Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2018 (144) (entfernen)
Dokumenttyp
- Vortrag (83)
- Posterpräsentation (44)
- Zeitschriftenartikel (8)
- Beitrag zu einem Tagungsband (6)
- Sonstiges (2)
- Forschungsdatensatz (1)
Referierte Publikation
- nein (144) (entfernen)
Schlagworte
- Nanoparticle (13)
- ICP-MS (12)
- Laser ablation (11)
- LA-ICP-MS (10)
- Bioimaging (9)
- CONSENS (7)
- Fluorescence (6)
- Prozessanalytik (6)
- BAMline (5)
- Synchrotron (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (110)
- 1.1 Anorganische Spurenanalytik (44)
- 6 Materialchemie (25)
- 1.4 Prozessanalytik (23)
- 1.7 Organische Spuren- und Lebensmittelanalytik (19)
- 1.6 Anorganische Referenzmaterialien (17)
- 6.3 Strukturanalytik (15)
- 1.8 Umweltanalytik (13)
- 8 Zerstörungsfreie Prüfung (11)
- 4 Material und Umwelt (10)
Eingeladener Vortrag
- nein (83)
Following fluorinated drugs by molecular absorption spectrometry – from cancer cells to body fluids
(2018)
Fluorine has been widely introduced into pharmaceutical drugs. Due to the high C-F bond strength, a single atom substitution with fluorine produces drastic desirable and tunable changes in the molecular properties. However, the clinical monitoring of these drugs is not straightforward.
Organofluorine compounds are elusive for a non-targeted analysis; a significant problem in fluorine determination is the lack of suitable detection techniques. Standard atomic absorption and emission spectrometers cannot access fluorine, because their resonance lines lie in the VUV spectral range below 100 nm. In the case of conventional inductively coupled argon plasmas (ICP), the plasma energy is too low to generate a significant population of excited fluorine atoms. Recently, our group introduces high-resolution continuum source absorption spectrometry (HR-CS MAS) as a new way for the indirect monitoring of fluorinated compounds. Main benefits of HR-CS-MAS includes low limits of detection, complete analyte recovery, simple to no sample preparation, and short time analysis.
Small variations in the isotopic composition of some elements have been used as proof of provenance of mineral and biological samples, to describe geological processes, and to estimate a contamination source. Routinely, isotope compositions are measured by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time-consuming and they require a high qualified analyst.
Here, an alternative faster and low-cost optical method for isotope ratio determination is investigated: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X = Li, B, Mg, Ca and Sr have been determined by monitoring the absorption spectra of their in situ generated hydrides (XH) in graphite furnace HR-CS-MAS. For example, the system of two stable isotopes of boron (10B and 11B) was studied via its hydride for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, isotopic composition of samples and reference materials are calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results are metrologically compatible with those reported by mass spectrometric methods. [1] Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shift of their isotopologues can be resolved as shown in Fig.1 b. The extension of this methodology to other elements like Li, Ca and Sr is discussed [2].
References:
[1] C. Abad, S. Florek, H. Becker-Ross, M.-D. Huang, H.-J. Heinrich, S. Recknagel, J. Vogl, N. Jakubowski, U. Panne, Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers, Spectrochim. Acta, Part B, 136 (2017) 116-122.
[2] C. Abad et al., unpublished results, 2018.
We propose an alternative faster and low-cost optical method for isotope analysis: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS).
Stable isotope amount composition of X = Li, B, Mg, Ca and Sr were determined by monitoring the absorption spectra of their in situ generated mono-hydrides (XH) in graphite furnace HR-CS-MAS. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results with an accuracy of 0.15 ‰ are metrologically compatible with those reported by mass spectrometric methods. Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved as shown in Fig.1b. The extension of this methodology to other elements like Li, Ca and Sr is discussed.
Mass spectrometric methods (MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
We propose a lower-cost and faster optical alternative for the analysis of isotope ratios of selected elements: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated mono-hydrides and halide (MH and MX) using graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. The extension of this methodology to other elements like Li, Ca, Cu, and Sr is discussed.
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this peptide hormone plays a major role in the regulation of iron levels in mammals and can reveal important clinical information about several iron-related disorders. However, the development of a reliable assay to quantify hepcidin proved to be problematic and serum hepcidin-25 concentrations determined by various assays differ substantially. Challenges arise in the MS analysis of hepcidin due to the “sticky” character of the peptide and the lack of suitable standards.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) as a reference method candidate to be implemented in routine laboratories. The novelty of the method is the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces. Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions where the use of acidic mobile phases was compared with a novel approach involving solvents at high pH containing 0.1% of ammonia. Both methods were carefully validated and applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with very good correlation of the results.
