Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2019 (34) (entfernen)
Dokumenttyp
Referierte Publikation
- ja (34) (entfernen)
Schlagworte
- Thermography (3)
- Composite (2)
- Cracks (2)
- NDT (2)
- Nondestructive testing (2)
- Reinforced concrete (2)
- Zerstörungsfreie Prüfung (2)
- 2D model (1)
- 3D particle analysis (1)
- 3D printing (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (34) (entfernen)
Due to the penetration of harmful chlorides into concrete, e.g. from de-icing salt, damage processes such as chloride-related pitting corrosion can occur if critical values are exceeded. In this study, multiphase materials such as chloride-contaminated concrete are examined in detail. A direct comparison is made by analyzing the spectroscopic information of simultaneously measured atomic and molecular emissions with laser-induced breakdown spectroscopy (LIBS). In addition, the influence on the calibration is examined on the basis of the combined spectral information of both reaction paths of the penetrated chlorides. The calibration models of univariate and multivariate methods were validated using reference samples with wet chemical analysis. The results are applied to a concrete sample of a parking deck, which was also analyzed by potentiometric wet chemistry. In order to account for the heterogeneity of concrete, spatially (200 μm) and spectroscopically (0.1 nm) resolved LIBS measurements were performed using a fully automated laboratory system. Simultaneous measurements with three spectrometers allow the analysis of the emission processes of several elements such as Cl, Ca, O, Si and Mg as well as the newly formed molecules CaO and CaCl. The evaluation of the molecular emission in combination with atomic lines extends the analytical performance, since different concrete phases such as aggregates and cement matrix can be better represented. The measurements were carried out in ambient air and with helium purge gas. The limit of detection (LOD) achieved for a combined evaluation of atomic and molecular emission was determined to be 0.028 wt%.
In various kinds of radiography, deficient transmission imaging may occur due to backlighting inside the detector itself arising from light or radiation scattering. The related intensity mismatches barely disturb the high resolution contrast, but its long range nature results in reduced attenuation levels which are often disregarded. Based on X-ray observations and an empirical formalism, a procedure is developed for a first order correction of detector backlighting. A backlighting factor is modeled as a function of the relative detector coverage by the sample projection. Different cases of sample transmission are regarded at different backlight factors and detector coverage. The additional intensity of backlighting may strongly affect the values of materials’ attenuation up to a few 10%. The presented scenario provides a comfortable procedure for corrections of X-ray or neutron transmission imaging data.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.
Crack detection in metallic samples at high surface temperature, hostile and hazardous environments, etc. is challenging situation in any manufacturing industries. Most of the present NDE methods are suitable only for lower surface temperatures, especially room temperature. In this situation, we need a fast and non-contact NDT method which can be applied even in high sample surface temperature. Laser thermography is one of the techniques having a high potential in non-contact inspection. As a preliminary investigation, in this article, we have studied the potentiality of laser line thermography in crack detection at room temperature. In laser line thermography, a continuous wave (CW) laser is used to generate a laser line, which in turn is used to scan the metal surface. The heat distribution over the sample surface is recorded by an infrared thermal (IR) camera. Two different approaches are reported in this work. Firstly, a stationary laser line source and its interaction with cracks; secondly, moving laser line source scanning over a surface with crack. When the distance between crack centre to laser line centre increases, crack detectability will decrease; and when laser power increases, crack detectability will increase. A dedicated image processing algorithm was developed to improve the detectability of the cracks. To understand the heat transfer phenomenon, a simplified 3D model for laser thermography was developed for the heat distribution during laser heating and was validated with experimental results. Defects were incorporated as a thermally thin resistive layer (TTRL) in numerical modeling, and the effect of TTRL in heat conduction is compared with experimental results.
X-ray reflectivity (XRR) is a powerful and popular scattering technique that can give valuable insight into the growth behavior of thin films. This study Shows how a simple artificial neural network model can be used to determine the thickness, roughness and density of thin films of different organic semiconductors [diindenoperylene, copper(II) phthalocyanine and alpha-sexithiophene] on silica from their XRR data with millisecond computation time and with minimal user input or a priori knowledge. For a large experimental data set of 372 XRR curves, it is shown that a simple fully connected model can provide good results with a mean absolute percentage error of 8–18% when compared with the results obtained by a genetic least mean squares fit using the classical Parratt formalism. Furthermore, current drawbacks and prospects for improvement are discussed.
