4 Material und Umwelt
Filtern
Dokumenttyp
- Vortrag (46)
- Zeitschriftenartikel (35)
- Posterpräsentation (21)
- Beitrag zu einem Tagungsband (12)
- Sonstiges (4)
- Buchkapitel (1)
- Forschungsbericht (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (121) (entfernen)
Schlagworte
- Nano (17)
- OECD (14)
- VOC (9)
- Volatile organic compounds (8)
- Cascade impactor (7)
- Nanomaterial (7)
- Aerosol (6)
- ISO 16000-6 (6)
- TXRF (6)
- Nanomaterials (5)
- Nanoparticle (5)
- Prüfrichtlinie (5)
- Reference material (5)
- Test guideline (5)
- Analytical method (4)
- Construction products (4)
- Corrosion (4)
- EN 16516 (4)
- Emission test chamber (4)
- Gas chromatography (4)
- Guideline (4)
- Standardisation (4)
- Thermal desorption (4)
- UFP (4)
- VVOCs (4)
- Affinity chromatography (3)
- Air quality monitoring (3)
- Antibodies (3)
- Architecture (3)
- BEMMA (3)
- Chemical durability (3)
- Electron microscopy (3)
- FFF-3D-Printer (3)
- Particle size distribution (3)
- Perceived Intensity (3)
- Polyglycerol (3)
- Reference materials (3)
- Size (3)
- Additive Manufacturing (2)
- Additive Manufacturing (AM) (2)
- Aerosol measurements (2)
- Air exchange rate (2)
- Ambient aerosols (2)
- Bauprodukte (2)
- Biofilm (2)
- Biofilms (2)
- CO2 assisted impregnation (2)
- Capsules (2)
- Chamber test (2)
- Chemical analysis (2)
- Chemical characterization (2)
- Consumer products (2)
- Crystallization (2)
- ESEM (2)
- Element mass concentration (2)
- Emission (2)
- Emission chamber (2)
- Emission reference material (2)
- Emissionen (2)
- Emissions (2)
- Environmental simulation (2)
- European standard (2)
- FEM model (2)
- Fluorescence (2)
- Formaldehyde (2)
- Fume (2)
- Geruch (2)
- Glass (2)
- Glutaraldehyde (2)
- ICP-MS (2)
- Indoor air quality (2)
- Iron oxide nanoparticles (2)
- Laser Powder Bed Fusion (L-PBF) (2)
- Loading factor (2)
- Low melting (2)
- MOF (2)
- Material emissions (2)
- Microbiome (2)
- Microplastics (2)
- Museum (2)
- Nano particle (2)
- Nanopartikel (2)
- Particle gas emission (2)
- Particle size (2)
- Particle size distributuion (2)
- Particles (2)
- Particulate emission (2)
- Plume (2)
- Pollutants (2)
- Purification (2)
- Reductive amination (2)
- Reference method (2)
- Round robin test (2)
- Sapphire (2)
- Size distribution (2)
- Size resolved chemical composition (2)
- Spatter (2)
- Test Guideline (2)
- Testguideline (2)
- Thermal extraction (2)
- Time resolved chemical composition (2)
- Total reflection X-ray spectroscopy (2)
- Ultrafine particles (2)
- VOC-emission (2)
- VVOC (2)
- Weathering (2)
- Wooden toys (2)
- 3D Printing (1)
- 3D printer (1)
- 3D printing (1)
- AEROMET II (1)
- AEROMET project (1)
- Accuracy (1)
- Additive manufacturing (1)
- Aerosol element alanysis (1)
- Aerosol element mass concentration (1)
- Aerosol gravimetry (1)
- Aerosol measurement instruments (1)
- Aerosol spectroscopy (1)
- Aerosols (1)
- Aerosolsensor (1)
- Affinity extraction (1)
- Affinity support (1)
- AgBB Bewertung (1)
- Aging test (1)
- Aging tests (1)
- Air analysis (1)
- Air pollution (1)
- Air quality (1)
- Air sampling (1)
- Airborne Particles (1)
- Alkali zinc borate glass (1)
- Aluminium (1)
- Aluminum (1)
