Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2018 (66) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (66) (entfernen)
Schlagworte
- Fluorescence (8)
- Laser ablation (5)
- ICP-MS (4)
- Mechanochemistry (4)
- Mass spectrometry (3)
- Mass-Spectrometry (3)
- Nanoparticle (3)
- Quantum yield (3)
- Abwasser (2)
- Bioimaging (2)
- Cells (2)
- Copper (2)
- ELISA (2)
- HRMS (2)
- Immunohistochemistry (2)
- In situ (2)
- LA-ICP-MS (2)
- LC-MS/MS (2)
- Mercury (2)
- Metrology (2)
- Microplastic (2)
- Mobile phase (2)
- Mycotoxin (2)
- Oxygen sensor (2)
- Photodegradation (2)
- Purity (2)
- Purity assessment (2)
- Quantification (2)
- Reference material (2)
- Traceability (2)
- Transformation products (2)
- Tumor metabolism (2)
- XRD (2)
- AG nanoparticle (1)
- ANOVA (1)
- ATCUN (1)
- AU nanoparticle (1)
- Absorption spectrometry (1)
- Adsorption (1)
- Affinity chromatography (1)
- Affinity extraction (1)
- Albumin (1)
- Aluminum (1)
- Amyloid (1)
- Anilinopyridine (1)
- Anion receptors (1)
- Antikensammlung Berlin (1)
- Arsenite (1)
- Aspergillus (1)
- Atomic Force Microscopy (1)
- BLE Bluetooth low energy (1)
- Bakterien (1)
- Barium (1)
- Basic solvent (1)
- Benchtop NMR Spectroscopy (1)
- Big Data (1)
- Bioconjugation (1)
- Biosynthesis (1)
- Biotests (1)
- Biotransformation (1)
- Bisphenol A (1)
- Block copolymer (1)
- CCQM key comparison (1)
- CONSENS (1)
- CRM (1)
- Calcium monofluoride (1)
- Carbodiimide crosslinking (1)
- Cell (1)
- Charge Transfer (1)
- Chemical sensors (1)
- Chemical transformation (1)
- Chicken antibodies (1)
- Chromatography (1)
- Chronic kidney disease (1)
- Classification (1)
- Colorimetric Test (1)
- Complex (1)
- Complexation (1)
- Conjugate (1)
- Coordination polymers (1)
- Core-shell particles (1)
- Coulometric sensors (1)
- Coumarin (1)
- Coupling reactions (1)
- Cr(III) (1)
- Cr(III) complex (1)
- Cyanide (1)
- Cyanide in soil (1)
- Cyclization (1)
- D-glucose (1)
- DC-Arc (1)
- DEA (1)
- DNA (1)
- Datenanalyse (1)
- Datenkonzepte (1)
- Diagnostics (1)
- Diclofenac (1)
- Digitalisierung (1)
- Dimerization (1)
- Dip-stick assay (1)
- Direct metal assay (1)
- Droplets (1)
- Drug transporters (1)
- Dye (1)
- Dyes/pigments (1)
- E. coli (1)
- EC/LC/MS (1)
- EPR spectroscopy (1)
- Ecotoxicity (1)
- Einzelzellanalyse (1)
- Electrochemical oxidation (1)
- Electrochemistry mass spectrometry (1)
- Elektronenmikroskopie (1)
- Emerging/novel brominated flame retardant (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Ethyl glucuronide (1)
- Exposure (1)
- FTIR spectroscopy (1)
- Fatty acid metabolism (1)
- Fe nanoparticles metabolism (1)
- Fenton (1)
- Festphasenextraktion (1)
- Fluorescence lifetime (1)
- Fluorescence sensing (1)
- Fluorine (1)
- Fluxomics (1)
- Folic acid (1)
- Formulation additives (1)
- Fungicide (1)
- Fusarium (1)
- Graphit (1)
- Graphite furnace (1)
- Greek curse tablets (1)
- Group profile (1)
- HPLC (1)
- HPLC-DAD/FLD (1)
- HPLC-ICP-MS (1)
- HPLC-MS (1)
- HPLC–MS (1)
- HR-CS-MAS (1)
- Hierarchical cluster analysis (1)
- High pH (1)
- High purity (1)
- High-purity elements (1)
- Hormone (1)
- ICP-MS/MS (1)
- IDMS (1)
- IgY (1)
- Imaging (1)
- Immunoaffinity extraction (1)
- Immunoassay (1)
- Impurity assessment (1)
- In situ studies (1)
- Indirect Hard Modeling (1)
- Interlaboratory comparison (1)
- Iron Complex (1)
- Iron disorders (1)
- Isotope dilution mass spectrometry (1)
- Isotopic dilution (1)
