4 Material und Umwelt
Filtern
Erscheinungsjahr
- 2023 (19) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (7)
- Vortrag (5)
- Buchkapitel (4)
- Beitrag zu einem Tagungsband (2)
- Posterpräsentation (1)
Sprache
- Englisch (19) (entfernen)
Schlagworte
- Indoor air quality (4)
- Ink analyses (3)
- VOC (3)
- Dead Sea Scrolls (2)
- Middle Ages (2)
- Odour (2)
- Perceived intensity (2)
- Thermal desorption (2)
- Ultrafine particles (2)
- 3D printing (1)
Organisationseinheit der BAM
- 4.5 Kunst- und Kulturgutanalyse (19) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (5)
On the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method
(2023)
A standardised method for the analysis of very volatile organic compounds (VVOCs) in indoor air is still missing. This study evaluates the use of Carbograph 5TD as an adsorbent for 60 compounds (47 VVOCs + 13 VOCs) by comparing their recoveries with different spiking modes. The influence of the spiking of the tubes in dry nitrogen, humidified air or along the whole flushing duration mimicking real sampling was investigated. 49 substances (36 VVOCs from C1 to C6) had recoveries over 70% on the adsorbent in humidified air and were validated. The linearity of the calibration curves was verified for every spiking mode and the limits of detection (LOD) and quantification (LOQ) were determined. The LOQs were lower than the existing indoor air guideline values. The robustness of the method was considered by studying the influence of the sampling volume, the sampling flow rate, the humidity level and the storage of the tubes. In general, the most volatile or polar substances were the less robust ones. The combined measurement uncertainty was calculated and lies below 35% for a vast majority of the substances. An example of an emission chamber test using polyurethane foam is shown: Carbograph 5TD performs much better than Tenax® TA for VVOCs and emissions from n-butane were quantified with combined measurement uncertainty.
Round robin tests of odour and VOC emissions from building products – What have we learned so far?
(2023)
Emission testing of volatile organic compounds (VOC) and odour from materials and products is commonly based on emission test chamber measurements. These measurements are often the basis of mandatory or voluntary labelling procedures. To ensure the comparability of results from different testing laboratories their performance must be verified. For this purpose, round robin tests (RRTs) are conducted. Bundesanstalt für Materialforschung und - prüfung (BAM) offers such a RRT every two years using well characterised test materials with defined VOC emissions. In addition to the VOC quantification, the evaluation of odour is also implemented in the round robin tests. At the beginning, only perceived intensity (PI) was tested but over the years also the acceptance evaluation was considered. In principle, the results of PI and acceptance evaluation are comparable. The advantage of PI is the lower number of panel members necessary for one evaluation.
VOC-emissions and their odours from building products and furnishings present indoors should not have an impact on personal well-being or health. Odours can be measured by applying the standard ISO 16000-28. Indoor air determination of odour emissions from building products using test chambers. One of the described procedures is the assessment of perceived intensity using a comparative scale by a group of panellists. In this paper, the perceived intensity sampling procedure and its evaluation method are investigated and shown to need improvement. New technical developments in the methodology used to increase the reproducibility of measurement results are discussed. Since odour tests are used for labelling, they have a major influence on the assessment of construction products, similar to the procedure of the German Committee for Health Evaluation of Building Products (AgBB). In the original ISO standard, the evaluation is typically performed using a sampling container separated from the emission chamber. For a better sample presentation, an adapter was developed to connect the emission test chamber to the evaluation funnel and thus enable an odour assessment which is comparable to a direct measurement. The investigations show that losses of odourous substances can be greatly reduced, which is very desirable when seeking to obtain reliable results in odour measurement. Another experimental series was carried out to reduce the measurement effort in the evaluation of perceived intensity. Application of the developed greater than or less than/equal to. query could be helpful here. The results show that the query mostly leads to the same result as the evaluation of the perceived intensity using the method according to the standard but is much easier to perform. Overall, the results can contribute to improving the acceptance of the evaluation of perceived intensity using ISO 16000-28 and to determining odours from building materials increasingly more precisely.
In this article, we present two Coptic papyri, P 11934 and P 11935 from the Berlin collection excavated in Ashmunein (ancient Hermopolis) by Otto Rubensohn in 1906. We employ a multi-disciplinary approach that takes into account both their materiality – writing support as well as ink – and their content, as has become ‘best practice’. 1 Material aspects of written documents have traditionally been the purview of papyrologists. Recently developed methods of scientific analysis generate sets of archaeometric data with the potential to improve understanding of the materiality of ancient document production, as well as to yield new evidence for genuine papyrological research questions. To achieve this, a large corpus of comparative data needs to be built. Our contribution offers a first step in this direction. We aim at presenting the papyri, which were selected because of the ink corrosion during conservation work at the Berlin collection, in a format that is exhaustive both for material and textual aspects. The inks from both papyri were analysed using a combination of techniques, contributing to our better understanding of the development of ink technology in Late Antiquity.
Fused filament fabrication (FFF) is a material extrusion-based technique often used in desktop 3D printers. Polymeric filaments are melted and are extruded through a heated nozzle to form a 3D object in layers. The extruder temperature is therefore a key parameter for a successful print job but also one of the main emission driving factors as harmful pollutants (e.g., ultrafine particles) are formed by thermal polymer degradation. The awareness of potential health risks has increased the number of emission studies in the past years. However, studies usually refer their calculated emission data to the printer set extruder temperature for comparison purposes. In this study, we used a thermocouple and an infrared camera to measure the actual extruder temperature and found significant temperature deviations to the displayed set temperature among printer models. Our result shows that printing the same filament feedstocks with three different printer models and with identical printer set temperature resulted in a variation in particle emission of around two orders of magnitude. A temperature adjustment has reduced the variation to approx. one order of magnitude. Thus, it is necessary to refer the measured emission data to the actual extruder temperature as it poses a more accurate comparison parameter for evaluation of the indoor air quality in user scenarios or for health risk assessments.
