Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Vortrag (127)
Sprache
- Englisch (88)
- Deutsch (38)
- Mehrsprachig (1)
Referierte Publikation
- nein (127)
Schlagworte
- Concrete (39)
- LIBS (23)
- Ultrasound (18)
- NDT (14)
- Beton (11)
- Monitoring (11)
- Ultraschall (10)
- Chloride (8)
- Civil engineering (8)
- Non-destructive testing (8)
Organisationseinheit der BAM
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (127) (entfernen)
Eingeladener Vortrag
- nein (127) (entfernen)
In ultrasonic testing, the time of flight (ToF) of a signal can be used to infer material and structural properties of a test item. In dispersive media, extracting the bulk wave velocity from a received signal is challenging as the waveform changes along its path of propagation. When using signal features such as the first peak or the envelope maximum, the calculated velocity changes with the propagation distance. This does not occur when picking the signal onset. Borrowing from seismology, researchers used the Akaike information criterion (AIC) picker to automatically obtain onset times. In addition to being dependent on arbitrarily set parameters, the AIC picker assumes no prior knowledge of the spectral properties of the signal. This is unnecessary in ultrasonic through-transmission testing, where the signal spectrum is known to differ significantly from noise. In this contribution, a novel parameter-free onset picker is proposed, that is based on a spectral entropy criterion (SEC) to model the signal using the AIC framework. Synthetic and experimental data are used to compare the performance of SEC and AIC pickers, showing an improved accuracy for densely sampled data.
Entwicklung eines luftgekoppelten Ultraschall-Echo-Prüfverfahrens mittels fluidischer Anregung
(2020)
In vielen technischen Bereichen werden Ultraschallverfahren zur zerstörungsfreien Werkstoffprüfung (ZfP) eingesetzt um auf Basis der Signalstärke und der Laufzeit Einbauteile und Beschädigungen zu orten. Luftgekoppelter Ultraschall spielt bisher in kommerziellen Anwendungen vor Allem im Bauwesen eine untergeordnete Rolle, da die Differenz der akustischen Impedanzen von Luft und Festkörpern immense Verluste beim Übergang des Schallsignals hervorruft.
Im Rahmen des Promotionsvorhabens soll die Eignung eines neuartigen Anregungsprinzip untersucht werden, mit dem ein Großteil dieser Verluste vermieden werden soll. Anstelle eines Festkörpers soll mit Hilfe einer fluidischen Düse Druckluft zur Signalerzeugung eingesetzt werden. Die Impedanzverluste zwischen Aktuatormembran und Umgebungsluft entfallen daher.
Die gezielte Schallerzeugung durch einen pulsierenden Freistrahl ist weitgehend unerforscht. Es ist daher notwendig, den so erzeugten Schallpuls in der Interaktion mit dem transienten Strömungsfeld zu untersuchen. Das kompressible Medium Luft und die geringen räumlichen Dimensionen einer hochfrequenten Pulsdüse werfen darüber hinaus einige Herausforderungen hinsichtlich der eingesetzten Messtechnik auf. Hier sollen geeignete Verfahren weiterentwickelt und validiert werden, um die Eignung des fluidisch erzeugten Pulses zu überprüfen.
In diesem Vortrag werden erste Messungen an einem fluidischen Schalter mit denen an einem kommerziellen Luftultraschallprüfkopf verglichen.
Entwicklung eines luftgekoppelten Ultraschall-Echo-Prüfverfahrens mittels fluidischer Anregung
(2019)
In vielen technischen Bereichen werden Ultraschallverfahren zur zerstörungsfreien Werkstoffprüfung eingesetzt. Dabei wird ein Schallpuls von einem Prüfkopf in ein Prüfobjekt eingebracht. Der Puls kann unter anderem durch Membranen oder Piezoelemente erzeugt werden und wird in der Regel durch direkten Kontakt oder über ein Koppelmittel an das Objekt übertragen. Luftgekoppelter Ultraschall spielt in kommerziellen Anwendungen bisher eine untergeordnete Rolle, da die Differenz der akustischen Impedanzen von Luft und Festkörpern immense Verluste beim Übergang des Schallsignals hervorruft.
