Zinc phosphate, an important pigment in phosphate conversion coatings, forms protective films on rubbing surfaces.
We have simulated the underlying reactions under shear by ball-milling zinc phosphate and monitored the reaction of hopeite (Zn3(PO4)2·4H2O) and the retarded recrystallization of the amorphous reaction product by powder X-ray diffraction (PXRD) and quantitative infrared (IR) spectroscopy. Abrasion of stainless steel was simulated by addition of pure 57Fe. The results provide insight into the chemistry of phosphate conversion coatings or during battery cycling of metal phosphates and give theoretical guidance for the preparation of amorphous phosphates. Thermal analysis revealed that the release of structural water is a key step during the reaction of hopeite under shear to ball-milled amorphous zinc phosphate. The back-reaction and associated recrystallization kinetics of amorphous zinc phosphate show a classical Langmuir behavior. Fe impurities inhibit the recrystallization of ball-milled amorphous zinc phosphate strongly. 57Fe Mössbauer spectroscopy and PXRD revealed that Fe is oxidized to Fe2+ and Fe3+ during ball-milling and incorporated locally at the tetrahedral and octahedral sites of the structure. Ball-milled amorphous zinc phosphate is metastable as γ-Zn3−xFex(PO4)2. EPR studies showed the incorporation of Fe3+ to be coupled with the formation of Zn2+ vacancies. The Fe3+ defect sites bind water because of their higher Pearson hardness (compared to Fe2+ and Zn2+), thereby reducing water mobility and inhibiting further reactions like the recrystallization to hopeite. Our findings reveal the amorphization mechanism of Zn3(PO4)2·4H2O in stainless steel ball mills at the atomic scale and highlight how the reactivity of amorphous products is affected by impurities associated with the processing method.
This paper proposes a novel method to estimate the lateral displacement of high-rise structures under wind loads. The coefficient β(x) is firstly derived, reflecting the relation between the structural lateral dynamic displacement and the inclination angle at the height x of a structure. If the angle is small, it is the ratio between the structural fundamental mode shape and its first-order derivative without influence of external loads. Several dynamic experiments of structures are performed based on a laser remote sensing vibrometer and an inclinometer, which shows that the fundamental mode is dominated in the structural displacement response under different types of excitations. Once the coefficient β(x) is curve-fitted by measuring both the structural lateral dynamic displacement and the inclination angle synchronously, the real-time structural lateral displacement under operational conditions is estimated by multiplying the coefficient β(x) with the inclination angle. The advantage of the proposed method is that the coefficient β(x) can be identified by lateral dynamic displacement measured in high resolution by the remote sensing vibrometer, which is useful to reconstruct the displacement accurately by the inclination angle under operational conditions
Objective: The utilization of fluorescein-guided biopsies and resection has been recently discussed as a suitable strategy to improve and expedite operative techniques for the resection of central nervous system (CNS) tumors. However, little is known about the optical properties of sodium fluorescein (NaFl) in human tumor tissue and their potential impact on ex vivo analyses involving fluorescence-based methods.
Methods: Tumor tissue was obtained from a study cohort of an observational study on the utilization of fluorescein-guided biopsy and resection (n=5). The optical properties of fluorescein-stained tissue were compared to the optical features of the dye in vitro and in control samples consisting of tumor tissue of high-grade glioma patients (n=3) without intravenous (i.v.) application of NaFl. The dye-exposed tumor tissues were used for optical measurements to confirm the detectability of NaFl emission ex vivo. The tissue samples were fixed in 4%PFA, immersed in 30% sucrose, embedded in Tissue-Tek OCT compound, and cut to 10 mm cryosections. Spatially resolved emission spectra from tumor samples were recorded on representative slides with a Confocal Laser Scanning Microscope FV1000 (Olympus GmbH, Hamburg, Germany) upon excitation with lexc = 488 nm.
Results: Optical measurements of fluorescein in 0.9% sodium chloride (NaCl) under in vitro conditions showed an absorption maximum of lmax abs = 479 nm as detected with spectrophotometer Specord 200 and an emission peak at lmax em = 538 nm recorded with the emCCD detection system of a custom-made microscope-based single particle setup using a 500 nm long-pass filter. Further measurements revealed pH- and concentration-dependent emission spectra of NaFl. Under ex vivo conditions, confocal laser scanning microscopy of fluorescein tumor samples revealed a slight bathochromic shift and a broadening of the emission band.
Conclusion: Tumor uptake of NaFl leads to changes in the optical properties – a bathochromic shift and broadening of the emission band – possibly caused by the dye’s high pH sensitivity and concentration-dependent reabsorption acting as an innerfilter of the dye’s emission, particularly in the short wavelength region of the Emission spectrum where absorption and fluorescence overlap. Understanding the ex vivo optical properties of fluorescein is crucial for testing and validating its further applicability as an optical probe for intravital microscopy, immunofluorescence localization studies, and flow cytometry analysis.
As the most electronegative element, fluorine has a strong influence on material properties such as absorption behaviour or chemical and thermal stability. Fluorine can be easily integrated into coordination polymers (CPs) via a fluorinated acetate, here trifluoroacetate in Ba(CF3COO)2, or directly via a metal fluorine bond (BaF(CH3COO)). In the present study both possibilities of fluorine integration were tested and their effect on structure and properties of barium coordination polymers was investigated in comparison with the non-fluorinated barium acetate (Ba(CH3COO)2). In addition to the study of their thermal behaviour and their decomposition temperature, the CPs structures were tested for their application as possible anode materials in lithium ion batteries and for their sorption of water and ammonia. The properties of the CPs can be traced back to the individual structural motifs and could thus trigger new design ideas for CPs in LIBs and/or catalysis.
Investigation on Wall Thickness Ranges Using Digital Radiography for Tangential Projection Technique
(2018)
X-ray testing is based on the attenuation of X-rays when passing through matter. Image detectors acquire the X-ray information which is defined by the local penetrated wall thickness of the tested sample. By X-ray absorption in the detector and following read-out and digitization steps a digital image is generated. As detectors a radiographic film and film digitization, a storage phosphor imaging plate and a special Laser scanner (Computer Radiography - CR) or a digital detector array (DDA) can be used. The digital image in the computer can then be further analyzed using many types of image processing. In the presented work the automated evaluation of wall thickness profiles are investigated using a test steel pipe with 9 different wall thicknesses and various X-ray voltages and different filter materials at the tube port and intermediate between object and detector. In this way the influence of different radiation qualities on the accuracy of the automated wall thickness evaluation depending on the penetrated wall thickness of the steel pipe was investigated.
The first international round-robin exercise for the measurement of the long-lived radionuclide 10Be has been conducted. Ten participating accelerator mass spectrometry (AMS) facilities have each measured three samples at the 10-12 to 10-14 10Be/9Be level. All results have been made traceable to the NIST SRM 4325 standard to avoid additional discrepancies that arise when different facilities use different calibration materials. Hence, the data concentrates on pure measurement distinctions. Multivariate statistical investigations have been performed to reveal a bias between facilities, i.e. two distinguished groups could be identified. Maximum discrepancies between two single facilities are in the range of 6–31% depending on the absolute 10Be/9Be value. These findings should be considered when comparing 10Be data produced at one AMS facility with that produced at another facility, which is e.g. often the case for in situ 10Be dating studies. Round-robin exercises are a very helpful tool as part of an overall quality assurance scheme to improve the accuracy, and not only the precision, of AMS data.