Background Bacterial biofilms are regarded as the most common cause of chronic infections and are often associated with medical devices, such as implants and catheters. Bacteria growing in biofilms produce a protective, extracellular matrix, which enables them to tolerate much higher antimicrobial concentrations than free-living bacteria and survive long enough to acquire antimicrobial resistance. Preventive and therapeutic strategies against biofilm infections in clinical settings commonly involve the application of multiple antimicrobials: biocidal coatings on the biomaterials and systemically administered antibiotics. This frequent practice harbors the risk of the development of cross-resistance via shared resistance mechanisms between antimicrobials used in material coatings and administered antibiotics.
Aim Our goal is to determine how bacteria adapt to antimicrobials during biofilm formation on surfaces coated with antimicrobials, how antimicrobial resistance mutations are acquired and evolve within mature biofilms, and how population dynamics within biofilms affect the transmission of resistance mutations. Specifically, we want to identify antimicrobial-antibiotic-combinations that select for and against antibiotic resistance in biofilms by following the population dynamics of resistant and susceptible strains in competition assays.
Methodology We will grow biofilms of Pseudomonas aeruginosa on glass surfaces with and without antimicrobial coatings and expose them to antibiotics. Then we will track their physiological properties, evolutionary adaptations, and population dynamics. First, we will screen in vitro for combinations of antibiotics and antimicrobials that select for and against antibiotic resistance. Second, effective combinations will be chosen for in-depth investigations during bacterial adhesion and of mature biofilms of resistant and susceptible genotypes. Third, based on the outcome of the screen and the obtained mechanistic understanding we will choose a clinical example in which we study the relevance of our findings in biofilms grown in vivo.
Relevance Studying the biointerfacial interactions between bacterial biofilms and medical devices in terms of population dynamics as well as on single cell level during multidrug selection will help us understand how drug resistance develops and spreads in persistent biofilm infections. Based on our findings we aim to provide clinical recommendations for improved administration of antibiotics/antimicrobials in combination with medical device materials in order to mitigate against biofilm associated antimicrobial resistance.
Synchrotron XPS in the soft-X-ray regime is suitable for the detection of light elements commonly found in biological samples. Various model systems of biofilms have been developed and characterised at synchrotron- and lab-based facilities. By obtaining the chemical composition at various information depths, the vertical distribution of iodine in an artificial biofilm have been determined.
Soil microbes are exposed to different environmental stressors originating from various sources. Biocides used as material preservatives can represent environmental stressors since they are in direct contact with the environment including soil. Microorganism in soils can adapt to stress by different mechanisms; for example, by transferring mobile genetic elements via horizontal gene transfer (HGT). Here, we hypothesize that material preservatives can cause increased frequencies of HGT (i.e. altered community permissiveness) facilitating microbial community adaptation to stress. Furthermore, we hypothesize that soil microbial communities are primed by biocide exposure facilitating the response to different types of stresses. We will incubate soil mesocosms with selected biocides to investigate if these compounds promote HGT of plasmids that carry resistance genes in soil microbial communities. Subsequently, we will prime the soil microbial community with sub-inhibitory concentrations of biocides followed by exposure to toxic biocide concentrations or other types of common environmental stresses including metals, antibiotics, and salt. Using suitable control experiments, a shift in the functional response of the primed as compared to the non-primed community would indicate that biocides prime microbial communities via HGT. Together these results will elucidate the effect of biocides on HGT-mediated adaptation to environmental stressors in soil microbial communities.
Soil microbes are exposed to different environmental stressors originating from various sources. Biocides used as material preservatives can represent environmental stressors since they are in direct contact with the environment including soil. Microorganism in soils can adapt to stress by different mechanisms; for example, by transferring mobile genetic elements via horizontal gene transfer (HGT). Here, we hypothesize that material preservatives can cause increased frequencies of HGT (i.e. altered community permissiveness) facilitating microbial community adaptation to stress. Furthermore, we hypothesize that soil microbial communities are primed by biocide exposure facilitating the response to different types of stresses. We will incubate soil mesocosms with selected biocides to investigate if these compounds promote HGT of plasmids that carry resistance genes in soil microbial communities. Subsequently, we will prime the soil microbial community with sub-inhibitory concentrations of biocides followed by exposure to toxic biocide concentrations or other types of common environmental stresses including metals, antibiotics, and salt. Using suitable control experiments, a shift in the functional response of the primed as compared to the non-primed community would indicate that biocides prime microbial communities via HGT. Together these results will elucidate the effect of biocides on HGT-mediated adaptation to environmental stressors in soil microbial communities.