In diesem Beitrag soll ein neuartiges Anregungsprinzip vorgestellt werden, mit dem ein Großteil dieser Verluste vermieden wird. Anstelle eines Festkörpers soll mit Hilfe einer fluidischen Düse Druckluft zur Signalerzeugung eingesetzt werden. In dieser Düse wird eine selbsterhaltende Strömungsinstabilität erzeugt, die einen Schallpuls von bis zu 100 kHz hervorruft, sodass der Impedanzverlust in die Umgebungsluft entfällt. Da die charakteristische Frequenz eines fluidisch generierten Pulses maßgeblich von der Bauform der Düse und dem anliegenden Druck abhängt, lässt sich mittels einer geeigneten Strömungsregelung ein breiter Frequenzbereich zur Abtastung nutzen. Die so emittierten Pulse werden auf das Prüfobjekt gerichtet und die reflektierten Signale mit einem Laservibrometer an der Oberfläche des Objekts im Echo-Verfahren abgetastet. Von drei signalmindernden Materialübergängen bei gewöhnlichem luftgekoppeltem Ultraschall bleibt in dem hier vorgeschlagenen Messystem lediglich die Grenzfläche von Luft zu Prüfkörper, sodass eine höhere Signalausbeute als bisher erwartet werden kann.
Ultrasonic measurement technology has become indispensable in NDT. In order to reduce measurement time and extend the application to other materials, contactless ultrasound is the subject of many different research groups. Department 8 has been researching successfully in this field for years. A novel approach is based on so-called fluidic devices. These devices can be used to perform binary logic operations with the help of natural flow instabilities. Hence the abbreviated name, Fluidic (FLUID+LogIC). Only a pressure reservoir of the used fluid is required as energy supply. This enables the production of very robust actuators that generate ultrasonic signals in an extremely energy efficient way.
The presentation includes the research results of the ZIM innovation project OsciCheck. The original idea will be presented and its application on different building materials is validated. Beyond this, the possible application areas are much larger and a detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Ein Endlager für radioaktive Abfälle muss auf Dauer vor dem Eindringen von Wasser geschützt werden. Aus diesem Grund errichtete die Bundesgesellschaft für Endlagerung (BGE) ein Verschlussbauwerk als InSitu Versuch im Endlager Morsleben. Hierfür wurde eine bergmännische Auffahrung mit Salzbeton verfüllt.
Zusätzliche in regelmäßigen Abständen eingebaute Trennbleche sollen der Ausbreitung eventueller Risse entgegenwirken.
Das Versuchsobjekt wurde mit Ultraschallmessungen bezüglich der Lage und Orientierung möglicher Risse untersucht. Diese Messungen wurden an der Stirnfläche des Salzbetonkörpers durchgeführt. Für die Datenakquisition fand ein neuartiges Messsystem Anwendung, mit welchem ein seismisches Akquisitionsschema realisiert werden kann. Dieses setzt sich aus mehreren Prüfköpfen zusammen, welche sowohl als Sender als auch als Empfänger fungieren. Somit lassen sich auch größere Sender-Empfänger-Abstände realisieren.
Vor der Bearbeitung der realen Messdaten wurde ein realitätsnahes synthetisches Modell erstellt, mit welchem die Abbildung eines Risses, eines eingebauten Monitoring-Instruments sowie des ersten Trennbleches in einer Tiefe von 8 m untersucht wurden. Die generierten synthetischen Daten wurden nach minimaler Preprozessierung mittels Kirchhoff-Prestack-Tiefenmigration sowie Reverse Time Migration (RTM) in Tiefensektionen umgewandelt. Insbesondere bei der Abbildung steilstehender Reflektoren lieferte die RTM hier ein besseres Ergebnis.