In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. Different VOC combinations may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use materials proven to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability and metrological traceability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable reference materials. The emission test chamber procedure according to EN 16516 comprises several steps from sample preparation to sampling of test chamber air and chromatographic analysis. Quality assurance and quality control (QA/QC) must therefore be ensured. Currently, there is a lack of suitable reference products containing components relevant for the health-related evaluation of building products.
The EU-funded EMPIR project 20NRM04 MetrIAQ (Metrology for the determination of emissions of dangerous substances from building materials into indoor air) aims to develop 1) gaseous primary reference materials (gPRM), which are used for the certification of gaseous (certified) reference materials (gCRM) and 2) emission reference materials (ERM).
Most commercial gas standards of indoor-relevant compounds are not certified due to the lack of primary reference materials to which the project aims to contribute. The gPRM under development is a gas-phase standard containing trace levels of VOCs in nitrogen or air from the check standard according to EN 16516 (n-hexane, methyl isobutyl ketone, toluene, butyl acetate, cyclohexanone, o-xylene, phenol, 1,3,5-trimethylbenzene) with a target uncertainty of 5 %. The gPRM can be sampled into sorbent tubes to obtain transfer standards in the form of gCRM.
The well characterised ERM represents a sample of a test specimen, e.g. building material, that is loaded into the emission test chamber for a period of several days and is used to evaluate the whole emission test chamber procedure. It shall have a reproducible and temporally constant compound release of less than 10 % variability over 14 days. Different approaches for retarded VOC release, such as the encapsulation of pure compounds and the impregnation of porous materials, are being tested to reach this aim. Furthermore, the design of the ERM is accompanied by the development of a numerical model for the prediction of the emissions for each of the target VOCs. The current progress of the work on both materials will be presented.
In 2005, a team of Polish archaeologists discovered three Coptic codices, two on papyrus and one on parchment, in the rubbish dump of a hermitage at Sheik Abd el-Gurna, Egypt. While the parchment codex and the remains of the bindings of the papyrus ones have been conserved, the text blocks of the papyrus codices were opened and disassembled and after being disinfected remained untouched for nearly 15 years, until the current project started. Currently, all three books are stored in the collection of the Coptic Museum in Cairo. Our team undertook the conservation of and archaeometric research on the papyrus codices. The first of the books contains the Canons of Pseudo-Basil, while the second is an Encomium of St. Pisenthios. Both codices have been palaeographically dated to the seventh-eighth centuries CE. In this paper, we describe our project and present the results of the work carried out on the Canons of Pseudo-Basil. Our work involved photography in transmitted light, measurements of the thickness of the papyrus leaves, and digital microscopy under three-light illumination. These measurements allowed us to determine the types of the inks and characterize the papyrus writing substrate. For conservation, we used a novel method developed in the Egyptian Museum in Berlin that comprises suspending papyrus folios on a translucent, extremely thin Japanese paper inside glass frames without the use of adhesives.In 2005, a team of Polish archaeologists discovered three Coptic codices, two on papyrus and one on parchment, in the rubbish dump of a hermitage at Sheik Abd el-Gurna, Egypt. While the parchment codex and the remains of the bindings of the papyrus ones have been conserved, the text blocks of the papyrus codices were opened and disassembled and after being disinfected remained untouched for nearly 15 years, until the current project started. Currently, all three books are stored in the collection of the Coptic Museum in Cairo. Our team undertook the conservation of and archaeometric research on the papyrus codices. The first of the books contains the Canons of Pseudo-Basil, while the second is an Encomium of St. Pisenthios. Both codices have been palaeographically dated to the seventh-eighth centuries CE. In this paper, we describe our project and present the results of the work carried out on the Canons of Pseudo-Basil. Our work involved photography in transmitted light, measurements of the thickness of the papyrus leaves, and digital microscopy under three-light illumination. These measurements allowed us to determine the types of the inks and characterize the papyrus writing substrate. For conservation, we used a novel method developed in the Egyptian Museum in Berlin that comprises suspending papyrus folios on a translucent, extremely thin Japanese paper inside glass frames without the use of adhesives.
Colours on East Asian Maps
(2023)
Maps and colours have a close connection. Drawn or printed in black on white, subsequently added colours enhance maps with additional information. Colours were not just there to improve maps aesthetically, but they regulated how they were read and thus reinforced their meanings, significances and ideas. Colour is an important key to a more precise understanding of the map’s purposes and uses; moreover, colours are also an important aspect of a map’s materiality. The material scientific analysis makes it possible to find out more about the making of colours and the process of colouring maps. By skillfully deploying colours, map colourists were able to create mimetic representations of nature or codify information in an abstract form. The use of colours involved many considerations as to the materials. ‘Reading’ colours in this way gives a glimpse into the social lives of mapmakers as well as map users and reveals the complexity of the historical and social context in which maps were produced and how the maps were actually made. Within the scope of the three-year joint research project Coloured Maps (2018–2021), we undertook an in-depth and systematic study of hand-drawn and hand-coloured maps from East Asia in the Museum am Rothenbaum (MARKK) in Hamburg and produced between the seventeenth and twentieth centuries.
With a multi-perspective approach and transdisciplinary methods (humanities and the sciences), we were able to pool and compare the research results from different fields of research on Asian maps. The aim of this publication is to provide a first general overview of the subject of colours on maps in East Asia in the period from the seventeenth to the early twentieth century and to stimulate further research on the topic.
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.