- Aluminum oxide (1)
- Ambient air (1)
- Ambient air pollution (1)
- Amino acid analysis (1)
- Analytical chemistry (1)
- Anodization (1)
- Antibody purification (1)
- Aqueous synthesis (1)
- Aromatic amino acid analysis AAAA (1)
- Aromatic amino acid analysis aaaa (1)
- BFR (1)
- BODIPY dye (1)
- BSA (1)
- Beschichtung (1)
- Bio-based insulation (1)
- Bio-weathering (1)
- Bioactive glass (1)
- Bioconjugation (1)
- Bioseparation (1)
- Biosphere (1)
- Black fungi (1)
- Blue Angel ecolabel (1)
- Bodenbelag (1)
- Bovine serum albumin (1)
- Building product (1)
- Building products (1)
- CCQM (1)
- COVID (1)
- CPC calibration (1)
- CRM (1)
- Calibration (1)
- Calibration transfer (1)
- Carrier (1)
- Cellulose ether (1)
- Cerium oxide (1)
- Chamber measurement (1)
- Characterisation (1)
- Characterization (1)
- Chemical composition (1)
- Climate responsive materials (1)
- Cobalt (1)
- Cognitive performance (1)
- Colored glasses (1)
- Comparison (1)
- Conservation (1)
- Construction Products (1)
- Construction product (1)
- Consumer article (1)
- Consumer articles (1)
- Core/shell nanoparticle (1)
- Corona (1)
- Corundum (1)
- Cross-sectioning (1)
- Cubical shape (1)
- Damage repair (1)
- Dendrimer (1)
- Diffusive sampling (1)
- Digitalisation (1)
- Dispay case (1)
- Display case (1)
- Downstream processing (1)
- EDX Analysis (1)
- EN 717-3 (1)
- EU EMPIR (1)
- EU regulations (1)
- Earthen building materials (1)
- Effective uptake rate (1)
- Electronic Lab Notebook (ELN) (1)
- Element analysis (1)
- Elemental aerosol analysis (1)
- Elemental composition (1)
- Emerging Contaminants (1)
- Emission Test Chamber (1)
- Emission Testing (1)
- Emission chamber testing (1)
- Emission chambers (1)
- Emission reference materials (1)
- Emission test chamber procedure (1)
- Emission test method (1)
- Emissions of hazardous gases (1)
- Emisson testing (1)
- Enamel colors (1)
- Enamels (1)
- Environment (1)
- Environmental friendly (1)
- Exposure (1)
- Exposure risk (1)
- Extracellular polymeric substances (1)
- FFF-filament (1)
- FFF-printing (1)
- Faraday cup aerosol electrometer (1)
- Fatigue (1)
- Fiber (1)
- Fibre (1)
- Filament comparison (1)
- Flask method (1)
- Flexible shadow masks (1)
- Fluorometric sensing (1)
- Food (1)
- Forest fires (1)
- Forsterite (1)
- Fungus (1)
- GAeF (1)
- Gas analysis (1)
- Gas sensing (1)
- Geruchsmessung (1)
- Haze Samples (1)
- Heavy metal free (1)
- Historic buildings (1)
- Human plasma (1)
- Hyperbranched polymer (1)
- IEQ (1)
- ISO REMCO (1)
- ISO/TC 229 Nanotechnologies (1)
- Idiopathic environmental intolerance (1)
- Igg (1)
- Immunoglobulins (1)
- Immunoprecipitation (1)
- In-situ Process Monitoring (1)
- In-situ analysis (1)
- Indoor Air Quality (1)
- Indoor Air: Adsorbent performance (1)
- Indoor Products (1)
- Indoor emission (1)
- Inter-comparison (1)
- Inter-lab comparison (1)
- Intercomparison (1)
- Interlaboratory comparison (1)
- Iron oxide (1)
- Knock-out mutant (1)
- LCC (1)
- Lapis lazuli (1)
- Laser Printer (1)
- Laser printer emission (1)
- Layer-by-Layer (1)
- Linker (1)
- Low melting glasses (1)
- Low-tech approach (1)
- Luftgüte (1)
- Market surveillance (1)
- Mask fabrication (1)