Im Anschluss wurden reale Messdaten in der gleichen Weise bearbeitet. Zusätzlich wurden die Ergebnisse mit denen der Synthetic-Aperture-Focusing-Technique (SAFT) verglichen. Dieses Verfahren ist der Kirchhoff-Migration sehr ähnlich und findet in der zerstörungsfreien Werkstoffprüfung routinemäßig Anwendung. Es stellte sich heraus, dass der RTM Algorithmus in einigen Fällen ein realitätsnäheres Abbild liefert. Die Resultate von Kirchhoff-Migrationund SAFT-Rekonstruktion sind hingegen sehr ähnlich. Alle Verfahren lokalisierten in gleicher Weise Risse in verschiedenen Tiefenlagen, welche hauptsächlich oberflächenparallel orientiert sind. Diese werden auch von Bohrungen bestätigt. Besonders herauszustellen ist die deutliche Abbildung des Trennbleches in großer Tiefe, was bisher noch nicht eindeutig gelungen war.
Ultrasound echo is a widely used NDT technique for determining the internal geometry of structures. Reverse-time migration (RTM) has been recently introduced to NDT applications, as an imaging method for ultrasound data, to overcome some of the limitations (e.g. imaging steeply dipping reflector) experienced by the Synthetic Aperture Focusing Technique (SAFT), the most commonly used imaging algorithm for these measurements.
The standard implementation of RTM also experiences some drawbacks caused by its imaging condition, which is based on the zero-lag of the cross-correlation between source and receiver wavefields and generates high-amplitude low-frequency artifacts. Three alternative imaging conditions, developed for seismic data applications, were tested for their ability to provide better images than the standard cross-correlation: illumination compensation, deconvolution and wavefield decomposition. A polyamide specimen was chosen for the simulation of a synthetic experiment and for real data acquisition. The migrations of both synthetic and real data were performed with the software Madagascar. The illumination imaging condition was able to reduce the low-frequency noise and had a good performance in terms of computing time. The deconvolution improved the resolution in the synthetic tests, but did not showed such benefit for the real experiments. Finally, as for the wavefield decomposition, although it presented some advantages in terms of attenuating the low-frequency noise and some unwanted reflections, it was not able to image the internal structure of the polyamide as well as the cross-correlation did. Suggestions on how to improve the cost-effectiveness of the implementation of the deconvolution and wavefield decomposition were presented, as well as possible investigations that could be carried out in the future, in order to obtain better results with those two imaging conditions.
Monitoring of concrete structures is of utmost importance in maintenance and preservation of infrastructure. As a part of the DFG research group CoDA (Concrete Damage Assessment by Coda Waves), the works within this PhD project aim for identification of damage sensitive parameters extracted from ultrasonic measurements obtained with embedded sensors, the determination of environmental (reversible) influences on the signal and the localisation of damaged areas. The main technique used for the detection of changes in the monitored material is the so-called Coda Wave Interferometry (CWI). It uses the later part of the ultrasonic recording for the detection of small changes in the sensed area and the calculation of a relative velocity change. Using this technique we can show that we are able to detect changes in concrete temperature with ultrasound measurements. This enables temperature correction for ultrasound monitoring with embedded sensors. The crucial point for imaging and localisation with coda waves is the calculation of the so-called sensitivity kernels. We propose the application of numerical wave simulations for the kernel calculations instead of the commonly used diffusivity equation. Using finite-difference wave modelling code from our DFG project partners we are able to calculate those Kernels and first results are shown in this presentation. The major task for the second year will be the development and implementation of the inversion algorithm as well as the preparation of validation experiments.
Ultrasonic coda wave interferometry can detect small changes in scattering materials like concrete. We embedded ultrasonic transducers in the Gänstorbrücke Ulm, a monitored road bridge in Germany, to test the methodology. Since fall 2020, we've been monitoring parts of the bridge and comparing the results to commercial monitoring systems. We calculate signal and volumetric velocity changes using coda waves, and long-term measurements show that the influence of temperature on strains and ultrasound velocity changes can be monitored. Velocity change maps indicate that different parts of the bridge react differently to environmental temperature changes, revealing local material property differences. A load experiment with trucks allows calibration to improve detectability of possibly damaging events. Our work focuses on measurement reliability, potential use of and distinction from temperature effects, combination with complementary sensing systems, and converting measured values to information for damage and life cycle assessment.
