High-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GF-MAS) was employed for determining adsorbable organic chlorine (AOCl) in water. Organic chlorine was indirectly quantified by monitoring the molecular absorption of the transient aluminum monochloride molecule (AlCl) around a wavelength of 261.42 nm in a graphite furnace. An aluminum solution was used as the molecularforming modifier. A zirconium coated graphite furnace, as well as Sr and Ag solutions were applied as modifiers for a maximal enhancement of the absorption signal. The pyrolysis and vaporization temperatures were 600 °C and 2300 °C, respectively. Non-spectral interferences were observed with F, Br, and I at concentrations higher than 6 mg L-1, 50 mg L-1, and 100 mg L-1, respectively. Calibration curves with NaCl, 4-chlorophenol, and trichlorophenol present the same slope and dynamic range, which indicates the chlorine atom specificity of the method. This method was evaluated and validated using synthetic water samples, following the current standard DIN EN ISO 9562:2004 for the determination of the sum parameter adsorbable organic halides (AOX) for water quality. These samples contain 4-chlorophenol as the chlorinated organic standard in an inorganic chloride matrix. Prior to analysis, organic chlorine was extracted from the inorganic matrix via solid-phase extraction with a recovery rate >95%. There were no statistically significant differences observed between measured and known values and for a t-test a confidence level of 95% was achieved. The limits of detection and characteristic mass were found to be 48 and 22 pg, respectively. The calibration curve was linear in the range 0.1–2.5 ng with a correlation coefficient R2 = 0.9986.
The occurrence of microplastic particles (MP) in nearly each environmental compartment but especially in water is well documented in an increasing amount of publication within the last few years. However, a comprehensive understanding of MP occurrence, sources and pathways in the environment as well as effects of MP on the environment is still unclear. Many of the studies are not compatible, because they used different sampling, sample preparation and detection techniques, resulting in a very broad variation and very different dimension of archived results. Hence a useful avoiding strategy for reduction the MP entry in the environment is not possible. Furthermore, the existing methods are often very time consuming, need user knowledge and labour force, which is often not acceptable for the routine monitoring of an action or sanction.
The call for harmonised methods become loud and louder and promising efforts are done in this area. However, the scientific discussion is often focus on advantages and disadvantages of detection tools and sample preparation, less initiative is given to the sampling strategy. That is a pity, because every environmental scientist knows, a good analytical result depend on a good sampling strategy.
The sampling of water seems on the first view easy because the sampling process include already an up concentration of the MP by means of sieves and filters. However, this filtering of water is often limited by filter cake on the sieves, consisting of high amount of natural particular matter. Hence often a small water volume is filtered, which will not own a representative amount of trait carriers or complex sieves cascades are used, which need a high technical equipment.
Recently we presented a fast thermoanalytical method for the detection of polymers fractions in water samples. This method, thermo-extraction desorption gas chromatography mass spectrometry (TED-GC-MS) can analyse MP in water filtrates without sample preparations within 2-3 hours. Advantageous is the additional analysis of rubber particles from tires beside the MP. In order to come even faster we now start to develop new sampling strategies, which should be use for different water systems. It is intended to reduce the effort in the field and to elongate times for sampling to obtain a representatives result without random effects.
In the present presentation we will show first result using a sedimentation box for sampling of MP from surface water. Advantages and disadvantages will be discussed and comparison to data from conventional fractionated filtration will be given.
A harmonization of sampling, sample preparation and detection is pivotal in order to obtain comparable data on microplastics (MP) in the environment. This paper develops and proposes a suitable sampling concept for waterbodies that considers different plastic specific properties and influencing factors in the environment.
Both artificial water including defined MP fractions and the discharge of a wastewater treatment plant were used to verify the derived sampling procedure, sample preparation and the subsequent analysis of MP using thermal extraction-desorption gas chromatography - mass spectrometry (TED-GC-MS).
A major finding of this paper is that an application of various particle size classes greatly improves the practical handling of the sampling equipment. Size classes also enable the TED-GC-MS to provide any data on the MP size distribution, a substantial sampling property affecting both the necessary sampling volume and the optimal sampling depth.
In the artificial water with defined MP fractions, the recovery rates ranged from 80 to 110%, depending on the different MP types and MP size classes. In the treated wastewater, we found both Polyethylene and polystyrene in different size classes and quantities.
Quantifizierung der Schädigung von DNA in wässriger Lösung unter direkter Elektronenbestrahlung
(2018)
To cure cancer radiation therapy is used to kill tumor cells.
It is based on radiation induced damage to biomolecules.
Especially DNA damage is of key interest due to its central role in apoptosis and mutation.
Because of the high amount of water in biological tissue, most of the damage is caused by the secondary particles produced by the inelastic scattering of ionizing radiation and water.
A detailed understanding of the underlying molecular processes under physiological conditions is the prerequisite to develop more efficient therapies.
Goal of this work is to quantify the DNA damage caused by ionizing radiation in dependence of the inelastic scattering events and the energy deposit within the microscopic target volume of biological relevance.
The irradiations have to be performed in liquid, under consideration of the chemical environment.
Therefore, a new combination of experiment and Monte-Carlo simulations was developed and tested.
To make it possible to irradiate liquids with electrons within scanning electron microscopes a new sample holder was constructed incorporating an electron transparent nanomembrane.
It makes it possible to irradiate DNA, proteins or cells at different pH, salinity and in the presence of cosolutes.
%The most important results of this work are as follows:
The median lethal dose for a model system of plasmid DNA and water was determined by the combination of experimental data, particle scattering simulations (Geant4-DNA) and diffusion calculations as D0.5=(1.7+-0.3) Gy.
From the convolution of plasmid positions and the spatially resolved energy deposit, as determined by electron scattering simulations, the histogram of the energy deposit within the target volume of the plasmids and the microscopic median lethal energy deposit was calculated as E0.5=6+-4eV.
It could be deduced that on average less than two ionization events are sufficient to cause a single-strand-break.
The relation of single-strand-breaks (SSB) to double-strand-breaks (DSB), which is of importance for microdosimetric modeling, was determined as SSB:DSB = 12:1.
The presented method for the determination of microscopic dose-damage relations was further extended to be applicable for general irradiation experiments.
It becomes independent of the type of primary radiation used, the experimental geometry, and the diffusional properties of the molecules under investigation.
This way different experimental systems with varying, inhomogeneous energy deposit characteristics become comparable with each other, which is not possible when only macroscopic averaged values are taken into account.
In addition, the radiation protection properties of the compatible solute ectoine, as well as its influence on the water properties and biomolecules were investigated.
%In addition, the influence of the compatible solute ectoine on water, biomolecules and its radiation protection properties were investigated.
Raman spectroscopy revealed a concentration dependent increase of the collective water modes in the OH-stretching region, which was found to be independent of the sodium chloride concentration.
Molecular dynamic simulations showed that the zwitterionic properties of ectoine lead to its half-chair conformation.
The hydrogen bonds in the first hydration shell are more stable and have an increased lifetime compared to the bulk water.
Irradiation experiments with DNA in the presence of 1M ectoine revealed an increase of the survival rate by a factor of 1.41 as compared to the absence of ectoine.
The protective properties of ectoine result from the increase of the inelastic scattering probabilities of low energy electrons at the acoustic vibrational modes of water and its properties as OH-radical scavenger.
This was shown by Raman spectroscopy and electron paramagnetic resonance measurements (EPR).