- Job plot (1)
- Kidney (1)
- Kläranlage (1)
- Konjugate (1)
- Künstlicher Intelligenz (1)
- L-alanine (1)
- LIBS (1)
- Lanthanide (1)
- Laser (1)
- Lead isotopes (1)
- Lebensmittel (1)
- Lifetime (1)
- Ligand design (1)
- Lipidomic profile (1)
- Liquid chromatography (1)
- Low energy electrons (1)
- Luminescence (1)
- Luminescence lifetime (1)
- MALDI Imaging MS (1)
- MALDI-TOF MS (1)
- MALDI-ToF-MS (1)
- MAS NMR spectroscopy (1)
- MYCN (1)
- Magnetic nanocatalyst (1)
- Magnetically stabilized (1)
- Maillard reaction (1)
- Mass-spectrometry (1)
- Matrixeffekte (1)
- Measurement uncertainty (1)
- Measuremment uncertainty (1)
- Mechanochemical synthesis (1)
- Melanoidin (1)
- Melanoidine (1)
- Mesoporous materials (1)
- Metabolic stress (1)
- Metabolism (1)
- Metabolization (1)
- Metal nanoclusters (1)
- Metal nanoparticles (1)
- Metalloprotein (1)
- Metals (1)
- Microfluidics (1)
- Moisture measurements (1)
- Molecular dynamics simulations (1)
- Molecular imprinting (1)
- Molecularly imprinted polymers (1)
- Molecule (1)
- Multimodal (1)
- Multivariate Statistics (1)
- Mycotoxins (1)
- NIR (1)
- NIR emitter (1)
- NMR (1)
- NMR spectroscopy (1)
- Nanocluster (1)
- Nanomaterials (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nickel (1)
- Non-metal analysis (1)
- Oberflächenwasser (1)
- Online NMR spectroscopy (1)
- Optical emission spectroscopy (1)
- P-aminothiophenol (1)
- PXRD (1)
- Partial Least Squares Regression (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Pb isotopes (1)
- Peptide (1)
- Peptide analysis (1)
- Peptide library screening (1)
- Peptide losses (1)
- Photodynamische Inaktivierung (1)
- Photokatalyse (1)
- Photosensibilisator (1)
- Phthalocyanin (1)
- Plasma (1)
- Plasma modeling (1)
- Pollen (1)
- Pollen grains (1)
- Polymer membrane (1)
- Polymorphs (1)
- Porphyrin (1)
- Principal component analysis (1)
- Principal component analysis (PCA) (1)
- Probe (1)
- Probenvorbereitung (1)
- Process analytical technology (1)
- Proficiency testing (1)
- Protein imaging (1)
- Prozessindustrie (1)
- Pt-based drugs (1)
- Pulverization (1)
- QC (1)
- Quality control (1)
- R package (1)
- RSSI Received Signal Strength Indicator (1)
- Rational design (1)
- Recovery (1)
- Reference measurements (1)
- Reproducibility (1)
- Rhizopus (1)
- Rhodamine (1)
- Round robin exercise (1)
- SDHI-fungicide (1)
- SI-traceability (1)
- Sample treatment (1)
- Sensor network (1)
- Sers (1)
- Sewage treatment plant (1)
- Silanization (1)
- Silbernanopartikel (1)
- Silver nanoparticles (1)
- Single cell analysis (1)
- Single-cell analysis (1)
- Smart Sensors (1)
- Society of hair testing (1)
- Solid-phase extraction (1)
- Species-unspecific on-line isotope dilution (1)
- Spectroscopy (1)
- Standardization (1)
- Structural Health Monitoring (1)
- Synthesis (1)
- TED-GC-MS (1)
- Test strips (1)
- Thin tissue sections (1)
- Tire wear (1)
- Tissue soldering (1)
- Total cyanide (1)
- Toxicity (1)
- Toxicity testing (1)
- Trace humdity measurement (1)
- Tutzing-Symposion (1)
- Uncertainty (1)
- Validation (1)
- Validierung (1)
- Viscosity (1)
- Xerogel (1)
- Zearalenone (1)
- Zirconium (1)
- Zyklisierung (1)
- pH sensor (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (54)
- 1.1 Anorganische Spurenanalytik (21)
- 6 Materialchemie (17)
- 6.3 Strukturanalytik (14)
- 1.7 Organische Spuren- und Lebensmittelanalytik (13)
- 1.8 Umweltanalytik (9)
- P Präsident (7)
