Fire Science
Filtern
Erscheinungsjahr
- 2021 (15) (entfernen)
Dokumenttyp
- Vortrag (15) (entfernen)
Sprache
- Englisch (7)
- Deutsch (6)
- Tschechisch (1)
- Mehrsprachig (1)
Referierte Publikation
- nein (15)
Schlagworte
- Behälterversagen (2)
- Bio-based (2)
- Fahrzeugbrand (2)
- Flammschutz (2)
- Großversuch (2)
- Synergy (2)
- TPU (2)
- Abplatzen (1)
- Adjuvant (1)
- Alternative Antriebe (1)
- Aluminium diethylphosphinate (1)
- Aluminum hydroxide (ATH) (1)
- Auswirkungsbetrachtung (1)
- Beton (1)
- Brand (1)
- CFD (1)
- Cable (1)
- Charring Agent (1)
- Dripping Agent (1)
- Durability (1)
- EVA (1)
- Epoxy (1)
- Erneuerbare Energien (1)
- Expandable graphite (1)
- Expandierbarer Graphit (1)
- FVK-Tanks (1)
- Fibre reinforced polymers (1)
- Filler (1)
- Fire Retardant (1)
- Fire test (1)
- Flame retardancy (1)
- Flame retardant (1)
- Flammable lading (1)
- Foam (1)
- Forschungsvorhaben (1)
- Haftklebstoff (1)
- High Performance Concrete (1)
- Insects (1)
- Intumescence (1)
- Klebeband (1)
- Klebtechnik (1)
- LNG (1)
- Liquefied Natural Gas (1)
- Liquid cargo (1)
- Maßstabseffekt (1)
- Messtechnik (1)
- Mode of Action (1)
- Numerische Strömungsmechanik (1)
- PIR foams (1)
- PRV (1)
- Phosphorus flame retardants (1)
- Polyamide 6.6 (1)
- Polyurethan (1)
- Polyurethane (1)
- Pool fire (1)
- Pseudo-synergy (1)
- Pyrolyse (1)
- Renewable fuels (1)
- Safety engineering (1)
- Schaum (1)
- Sicherheitstechnik (1)
- Sloshing affects (1)
- Synergist (1)
- Textile reinforcement (1)
- Unmodellvorschriften (1)
- Vehicle (1)
- Verflüssigtes Erdgas (1)
- Vessel (1)
- Weathering (1)
- Wheel-track interaction (1)
- alternative Antriebe (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (10)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (7)
- 3 Gefahrgutumschließungen; Energiespeicher (3)
- 3.2 Gefahrguttanks und Unfallmechanik (3)
- 2 Prozess- und Anlagensicherheit (2)
- 2.1 Sicherheit von Energieträgern (2)
- 7.3 Brandingenieurwesen (2)
- 7.0 Abteilungsleitung und andere (1)
Eingeladener Vortrag
- nein (15)
Liquid cargo has a significant impact on the interface wheel-track interaction. The sloshing affects the track-railcar's dynamic behavior. The effect is detectable at the track level and at the vehicle. Its characterization requires the combination of different techniques:
Empirical Mode Decomposition (EMD)
Time-Frequency Maps
Sloshing occurred when significant perturbations happened in the railcar:
The railcar entered a curve
Reduction in its travel speed
A railcar with a tank is a clear example of a multibody dynamic system with a nonlinear behavior.
100 mm of PUR-foam give satisfying results in terms of
thermal properties. The non-pressure testing methods gives reliable and repeatable results. Bending modulus of laminates does not change until the first damage occurs. After that, the bending modulus decreases by 50 % but max. stress is still higher than at room temperature.
