Regional standardisation activities and how VAMAS can help in any way to promote activities are reported.
Activities related to organisational updates, government initiatives/priorities (especially related to Materials), details of any strategy documents publicly available, networks within Germany and how we engage are presented.
This presentation was held in an OECD Webinar introducing the newly developed and published OECD TG 125 on particle size and size distribution. The presentation is explaining the structure if the TG 125 and addresses all included methods and methodologies in a short and understandable way for the broader public. The presentation includes sections about nano-particles and nano-fibres.
OECD Prüfrichtlinie 125
(2023)
Diese Präsentation ist eine Einführung in die OECD TG 125 zur Bestimmung der Partikelgrößen von Nanomaterialien. Es wird auf die verchiedenen Probleme der Partikelgrößenbestimmung eingegangen wie z.B. verschiedene Oberflächenschichten, Äquivalenzdurchmesser und Verteilungsfunktionen. Gleichzeitig werden die neuen Begrifflichkeiten eingeführt, die in der TG 125 definiert neu werden.
Die Bestimmung der Nanopartikelgrößen- und -formverteilung nach OECD TG 125 mit einem Differentiellen Mobilitäts Analyse System (DMAS), auch bekannt als SMPS, wird vorgestellt:
- Generelles Messprinzip
- Welchen Durchmesser misst die Methode?
- Welche Partikel kann diese Methode messen?
- Welche Informationen kann diese Methode liefern?
- Wo stößt die Methode an ihre Grenzen?
- Implementierung und Datenauswertung,
- Reporting.
Anschließend wurde eine Q&A-Session für DMAS/SMPS organisiert.
Each year, an immense amount of plastic debris enters marine ecosystems, much of which ends up in the Great Pacific Garbage Patch (GPGP). The plastic fragments are home to a diverse community of microorganisms, and while researchers have gained a better understanding of these marine plastic biofilms, we lack insights into the physiology and genomic potential of the bacteria that colonize them. Examining the lifestyle of plastic colonizers from the GPGP is particularly intriguing, as the high concentration of plastics in this accumulation zone might allow for a microbial adaptation to this unique man-made habitat. A range of pigmentation was observed in 67 isolated strains obtained directly from plastic pieces sampled from the GPGP surface water. Sequence comparison between the cultivated bacterial strains and the 16S rRNA gene amplicon dataset confirmed that most of the cultivates could also be captured through DNA-only methods. Whole genome analysis of four taxonomically diverse representatives revealed multiple carotenoid pathways, including those to produce less common glycosylated carotenoids, like sarcinaxanthin glucoside. Further, we identified a potentially new Rhodobacteraceae species containing a photosynthetic gene cluster (PGC). Absorption analysis confirmed the actual production of the carotenoids and bacteriochlorophyll a. Floating plastics represent a habitat with strong UV-light exposure, making the protection with antioxidant carotenoids as well as the ability to use light as an energy source highly beneficial traits for plastic colonizers. Our findings indicate, that the production of pigments is a common adaption mechanism for plastic-associated bacteria, and that plastic biofilms present a so far overlooked source of rare carotenoids and light-harvesting mechanisms.
Angesichts der zunehmenden Digitalisierung und dem Einsatz datenintensiver Methodiken in der Wissenschaft stehen Forschende vor der Herausforderung, stetig wachsende Datenmengen nachvollziehbar zu dokumentieren, langfristig zu speichern und für Dritte nachnutzbar zu machen. Um diesen Anforderungen gerecht zu werden, bietet sich die Nutzung von Software-Lösungen an, welche Forschungsdatenmanagement mit der digitalen Dokumentation von Laborinventar und Experimenten in elektronischen Laborbüchern (engl. electronic lab notebooks (ELN)) verknüpfen.
The BAM Data Store
(2023)
As a partner in several NFDI consortia, the Bundesanstalt für Materialforschung und -prüfung (BAM, German federal institute for materials science and testing) contributes to research data standardization efforts in various domains of materials science and engineering (MSE). To implement a central research data management (RDM) infrastructure that meets the requirements of MSE groups at BAM, we initiated the Data Store pilot project in 2021. The resulting infrastructure should enable researchers to digitally document research processes and store related data in a standardized and interoperable manner. As a software solution, we chose openBIS, an open-source framework that is increasingly being used for RDM in MSE communities.
The pilot project was conducted for one year with five research groups across different organizational units and MSE disciplines. The main results are presented for the use case “nanoPlattform”. The group registered experimental steps and linked associated instruments and chemicals in the Data Store to ensure full traceability of data related to the synthesis of ~400 nanomaterials. The system also supported researchers in implementing RDM practices in their workflows, e.g., by automating data import and documentation and by integrating infrastructure for data analysis.
Based on the promising results of the pilot phase, we will roll out the Data Store as the central RDM infrastructure of BAM starting in 2023. We further aim to develop openBIS plugins, metadata standards, and RDM workflows to contribute to the openBIS community and to foster RDM in MSE.