- P.0 Präsident und andere (7)
- 1.9 Chemische und optische Sensorik (6)
- 1.2 Biophotonik (5)
Laser tissue soldering (LTS) based on indocyanine green (ICG)-mediated heat- denaturation of proteins might be a promising alternative technique for micro-suturing, but up to now the Problem of too weak shear strength of the solder welds in comparison to sutures is not solved. Earlier reports gave promising results showing that solder supported by carrier materials can enhance the cohesive strength of the liquid solder. In these studies, the solder was applied to the carriers by dip coating. Higher reliability of the connection between the solder and the carrier material is expected when the solder is bound covalently to the carrier material. In the present study a poly(ether imide) (PEI) membrane served as carrier material and ICG- supplemented albumin as solder substrate. The latter was covalently coupled to the carrier membrane under physiological conditions to prevent structural protein changes. As laser source a diode continuous-wave laser emitting at 808 nm with intensities between 250mW and 1500mW was utilized. The Albumin functionalized carrier membrane was placed onto the tunica media of explanted pig thoracic aortae forming an overlapping area of approximately 0.5×0.5 cm2. All tests were performed in a dry state to prevent laser light absorption by water. Infrared spectroscopy, spectro-photometrical determination of the secondary and Primary amine groups after acid orange II staining, contact angle measurements, and atomic force microscopy proved the successful functionalization of the PEI membrane with albumin. A laser power of 450mW LTS could generate a membrane-blood vessel connection which was characterized by a shear strength of 0.08±0.002MPa, corresponding to 15% of the tensile strength of the native blood vessel. Theoretically, an overlapping zone of 4.1mmaround the entire circumference of the blood vessel could have provided shear strength of the PEI membrane-blood vessel compound identical to the tensile strength of the native blood vessel. These in-vitro results confirmed the beneficial effects of solder reinforcement by carrier membranes, and suggest LTS with covalently bound solders on PEI substrates for further studies in animal models.
Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the sticky character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing an LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend an LC-MS/MS-based quantification method with a dynamic range of 0.5–40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials.
The comparison required the assignment of the mass fraction of folic acid present as the main component in the comparison sample. Performance in the comparison is representative of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molecular weight range 300–500] and high polarity (pKOW < −2).
Methods used by the eighteen participating NMIs or DIs were based on a mass balance (summation of impurities) or qNMR approach, or the combination of data obtained using both methods. The qNMR results tended to give slightly lower values for the content of folic acid, albeit with larger associated uncertainties, compared with the results obtained by mass balance procedures. Possible reasons for this divergence are discussed in the report, without reaching a definitive conclusion as to their origin.