Carbamazepine (CBZ) and cetirizine (CTZ) are pharmaceutical drugs detected in the aquatic environment. However, the effects to marine invertebrates derived from the combination of these drugs with decreased pH conditions due to ocean acidification are poorly explored. This study investigated the biochemical parameters related to metabolic capacity and oxidative stress response and the transcription of genes related to the mode of action (MoA) of CBZ (1.0 μg/L) and CTZ (0.6 μg/L) in the clam Ruditapes philippinarum chronically exposed (28 days) to control (7.8) and low (7.5) pH conditions. The biochemical parameters applied were: the activity of electron transport system (indicator of organisms’ metabolic capacity); lipid peroxidation content (indicator of cell damage); total glutathione peroxidase activity (indicator of antioxidant defense). The transcription of genes related with drug neurotransmission and metabolism, cell defense and immunity and biomineralization was studied. No metabolic changes and oxidative stress was induced by the exposure to CBZ or CTZ at each pH level, but the transcription of several genes related with the MoA (neurotransmission, immunity and biomineralization) was altered by low pH, drug exposure and the combination of both stressors. In conclusion, it was shown that the interaction of drug exposure and low pH conditions can change bivalves’ sensitivity to drugs or alter drugs toxicity.
Imaging of Eu doped very small iron oxide nanoparticle in atherosclerotic plaques via LA-ICP-MS
(2018)
Atherosclerotic lesions can be visualized by magnetic resonance imaging (MRI) using very small iron oxide nanoparticles (VSOP). VSOP accumulate in atherosclerotic plaques and thus serve as an atherosclerosis probe. The aim of this project was to image the distribution of europium doped VSOP (Eu-VSOP) by laser ablation ICP-MS in histological thin cuts of the aortic root region of ApoE knockout mouse model that is rich in atherosclerotic plaques. In addition, it was investigated whether VSOP accumulation in the plaques correlates with other biomarkers of inflammation for example macrophages and altered endothelium to assess whether it correlates with instability or vulnerability of the plaque regions. For this purpose, antibodies were labeled with various lanthanide elements and correlated with the Eu-VSOP distribution using LA-ICP-MS in a multiplex measurement mode.
Imaging of Eu doped very small iron oxide nanoparticle in atherosclerotic plaques via LA ICP-MS
(2018)
Atherosclerotic lesions can be visualized by magnetic resonance imaging (MRI) using very small iron oxide nanoparticles (VSOP). VSOP accumulate in atherosclerotic plaques and thus serve as an atherosclerosis probe.
The aim of this project was to image the distribution of europium doped VSOP (Eu-VSOP) by laser ablation ICP-MS in histological thin cuts of the aortic root region of ApoE knockout mouse model that is rich in atherosclerotic plaques. In addition, it was investigated whether VSOP accumulation in the plaques correlates with other biomarkers of inflammation for example macrophages and altered endothelium to assess whether it correlates with instability or vulnerability of the plaque regions. For this purpose, antibodies were labeled with various lanthanide elements and correlated with the Eu-VSOP distribution using LA-ICP-MS in a multiplex measurement mode.
A possible correlation of reactive oxygen species (ROS) with endogenous iron or Eu-VSOP can also be detected by LA-ICP-MS. For this purpose, ROS-specific antibodies were also labeled with lanthanides.
Imaging of Eu doped very small iron oxide nanoparticle in atherosclerotic plaques via LA-ICP-MS
(2018)
Atherosclerotic lesions can be visualized by magnetic resonance imaging (MRI) using very small iron oxide nanoparticles (VSOP). VSOP accumulate in atherosclerotic plaques and thus serve as an atherosclerosis probe.
The aim of this project was to image the distribution of europium doped VSOP (Eu-VSOP) by laser ablation ICP-MS in histological thin cuts of the aortic root region of ApoE knockout mouse model that is rich in atherosclerotic plaques. In addition, it was investigated whether VSOP accumulation in the plaques correlates with other biomarkers of inflammation for example macrophages and altered endothelium to assess whether it correlates with instability or vulnerability of the plaque regions. For this purpose, antibodies were labeled with various lanthanide elements and correlated with the Eu-VSOP distribution using LA-ICP-MS in a multiplex measurement mode.
A possible correlation of reactive nitrogen species (RNS) with endogenous iron or Eu-VSOP can also be detected by LA-ICP-MS. For this purpose, RNS-specific antibodies were also labeled with lanthanides.