Several aspects were explored towards the standardization of a suitable procedure. The use of gaseous standards is necessary and a standard gas mixture containing 60 substances was successfully generated and employed for further investigations. The suitability of different chromatography columns was addressed: The use of PLOT (Porous Layer Open Tubular) columns is well suitable for VVOC analysis. The recoveries of the 60 analytes on several adsorbents and their combinations were determined: A combination of a graphitized carbon black and a carbon molecular sieve showed great results for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. Different options such as purging, the use of a drying system or splitting were investigated for water removal. This contribution will present experimental results supporting the standardization of a method for VVOC analysis.
Die passive Probenahme von VOC (Volatile Organic Compounds) mit Tenax® TA und Thermodesorption GC/MS Analytik ist eine einfache, kosteneffiziente und repräsentative Methode zur Bestimmung der VOC-Konzentrationen in der Innenraumluft. In der Theorie ist die Stoffaufnahme in den Passivsammler nur abhängig vom Diffusionskoeffizienten der Substanz in Luft und der Geometrie des Sammlers (ideale Adsorption). Um sie zu charakterisieren, wird die Aufnahmerate (UR), definiert als Quotient der Massenaufnahme und dem Produkt aus Konzentration und Expositionszeit, verwendet. Viele effektive Aufnahmeraten (UR,eff) unterscheiden sich beträchtlich von idealen (theoretischen) Werten (UR,id). Literaturwerte sind in nationalen und internationalen Normen lediglich für bestimmte Expositionszeiten vorgegeben, während detaillierte Informationen über den zugehörigen Konzentrationsbereich fehlen. Außerdem ist die Anzahl der insgesamt in der Literatur beschriebenen Substanzen begrenzt. Das Ziel der vorgestellten Studie ist es diesen Fundus an Aufnahmeraten zu begutachten und zu prüfen und ihn durch die Bestimmung eigener qualitätsgesicherter Laborwerte zu ergänzen. Die bestimmten Aufnahmeraten werden als akkurat bezüglich ihrer relativen Standardabweichung und Vergleichbarkeit zu Literaturwerten betrachtet und können für Expositionszeiten von 7 Tagen bei Konzentrationen von 50 100 µg/m³ (ca. 100 300 ppm min) empfohlen werden. Die Sieben Tage Aufnahmeraten aus ISO16017 2 und ASTM D6196 sind nicht generell für diesen Zweck geeignet, wie exemplarisch für Benzol gezeigt wurde.
Mehrere Aspekte wurden im Hinblick auf die Standardisierung eines geeigneten Verfahrens für die Analyse sehr flüchtiger organischer Verbindungen (VVOCs) untersucht. Die Verwendung gasförmiger Standards ist notwendig und es wurde ein stabiles Standardgasgemisch aus 60 Substanzen erfolgreich erzeugt und auf Stabilität und Reaktivität überprüft. Die Eignungsuntersuchung verschiedener Chromatographiesäulen ergab, dass PLOT-Säulen (Porous Layer Open Tubular) für die VVOC-Analytik gut geeignet sind. Für die 60 Analyten wurden Wiederfindungsraten auf mehreren Adsorbenzien und deren Kombinationen bestimmt. Dabei zeigte eine Kombination aus einem graphitierten Ruß und einem Kohlenstoff-Molekularsieb hervorragende Ergebnisse für alle Zielkomponenten. Nachteilig an Kohlenstoff-Molekularsieben ist, dass sie Wasser adsorbieren, was die Analyse beeinträchtigen kann. Zur Wasserentfernung wurden verschiedene Optionen wie das Trockenspülen oder der Einsatz eines Trocknungssystems untersucht.
The OECD Working Party on Manufactured Nanomaterials (WPMN) has actively worked towards understanding possible safety issues for manufactured nanomaterials and has contributed significantly to resolving these by developing Test Guidelines, Guidance Documents, Test Reports and other publications with the aim of a safe use of manufactured nanomaterials. To address the specific needs of manufactured nanomaterials, the OECD Test Guideline No. 110 “Particle Size Distribution/Fibre Length and Diameter Distributions” was identified as one of the test guidelines (TGs) to require an update. The current TG 110 (adopted in 1981) is only valid for particles and fibres with sizes above 250 nm. The WPMN prioritised to either update TG 110 to be applicable also to particles at the nanoscale or draft a new nanomaterial specific (TG).
Eventually, it was decided to develop a new TG that covers the size range from 1 nm to 1000 nm, intended for particle size and particle size distribution measurements of nanomaterials. Paragraph 11 provides further justification on the need for such measurements for nanomaterials. This TG overlaps with TG 110 in the size range from 250 nm to 1000 nm. When measuring particulate or fibrous materials, the appropriate TG should be selected depending on the size range of particles tested. In line with TG 110, the new TG for nanomaterials includes separate parts for particles and fibres.
