in die ISO 16371-1 eingehen. Dazu ist ein Round Robin-Test geplant. Auch die Standards zur Durchstrahlungsprüfung auf Korrosion und Ablagerungen in Rohren mit Röntgen- und Gammastrahlen (EN 16407-1, -2, 2014) wurden revidiert. Diese Revision wurde als DIN EN ISO 20769-1, -2 2018 veröffentlicht und EN 16407 wird zurückgezogen. Die Revision der Standards EN 12543 und EN 12679 zur Messung der Brennfleckgröße und der Strahlergröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Zur radiographischen Gussteilprüfung wurde der Standard EN 12681 revidiert und 2018 veröffentlicht. Er wurde um Zulässigkeitsgrenzen erweitert und die digitale Radiographie wurde in Teil 2 berücksichtigt.