The comparison demonstrates that for a structurally complex polar organic compound containing a high water content and presenting a number of additional analytical challenges, the assignment of the mass fraction content property value of the main component can reasonably be achieved with an associated relative standard uncertainty in the assigned value of 0.5%
The increasing request for hair ethyl glucuronide (HEtG) in alcohol consumption monitoring according to cut-off levels set by the Society of Hair Testing (SoHT) has triggered a proficiency testing program based on interlaboratory comparisons (ILC). Here, the outcome of nine consecutive ILC rounds organised by the SoHT on the determination of HEtG between 2011 and 2017 is summarised regarding interlaboratory reproducibility and the influence of procedural variants. Test samples prepared from cut hair (1 mm) with authentic (in-vivo incorporated) and soaked (in-vitro incorporated) HEtG concentrations up to 80 pg/mg were provided for 27–35 participating laboratories. Laboratory results were evaluated according to ISO 5725-5 and provided robust averages and relative reproducibility standard deviations typically between 20 and 35% in reasonable accordance with the prediction of the Horwitz model. Evaluation of results regarding the analytical techniques revealed no significant differences between gas and liquid chromatographic methods In contrast, a detailed evaluation of different sample preparations revealed significantly higher average values in case when pulverised hair is tested compared to cut hair. This observation was reinforced over the different ILC rounds and can be attributed to the increased acceptance and routine of hair pulverisation among laboratories. Further, the reproducibility standard deviations among laboratories performing pulverisation were on average in very good agreement with the prediction of the Horwitz model. Use of sonication showed no effect on the HEtG extraction yield.
A series of new Ba-based coordination polymers (CPs) were mechanochemically synthesized by milling Ba-hydroxide samples with perfluorinated and fluorine-free benzene-dicarboxylic acids, including tetrafluoroisophthalic acid (H2mBDC-F4), tetrafluorophthalic acid (H2oBDC-F4), isophthalic acid (H2mBDC) and phthalic acid (H2oBDC). The new fluorinated CPs: [Ba(mBDC-F4)$0.5H2O] (1) and [Ba(oBDC-F4)·1.5H2O] (2) are compared to their nonfluorinated counterparts: [Ba(mBDC)·2.5H2O] (3), and [Ba(oBDC)·1H2O] (4). These materials are thoroughly characterized using powder X-ray diffraction. The products obtained by milling are all hydrated but vary in their water contents. Compositions and local structures are investigated by elemental analysis, thermal analysis, MAS NMR and attenuated total reflectioninfrared spectroscopy. These materials exhibit high thermal stabilities but small surface areas that remain unchanged even after thermal treatments.
Monitoring specific chemical properties is the key to chemical process control. Today, mainly optical online methods are applied, which require time- and cost-intensive calibration effort. NMR spectroscopy, with its advantage being a direct comparison method without need for calibration, has a high potential for closed-loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and rough environments for process monitoring and advanced process control strategies.
We present a fully automated data analysis approach which is completely based on physically motivated spectral models as first principles information (Indirect Hard Modelling – IHM) and applied it to a given pharmaceutical lithiation reaction in the framework of the European Union’s Horizon 2020 project CONSENS. Online low-field NMR (LF NMR) data was analysed by IHM with low calibration effort, compared to a multivariate PLS-R (Partial Least Squares Regression) approach, and both validated using online high-field NMR (HF NMR) spectroscopy.
Cost-effective water cleaning approaches using improved Treatment technologies, for instance based on catalytic processes with high activity catalysts, are urgently needed. The aim of our study was to synthesize efficient Fenton-like photo-catalysts for rapid degradation of persistent organic micropollutants in aqueous medium. Iron-based nanomaterials were chemically synthesized through simple procedures by immobilization of either iron(II) oxalate (FeO) or iron(III) citrate (FeC) on magnetite (M) nanoparticles stabilized with polyethylene glycol (PEG). Various investigation techniques were performed in order to characterize the freshly prepared catalysts. By applying advanced oxidation processes, the effect of catalyst dosage, hydrogen peroxide concentration and UV-A light exposure were examined for Bisphenol A (BPA) conversion, at laboratory scale, in mild conditions. The obtained results revealed that BPA degradation was rapidly enhanced in the presence of low-concentration H2O2, as well as under UV-A light, and is highly dependent on the surface characteristics of the catalyst. Complete photo-degradation of BPA was achieved over the M/PEG/FeO catalyst in less than 15 minutes. Based on the catalytic performance, a hierarchy of the tested catalysts was established: M/PEG/FeO > M/PEG/FeC > M/PEG. The results of cytotoxicity assay using MCF-7 cells indicated that the aqueous samples after treatment are less cytotoxic.
