Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Posterpräsentation (157) (entfernen)
Referierte Publikation
- nein (157)
Schlagworte
- Process Analytical Technology (12)
- Nanoparticle (10)
- ICP-MS (9)
- Bioimaging (8)
- Benchtop NMR (7)
- Benchtop-NMR (7)
- LA-ICP-MS (7)
- Laser ablation (7)
- GD-OES (5)
- HR-CS-GFMAS (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (125)
- 1.1 Anorganische Spurenanalytik (44)
- 6 Materialchemie (27)
- 1.6 Anorganische Referenzmaterialien (22)
- 1.8 Umweltanalytik (22)
- 1.4 Prozessanalytik (21)
- 1.7 Organische Spuren- und Lebensmittelanalytik (21)
- 4 Material und Umwelt (15)
- 6.3 Strukturanalytik (12)
- 6.6 Physik und chemische Analytik der Polymere (11)
SWIR luminescent nanomaterials – key chemical parameters for bright probes for in vivo bioimaging
(2024)
A current challenge for studying physio-pathological phenomena and diseaserelated processes in living organisms with non-invasive optical bioimaging is the development of bright optical reporters that enable deep tissue penetration, a high detection sensitivity, and a high spatial and temporal resolution. The focus of this project are nanomaterials, which absorb and emit in the shortwave infrared (SWIR) between ~900–2500 nm where scattering, absorption, and autofluorescence of the tissue are strongly reduced compared to the visible and NIR.
Oxidative degradation processes of tetrabromobisphenol A (TBBPA), a brominated flame retardant (BFR) in wood, plastics and electronics, were investigated by electrochemistry (EC) coupled online to electrospray ionization mass spectrometry (ESI/MS). Oxidative phase I and II metabolites production was achieved using an electrochemical flow-through cell equipped with a boron doped diamond electrode. Structural elucidation and prediction of oxidative metabolism pathways of TBBPA according to type II ipso-substitution were based on retention time, m/z ratio in negative mode and fragmentation pattern. Using the data obtained through high resolution MS analysis and the identification of single electron transfer (SET) as the initial step of a two-electron oxidation provided the necessary information to propose a mechanism for the electrochemical oxidation of TBBPA. Oxidation reactions involving aromatic hydroxylation and β-scission were the main degradation observed when studying the electrochemical behavior of TBBPA. Computational chemistry experiments using density functional theory (DFT) allowed to identify mono-hydroxylated reaction intermediate and dismissed the mechanism involving two concurrent hydroxylation. TBBPA oxidation products were compared to known metabolites of its biological and environmental degradation confirming the ability of electrochemistry to simulate β-scission reactions.
Faecal contaminants in water are considered serious threats for human health, due to the presence of viruses, bacteria and other harmful microorganisms.1 Urobilin (UB) is a well-known faecal pigment and can be used as a marker for faecal matter in water.2 UB is commonly present in the urine of all mammals as the catabolic end product of bilirubin degradation.2 As the only simple chemical approach to its detection, Schlesinger’s test is usually used to enhance the weak fluorescence of UB in alcoholic media by complexation with Zinc.2, 3 The major limitation of this method is the only weak enhancement of the intrinsically weak UB fluorescence in aqueous media.3 This work presents an approach to introduce different Zn salts for improved fluorescence response, where we found a clear dependence of the fluorescence yield of UB-Zn(II) complexes on the counterion of the salt in water. By employing a combination of fluorescence parameters like transition energy, fluorescence intensity, and fluorescence lifetime, a photophysical understanding of the structure and conformation of the UB-Zn(II) complexes responsible for the fluorescence enhancement in water could be gained. The possibilities of developing a sensitive analytical method based on the acquired understanding are also discussed.
Per- and polyfluoroalkyl substances (PFAS) were classified as a group of highly concerning chemicals over the last decades. Because of the high persistence of PFAS, their previous use led to contamination of the environment and human population. Due to ongoing use and incomplete remediation or destruction methods, the PFAS background in the environment is growing continuously.