Beton, als aktuell am meisten verwendeter Baustoff ist nicht brennbar und weist zudem eine sehr geringe Temperaturleitfähigkeit auf. Er eignet sich somit gut für den baulichen Brandschutz. Jedoch neigt Beton im Brandfall zu explosionsartigen Abplatzungen, die zu einer Reduzierung des tragfähigen Querschnitts und sogar zum Versagen des Bauteils führen können. Derzeit werden thermomechanische und thermohydraulische Schädigungsprozesse als die zwei maßgeblichen Ursachen für explosionsartige Abplatzungen angesehen. Diese Schädigungsprozesse sind unter anderem abhängig von der Prüfkörpergröße, dem Wasser-Zement-Wert, der Porosität, der Permeabilität und dem Bewehrungsgrad des Bauteils.
Im Rahmen des Vortrags werden die Forschungsarbeiten zum Maßstabseffekt des Abplatzverhaltens von Betonen bei Brandbeanspruchung präsentiert. Zu diesem Zweck wurden Betonprüfkörper aus sechs verschiedenen Betonmischungen in jeweils drei Prüfkörpergrößen einseitig, ohne Behinderung der thermischen Ausdehnung und ohne externe Last im Tunnelbrandprüfstand der BAM untersucht. Dieser unikale Prüfstand ermöglicht die Brandprüfung unterschiedlicher Prüfkörpergrößen unter vergleichbaren Brandbedingungen sowie die simultane Prüfung mehrerer kleinformatiger Betonprüfkörper. Das präsentierte, laufende Promotionsvorhaben basiert auf einem von der DFG geförderten Forschungsvorhaben und darauf aufbauenden Folgeuntersuchungen.
Die Ergebnisse des DFG-Vorhabens zeigen einen deutlichen Maßstabseffekt mit einer starken Verringerung der Abplatztiefen bei einer Reduzierung der Prüfkörpergröße. Des Weiteren ist das Abplatzverhalten stark von der Betonmischung abhängig. Vor dem Hintergrund der Ressourcenschonung und Kostenreduzierung verfolgen die auf dem DFG-Vorhaben aufbauenden Untersuchungen das Ziel, das Abplatzverhalten großformatiger Betonprüfkörper durch kleinformatige Betonprüfkörper mit angepassten Randbedingungen nachzustellen. Hierfür wurden zwei Betonmischungen des DFG-Vorhabens verwendet. Die Ergebnisse zeigen, dass durch eine Anpassung der Versuchsrandbedingungen dem Maßstabseffekt entgegengewirkt werden kann.
The work aims to assess the textile reinforced concrete at elevated temperatures and applications of additional fire protection as well.
Effective flame retardancy is indispensable in almost all applications of thermally insulating foams in building & construction. The trend to halogen-free materials requires new solutions and proper understanding of structure-activity relationships. Here, we contribute investigations on halogen-free FRs for rigid PIR foams and compare different FRs: isocyanate-reactive vs non-reactive, phosphinate (DOPO) vs phosphonate (BPPO) vs phosphate. It is demonstrated that the chemical structure of the FRs has significant effects on heat emission and char formation.
Products and by-products of the invertebrate and vertebrate farming, respectively, are shown to be promising bio-based flame retardant adjuvants in epoxy thermosets. While the addition of bone meal results in the formation of an inorganic shield, protein-based powders from insects provide an intumescent behavior under forced flaming conditions. Combining the latter with a common flame retardant such as ethylene diamine phosphate, the charring efficiency and self-extinguishing properties can be further enhanced.
Efficient flame retardancy is often achieved only when applying multicomponent systems. Flame retardants are combined or used together with adjuvants or synergists; fibres and fillers contribute to fire properties crucially. Multicomponent systems are discussed in their capacity as general and powerful strategy for achieving and optimizing flame retardant polymeric materials.