2-Amino-2-(hydroxymethyl)-1,3-propanediol (TRIS) and ethylene-diaminetetraacetic acid (EDTA) are key components of biological buffers and are frequently used as DNA stabilizers in irradiation studies. Such surface or liquid phase studies are done with the aim to understand the fundamental mechanisms of DNA radiation damage and to improve cancer radiotherapy. When ionizing radiation is used, abundant secondary electrons are formed during the irradiation process, which are able to attach to the molecular compounds present on the surface. In the present study we experimentally investigate low energy electron attachment to TRIS and methyliminodiacetic acid (MIDA), an analogue of EDTA, supported by quantum chemical calculations. The most prominent dissociation channel for TRIS is through hydroperoxyl radical formation, whereas the dissociation of MIDA results in the formation of formic and acetic acid. These compounds are well-known to cause DNA modifications, like strand breaks. The present results indicate that buffer compounds may not have an exclusive protecting effect on DNA as suggested previously.
New Ca- and Sr-based coordination polymers (CPs) were mechanochemically synthesized by milling metal hydroxide samples (M = Ca, Sr) with tetrafluorophthalic acid (H2oBDC-F4) and isophthalic acid (H2mBDC). [Ca(oBDC-F4)(H2O)2] (1) exhibits a small surface area which is slightly increased after removing the crystal water. On the other hand, the hydrated sample of the nonfluorinated [Sr(mBDC)(H2O)3.4] (2) reveals a small BET surface area which remains unchanged even after the release of crystal water via thermal treatment. The new compounds 1 and 2 are similar to their Sr- and Ca-analogs, respectively. These findings are confirmed by thermal analysis, MAS NMR, and ATR-IR measurements, in addition to the Le Bail refinements for the measured powder X-ray data of 1 and 2. Ca- and Sr-CPs based on perfluorinated dicarboxylic systems and their nonfluorinated analogs diverse in structural and chemical properties depending on the geometries of the organic linkers and the presence of fluorine atoms. The fluorinations of organic ligands lead to the formation of fluorinated CPs with higher dimensionalities compared to their nonfluorinated counterparts. Conversely, the thermal stabilities of the latter are higher than those of the fluorinated CPs.
An immunohistochemical method is described to visualize the distribution of metallothioneins 1/2 (MT 1/2) and metallothionein 3 (MT 3) in human ocular tissue. It is making use of (a) antibodies conjugated to gold nanoclusters (AuNCs) acting as labels, and (b) laser ablation (LA) coupled to inductively coupled plasma – mass spectrometry (ICP-MS). Water-soluble fluorescent AuNCs (with an average size of 2.7 nm) were synthesized and then conjugated to antibody by carbodiimide coupling. The surface of the modified AuNCs was then blocked with hydroxylamine to avoid nonspecific interactions with biological tissue. Immunoassays for MT 1/2 and MT 3 in ocular tissue sections (5 μm thick) from two post mortem human donors were performed. Imaging studies were then performed by fluorescence using confocal microscopy, and LA-ICP-MS was performed in the retina to measure the signal for gold. Signal amplification by the >500 gold atoms in each nanocluster allowed the antigens (MT 1/2 and MT 3) to be imaged by LA-ICP-MS using a laser spot size as small as 4 μm. The image patterns found in retina are in good agreement with those obtained by conventional fluorescence immunohistochemistry which was used as an established reference method.