1.5 Proteinanalytik
Filtern
Erscheinungsjahr
- 2022 (13) (entfernen)
Dokumenttyp
Referierte Publikation
- nein (13) (entfernen)
Schlagworte
- Affinity chromatography (2)
- Amino acid analysis (2)
- Antibodies (2)
- Antibody (2)
- Bioconjugation (2)
- Drone (2)
- Glutaraldehyde (2)
- MALDI-TOF-MS (2)
- Polyglycerol (2)
- Protein hydrolysis (2)
- Protein quantification (2)
- Reductive amination (2)
- Remote Detection (2)
- Smart Dust (2)
- Traceability (2)
- 150th anniversary (1)
- AAA (1)
- ABC (1)
- ABID (1)
- ACE2 (1)
- ADAMTS4 (1)
- Acidic cleavage (1)
- Affinity extraction (1)
- Affinity support (1)
- Alkylierung (1)
- Aluminum oxide (1)
- Analysis (1)
- Analytical sciences (1)
- Antibody identification (1)
- Antibody light chain (1)
- Antibody purification (1)
- Antibody subclass (1)
- Aorta (1)
- Aromatic amino acid analysis AAAA (1)
- Aromatic amino acid analysis aaaa (1)
- BAM (1)
- BSA (1)
- Bioseparation (1)
- Bovine serum albumin (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- CCMV (1)
- COVID-19 (1)
- Calibration (1)
- Cardiovascular diseases (1)
- Carrier (1)
- Chip (1)
- Collection (1)
- Colorchanging Particles (1)
- Contrast agent (1)
- Corona (1)
- Coronavirus (1)
- Covalent conjugation (1)
- Cyclisierung (1)
- Database (1)
- Diagnostic (1)
- Downstream processing (1)
- Durchflusszytometrie (1)
- Dust sensor (1)
- ELISA (1)
- ESEM (1)
- Environment (1)
- Fluorescence (1)
- Fluoreszenz (1)
- Gas Tomography (1)
- Gold particles (1)
- Hard protein corona (1)
- Hazardous substances (1)
- Human plasma (1)
- Hyperbranched polymer (1)
- Identity (1)
- Igg (1)
- Imaging (1)
- Immunoglobulins (1)
- Immunoprecipitation (1)
- Internal standards (1)
- Jahrestag (1)
- LFIA (1)
- Lateral flow immunoassays (1)
- Latex particles (1)
- Life sciences (1)
- Limit of detection (1)
- Linker (1)
- Low-cost (1)
- MALDI (1)
- MALDI-TOF mass spectrometry (1)
- Magnetic resonance imaging (1)
- Material sciences (1)
- Medicine (1)
- Method (1)
- Metrology (1)
- Mikroparticles (1)
- Monoclonal antibody (1)
- Mutationen (1)
- Nanoparticle (1)
- Nanoparticles (1)
- Neutralisierende Antikörper (1)
- Nucleocapsid-Protein (1)
- OBOC library (1)
- Online software (1)
- Partikel (1)
- Passive Smart Dust (1)
- Peak overlap (1)
- Peptid-Aptamer (1)
- Peptid-Synthese (1)
- Peptidbibliothek (1)
- Peptide coverage (1)
- Peptide library (1)
- Peptide mass fingerprinting (1)
- Periodate oxidation (1)
- Pflanzenvirus (1)
- Phosphonic acids (1)
- Pollutant (1)
- Protein (1)
- Protein a (1)
- Protein immobilization (1)
- Purification (1)
- Quality assurance (1)
- RASEM (1)
- RBD (1)
- Reference material (1)
- Reference materials (1)
- Reproducibility crisis (1)
- Risk assessment (1)
- SAFIA (1)
- SARS-CoV-2 (1)
- SARS-CoV-2 antibody (1)
- SDS-PAGE (1)
- Sapphire (1)
- Screening (1)
- Self-assembled monolayer (SAM) (1)
- Sensor (1)
- Sensor network (1)
- Sequencing (1)
- Sequenzierung (1)
- Sodium chloride method (1)
- Soft protein corona (1)
- Software (1)
- Solid phase (1)
- Special issue (1)
- Spike-Protein (1)
- Sulfuric acid (1)
- Supernatant (1)
- Synthetic peptides (1)
- TEM (1)
- Trypsin (1)
- Tyrosine (1)
- Virus (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (13)
- 1.5 Proteinanalytik (13)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 8 Zerstörungsfreie Prüfung (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 1.4 Prozessanalytik (2)
- 1.9 Chemische und optische Sensorik (2)
- 4 Material und Umwelt (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 6 Materialchemie (2)
Eingeladener Vortrag
- nein (1)
Quantitative 1H Nuclear Magnetic Resonance (qNMR) of Aromatic Amino Acids for Protein Quantification
(2022)
qNMR is a valuable technique for metrological studies due to the uniformity of its signal response for all chemical species of an isotope of interest, which enables compound-independent calibration. However, protein quantification remained challenging as large molecules produce wide, low-intensity signals that reduce the already low sensitivity. Combining qNMR with the hydrolysis of protein samples into amino acids circumvents many of these issues and facilitates the use of NMR spectroscopy for absolute protein and peptide quantification.In this work, different conditions have been tested for quantifying aromatic amino acids and proteins. First, we examined the pH-based signal shifts in the aromatic region. The preferable pH depends on the selection of the amino acids for quantification and which internal standard substance should be used to avoid peak overlap. Several aromatic compounds, such as terephthalic acid, sulfoisophthalic acid, and benzene tricarboxylic acid, have been applied as internal standards. The quantification of amino acids from an amino acid standard, as well as from a certified reference material (bovine serum albumin), was performed. Using the first two suggested internal standards, recovery was ~ 97 % for histidine, phenylalanine, and tyrosine at a concentration of approximately 1 mM in solution. Acidic hydrolysis of a certified reference material (CRM) of bovine serum albumin (BSA) and subsequent quantification of Phe and Tyr yielded recoveries of 98 ± 2 and 88 ± 4 %, respectively, at a protein concentration of 16 g/L or 250 µM.