Evaluate tank car PRV behavior under realistic fire conditions Subject 1/3 scale tank with full size PRV to engulfing pool fire Initial tests with water lading. Current tests with flammable lading (Ethanol). Document PRV performance with respect to opening pressure, reclosing, and evacuating the tank
Überblick über die Herausforderungen, Anforderungen und Lösungswege für den Flammschutz von Polyurethanwerkstoffen (thermoplastisches und elastomeres Polyurethan (TPU, PUR), PUR Hard- und Weichschäume, PIR, PUR Coatings). Die Werkstoffcharakteristika wie Pyrolyse, effektive Verbrennungswärme, Rückstandsausbeute, Verarbeitungsparameter und kg-Preis definieren die Anforderungen an Flammschutzlösungen. Der Flammschutz ist spezifisch für das Material ausgelegt, aber auch für die verschiedenen Anwendungen (Automobilbau, Schienenfahrzeuge, Bauwesen, Elektrotechnik, usw.), d.h. um spezielle Brandtests zu bestehen. Die Pyrolyse und das Brandverhalten von PUR und PUR-Schäumen sowie der flammgeschützten Varianten wird diskutiert. Die gängigen Flammschutzmittel(-kombinationen) werden zusammengefasst und mit Beispielen belegt.
Im Rahmen des laufenden IGF Projektes 20762 N wurde der Einfluss von Haftklebebändern auf das Brandverhalten von Klebverbunden Untersucht. Dabei wurden sowohl kommerziell verfügbare Klebebänder mit unterschiedlichem Brandverhalten als auch Modellhaftklebebänder mit neuartigen Flammschutzmitteln eingesetzt.
Zunächst wurde das Brandverhalten der Klebebänder adressiert und anschließend der Einfluss jenes Brandverhaltens auf Brandeigenschaften von entsprechend geklebten Verbunden analysiert.
Im Bezug auf die Entflammbarkeit besitzt das Klebeband im Inneren eines Klebverbundes nur einen geringen Einfluss auf das Brandverhalten und die Eigenschaften des Substrates dominieren.
Im sich entwickelnden Brand, hier simuliert durch das Cone Calorimeter, sind deutliche Unterschiede zwischen massivem und geklebten Bauteil zu erkennen. Dabei wirkt die Klebfuge je nach Substrat und Klebebandbeschaffenheit unterschiedlich.
Weitere Untersuchungen zu flammgeschützten Haftklebstoffen sollen erfolgen und somit neue Wege in der Haftklebstoffentwicklung aufzeigen.
Liquefied Natural Gas (LNG) aus regenerativen Quellen, stellt einen potenziellen Kraftstoff für den Schwer- und Fernverkehr des Straßenverkehrs dar. Gegenüber seinen positiven Eigenschaften zu dem in diesem Verkehrssektor häufig verwendeten Kraftstoff Diesel birgt der Kraftstoff aber auch Gefahren für Personen und Bauwerke durch seine sehr niedrige Temperatur bei der Speicherung von ca. -160 °C und seine Explosionsfähigkeit in der Gas-Phase. In der Arbeit wurde sich mit der Gefährdung von Personen und Bauwerken hinsichtlich der von LNG ausgehenden Gefahren in Tunneln auseinandergesetzt.
Tunnel stellen besonders schützenswerte Bauwerke dar, da aus vorhergehenden Störfällen in Tunneln bekannt ist, dass diese mit hohen Personen-, Bauwerks-, und Volkswirtschaftlichen-Schäden einhergehen können.
Untersuchungsschwerpunkt bei der Bewertung von Gefährdungen durch LNG stellte eine Ereigniskaskade bestehend aus Freisetzung, Verdampfung, Stoffausbreitung und Zündung des sich gebildeten explosionsfähigen LNG-Gas/Luft-Gemisches dar. Mit dem Ziel eine solche Ereigniskaskade realitätsnah vorhersagen und zukünftig hierzu Risikoanalysen durchführen zu können wurden innerhalb der Arbeit Parameterstudien sowie Kalibrierungen und Validierungen gegenüber experimentellen Untersuchungen durchgeführt.
Mit den Modellen wurden in der Arbeit exemplarische Fallbeispiele zu Störfällen untersucht. Ergebnisse dieser waren, dass Gefährdungen insbesondere von flüssigem LNG nach dessen Freisetzung und der Verbrennung von LNG-Gas/Luft-Gemischen ausgingen.zeige weniger