Historians and librarians are interested in watermarks and mould surface patterns in historic papers, because they represent the “fingerprints” of antique papers. However, these features are usually covered or hidden by printing, writing or other media. Different techniques have been developed to extract the watermarks in the paper while avoiding interference from media on the paper. Beta radiography provides good results, but this method cannot be widely used because of radiation safety regulations and the long exposure times required due to weak isotope sources employed. In this work, two promising methods are compared which can be used to extract digital high-resolution images for paper watermarks and these are electron radiography and low energy X-ray radiography. For electron radiography a “sandwich” of a lead sheet, the paper object, and a film in a dark cassette, is formed and it is exposed at higher X-ray potentials (> 300 kV). The photoelectrons escaping from the lead sheet penetrate the paper and expose the film. After development, the film captures the watermark and mould surface pattern Images for the paper being investigated. These images are then digitized using an X-ray film digitizer. The film employed could potentially be replaced by a special type of imaging plate with a very thin protection layer to directly generate digital Images using computed radiography (CR). For the second method, a low energy X-ray source is used with the specimen paper placed on a digital detector array (DDA). This method directly generates a low energy digital radiography (DR) image. Both methods provide high quality images without interference from the printing media, and provide the potential to generate a “fingerprint”
database for historical papers. There were nevertheless found to be differences in the images obtained using the two methods.
The second method, using a low energy X-ray source, has the potential to be integrated in a portable device with a small footprint incorporating user safety requirements. Differences obtained using the two methods are shown and discussed.
Additively manufactured test specimens made of polyamide 12 (PA 12) by Laser Sintering as well as of acrylonitrile butadiene styrene (ABS) by Fused Layer Modelling, were characterised with active thermography directly after manufacturing and after artificial weathering. For this, two different excitation methods (flash and pulse heating) were used and compared, regarding their suitability for the detection of constructed and imprinted defects inside the test specimens. To increase the quality of the thermograms, data processing methods like thermal signal reconstruction (TSR) and Fourier Transformation after TSR were applied. To further investigate the long-term stability of the additively manufactured test specimens towards environmental stress, like UV radiation, heat, humidity, water contact and frost with active thermography, an artificial weathering test over 2000 hours (~3 months) was applied to the specimens. The monitoring of the changes in the optical properties of the weathered plastics was supplemented by spectral reflectance and UV/VIS spectroscopy.
Digital Volume Correlation (DVC) is a powerful set of techniques used to compute the local shifts of 3D images obtained, for instance, in tomographic experiments. It is utilized to analyze the geometric changes of the investigated object as well as to correct the corresponding image misalignments for further analysis. It can therefore be used to evaluate the local density changes of the same regions of the inspected specimens, which might be shifted between measurements. In recent years, various approaches and corresponding pieces of software were introduced. Accuracies for the computed shift vectors of up to about 1‰of a single voxel size have been reported. These results, however, were based either on synthetic datasets or on an unrealistic setup. In this work, we propose two simple methods to evaluate the accuracy of DVC-techniques using more realistic input data and apply them to several DVC programs. We test these methods on three materials (tuff, sandstone, and concrete) that show different contrast and structural features.
This paper describes the development of a semi-automatic gas measurement device presenting potentially a broad range of applications, noteworthy in the agricultural sector. Non-reversible fluorescent molecular sensors were designed and syn-thesized. Upon, integration into a hydrogel matrix with an optimal ratio of co-solvents, the sensors reacting selectively to ammonia were illuminated by excitation light to produce a concentration-correlated fluorescence emission. An automated mechanical-elec-trical device initiates a given gas mixture and thus simulates con-centrations similar to a threshold value. The aim of this project is to develop a sensor or a low-cost method which can monitor low concentrations of harmful gases and aid in their elimination or regulation in livestock housing, barns or stables.
Mechanochemically synthesized metal–organic Framework material HKUST-1 in combination with acrylonitrile butadiene styrene polymer was used to form a polymer metal–organic framework composite material by a simple extruder.
This composite filament was used for 3D printing. Xray diffraction measurements were used to prove the homogeneous distribution of the metal–organic framework in the polymer on a centimeter scale, whereas X-ray Absorption Edge Tomography using a synchrotron radiation source was able to evaluate the 3D distribution of the metal–organic framework material both in the filament and the resultant printed sample with a resolution of a few lm. Our very first data indicate that, apart from a few clusters having significantly higher Cu concentration, HKUST-1 is distributed homogeneously down to the 100 lm length scale in both polymer bulk materials in the form of clusters with a size of a few lm. Absorption Edge Tomography in combination with data fusion also allows for the calculation of the metal–organic framework amount located on the external polymer surface.