Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2020 (111) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (62)
- Vortrag (28)
- Posterpräsentation (14)
- Forschungsdatensatz (2)
- Beitrag zu einem Tagungsband (1)
- Dissertation (1)
- Sonstiges (1)
- Preprint (1)
- Forschungsbericht (1)
Sprache
- Englisch (96)
- Deutsch (13)
- Mehrsprachig (1)
- Polnisch (1)
Schlagworte
- BAMline (10)
- Synchrotron (8)
- Machine learning (7)
- XRF (7)
- Absolute isotope ratio (5)
- Benchtop-NMR (5)
- Capillary electrophoresis (5)
- ICP-MS (5)
- Automation (4)
- Metrology (4)
- Artificial neural networks (3)
- Fluorescence (3)
- Hyphenated techniques (3)
- Isotope ratio (3)
- Isotopic analysis (3)
- Magnetic resonance imaging (3)
- Mass-Spectrometry (3)
- NMR spectroscopy (3)
- NMR-Spektroskopie (3)
- Nanoparticle (3)
- Online NMR spectroscopy (3)
- Process Analytical Technology (3)
- Process industry (3)
- Prozessanalytik (3)
- Real-time process monitoring (3)
- SPE HR-CS GF MAS (3)
- Speciation analysis (3)
- Traceability (3)
- Adsorbable organically bound fluorine (AOF) (2)
- Aktivkohle (2)
- Batteries (2)
- CCQM (2)
- Calibration (2)
- Cancer (2)
- Combustion ion chromatography (CIC) (2)
- Diagnostics (2)
- Diatoms (2)
- Digitalisation (2)
- ELISA (2)
- Extractable organically bound fluorine (EOF) (2)
- HR-CS-AAS (2)
- Herkunftsbestimmung (2)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (2)
- Immunoassay (2)
- In situ (2)
- Industry 4.0 (2)
- Isotope (2)
- Isotope analysis (2)
- Isotopenanalyse (2)
- Isotopes (2)
- Lab of the Future (2)
- Lab-on-a-chip (2)
- Laser ablation (2)
- Lithium batteries (2)
- MALDI-TOF MS (2)
- Mass spectrometry (2)
- Microdroplet generator (2)
- Microplastic (2)
- Molar mass (2)
- Multicollector-ICP-MS (2)
- Optischer Spektroskopie (2)
- Per- and polyfluorinated alkyl substances (PFASs) (2)
- Permethrin (2)
- Process Industry (2)
- Quality Control (2)
- Reproducibility (2)
- Ring resonator (2)
- SBA-15 (2)
- Single particle ICP-MS (2)
- Thermogravimetrie (2)
- Trinkwasser (2)
- Triple isotope fractionation (2)
- Validation (2)
- Wasseraufbereitung (2)
- XANES (2)
- 3D ultrastructural analysis (1)
- 5-Bromouracil (1)
- A4F (1)
- AFM (1)
- Accuracy (1)
- Acrylamide (1)
- Affinity (1)
- Affinitätskonstante (1)
- Airport (1)
- Alteration (1)
- Amplification (1)
- Analytical Chemistry (1)
- Anemia (1)
- Anthropocene (1)
- Antibody (1)
- Antibody-gated indicator delivery (1)
- Archäometrie (1)
- Ashes (1)
- Automatisierung (1)
- Aviation (1)
- Avogadro constant (1)
- BBodSchV (1)
- BPA removal (1)
- Back-side integration (1)
- Bead-based assay (1)
- Bio-apatite (1)
- Bioinformatics (1)
- Biopolymers Probes (1)
- Biosensing (1)
- Biosensors (1)
- Bombs (1)
- Brain (1)
- Breath (1)
- CMC (1)
- CMOS (1)
- CONSENS (1)
- Cadmium (1)
- Carboxyl group (1)
- Cardiovascular (1)
- Cell (1)
- Cellular trafficking (1)
- Certified reference material (1)
- Chemische Prozesskontrolle (1)
- Chemometrie (1)
- Chemometrik (1)
- Chip-Screening (1)
- Cocoa (1)
- Coded Aperture (1)
- Coltan (1)
- Comparability (1)
- Confocal laser scanning microscopy (1)
- Continuous Sensor (1)
- Core-shell particles (1)
- Crossreactivity (1)
- Cryo-soft X-ray tomography (1)
- Cyber-physical Lab (1)
- Cyber-physical system (1)
- Cyclization (1)
- Cytoplasmic remodeling (1)
- DNA origami (1)
- DNA radiation damage (1)
- DNA strand breaks (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Data Analysis (1)
- Dating (1)
- Delta scale (1)
- Delta value (1)
- Dendritic polyglycerol sulfate (1)
- Density separation (1)
- Deuterium (1)
- Deuterium enriched water (1)
- Diagenesis (1)
- Digestion (1)
- Digital twins (1)