Im Zuge der Ist-Zustandserfassung von Stahl- und Spannbetonbauwerken spielt die chemische Analyse von Beton eine zentrale Rolle. Durch den externen Eintrag von schädigenden Substanzen wie Chlorid oder Alkalien aus Tausalzen oder Meerwasser, kann u.U. der Beton und/oder die Stahlbewehrung angegriffen werden. Bei Überschreitung kritischer korrosionsauslösender Chloridgehalte, z.B. bei Stahlbeton 0,4 M.-% (bzw. 0,5 M.-%) und Spannbeton 0,2 M.-% bezogen auf den Zement, erhöht sich das Risiko für eine Chlorid-induzierte Korrosion. Für die Beurteilung eines Instandsetzungsbedarfs und, sofern notwendig, der Erarbeitung eines Instandsetzungskonzeptes muss nach der Rili-SIB1 ein sachkundiger Planer herangezogen werden. Standardmäßig werden für die chemische Analyse Bohrkerne bzw. Bohrmehlproben aus dem zu untersuchenden Bauwerk entnommen und nach aufwendiger Probenvorbereitung nasschemisch analysiert (nach DAfStb Heft 401 oder DIN 14629). Dabei wird der Gesamtchloridgehalt bezogen auf die Einwaage angegeben. Eine Umrechnung auf den Zementgehalt erfolgt i.d.R. durch Schätzwerte. Der Einsatz der laserinduzierten Plasmaspektroskopie (LIBS) wird seit Mitte der 90er Jahren an der Bundesanstalt für Materialforschung und -prüfung erforscht, um den Chloridgehalt durch eine ortsaufgelöste Elementanalyse an einer Betonprobe möglichst genau zu ermitteln. Die zweidimensionale LIBS-Messung mit einer lateralen Auflösung von 100 µm x 100 µm erlaubt die Berücksichtigung der Heterogenität von Beton. Dabei lassen sich die Bindemittelmatrix und die Gesteinskörnung separat betrachten, wodurch sich die Aussagekraft der Ergebnisse und somit die Sicherheit der chemischen Zustandserfassung erhöht. Durch die stetige Weiterentwicklung von Komponenten wie Laser, Spektrometer und analytischer Auswerteroutinen sind mittlerweile automatisierte Systeme für die schnelle LIBS-Analyse auf dem Markt verfügbar. In diesem Vortrag wird der aktuelle Stand der Technik anhand von Praxisbeispielen präsentiert und entscheidende Vorteile gegenüber dem Standardverfahren herausgestellt. Aufgrund der Möglichkeit für eine simultane Multielementanalyse mit LIBS werden weitere Anwendungen, wie z.B. die Ermittlung der Karbonatisierungstiefe, Untersuchungen von Transportprozessen, Chlorideintrag entlang von Rissen oder Untersuchungen von Elementverteilungen im Kontext einer AKR vorgestellt.
The Laser-induced Breakdown Spectroscopy (LIBS) is an useful analytical technique for the chlorine detection in building materials, specifically in the reinforcement concrete. If chlorine exceeds a specific concentration threshold, the result can be pitting corrosion of the reinforcement, which affects the stability and lifetime of building structures like marine constructions, bridges or parking decks. The critical chlorine content based to cement is 0.4 wt.-% based to the cement for reinforced concrete. The ingress of chlorides from sea water or de-icing salt leads to corrosion of the reinforcement.
The chlorine spectral line Cl I at 837.59 nm shows a good performance in helium atmosphere. For measurements without helium we used a electric discharge setup to reheat the Laser-induced plasma with a voltage below 100 V. In this case the reheating shows an increasing chlorine emission in air atmosphere.
This work shows chlorine calibration curves with LIBS in a helium flow and LIBS with electric discharge reheating in air atmosphere. The determination of the limit of detection (LOD) for both setups and the measurement results of a drill core sample with a quantitative chlorine ingress profile will be presented.