Screening against ADAMTS4 reveals a specific peptide, which was turned into an MRI probe. The aneurysm in a mouse modal was visualized via MRI. A differentiation between stable and unstable aneurysm in an early state was performed. Using the probe as tool for an easy and non-invasive rupture assessment is possible.
ABID
(2022)
In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0. This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
Nonporous corundum powder was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices.The common crosslinker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter was oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). As a proof of concept, IgG was extracted with protein A from crude human plasma. The advantages of corundum include the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, convenient handling, and flexible application.
High demand for remote sensing of hazardous substances. Possible solution: Use of distributed, low cost, and environmentally safe particles as passive sensors that can be read out remotely
Chemical intelligence on the particle surface can be easily modified Particles enable optically quantifiable response and inference of target substances (also no maintenance or power supply required
Remote sensing of hazardous substances is a key task that can be achieved with the help of remotely operated platforms equipped with specific sensors. A huge variety of methods and used vehicles have been developed for different purposes in recent years. The term smart dust refers to a science fiction novel and develop shortly after into a research proposal at UC Berkley funded by DARPA. Subsequently, the topic gained attraction but was overall considered as to complex for the technologies available at that time. In the launched passive smart dust project, we shift to a simple “chemical intelligent” passive sensor particle on the ground combined a read-out active sensor attached to an Unmanned Aerial Vehicle (UAV). The reactive particle surface can be preadjusted in the lab for exact desired properties regarding certain reactions to hazardous substances.
Moreover, the aimed interaction with the active sensor can be modified. Planed applications allow for different materials e.g., for short time measurement, being ecologically degradable, or weather stable for long time monitoring.
Current trends in materials and life sciences are flanked by the need to push detection limits to single molecules or single cells, enable the characterization of increasingly complex matrices or sophisticated nanostructures, speed up the time of analysis, reduce instrument complexity and costs, and improve the reliability of data. This requires suitable analytical tools such as spectroscopic, separation and imaging techniques, mass spectrometry, and hyphenated techniques as well as sensors and their adaptation to application-specific challenges in the environmental, food, consumer product, health sector, nanotechnology, and bioanalysis. Increasing concerns about health threatening known or emerging pollutants in drinking water, consumer products, and food and about the safety of nanomaterials led to a new awareness of the importance of analytical sciences. Another important driver in this direction is the increasing demand by legislation, particularly in view of the 17 sustainable development goals by the United Nations addressing clean energy, industry, and innovation, sustainable cities, clean water, and responsible consumption and production. In this respect, also the development of analytical methods that enable the characterization of material flows in production processes and support recycling concepts of precious raw materials becomes more and more relevant. In the future, this will provide the basis for greener production in the chemical industry utilizing recycled or sustainable starting materials.
This makes analytical chemistry an essential player in terms of the circular economy helping to increase the sustainability of production processes. In the life sciences sector, products based on proteins, such as therapeutic and diagnostic antibodies, increase in importance. These increasingly biotechnologically produced functional biomolecules pose a high level of complexity of matrix and structural features that can be met only by highly advanced methods for separation, characterization, and detection. In addition, metrological traceability and target definition are still significant challenges for the future, particularly in the life sciences.
However, innovative reference materials as required for the health and food sector and the characterization of advanced materials can only be developed when suitable analytical protocols are available. The so-called reproducibility crisis in sciences underlines the importance of improved measures of quality control for all kinds of measurements and material characterization. This calls for thorough method validation concepts, suitable reference materials, and regular interlaboratory comparisons of measurements as well as better training of scientists in analytical sciences.
The important contribution of analytical sciences to these developments is highlighted by a broad collection of research papers, trend articles, and critical reviews from these different application fields. Special emphasis is dedicated to often-overlooked quality assurance and reference materials.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids are used to introduce functional groups for further conjugations. The common cross-linker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter is oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower nonspecific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by SDS-PAGE. A binding capacity of 1.8 mg IgG per g of corundum powder was achieved. The advantages of corundum are the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, and flexible application.