- Material emissions testing (1)
- Mechanochemistry (1)
- Medieval glasses (1)
- Melanin Adhesion (1)
- Metallic silver precipitates (1)
- Metals (1)
- Micro-XRF (1)
- Microchamber (1)
- Micropatterning (1)
- Migration (1)
- Mobile anodisation (1)
- Mobile application (1)
- Model aerosols (1)
- Molecular Organic Frameworks (1)
- Monoterpene (1)
- Multiple Displacement Amplification (1)
- Multiple chemical sensitivity (1)
- NDT (1)
- NFDI (1)
- NGS (1)
- Nano CRM (1)
- Nano@BAM (1)
- Nanocarrier (1)
- Nanoparticles (1)
- Nanoplattform (1)
- Nanopowder (1)
- Nickel (1)
- Non-destructive Materials (1)
- Nonspecific binding (NSB) (1)
- Novel sample preparation techniques (1)
- Oddy test (1)
- Odour (1)
- Office machines (1)
- Olivine (1)
- Operating Procedure (1)
- Optical properties (1)
- PGAA (1)
- PIXE (1)
- PM monitors (1)
- PP (1)
- PS (1)
- Particle (1)
- Particle Size (1)
- Particle emission (1)
- Particulate emissions (1)
- Partikel (1)
- Parylene C (1)
- Periodate oxidation (1)
- Phase separation (1)
- Phosphonic acids (1)
- Phosphorous recovery (1)
- Phototrophic bacteria (1)
- Pigment analyses (1)
- Pilot comparison (1)
- Plastic biofilm (1)
- Plastic pollution (1)
- Polyelektrolyt (1)
- Polymer (1)
- Process development (1)
- Process monitoring (1)
- Proficiency testing (1)
- Protein (1)
- Protein a (1)
- Protein hydrolysis (1)
- Protein immobilization (1)
- Protein quantification (1)
- Provenance studies (1)
- QA/QC (1)
- Quality assurance (1)
- Quantum dot (1)
- REACH (1)
- Radon (1)
- Radon exhalation (1)
- Recovery rate (1)
- Reference data (1)
- Reference nanoparticles (1)
- Reference procedures (1)
- Reference samples (1)
- Release kinetics (1)
- Research Data Infrastructure (1)
- Research Data Management (1)
- Robustness validation (1)
- Rround robin test (1)
- SARS (1)
- SAXS (1)
- SDS-PAGE (1)
- SOP (1)
- Safety (1)
- Sample preparation (1)
- Selective quantification (1)
- Self-assembled monolayer (SAM) (1)
- Self-assembled monolayers (SAM) (1)
- Semivolatile organic compounds (1)
- Silver diffusion (1)
- Sintering (1)
- Small angle x-ray scattering (1)
- Solid phase (1)
- Solid-phase extraction (SPE) (1)
- Solvents (1)
- Spectroscopy (1)
- Stained glasses (1)
- Struvite (1)
- Subjective complaints (1)
- Surface chemistry (1)
- Sustainability (1)
- Synthesis (1)
- TEM (1)
- TXRF ambient air aerosol chemical analysis aerosol element composition (1)
- Test method (1)
- Thermal Desorption (1)
- Thermal Extraction (1)
- Thermal properties (1)
- Thermoplastic filaments (1)
- Transmission electron microscopy (1)
- Tyrosine (1)
- UV absorption (1)
- UV protection (1)
- Umweltmessung (1)
- Up-cycling (1)
- VAMAS (1)
- VOC Emission (1)
- VOC Emissionen (1)
- VOC emission (1)
- VOC transfer standards (1)
- Volatile organic compound (1)
- Volatile organic compounds (VOC) (1)
- WKI flask method (1)
- Weathering tests (1)
- X-Ray analysis (1)
- ZIF (1)
- ZIF-8 (1)
- Zeolithe (1)
- Zinc oxide (1)
- natural ventilation (1)
- openBIS (1)
Organisationseinheit der BAM
- 4.2 Material-Mikrobiom Wechselwirkungen (121) (entfernen)
Paper des Monats
- ja (3)
11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers.
Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516
(2018)
For more than 25 years EN 717-1 (Wood-based panels - Determination of formaldehyde re-lease - Part 1: Formaldehyde emission by the chamber method) is the standard for formalde-hyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assess-ment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. To determine a conversion factor four test series were set up with different wooden boards. For a loading of 1 m²/m³ the conversion factor is 1.6. This means that the formaldehyde concentration measured under the conditions of EN 16516 is a factor of 1.6 higher compared to EN 717-1.
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well-characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28 % in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51 %.
Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516
(2018)
For many years EN 717-1 (Wood-based panels - Determination of formaldehyde release - Part 1: Formaldehyde emission by the chamber method) is the standard for formaldehyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assessment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. For the determination of a conversion factor four test series were set up with different wooden boards.
The chemical emissions from products are tested by means of emission test chambers under defined conditions (climate, loading, air change rate). The standard method for the determination of volatile organic compounds (VOC) is the sampling onto Tenax-tubes followed by thermal desorption (TDS) and gas chromatography-mass spectrometry (GC-MS) analysis. The EU-LCI list includes some very volatile organic compounds (VVOC) and some VOC for which there are limitations when using the standard method. For VVOC additional sampling is required using stronger absorbers like Carbotrap or multi-bed adsorption tubes. The analysis of VVOC also requires a different GC oven program and a different column for the separation. For the determination of formaldehyde and other low boiling aldehydes (e.g. acetaldehyde, acetone, propanal, propenal) DNPH-cartridges are used which are extracted with acetonitrile followed by liquid chromatography (HPLC-UV) analysis. The derivatisation of propenal and other unsaturated aldehydes (e.g. 2-butenal) with DNPH might lead to lower findings due to incomplete derivatization and forming of by-products. For a better quantification of acetic acid the use of ion chromatography (IC) is recommended because the analysis of acetic acid with the standard method (TDS) leads to lower findings due to break through during sampling. The use of ion chromatography for the analysis of organic acids requires a third sampling technique. The acids are adsorbed onto silica-gel and extracted with water.
11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers.
Test chamber measurements are an important tool to improve indoor air quality and occupational safety. Test chamber measurements are possible for a wide range of materials, products and technologies. Determination of concerning contaminants is important to ensure good indoor air quality. The detection of concerning contaminants depends on the approriate sampling and analysis.
The presentation gives general information about the European Standard EN 16516 “Construction products – Assessment of release of dangerous substances – Determination of emissions into indoor air”. This test standard was developed based on the mandate M/366 of the European commission and is a horizontal reference method for the determination of volatile organic compounds (VOC) from different classes of construction (building) products. Specific test conditions are to be selected by the product TCs (technical committees) in a way that a product is tested under its intended condition of use.
The test is based on the use of emission test chambers which are operated at constant air change rate and climate (23°C, 50 % r.h.) over 28 days. The standard defines the conditions and requirements for the measurement including loading factor, air change rate, sampling, analysis and calculation of emission rates of the substances. A 30 m³ reference room is described which is used to calculate air concentrations from the determined emission rates.
The standard EN 16516 enables the evaluation of construction products regarding their emissions into indoor air under defined and comparable conditions. The evaluation includes the determination of identified target compounds, non-identified target compounds, volatile carcinogenic compounds and the sum values TVOC, TSVOC and R.