The presence of ultrashort PFAS (with ≤3 carbon atoms) in the environment is often overlooked despite their contributions to PFAS levels. These compounds may directly contaminate the environment and arise from degradation of polyfluorinated compounds as well as incomplete PFAS destruction in certain industrial processes. Nonetheless, few approaches for targeted analysis of ultrashort PFASs have been developed, except for trifluoroacetic acid (TFA). Beside liquid (LC-MS/MS), supercritical fluid (SFC-MS/MS), and ion chromatography (IC-MS)-based systems, gas chromatography coupled with mass spectrometry (GC-MS) is a promising method for detection and quantification of ultrashort PFAS.
The goal of this study was to develop a simple headspace GC-MS method for the quantification of ultrashort perfluorocarboxylic acids (PFCAs) and polyfluorinated alcohols (PFOHs) in water samples. In contrast to PFOHs, functionalization of PFCAs was required for quantification. This was done by esterification with methanol at 80 °C, which can be carried out directly in the headspace GC-MS system.
Moreover, several parameters were optimized to achieve a low limit of quantification (LOQ) for the analytes used: i) The ratio of the aqueous solution, methanol, and available gas phase within the analysis vessel, ii) the concentration of additional acid in esterification mixtures of PFCAs, iii) shaking frequency and iv) shaking time before analysis. After optimizing the procedure, we were able to quantify ultrashort PFCAs and PFOHs. Thus, our developed headspace GC-MS method has the potential to be used as an alternative target analysis for ultrashort-chain PFCAs and PFOHs in various water samples (groundwater, wastewater).
Lithium-ion batteries are a key technology for tackling challenges in energy and climate crisis, but up to 30 % are discarded right after production. Quality is closely related to the homogeneity of the used materials and coatings. Fluorine compounds, both in the polymer and from degradation of the electrolyte, are of special interest for the formation and aging of LIBs. Glow-discharge optical emission spectroscopy (GD-OES) emerged as a fast and convenient method for depth-profiling of battery materials. However, fluorine remains a spectroscopic challenge due to a high excitation energy and only few strong emission lines in the UV/Vis spectral range.
We investigated the partial substitution of argon with neon in the plasma gas. The main emission line at 685.603 nm was monitored by both photo multiplier tube (PMT) with Czerny-Turner monochromator at 20 µm slit-size, and charge-coupled device (CCD) with 1200 lines/mm grating. For calibration, we used a set of hot-pressed copper cylinders with varying calcium fluoride amount fraction, ranging from 1.6 % to 4.4 %. Plasma gas mixtures with a mole fraction of 5 %, 10 % and 20 % neon in argon were used. Sensitivity in comparison to pure argon was increased by factor 4, 7 and 14, respectively. In general, PMT detection was more sensitive than CCD. As expected, sputter rates decreased with higher neon content in the plasma gas. Depth-profiling of the cathodes was performed in pulsed mode at constant voltage and pressure, which resulted in stable plasma conditions. We achieve matrix-independent quantitative information on fluorine distribution by correction based on sputter rates.
This advancement in GD-OES provides a more accurate analytical approach for evaluating the homogeneity of lithium-ion battery materials, potentially leading to more sustainable and cost-effective manufacturing processes.
The variation of isotope ratios is increasingly used to unravel natural and technical questions. With new upcoming techniques and research topics in the last two decades, such as material provenance or food authenticity to animal and human migration studies, the number of published isotope data has strongly increased. Here, isotope reference materials are indispensable to enable a reliable method validation or even SI-traceability. The fast development and broad availability of inductively coupled plasma mass spectrometry instrumentation (ICP-MS) also lead to an expansion of the classical research areas and new elements are under investigation. Owing to this large expansion of the field, the production and certification of isotope reference materials for calibration and validation is lagging behind, even for classical applications such as conventional 87Sr/86Sr isotope ratio analysis. To improve this situation, BAM organized an interlaboratory comparison (ILC) comprising of thirteen international laboratories for the characterisation of 87Sr/86Sr isotope ratios in geochemical and industrial reference materials. Six reference materials (four cements and two rocks) were provided as powder requiring extensive sample preparation prior to isotopic measurement. Additional requirements included the use of the conventional method for obtaining 87Sr/86Sr isotope ratios, also known as radiogenic 87Sr/86Sr isotope ratios, and the assessment of the measurement uncertainty. The primary goal was to evaluate potential differences in the application of multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for conventional 87Sr/86Sr isotope ratio determination, with a secondary goal to provide reference values for the 87Sr/86Sr isotope ratios in these potential new reference materials. All reported results are accompanied by an uncertainty statement and are traceable to the conventional method, which will be described in detail within this presentation. Current state-of-the-art statistical models were used to ensure the proper evaluation of the reported results and their associated measurement uncertainties within the frame of this ILC. Combined with results from appropriate homogeneity assessment, reference values for 87Sr/86Sr isotope ratios will be assigned.
Global demand for pigments is expected to increase to around 13.4 million tons per year by 2030, representing approximately $22 billion – 5% of which will be azo pigments as the main organic pigments. Azo pigments, i.e., especially the azo bridge required for them, are almost exclusively produced in technology by the so-called azo coupling reaction in large-scale approaches on the scale of 50–100 cubic meters. Among other things, one of the reasons why large-scale production itself is still essentially discontinuous is the lack of analytical methods for a continuous azo pigment synthesis.
In an azo coupling process, an aromatic amine is diazotized to form the diazonium compound (diazo compound), which then reacts with a coupling component, i.e., "couples". A slight excess of the coupler is desired for the end of the reaction, which stoichiometrically consumes the remaining (harmful) diazo compound, i.e., below 500 ppm. This is carried out with a manual spotting reaction of a fast-binding coupler.
To carry out continuous azo coupling, care must be taken to ensure that the actual coupling reaction proceeds as rapidly as possible, i.e., preferentially, compared with possible side reactions. Reliable measuring methods are thus a decisive criterion for the useful performance of a continuous azo pigment synthesis. An analytical online procedure is difficult due to several limitations at once: solid dispersions extremely limit the range of reproducible analytical procedures. In addition, the appearance of a signal (e.g., excess of a starting material) in the ppm range must be reliably detected against the matrix background.
The back-titration method and benchtop NMR spectroscopy were used to overcome these problems. We present a feasibility study for a suitable process analysis with benchtop NMR spectroscopy on disperse systems for equimolar dosing of the "diazotization" or "coupling" sub-step in azo coupling, which was carried out in cooperation with a chemical company. This could replace tedious manual spotting
The application of compact NMR instruments to continuously flowing samples at higher temperatures or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is typically not designed for compensation of such effects. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements using an optical thermo-graphy setup, a model predictive control was set up to minimize any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, potentially extend the application of compact NMR instruments to flowing samples at higher temperature than the permanent magnet.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
Compact NMR Spectroscopy in the field: A Versatile PAT Tool for Production of Specialty Chemicals
(2023)
Companies of chemical industry find themselves more often in a rapidly changing environment, e.g., due to variability of raw material quality or energy costs and efficiency. Process optimization and new process concepts become more and more important. For example, flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds like exothermic reactions with high heat dissipation.
Highly automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as explosion safety, field communication, and robust evaluation of sensor data. Field studies in modular and conventional production plant setups show promising results gaining process knowledge for further optimization. NMR appeared as preeminent online analytical method and allow using a modular data analysis approach, which can even serve as reliable reference method for further calibration-dependent PAT applications (e.g., NIR or Raman spectroscopy).
Based on experiences from earlier field studies an improved NMR analyzer enclosure setup was developed and built, including the option of a secondary method (e.g., optical spectroscopy). Integrated control systems allow for a flexible implementation based on the available automation infrastructure at the chemical plant or pilot plant setup. In the future, fully integrated and intelligently interconnecting “smart” PAT systems and processes have the potential speed up the setup of production equipment for chemicals and pharmaceuticals and therefore help to reduce the time-to-market.