Fire Science
Filtern
Dokumenttyp
- Vortrag (36) (entfernen)
Sprache
- Englisch (31)
- Deutsch (4)
- Mehrsprachig (1)
Referierte Publikation
- nein (36)
Schlagworte
- LH2 (5)
- Fire (4)
- MLI (4)
- Tank (4)
- Alternative Antriebe (3)
- Behälterversagen (3)
- Fahrzeugbrand (3)
- LNG (3)
- Railway (3)
- Sloshing (3)
- Alternative Kraftstoffe (2)
- Atmospheric (2)
- Boiling (2)
- Cargo (2)
- Driving (2)
- Liquid cargo (2)
- Messtechnik (2)
- Pool fire (2)
- Vehicle (2)
- Vessels (2)
- Acceleration (1)
- Accidential Fire (1)
- Aerial survey (1)
- Assessing (1)
- Bleve (1)
- Bogie´s centre (1)
- Brandversuche (1)
- Centre plate (1)
- Cold (1)
- Computational (1)
- Containers (1)
- Conveux (1)
- Crygenic (1)
- Demage (1)
- Dust sensor (1)
- Dynamic loads (1)
- Earthquake (1)
- Explosion (1)
- FVK-Tanks (1)
- Filled tank (1)
- Flammable lading (1)
- Forces (1)
- Forschungsvorhaben (1)
- Friction (1)
- GPS Scheme (1)
- Gas Tomography (1)
- Gas flaring (1)
- H2 (1)
- Hazmat (1)
- Infrastrucute (1)
- LPG (1)
- Low-cost (1)
- Mexico (1)
- Non-sloshing (1)
- Oblique testing (1)
- Observing temperatur (1)
- PRV (1)
- Passive Smart Dust (1)
- Perturbation (1)
- Plate friction (1)
- Pressure vessel (1)
- Quasistatic (1)
- RASEM (1)
- Rail (1)
- Rail forces (1)
- Road (1)
- Safe (1)
- Safety (1)
- Scheme (1)
- Sensor network (1)
- Simulating (1)
- Simulation (1)
- Sloshing affects (1)
- Stoßdämpfer (1)
- Subway (1)
- Tankers (1)
- Tanks (1)
- Test rig (1)
- Thermal radiation (1)
- Thermal remote sensing (1)
- Thermohydraulic (1)
- Tilt table (1)
- Transfer (1)
- Transport (1)
- Transportbehälter (1)
- Turns (1)
- Unmodellvorschriften (1)
- Vapour (1)
- Variable friction (1)
- Vessel (1)
- Wasserstoff (1)
- Wheel rail forces (1)
- Wheel-track interaction (1)
- turning (1)
- wheel-forces (1)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (36) (entfernen)
Eingeladener Vortrag
- nein (36)
The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure.
What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank.
The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires.
The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures.
Hydrogen is among the most promising candidates to replace fossil fuels in the energy transition. Hydrogen-powered vehicles are already a reality, and their number is foreseen to increase considerably in the next decade. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) appear to be one of the most effective to ensure high volumetric energy density. A potential loss of integrity of this kind of storage equipment might lead to severe consequences due to high flammability of hydrogen. This might occur, for instance, as a consequence of the exposure to an external source of heat such as a fire following a car accident. Real scale fire test results suggest that the super insulating performance of MLI systems may undergo severe degradation when this is subjected to high temperature, leaving the tank almost unprotected and leading to failure in a relatively short time. Characterizing this kind of accident scenario is crucial to ensure a safe design of storage tanks for Hydrogen-powered vehicles.
This presentation provides an overview of the ongoing research work on modelling MLI LH2 tanks exposed to fire. Lumped and computational fluid dynamic based models are presented, highlighting current gaps. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis case studies.
We are interested in accidental fire impingement of HazMat pressure vessels. Want to develop improved models for predicting time to failure or empty (if PRV present). We are still trying to properly predict pressurization and time to first PRV activation due to liquid temperature stratification for a range of fire scenarios (Full and partial engulfing pool fire, jet fires, with roll over, with TP defects, etc.)
The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire.
Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Its storage requires tanks with Thermal Super Insulations (TSI) to keep the transported fluid cold. The presentation includes 2 main topics of the department.
First TSI has proven itself in various applications over a long time, but not in the land transport sector, where accidents involving collisions, fires, and their combination are to be expected. To analyze fire scenarios a High-Temperature Thermal Vacuum Chamber (HTTVC) was developed that allows the thermal loading of thermal insulation material in a vacuum and measuring the heat flow through the TSI in parallel. Within this chamber, 5 samples were tested regarding 3 different types of MLI, rock wool, and perlites. In the presentation, the results are presented.