Summary: A screening test for potential emissions of volatile organic compounds (VOC) was run on different thermoplastic filaments used for 3D printing. The method of direct thermal desorption was used to simulate the high temperatures during the 3D printing process and to identify the main compounds emitted from the filaments. A large number of unexpected compounds were detected that might affect the user’s health and have an impact on indoor air chemistry.
Introduction: The use of desktop 3D printers is increasing. Compared to other devices with known emissions, e.g. laser printers, there is still a lack of information on possible emissions of VOC and ultrafine particles during operation and the effect on indoor air quality. Most of the commercially available desktop 3D printers operate with a molten polymer deposition. For this process a solid thermoplastic filament is heated in an extrusion nozzle. Most filaments for desktop 3D printers use either acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) as filament. Alternatives are polyvinyl alcohol (PVA) or polycarbonate (PC).
Method: Eight different thermoplastic filaments for 3D printers were analysed by direct thermal desorption followed by GC-MS identification of the emitted substances. Direct thermal desorption was done by desorbing 5 mg of the feedstock for 1 minute at a temperature of 210°C. This is an average temperature for 3D printing with thermoplastic filaments.
Results and conclusions: The comparison of the 4 different filament groups showed the highest overall emissions from ABS, followed by PLA, PC and PVA. Filament ABS 2 emitted mainly SVOCs and triphenyl phosphate, the latter has the highest emission for a single compound from all evaluated filaments.
Thermoplastic filaments are a new source of VOC emissions due to the high temperatures associated with 3D printing, which can reach up to 270°C. Some of the detected compounds like lactic acid, lactide and bisphenol A have never been described before in the indoor environment. Additionally some of the main substances could not be identified and some others might have the potential to affect the indoor air chemistry.
The appearance of some newly detected compounds raises concerns about potential health effects for the users of 3D printers at home.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, EDS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids were used to introduce functional groups for further conjugations. The common crosslinker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter was oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower non-specific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). A binding capacity of 1.8 mg IgG per gram of corundum powder was achieved. The advantages of corundum include the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, convenient handling, and flexible application.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids are used to introduce functional groups for further conjugations. The common cross-linker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter is oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower nonspecific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by SDS-PAGE. A binding capacity of 1.8 mg IgG per g of corundum powder was achieved. The advantages of corundum are the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, and flexible application.
Nonporous corundum powder was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices.The common crosslinker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter was oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). As a proof of concept, IgG was extracted with protein A from crude human plasma. The advantages of corundum include the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, convenient handling, and flexible application.
The development of traceable new methodologies to quantify elemental air pollutants in particulate matter (PM) supports modernization of methods used in air quality monitoring networks in Europe. In the framework of the EURAMET EMPIR AEROMET II project, the combination of cascade impactor aerosol sampling and total reflection X-ray fluorescence elemental spectroscopy (TXRF) was investigated. This technique requires a traceable calibration based on reference samples. This paper describes a new, simple and effective method to produce such reference samples using flexible, reusable, and low-cost parylene C shadow masks, fabricated by photolithographic steps. These shadow masks can be used to produce reference samples that mimic the Dekati cascade impactor’s deposition patterns by applying as-prepared micro stencils to 30 mm acrylic substrates and evaporating a reference material (Ti) in arrangements of thin circular dots. The highly flexible direct patterning of acrylic discs with reference material, otherwise impossible with conventional photolithography, allows multiple reusing of the same micro stencils. The aspect ratios of the dots could be repeated with an error less than 4 %. A first set of standard reference samples for the 13 stages of the Dekati cascade impactor was produced and preliminary TXRF measurements of the deposited Ti masses were performed. The centricity of the deposition patterns turned out to be an important parameter for the quality of the TXRF results. The parylene mask technology for the production of reference samples turns out to be a promising new approach for the traceable calibration of TXRF spectrometers for the quantification of element concentrations in environmental aerosol samples but, due to its great versatility, it could be used for several other micropatterning applications on conventional and unconventional substrates.