- Digitale Transformation (1)
- Duftstoffe (1)
- Dye monomers (1)
- ESMA (1)
- Ecotoxicological Testing (1)
- Elastin-specific contrast agent ESMA (1)
- Elastin-specific molecular agent (1)
- Electrochemical Reactor (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Elutionsverfahren (1)
- Environmental pollutants (1)
- Environmental speciation (1)
- Etofenprox (1)
- Explosives (1)
- Extracellular matrix (1)
- FIB (1)
- FTIR (1)
- Fab Fragment (1)
- Fertilizer (1)
- Fluorine Detection (1)
- Food (1)
- Food analysis (1)
- Fundamental science (1)
- Gadofosveset (1)
- Gadolinium (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Gated hybrid material (1)
- Genetics (1)
- Gerätekommunikation (1)
- Gold (1)
- Gold nanoparticles (1)
- GxP (1)
- HF free Digestion (1)
- HLA (1)
- Hepatocellular carcinoma (1)
- High-Speed (1)
- Hochdurchsatzscreening (1)
- Hot electrons (1)
- Human papillomavirus (1)
- Hybridization (1)
- Hybridoma (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrogenierung (1)
- IC50 (1)
- ICP (1)
- ICP MS (1)
- ICP-AES (1)
- ICP-TOF-MS (1)
- ISO 17025 (1)
- Imaging (1)
- Immunoassays (1)
- In vitro (1)
- Indirect Hard Modelling (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inductively coupled plasma mass spectroscopy (1)
- Industrielle Analytik (1)
- Insecticide (1)
- Instrument Communication (1)
- Interlaboratory Comparison (1)
- Iposomes (1)
- Iron nanoparticles (1)
- Isotope dilution (1)
- Isotope fractionation (1)
- Isotope ratios (1)
- Isotopic shift (1)
- Iterative real-time optimization (1)
- Kilogram (1)
- Kinetics (1)
- Klon A1.1.1 (1)
- Klon EW75C (1)
- Kreuzreaktion (1)
- Kristallolgraphie (1)
- LIBS (1)
- Labor der Zukunft (1)
- Laboratory 4.0 (1)
- Laser ablation-inductively coupled plasma-mass spectrometry (1)
- Laser induced plasma (1)
- Lateral flow assay (1)
- Lateral flow test (1)
- Ligands (1)
- Low-energy electrons (1)
- Low-field NMR Spectroscopy (1)
- Lung cancer (1)
- Lymnaea stagnalis (1)
- MCC (1)
- MDG ICP-ToF-MS (1)
- MR Angiography (1)
- MR imaging (1)
- MS/MS (1)
- MYCN (1)
- Macrophagen (1)
- Measurement space (1)
- Mesoporous particles (1)
- Mesoporous silica (1)
- Metabolomics (1)
- Microbial proteomics (1)
- Microfluidics (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Mixture toxicity (1)
- Modifier adaptation (1)
- Modular Production (1)
- Modulare Produktion (1)
- Mole (1)
- Molecular analysis (1)
- Molecular emission (1)
- Molecular-MRI (1)
- Molecularly imprinted polymers (1)
- Monoclonal Antibody (1)
- Monoterpene (1)
- Moxidectin (1)
- Mud volcanoe fluids (1)
- Multielementanalytik (1)
- Multimodale Analytik (1)
- Multiple-injection sample-standard bracketing (1)
- Multiplexing (1)
- Multivariate analyses (1)
- NMR Spectroscopy (1)
- Nano-carrier (1)
- Nanomaterials (1)
- Nanoparticle characterization (1)
- Nanoparticles (1)
- Natural language processing (1)
- Neural network (1)
- Neural networks (1)
- New ecotoxicological testing tools (1)
- Nitroaromaten (1)
- Nitromoschus (1)
- On-line CE/MC-ICP-MS (1)
- Online NMR Spectroscopy (1)
- Optical detection (1)
- Optical spectrometry (1)
- Optical spectroscopy (1)
- PAH (1)
- PAK (1)
- PIC technology (1)
- Papier (1)
- Pattern recognition receptor (1)
- Peptidbibliotheken (1)
- Peptidsequenzierung (1)
- Peristaltic pumps (1)
- Pesticide (1)
- Phenothrin (1)
- Phospholipids (1)
- Phosphorus (1)
- Photonic Integrated Circuits (1)
- Photonic Sensor (1)
- Photonic biosensor (1)
- Photosensitization (1)
- Physical twin (1)
- Pilot comparison (1)
- Planetary science (1)
- Plant-model mismatch (1)
- Plasma induced luminescence (1)
- Plasma modeling (1)
- Point-Of-Care-Diagnostics (1)
- Pollen (1)
- Polyethylenimine (1)
- Polylactide (1)
- Precision Profile (1)
- Process analytical technology (1)
- Process intelligence (1)
- Process-NMR (1)
- Protein (1)
- Protein nitration (1)
- Protein oligomerization (1)
- Provenance (1)
- Prozessindustrie (1)
- Präzisionsprofil (1)
- Purity (1)
- Pyrethroid (1)
- QNMR (1)
- Quality assurance (1)
- Quantification (1)
- Quantitative NMR Spectroscopy (1)
- Quantitative NMR spectroscopy (1)
- Raman (1)
- Raman-Spektroskopie (1)
- Reactor control (1)
- Real-time Process Monitoring (1)
- Recombinant Antibody (1)
- Recovery (1)
- Reference (1)
- Reference Materials (1)
- Renal disease (1)
- Resonance wavelength shift (1)
- Revision of the SI (1)
- River water sulfate (1)
- SBA-16 (1)
- SC-ICP-ToF-MS (1)
- SERS (1)
- SI (1)
- Sample preparation (1)
- Scale anchor (1)
- Schadstofftransfer (1)
- Sediment (1)
- Sequence dependence (1)
- Silane (1)
- Silicon Photonics (1)
- Single cell analysis (1)
- Single cell-ICP-ToF-MS (1)
- Smart Laboratoy (1)
- Smart sensors (1)
- Smart test laboratories (1)
- Smartphone readout device (1)
- Spectrometer (1)
- Spectrometry (1)
- Strain identification (1)
- Sulfur isotopes (1)
- Sum parameter (1)
- Surface waters (1)
- Surfacewaters (1)
- Sustainable Production (1)
- TED-GC/MS (1)
- TEM (1)
- TGA-FTIR (1)
- TGA-MS (1)
- TNT (1)
- TXRF (1)
- Tau protein (1)
- Terrorism (1)
- Thermal analysis (1)
- Tire Wear (1)
- Transformation products (1)
- Trinitrotoluol (1)
- Type-I pyrethroids (1)
- Ultrasensitive (1)
- Uncertainty (1)
- Urban (1)
- Urine (1)
- VOC (1)
- VRF (1)
- ValidNMR (1)
- Verwertung Bodenmaterial (1)
- Visualization (1)
- Volatile organic compounds (1)
- Wasserzeichen (1)
- Waste (1)
- Water stable isotope analysis (1)
- XRCD method (1)
- ZfP (1)
- electrocatalysis (1)
- magnetic nanocatalysts (1)
- nanostructured (1)
- p-Aminothiophenol (1)
- p-Nitrothiophenol (1)
- qNMR (1)
- silicon (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (85)
- 1.1 Anorganische Spurenanalytik (32)
- 6 Materialchemie (21)
- 1.4 Prozessanalytik (19)
- 6.3 Strukturanalytik (16)
- 1.5 Proteinanalytik (12)
- 1.6 Anorganische Referenzmaterialien (8)
- 4 Material und Umwelt (8)
- 1.7 Organische Spuren- und Lebensmittelanalytik (7)
- 1.9 Chemische und optische Sensorik (6)
Eingeladener Vortrag
- nein (28)
Terrestrial mud volcanoes are unique structures driven by tectonic pressure and fluids from the deep subsurface. These structures are mainly found in active tectonic zones, such as the area near the Los Bajos Fault in Trinidad. Here we report a chemical and microbiological characterization of three mud volcanoes, which included analyses of multiple liquid and solid samples from the mud volcanoes. Our study confirms previous suggestions that at least some of the mud volcano fluids are a mixture of deeper salt-rich water and surficial/precipitation water. No apparent water quality differences were found between sampling sites north and south of a major geological fault line. Microbiological analyses revealed diverse communities, both aerobic and anaerobic, including sulfate reducers, methanogens, carbon dioxide fixing and denitrifying bacteria. Several identified species were halophilic and likely derived from the deeper salt-rich subsurface water, while we also cultivated pathogenic species from the Vibrionaceae, Enterobacteriaceae, Shewanellaceae, and Clostridiaceae. These microorganisms were likely introduced into the mud volcano fluids both from surface water or shallow ground-water, and perhaps to a more minor degree by rain water. The identified pathogens are a major health concern that needs to be addressed.
The presence of microplastic (MP) particles in aquatic environments raised concern About possible enrichment of organic and inorganic pollutants due to their specific surface and chemical properties. In particular the role of metals within this context is still poorly understood. Therefore, the aim of this work was to develop a fully validated acid digestion protocol for metal analysis in different polymers, which is a prerequisite to study such interactions.
The proposed digestion protocol was validated using six different certified reference materials in the microplastic size range consisting of polyethylene, polypropylene, acrylonitrile butadiene styrene and polyvinyl chloride. As ICP-MS/MS enabled time-efficient, sensitive and robust analysis of 56 metals in one measurement, the method was suitable to provide mass fractions for a multitude of other elements beside the certified ones (As, Cd, Cr, Hg, Pb, Sb, Sn and Zn). Three different microwaves, different acid mixtures as well as different temperatures in combination with different hold times were tested for optimization purposes.
With the exception of Cr in acrylonitrile butadiene styrene, recovery rates obtained using the optimized protocol for all six certified reference materials fell within a range from 95.9% ± 2.7% to 112% ± 7%. Subsequent optimization further enhanced both precision and recoveries ranging from 103% ± 5% to 107 ± 4% (U; k = 2 (n = 3)) for all certified metals (incl. Cr) in acrylonitrile butadiene styrene. The results clearly show the analytical challenges that come along with metal analysis in chemically resistant plastics. Addressing specific analysis Tools for different sorption scenarios and processes as well as the underlying kinetics was beyond this study’s scope. However, the future application of the two recommended thoroughly validated total acid digestion protocols as a first step in the direction of harmonization of metal analysis in/on MP will enhance the significance and comparability of the generated data. It will contribute to a better understanding of the role of MP as vector for trace metals in the environment.
An introduction into absolute isotope ratios is given, with application fields ranging from fundamental science to geochronology and forensics. This is followed by a proposal for developing new calibration approaches for obtaining absolute isotope ratios at unrivaled uncertainty levels. This new developments will set the basis for improvements in all scientific fields.
Advances and Applications of Molecular Absorption Spectrometry: from Non-Metals to Isotope Analysis
(2020)
The present work covers two main aspects of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS), an analytical technique for elemental trace analysis.
First, a comprehensive mechanistic study of molecule formation in graphite furnaces is presented, which is a key step into the recovery of analytical signals. For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in HR-CS-GFMAS. A zirconium coating catalyzes the CaF formation, and its structure was investigated. The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. Here a mechanism is proposed, where ZrO2 works as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface.
Second, analytical methods were developed by using HR-CS-MAS as detector for non-metals and isotope analysis. Therefore, the determination of organic absorbable chlorine in water, the quantification of fluorine in consume care products with declared perfluorinated ingredients, and the determination of sulfur content in crude oils were investigated. Finally, the high resolution of the instrumentation allows to measure isotopic shifts with high precision in some observed molecular spectra. Consequently, the molecular spectra of enriched isotopes of boron and magnesium were investigated, establishing so the potential of HR-CS-MAS for the accurate and precise determination of isotopic amount ratios.
Eine umfangreich ausgestaltete Trinkwasseraufbereitung als Multibarrieren-System ist notwendig, wenn das Rohwasser direkt aus Fließgewässern entnommen wird (z. B. für das Mülheimer Verfahren). Eine der Barrieren wird, als gezielte Behandlungs- oder Sicherheitsstufe, oft als Filter mit granulierter Aktivkohle (GAK-Filter) realisiert. Ihre Standzeit kann bei geringer Wasserbelastung (DOC < 2 mg/L), z. B. bei der Landeswasserversorgung Langenau, bis zu 5 Jahre betragen. Bei Rohwasser mit höherem Organikgehalt (DOC > 7 mg/L), wie bei der Nordwasser in Rostock, wird hingegen mindestens alle drei Jahre die GAK in den Filterkolonnen ausgetauscht.