Second, the studying of accident scenarios enables the improvement of thermal superinsulation and to find novel insulation concepts. This is necessary for LH2 large-scale storages, for which state-of-the-art solutions are not suitable. Within the presentation, a novel insulation concept will be presented.
Wasserstoff wird als ein potenzieller alternativer Energieträger gesehen, mit dem die für 2050 gesetzten Klimaziele erreicht werden könnten. Der Transport von Wasserstoff ist mittels verschiedener Speichertechniken möglich, von denen der kryogene Transport mit den größten volumetrischen Energiedichten einhergeht. Hierdurch eignen sich diese Speicher besonders für die energieintensiven Verkehrsmittel im Land-, See- und Flugverkehr.
Im Vortrag werden Speichertechniken, Gefahren im Umgang mit kryogenen Gasen sowie bisherige Störfälle dargestellt. Darauf aufbauend wird ein Teil der aktuellen Forschungsarbeit an der BAM vorgestellt, die die Sicherheit dieser Speicher unter außergewöhnlichen Belastungen adressiert.
Liquid cargo has a significant impact on the interface wheel-track interaction. The sloshing affects the track-railcar's dynamic behavior. The effect is detectable at the track level and at the vehicle. Its characterization requires the combination of different techniques:
Empirical Mode Decomposition (EMD)
Time-Frequency Maps
Sloshing occurred when significant perturbations happened in the railcar:
The railcar entered a curve
Reduction in its travel speed
A railcar with a tank is a clear example of a multibody dynamic system with a nonlinear behavior.
100 mm of PUR-foam give satisfying results in terms of
thermal properties. The non-pressure testing methods gives reliable and repeatable results. Bending modulus of laminates does not change until the first damage occurs. After that, the bending modulus decreases by 50 % but max. stress is still higher than at room temperature.
Evaluate tank car PRV behavior under realistic fire conditions Subject 1/3 scale tank with full size PRV to engulfing pool fire Initial tests with water lading. Current tests with flammable lading (Ethanol). Document PRV performance with respect to opening pressure, reclosing, and evacuating the tank
Avoiding road crashes has been the purpose behind many specialized software and hardware systems, involving both active and passive safety principles. Global Positioning technologies were incorporated into the transportation systems with the main purpose of acquiring the position of the vehicle under a continuous basis, for security and economy purposes. However, the GPS data can also be used for assessing the level of safety at which the vehicle is driven. On the basis of the essential data available from commercial GPS devices, in this paper we propose a combined performance measurement to assess the road safety level at which the vehicle is being driven. Such performance measure uses GPS data of the vehicle displacement, including the speed and the acceleration, as well as the course (latitude and longitude coordinates), in an integral driving assessment formulation that can run in real time. Results from the experimental use of this formulation suggest that the level of safety in the driving is time dependent, and that there are risky situations when different factors converge.
Tanks with capacity larger than 700 m3, could be exposed to a resonance excitation when subjected to earthquake motions, regardless of the fill level. Further studies to assess the dynamic forces linked to such resonance and close-to-resonance situations, in a context of a standard overloading situation due to sloshing forces.
Accident safe packages for the transport of spent nuclear fuel and high-level waste shall fulfil international IAEA safety requirements. Compliance is shown by consecutive mechanical and thermal testing. Additional numerical analysis are usually part of the safety evaluation. For damage protection some package designs are equipped with wood filled impact limiters encapsulated by steel sheets.
The safety of these packages is established in compliance with IAEA regulations. Cumulative mechanical and fire tests are conducted to achieve safety standards and to prevent loss of containment. Mechanical reliability is proven by drop tests. Drop testing might cause significant damage of the impact limiter steel sheets and might enable sufficient oxygen supply to the impact limiter during the fire test to ignite the wood filling. The boundary conditions of the fire test are precisely described in the IAEA regulatory. During the test the impact limiter will be subjected to a 30 minutes enduring fire phase. Subsequent to the fire phase any burning of the specimen has to extinguish naturally and no artificial cooling is allowed.
At BAM a large-scale fire test with a real size impact limiter and a wood volume of about 3m³ was conducted to investigate the burning behaviour of wood filled impact limiters in steel sheet encapsulation. Until today burning of such impact limiters is not sufficiently considered in transport package design and more investigation is necessary to explore the consequences of the impacting fire. The objective of the large scale test was to find out whether a self-sustaining smouldering or even a flaming fire inside the impact limiter was initiated and what impact on the cask is resulting.
The amount of energy transferred from the impact limiter into the cask is of particular importance for the safety of heavy weight packages. With the intention of heat flux quantification, a new approach was made and a test bench was designed.