Analytische Chemie
Filtern
Erscheinungsjahr
- 2007 (10) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (2)
- Beitrag zu einem Tagungsband (2)
- Newsletter (2)
- Posterpräsentation (2)
- Forschungsbericht (2)
Sprache
- Englisch (6)
- Deutsch (2)
- Mehrsprachig (2)
Schlagworte
- AFM (1)
- Aflatoxin (1)
- Antibody (1)
- Antigen (1)
- Computed tomography (1)
- Coordinate metrology (1)
- Crystal orientation (1)
- FIB (1)
- Hapten (1)
- IDMS (1)
Dyke breaks - caused by e.g. Overflows or Slop breaks during long lasting high water gauge - Play a great role in a failure potential of extreme flood Events.
Using conventional dyke condition Monitoring dyke messengers can undertake only a visual surface inspection. Thus defective Areas can oftentimes be discovered too late.
A critical area in which failures due to soil displacement and moisture Penetration become more significant is located at a landside dyke foot. Geotextiles are integrated here as a Drainage in case of modern three-zone type of dyke.
Aflatoxins, a group of structurally related mycotoxins, are well known for their
toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein
conjugates are needed for diverse analytical applications. This work describes a reliable
and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and
characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine
serum albumin conjugates were prepared and characterised by UV absorption and
MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens
for the generation of aflatoxin selective antibodies with novel specificities.
Reinigung wird in der Lebensmittel- und Pharmaindustrie aufgrund des stetig steigenden Kosten- und Zeitdrucks sowie der hohen Verbrauchererwartungen hinsichtlich Produktsicherheit und -haltbarkeit ein immer zentraleres Thema. Eine verbesserte Reinigbarkeit bedeutet für die produzierende Industrie eine Steigerung der Effizienz der Produktionsanlage. Besonders in der heutigen medienintensiven Zeit kommt ein "Lebensmittelskandal" durch ein unsicheres Produkt einem finanziellen Desaster und immensem Imageverlust gleich. Aus diesem Grund ist die Reinigbarkeit der produktberührenden Oberflächen stets ein wichtiges Kriterium für die Werkstoffauswahl.
Basierend auf den Theorien zu Schmutzhaftung und -entfernung wurde im Rahmen dieser Arbeit überprüft, ob und wie die theoretisch relevanten Parameter auch in den Experimenten den Reinigungserfolg beeinflussen. Der Schwerpunkt wurde auf die Einflussgrößen des Werkstoffes gelegt, um herauszufinden, wie stark eine Oberfläche selbst zu ihrer Reinigbarkeit beitragen kann (self-cleaning).
In den durchgeführten Versuchen hat sich gezeigt, dass die Oberflächenrauheit lediglich bei der Reinigung von kohäsiven Schmutzfilmen eine entscheidende Rolle gespielt hat. Hingegen ist ihr Einfluss auf das Reinigungsergebnis von sich auflösenden Schmutzfilmen und Partikeln nur begrenzt bis gar nicht zur Geltung gekommen. Das Oberflächenmaterial hatte keinen starken, aber dennoch signifikanten Einfluss auf die Reinigbarkeit der untersuchten Oberflächen. Dass die Reinigbarkeit einer Oberfläche keine Materialkonstante sein kann, wurde unter Verwendung spezieller Oberflächen mit definiert geätzten Rauheitsstrukturen nachgewiesen. Der Reinigungserfolg hängt immer auch von der Verunreinigungsart ab, was sich auch in vergleichbaren Versuchen der Einzelpartikelablösung mittels AFM in dem Einfluss der Elastizität bzw. Plastizität der Partikeln geäußert hat.
Praxistaugliche Empfehlungen gehören mit zu den wichtigsten Zielen dieser Arbeit gewesen. Mit Fokus auf die Oberflächenparameter und auf Basis der durchgeführten Untersuchungen wurde zur Optimierung der Reinigung produktberührender Oberflächen für bekannte Kontaminationen eine Checkliste als Orientierungshilfe erarbeitet. Ist die Verunreinigungsart dennoch unbekannt, so sollte der "Grenzwert" von Ra = 1 µm unterschritten werden, um bei Vorhandensein filmartiger Verschmutzungen keine negativen Auswirkungen auf die Reinigbarkeit zu haben. Die Notwendigkeit nach hochpolierten Oberflächen (Ra < 0,3 µm) aus Reinigbarkeitsgründen kann aufgrund der Untersuchungen nicht nachvollzogen werden.
Das Ziel des Vorhabens wurde erreicht.
Carrying out dimensional measurements by CT means assessing coordinates in space. CT must therefore be treated as a coordinate measuring technique similar to optical or tactile Coordinate Measuring Machines (CMMs). The well-established standards and guidelines for the acceptance- and verificationtesting of CMMs require the use of calibrated reference standards to achieve measurement machine characteristics.
Hence, transferring these concepts from coordinate metrology to CT, a dedicated CT-specific reference standard was designed, manufactured and calibrated using a tactile CMM. For comparison purposes, a CAD model was created by reverse engineering using the calibration data. The calibrated model was fed into a virtual CT and the measurement process was simulated. The reference standard was measured by micro-CT.
By comparing the characteristics of the measurement output of CT and the output gained from simulation, the influences of measurement artefacts can be judged, for the first time, in analogy to existing Guidelines of coordinate metrology.
We have studied the anisotropic milling of Cu with respect to the milling rate and the milling topography, as well. The background is twofold: i) anisotropic milling has to be taken into account during the preparation of TEM specimens and in the manufacturing of micro parts from crystalline materials, and ii) the orientation depending milling behaviour can be used to generate topographies with specific properties with respect to, for example, adsorption, wear, and corrosion.
A multi-offset radar system will be presented that features the possibility to get quantitative information about the wave propagation velocity as a measure of the ballast quality. This goes beyond the regular application of conventional radar systems offering only qualitative structural information. The new approach provides a fast NDT method for the classification of ballast fouling. A main advantage of the multi-offset radar is that regular ballast digging for velocity evaluation can be avoided and travel time can be directly transformed into an equivalent depth by using the automatically evaluated velocity. The maintenance cost and interruption time can be significantly decreased by this method. The application of velocity evaluation method is common in geophysical applications but it is used for ballast inspection for the first time.
Three petrol reference materials were certified for their total sulfur content in support of Directive 2003/17/EC of the European Parliament and of the European Council, which stipulates that petrol with a maximum S content of 10 mg/kg must be available in all member states by 2009. Commercially available petrol was obtained and filled into borosilicate ampoules without further treatment. Homogeneity of the materials was tested and no heterogeneity was detected for two of the materials, whereas minor heterogeneity was observed for the third material. Stability of the materials was tested for 8-12 months at 60 °C and no degradation was observed. Characterisation was based on isotope-dilution mass spectrometry (IDMS) applied as primary method of measurement by three European metrology institutes and certified values were assigned using all results. The certified uncertainties include contributions of (potential) heterogeneity, potential degradation as well as characterisation. The final assigned values are:
ERM-EF211: 48.8 ± 1.7 mg/kg
ERM-EF212: 20.2 ± 1.1 mg/kg
ERM-EF213: 9.1 ± 0.8 mg/kg
The materials are available from IRMM (ERM-EF211), LGC (ERM-EF212) and BAM (ERMEF213)