Soil microbes are exposed to different environmental stressors originating from various sources. Biocides used as material preservatives can represent environmental stressors since they are in direct contact with the environment including soil. Microorganism in soils can adapt to stress by different mechanisms; for example, by the evolution of resistance by de novo mutations or acquisition of resistance genes via horizontal gene transfer (HGT). Here, we hypothesize that material preservatives could enhance the evolution of biocide resistance enabling the potential for cross-resistance to antibiotics. Furthermore, we hypothesize that material preservatives can cause increased frequencies of HGT (i.e. altered community permissiveness) facilitating microbial community adaptation to stress. We will culture soil microorganism with increasing concentrations of selected biocides followed by antibiotic susceptibility determination. Moreover, we will incubate soil mesocosms with selected biocides to investigate if these compounds promote HGT of plasmids that carry resistance genes in soil microbial communities. Together these results will elucidate the potential for the evolution of biocide resistance and cross-resistance to antibiotics as well as the effect of biocides on adaptation to environmental stressors in soil microbial communities.
The particle size distribution is considered the most relevant information for nanoscale property identification and material characterization. The current OECD test guideline on particle size and size distribution (TG 110) is not applicable to ‘nano-sized’ objects. In this project we thus develop a new OECD test guideline for the measurement of the size and size distribution of particles and fibers with at least one dimension in the range of 1 - 1000 nm. A fiber is defined as an object having an aspect ratio of length/diameter l/d >3. The width and length of each fiber should be measured concurrently.
In order to measure the particle size distributions, many techniques are available. 9 methods for particles and 2 methods for fibres have been tested in a prevalidation study and appropriate methods will be compared in an interlaboratory round robin test starting in February 2019.
There is a need for an assessment of the emission properties of volatile organic compounds (VOCs) from consumer products. A method comparison was carried out to evaluate adapted and cost-effective procedures for such items. Smaller and automated emission chambers de-picted similar kinetics compared to a 203 L standard chamber. Toy samples made of PVC (Polyvinyl chloride) emitted more VOCs compared to other tested polymeric products. The emissions from 2 selected samples were studied to allow an evaluation of the resulting room concentration and external exposure of a child. Obtained concentrations were not of concern.
Quality Improvement of VOC chamber emission tests observed for 10 years with round robin tests
(2018)
In Europe, the Construction Products Regulation (CPR, 2011/305/EU) sets basic requirements (BR) on how construction works must be designed and built. BR 3 “hygiene, health and the environment” states low emissions of toxic gases, Volatile Organic Compounds (VOCVOCs), particles, etc. from building materials. Meanwhile, a worldwide network of professional Commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established.
Therefore, comparability of test results must be ensured. The participation in Round Robin Tests (RRTRRTs) is a means to prove a laboratory’s proficiency. Since 2006 BAM offers such proficiency test for emission chamber test every two years.
Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. BAM used different materials over the years. Currently, the best suited reference material is a cured lacquer surface which contained several VOCs added to the liquid lacquer system. The round robin tests 2014, 2016 and 2018 were conducted with such a system.
Compounds like Styrene or n-Alkanes like Decane or Tridecane were tested in many of the proficiency test operated by BAM. Up to now the relative standard deviation of these compounds decrease continuously. Starting with values about 30 % in 2008 we reached values for the mentioned compounds 15 to 20 % now. But even for more polar compounds improved results were received.
Over the years the results of a large group of laboratories detected many compounds with much higher accuracy than at the beginning. So, the comparability between results of different laboratories becomes much better.