1.0 Abteilungsleitung und andere
Filtern
Dokumenttyp
- Vortrag (6)
- Zeitschriftenartikel (4)
- Sonstiges (1)
- Posterpräsentation (1)
Referierte Publikation
- nein (12) (entfernen)
Schlagworte
- HR-CS-MAS (3)
- Isotope (3)
- Spectrometry (3)
- Mono-hydride (2)
- Size (2)
- ACE2 (1)
- Absolute fluorometry (1)
- BAM Data Store (1)
- Boron monohydride (1)
- COVID-19 (1)
- Corona (1)
- Coronavirus (1)
- Cubical shape (1)
- DNA Origami (1)
- Deactivation pathways (1)
- Durchflusszytometrie (1)
- ELISA (1)
- Easy-use device (1)
- Einzelmolekülspektroskopie (1)
- Electron microscopy (1)
- Electronic lab notebook (ELN) (1)
- Elektronisches Laborbuch (1)
- Fluorescence (1)
- Forschungsdatenmanagement (1)
- Gasanalytik (1)
- Gasgualität (1)
- Gasreinheit (1)
- IR (1)
- ISO/TC 229 Nanotechnologies (1)
- Integrating sphere spectroscopy (1)
- Iron oxide (1)
- Isotopic shift (1)
- LFIA (1)
- Magnesium monofluoride (1)
- Modeling (1)
- Molecular absorption spectrometry (1)
- Mutationen (1)
- NIR (1)
- Nano CRM (1)
- Nano@BAM (1)
- NanoPlattform (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Nanotechnologie (1)
- Neutralisierende Antikörper (1)
- Normung (1)
- Nucleocapsid-Protein (1)
- Oberflächen verstärkte Raman Streuung (1)
- OpenBIS (1)
- Partikel (1)
- Proteine (1)
- RBD (1)
- Reference data (1)
- Reference materials (1)
- Reference nanoparticles (1)
- Reference procedures (1)
- Regel- und Messtechnik (1)
- Research data management (1)
- SAFIA (1)
- SARS-CoV-2 (1)
- SAXS (1)
- Spike-Protein (1)
- Surface chemistry (1)
- Upconversion (1)
- Virus (1)
- Zertifikat (1)
- reference materials, requirements, guidance (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (12)
- 1.0 Abteilungsleitung und andere (12)
- 1.1 Anorganische Spurenanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- 4 Material und Umwelt (3)
- 4.2 Material-Mikrobiom Wechselwirkungen (3)
- 1.2 Biophotonik (2)
- 6 Materialchemie (2)
- 6.1 Oberflächen- und Dünnschichtanalyse (2)
- 1.5 Proteinanalytik (1)
Eingeladener Vortrag
- nein (6)
Angesichts der zunehmenden Digitalisierung und dem Einsatz datenintensiver Methodiken in der Wissenschaft stehen Forschende vor der Herausforderung, stetig wachsende Datenmengen nachvollziehbar zu dokumentieren, langfristig zu speichern und für Dritte nachnutzbar zu machen. Um diesen Anforderungen gerecht zu werden, bietet sich die Nutzung von Software-Lösungen an, welche Forschungsdatenmanagement mit der digitalen Dokumentation von Laborinventar und Experimenten in elektronischen Laborbüchern (engl. electronic lab notebooks (ELN)) verknüpfen.
In dieser Arbeit werden die Grundlagen der Normung, die Entstehung einer Norm und die für die Gasanalytik relevanten Normungsgremien kurz dargestellt. Dazu werden die wichtigsten Normen zur Gasanalytik entlang des analytischen Prozesses gruppiert und aufgeführt. Schließlich wird als Anwendungsbeispiel aus der eigenen Praxis der Prozess von der Herstellung bis zur Zertifizierung eines Kalibriergases beschrieben.
BAM is currently building up a platform of novel nanoRMs relying on iron oxide nanoparticles of different shape, size and surface chemistry. Iron oxide was chosen as a core material because of its relevance to the material and life sciences.
As a first candidate of this series, we present cubic iron oxide nanoparticles with a nominal edge length of 8 nm. These particles were synthesized by thermal decomposition of iron oleate in high boiling organic solvents adapting well-known literature procedures. After dilution to a concentration suitable for electron microscopy (TEM and SEM) as well as for small-angle X-ray scattering (SAXS) measurements, the candidate nanoRM was bottled and assessed for homogeneity and stability by both methods following the guidelines of ISO 17034 and ISO Guide 35.
The particle sizes obtained by both STEM-in-SEM and TEM are in excellent agreement with a minimum Feret of 8.3 nm ± 0.7 nm. The aspect ratio (AR) of the iron oxide cubes were extracted from the images as the ratio of minimum Feret to Feret resulting in an AR of 1.18 for TEM to 1.25 for SEM. Alternatively, a rectangular bounding box was fitted originating from the minimum Feret and the longest distance through the particle in perpendicular direction. This led to AR values of 1.05 for TEM and 1.12 for SEM, respectively. The results confirm the almost ideal cubic shape.
Mass spectrometric methods (MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
We propose a lower-cost and faster optical alternative for the analysis of isotope ratios of selected elements: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated mono-hydrides and halide (MH and MX) using graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. The extension of this methodology to other elements like Li, Ca, Cu, and Sr is discussed.
Small variations in the isotopic composition of some elements have been used as proof of provenance of mineral and biological samples, to describe geological processes, and to estimate a contamination source. Routinely, isotope compositions are measured by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time-consuming and they require a high qualified analyst.
Here, an alternative faster and low-cost optical method for isotope ratio determination is investigated: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X = Li, B, Mg, Ca and Sr have been determined by monitoring the absorption spectra of their in situ generated hydrides (XH) in graphite furnace HR-CS-MAS. For example, the system of two stable isotopes of boron (10B and 11B) was studied via its hydride for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, isotopic composition of samples and reference materials are calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results are metrologically compatible with those reported by mass spectrometric methods. [1] Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shift of their isotopologues can be resolved as shown in Fig.1 b. The extension of this methodology to other elements like Li, Ca and Sr is discussed [2].
References:
[1] C. Abad, S. Florek, H. Becker-Ross, M.-D. Huang, H.-J. Heinrich, S. Recknagel, J. Vogl, N. Jakubowski, U. Panne, Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers, Spectrochim. Acta, Part B, 136 (2017) 116-122.
[2] C. Abad et al., unpublished results, 2018.
We propose an alternative faster and low-cost optical method for isotope analysis: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS).
Stable isotope amount composition of X = Li, B, Mg, Ca and Sr were determined by monitoring the absorption spectra of their in situ generated mono-hydrides (XH) in graphite furnace HR-CS-MAS. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results with an accuracy of 0.15 ‰ are metrologically compatible with those reported by mass spectrometric methods. Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved as shown in Fig.1b. The extension of this methodology to other elements like Li, Ca and Sr is discussed.