The church of Koszewko (Poland) is a brick building edified in the 15th century built on cobblestone foundations. There are five windows in the sanctuary. Three of them enclose heraldic panels from the Küssow’s family from the 15th century which are surrounded with Goethe glass from the 18th century to complete the windows. The colored heraldic panels are strongly damaged and corroded with massive paint layer losses, glass- and leadbreakages. Those medieval glass fragments have been shortly discovered and are of particular interest for Poland since only few medieval glazing have been conserved.
The damages as well as the glass compositions have been investigated with ESEM/EDX. Two categories of medieval glass compositions have been identified. The blue glass is particularly sensible to corrosion because of his high content in K2O. The colorless and the red glass samples belong to a stable glass type. Due to the thickness of the gel layer, it is easy to see that the degradation is strongly proceeded. The protection of those medieval stained-glass panels is absolute necessary.
The medieval panels have been restored and surrounded from a copper frame. Then they have been fixed on the wood frame in the church. The exterior glazing has been closed with a panel of Goethe glass. The gap between the Goethe- and the medieval glass is about 3 cm. The Goethe glass panel has been stabilized with a film based on polyester to protect the medieval glasses against any damages. In this way, a low cost protective glazing has been installed for a long-term conservation of each medieval stained-glass panels. The climate measurements over the period of one year on the restored windows are in process. The temperature and the relative humidity are recorded in the church interior, in the gap between the original and the Goethe glass and outdoors.
Previous studies have shown that desktop 3D printers (Fused Filament Fabrication) emit high numbers of particulate matter, mainly as ultrafine particles (UFP, particle diameter less than 100 nm). However, the chemical composition of emitted particles has been less extensively investigated. In this study, we therefore focused on the chemical composition of particles emitted from 3D printing. The measurements were conducted in a 1 m³ emission test chamber. Emitted particles were sampled by a 13-stage low-pressure cascade impactor onto aluminum foils and then analyzed by TD-GC/MS to identify their organic compounds. Nine commercial filaments made from basic polymers such as Acrylonitrile Butadiene Styrene (ABS), Acrylonitrile Styrene Acrylate (ASA), Polycarbonate (PC), Poly(methyl methacrylate) (PMMA), Nylon, High Performance Polystyrene (HIPS) and a copper-filled Polylactide (PLA) were investigated. The results show that the organic components of the particles are primarily plastic additives such as plasticizer, antioxidant agents, lubricants, UV-absorbers and UV-stabilizers from the filaments.
The diversity of fused filament fabrication (FFF) filaments continues to grow rapidly as the popularity of FFF-3D desktop printers for the use as home fabrication devices has been greatly increased in the past decade. Potential harmful emissions and associated health risks when operating indoors have induced many emission studies. However, the lack of standardization of measurements impeded an objectifiable comparison of research findings. Therefore, we designed a chamber-based standard method, i.e., the strand printing method (SPM), which provides a standardized printing procedure and quantifies systematically the particle emission released from individual FFF-3D filaments under controlled conditions. Forty-four marketable filament products were tested. The total number of emitted particles (TP) varied by approximately four orders of magnitude (1E9 ≤ TP ≤ 1E13), indicating that origin of polymers, manufacturer-specific additives, and undeclared impurities have a strong influence. Our results suggest that TP characterizes an individual filament product and particle emissions cannot be categorized by the polymer type (e.g., PLA or ABS) alone. The user's choice of a filament product is therefore decisive for the exposure to released particles during operation. Thus, choosing a filament product awarded for low emissions seems to be an easily achievable preemptive measure to prevent health hazards.