For the part of this TG which addresses particles, several methods applicable to nanomaterials were reviewed and included to take into account developments since 1981 when the TG 110 was adopted. This TG includes the following methods: Atomic Force Microscopy (AFM), Centrifugal Liquid Sedimentation (CLS)/Analytical Ultracentrifugation (AUC), Dynamic Light Scattering (DLS), Differential Mobility Analysis System (DMAS), (Nano)Particle Tracking Analysis (PTA/NTA), Small Angle X-Ray Scattering (SAXS), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM). The method Single Particle Inductively Coupled Plasma Mass Spectrometry (sp-ICP-MS) could not be sufficiently validated within the interlaboratory comparison (ILC) carried out for the different methods in this TG (see also paragraph 6 for further details on the ILC). Applicability of sp-ICP-MS is strongly limited to nanomaterials with high mass values in combination with a sufficiently high particle size. However, the general method ICP-MS is widely used and the sp-mode for the size measurement of specific nanomaterials was successfully performed in ILCs elsewhere. The method is therefore included in the Appendix Part C of this TG, which further details the limitations of sp-ICP-MS.
For measuring the diameter and length of fibres, analysing images captured with electron microscopy is currently the only method available. This TG includes Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM).
To test the validity of this TG, an ILC was performed. Test materials were chosen to reflect a broad range of nanomaterial classes, e.g. metals, metal oxides, polymers and carbon materials. Where possible, well-characterised test materials were used.
Additionally, the test materials were chosen to reflect a broad range of sizes representing the size range 1 nm to 1000 nm. Specifically for fibres, a broad range of aspect ratios was included (length/diameter of 3 to > 50). Some of the test materials used are commercially available and further references are given in the validation report of the ILC. Sample preparation for physical chemical characterisation is critical for all listed methods. Due to the differences between individual nanomaterials and due to the wide range of individual material properties it is impossible to have a generic protocol to obtain the best possible sample preparation for every nanomaterial. Therefore, a generic protocol on sample preparation is not part of this TG. Information on sample preparation is given in the paragraphs 25-29, 33, 34 and 39 for particles and in paragraphs 159) for fibres. Further information on sample preparation of nanomaterials for physical chemical characterisation can be found in the OECD Guidance on Sample Preparation and Dosimetry for the Safety Testing of Manufactured Nanomaterials and elsewhere.
Data for the publication "The role of extracellular polymeric substances of fungal biofilms in mineral attachment and weathering" (https://doi.org/10.1038/s41529-022-00253-1). It includes:
- The Summary of the EPS concentration, EPS sugar components and EPS linkages.
- The Summary of the XPS analysis of freeze-dried biofilm samples of all strains.
- The Summary of the pH, Mg, SI and Fe concentration, biomass and olivine dissolution rate for each time point of all dissolution experiments.
Axial passive sampling of VOCs with Tenax® TA and thermal desorption GC-MS analysis is an accepted alternative to active sampling in occupational hygiene. In theory, the uptake into the passive sampler is only dependent on the diffusion coefficient of the analyte in air and the geometry of the sampler (ideal adsorption). For characterization, the uptake rate (UR) is used defined as the ratio of the mass adsorbed and the product of ambient concentration and exposure time. Various reported effective uptake rates (UR,eff) differ to an increasing degree from ideal values (UR,id) with increasing exposure doses (denominator of the given definition of UR), (Tolnai, 2001). In national and international standards, uptake rates are essentially sorted by the applicable exposure time, while detailed information about the corresponding concentration range is lacking. Moreover, especially for long exposure periods as applied in indoor air monitoring, the number of itemized substances is limited. Therefore it is the aim of this contribution to review and expand uptake rate data by comparison of literature and own laboratory values of assured quality. Passive samplers were exposed to nine single compound atmospheres of known concentrations for seven days. Concentrations were checked twice a day via active sampling.The determined uptake rates are considered accurate in terms of RSD and comparability to literature values and can be recommended for exposure times of seven days at 50 – 100 μg m-3 (approximately 100 – 300 ppm min). Seven-day uptake rates in ISO16017-2 and ASTM D6196 are not generally suited for this purpose, as has been exemplarily shown for benzene. Thus, it is crucial for optimization of the method to produce more reliable uptake rate data, including specific information about applicable exposure times and concentrations, which will be promoted in the course of this ongoing study.
Since 1997, the Committee for Health-related Evaluation of Building Products (AgBB) has been developing the basis for building regulations for protection against indoor health risks that may arise when building products are used. In 2009, the AgBB decided to include relevant VVOCs in the assessment procedure. The ISO 16000-6 (2021) states that the use of the thermal desorption gas chromatography technique is appropriate for VVOCs, if adaptations are considered. However, a suitable method for the trustworthy quantification of VVOC emissions from building products and in the indoor air is still missing.
This webinar will present the results of a research project on the development of a procedure for VVOC analysis:
• identification of the gaps towards standardization
• investigations on gas standards and the suitability of chromatography columns
• investigations on sorbent combinations and water management
• validation of the method and screening of VVOC emissions from building products.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids are used to introduce functional groups for further conjugations. The common cross-linker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter is oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower nonspecific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by SDS-PAGE. A binding capacity of 1.8 mg IgG per g of corundum powder was achieved. The advantages of corundum are the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, and flexible application.
Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt.
Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes.
11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers.