Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
Sprache
- Englisch (2)
Referierte Publikation
- ja (2)
Schlagworte
- Cconventional method (1)
- Cement (1)
- Geological material (1)
- Interlaboratory comparison (1)
- Isotope ratios (1)
- MC-ICP-MS (1)
- MC-TIMS (1)
- Measurement uncertainty (1)
- Si isotopes (1)
- Sr isotope analysis (1)
Organisationseinheit der BAM
Bulk enstatite chondrites (EC) and their achondritic counterpart, the aubrites, have the lightest measured Si isotope composition of all rocks in the solar system. Some authors proposed that the enrichment of 28Si in EC metal by equilibrium or kinetic isotope fractionation processes in the solar nebula may have led to the negative δ30/28Si of bulk EC. Because EC are also depleted in refractory elements, loss of a heavy Si component with refractory elements might be an alternative explanation. To further constrain their genesis, we analysed for the first time in situ Si-isotope ratios simultaneously with major- and trace element abundances in silicate and metal phases of Sahara 97072 (EH3) and Indarch (EH4).
An interlaboratory comparison (ILC)was organised to characterise 87Sr/86Sr isotope ratios in geological and industrial reference materials by applying the so-called conventional method for determining 87Sr/86Sr isotope ratios. Four cements (VDZ 100a,VDZ 200a, VDZ 300a, IAG OPC-1), one limestone (IAG CGL ML-3) and one slate (IAG OU-6) reference materials were selected, covering a wide range of naturally occurring Sr isotopic signatures. Thirteen laboratories received aliquots of these six reference materials together with a detailed technical protocol. The consensus values for the six reference materials and their associated measurement uncertainties were obtained by applying a Gaussian, linear mixed effects model fitted to all the measurement results. By combining the consensus values and their uncertainties with an uncertainty contribution for potential heterogeneity, reference values ranging from 0.708134 mol mol-1 to 0.729778 mol mol-1 were obtained with relative expanded uncertainties of ≤ 0.007 %. This study represents an ILC on conventional 87Sr/86Sr isotope ratios, within which metrological principles were considered and the compatibility of measurement results obtained by MC-ICP-MS and by MC-TIMS is demonstrated. The materials characterised in this study can be used as reference materials for validation and quality control purposes and to estimate measurement uncertainties in conventional 87Sr/86Sr isotope ratio measurement.