The diversity of fused filament fabrication (FFF) filaments continues to grow rapidly as the popularity of FFF-3D desktop printers for the use as home fabrication devices has been greatly increased in the past decade. Potential harmful emissions and associated health risks when operating indoors have induced many emission studies. However, the lack of standardization of measurements impeded an objectifiable comparison of research findings. Therefore, we designed a chamber-based standard method, i.e., the strand printing method (SPM), which provides a standardized printing procedure and quantifies systematically the particle emission released from individual FFF-3D filaments under controlled conditions. Forty-four marketable filament products were tested. The total number of emitted particles (TP) varied by approximately four orders of magnitude (1E9 ≤ TP ≤ 1E13), indicating that origin of polymers, manufacturer-specific additives, and undeclared impurities have a strong influence. Our results suggest that TP characterizes an individual filament product and particle emissions cannot be categorized by the polymer type (e.g., PLA or ABS) alone. The user's choice of a filament product is therefore decisive for the exposure to released particles during operation. Thus, choosing a filament product awarded for low emissions seems to be an easily achievable preemptive measure to prevent health hazards.
Previous studies have shown that desktop 3D printers (Fused Filament Fabrication) emit high numbers of particulate matter, mainly as ultrafine particles (UFP, particle diameter less than 100 nm). However, the chemical composition of emitted particles has been less extensively investigated. In this study, we therefore focused on the chemical composition of particles emitted from 3D printing. The measurements were conducted in a 1 m³ emission test chamber. Emitted particles were sampled by a 13-stage low-pressure cascade impactor onto aluminum foils and then analyzed by TD-GC/MS to identify their organic compounds. Nine commercial filaments made from basic polymers such as Acrylonitrile Butadiene Styrene (ABS), Acrylonitrile Styrene Acrylate (ASA), Polycarbonate (PC), Poly(methyl methacrylate) (PMMA), Nylon, High Performance Polystyrene (HIPS) and a copper-filled Polylactide (PLA) were investigated. The results show that the organic components of the particles are primarily plastic additives such as plasticizer, antioxidant agents, lubricants, UV-absorbers and UV-stabilizers from the filaments.
Cellulose ethers, like methyl cellulose (MC) or hydroxypropyl cellulose (HPC), are widely used in conservation. They also occur as additives and rheology modifiers in various products like dispersions or gels. Do such products release harmful volatile organic compounds (VOC) during their accelerated aging? A mass testing series utilizing the Oddy test of 60 commercial cellulose ethers ranks the products in safe for permanent use (P, no corrosion), only for temporary use (T, slight corrosion), and unsuitable at all (F, heavy corrosion). Results show that 55% of the products passed the test whereas 33% are for temporary use as slight corrosion occurred on at least one metal coupon and only 11% failed the Oddy test. Raman measurements of the corrosion products identified oxides like massicot, litharge, cuprite, and tenorite among carbonates (hydrocerussite, plumbonacrite), and acetates like basic lead acetate, lead acetate trihydrate as well as lead formate as main phases. For example, commercial, industrial Klucel® G (HPC) scored a T rating through slight corrosion on the lead coupon. Basic lead acetate among other phases indicates the presence of acetic acid. Additional measurements of the sample with thermal desorption GC–MS utilizing the BEMMA scheme confirm the high acetic acid outgassing and reveal the presence of a small amount of formaldehyde.
Today glass is broadly used in modern architecture. For indoor applications it is possible to produce decorated glass by using enamel colours and glass painting techniques without any problems. However, this is more limited for applications out of doors. Humidity and environmental pollution attack the surface of the coating and can damage it. There are only a few colours on the market which are resistant towards acids and bases until now. Additionally, most of those colours are opaque. To extend the colour palette, chemically resistant low melting coloured glasses are being developed which are transparent and intensively toned even in thin coating thicknesses. To achieve such an ambitious aim, many parameters have to combine and act in a complex manner. New compositions of lead borosilicate, zinc borosilicate and lead-zinc borosilicate glasses were produced and milled as powder. The thermal properties as well as the environmental stability were analysed. The influence of PbO and ZnO on the thermal properties and the environmental stability were investigated. Evaluation of the fusing results shows that the production and mixture of transparent vitreous enamels for the exterior side of glasses is possible. The tests made it clear that the original materials for making the vitreous enamels must be excellently ground and prepared to achieve a satisfactory result. The method to produce durable vitreous enamels for exterior application also seems to allow the production of glass colours.