Die Rest-Adsorptionskapazität der GAK kann durch verschiedene Verfahren abgeschätzt werden, ist aber nach wie vor Gegenstand aktueller Forschung. Die weitergehende Charakterisierung der beladenen GAK kann hierbei helfen.
Auf dem Poster sollen erste Ergebnisse zu den in Langenau und Rostock eingesetzten Aktivkohlen präsentiert werden. Hierzu wurden die frischen und nach unterschiedlichen Laufzeiten beladenen GAK untersucht. Die Zusammensetzung der Anorganik und der adsorbierten Organik, welche mittels Zersetzungs¬gasanalyse charakterisiert wurde, zeigt deutliche Unterschiede. Bspw. nimmt der Calcium-Gehalt der GAK in Langenau kontinuierlich zu, wohingegen dieser in den Proben aus Rostock mit zunehmender Laufzeit zurückgeht. Umgekehrt verhält es sich mit der Organik: Die GAK aus Rostock zeigen Hinweise auf biologische Besiedelung, während diese in Langenau trotz längerer Filterlaufzeit auszubleiben scheint.
The goal of this work is to identify the optimal operating input for a lithiation reaction that is performed in a highly innovative pilot scale continuous flow chemical plant in an industrial environment, taking into account the process and safety constraints. The main challenge is to identify the optimum operation in the absence of information about the reaction mechanism and the reaction kinetics. We employ an iterative real-time optimization scheme called modifier adaptation with quadratic approximation (MAWQA) to identify the plant optimum in the presence of plant-model mismatch and measurement noise. A novel NMR PAT-sensor is used to measure the concentration of the reactants and of the product at the reactor outlet. The experiment results demonstrate the capabilities of the iterative optimization using the MAWQA algorithm in driving a complex real plant to an economically optimal operating point in the presence of plant-model mismatch and of process and measurement uncertainties.
Popioły pochodzące z instalacji do spalania komunalnych osadów ściekowych, znajdującej się na terytorium Polski, poddano procesom termochemicznego przekształcania, dzięki czemu otrzymano produkty nawozowe spełniające kryteria dopuszczające je do obrotu jako nawozy mineralne. Ponadto dokonano analizy możliwości wykorzystania popiołów na cele nawozowe zgodnie z obecnie przyjętymi dokumentami strategicznymi i planistycznymi dotyczącymi gospodarki odpadami na poziomie krajowym i europejskim.
Various applications for artificial intelligence in the context of spectroscopy will be presented. in particular, examples from bamline will be featured. After a short introduction to synchrotron radiation, artificial intelligence algorithms for the quantification of X-ray fluorescence measurement are discussed. In the second example, information retrieval by natural language processing is reviewed. As a last example the reconstruction of measurements with the X-ray color camera and coded apertures is presented.
Industry 4.0 is all about interconnectivity, sensor-enhanced process control, and data-driven systems. Process analytical technology (PAT) such as online nuclear magnetic resonance (NMR) spectroscopy is gaining in importance, as it increasingly contributes to automation and digitalization in production. In many cases up to now, however, a classical evaluation of process data and their transformation into knowledge is not possible or not economical due to the insufficiently large datasets available. When developing an automated method applicable in process control, sometimes only the basic data of a limited number of batch tests from typical product and process development campaigns are available. However, these datasets are not large enough for training machine-supported procedures. In this work, to overcome this limitation, a new procedure was developed, which allows physically motivated multiplication of the available reference data in order to obtain a sufficiently large dataset for training machine learning algorithms. The underlying example chemical synthesis was measured and analyzed with both application-relevant low-field NMR and high-field NMR spectroscopy as reference method. Artificial neural networks (ANNs) have the potential to infer valuable process information already from relatively limited input data. However, in order to predict the concentration at complex conditions (many reactants and wide concentration ranges), larger ANNs and, therefore, a larger Training dataset are required. We demonstrate that a moderately complex problem with four reactants can be addressed using ANNs in combination with the presented PAT method (low-field NMR) and with the proposed approach to generate meaningful training data.