Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- PCB (5)
- Forest soil (3)
- Boden (2)
- Normung (2)
- O-horizon (2)
- OCP (2)
- Organic pollutants (2)
- PAHs (2)
- PAK (2)
- Soil (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (16)
Evaluation of methods for the analysis of soils according to § 8 of the German Federal Soil Protection Act (BBodSchG)
The German Federal Soil Protection Act establishes the conditions for effective soil protection and remediation of contaminated sites. In the German Federal Soil Protection and Contaminated Sites Ordinance (BBodSchV) limiting values and methods for the determination of environmentally harmful substances in soils are fixed. The aim of this project was to evaluate selected methods by comparative investigations and proficiency testing schemes. New methods for the determination of inorganic and organic pollutants should be developed and compared with the existing standard
methods. Despite the widespread use of ICP-OES up to now no national or international standard is available for the determination of heavy metals in soil extracts with this analytical method. The influence of spectral and non spectral interferences on the accuracy of the results was systematically investigated, especially based on aqua regia soil extracts. Analyte concentration equivalents were determined, too. Based on these results a proposal for a standard was submitted to the corresponding working group of ISO TC 190.[...]
Die Normung von Analyseverfahren ermöglicht, dass Parameter unter standardisierten Bedingungen qualitätsgesichert ermittelt werden können. Insbesondere dann, wenn Verfahren in gesetzliche Regelwerke einfließen, ist es notwendig, dass die Ergebnisse sicher und vergleichbar sind und der Aufwand im Vollzug vertretbar ist. Derzeit werden viele Parameter in verschiedenen Verordnungen nach unterschiedlichen genormten Verfahren analysiert, was die Überwachungsarbeit erschwert und zudem unnötig teurer macht. Aus diesem Grund wir eine sogenannte horizontale Normung angestrebt, bei der geeignete Analyseverfahren auch Matrices-übergreifend genormt und anschließend EU-weit zitiert werden können. Grundvoraussetzung für die Verabschiedung als Norm ist die Validierung der Verfahren. Bereits vor einigen Jahren erteilte die EU ein Mandat an CEN (Europäisches Komitee zur Normung), um umweltrelevante Parameter Matrices-übergreifend zu validieren. Allerdings konnten nicht alle für diverse Verordnungsnovellen (z.B. Klärschlammverordnung) wichtigen Parameter im Rahmen dieses Projekts validiert werden. Aus diesem Grund wurde das aktuelle Vorhaben in den Umweltforschungsplan des BMUB aufgenommen und von der BAM durchgeführt. Im Forschungsvorhaben konnten im Bereich der anorganischen Parameter die CEN/TS 16170 (Elemente mit ICP-OES), CEN/TS 16171 (Elemente mit ICP-MS) und CEN/TS 16175-2 (Quecksilber mit CV-AFS) sowie im Bereich der organischen Parameter die CEN/TS 16181 (PAK mit HPLC und GC), die CEN/TS 16167 (PCB mit GC-MS und GC-ECD) und die CEN/TS 16190 (Dioxine, Furane und dl-PCB mit HR-GC-MS) für die Analyse von Klärschlamm, behandeltem Bioabfall und Boden erfolgreich validiert werden. Die validierten Verfahren stehen nun kurz vor der Verabschiedung als EN (Europäische Norm).
Efficiency Evaluation of Extraction Methods for Analysis of OCPs and PCBs in Soils of Varying TOC
(2017)
Organochlorine pesticides and polychlorinated biphenyls are toxic, carcinogenic, and have a high potential for bioaccumulation. Due to their stability, they are still considered an environmental problem even though the use of most of them has been phased out several decades ago. Soil is a matrix which can retain these contaminants to a great extent. This ability is often associated with the total organic carbon content (TOC). In order to judge the pollution status of soil and to make monitoring data more easily comparable a simple, yet robust extraction method is needed. Agitation solid-liquid-extraction is well suited for this purpose. However, the influence of TOC on the analyte recovery has to be known. For the presented study, 12 organochlorine pesticides and 7 polychlorinated biphenyls were spiked into four model soils with organic carbon contents between 1.6% - 13.3%. The matrices were extracted using solid-liquid extraction between 45 minutes and 16 hours. For comparison, all soils were also extracted using pressurised liquid extraction and Soxhlet extraction. After clean-up the extracts were measured using a gas chromatography-mass spectrometry (GC-MS) system. Statistical analysis of the results implied that the TOC content of the soils did not have significant influence on the extraction efficiency. A longer solid-liquid extraction time did not necessarily increase analyte recovery: Extraction for one hour resulted in 88% recovery while 16 hour extraction led to 89%. Thus, the efficiency of all the methods was comparable for all model soils. Additional investigations regarding GC liner performance highlighted the need for isotopically labelled standards during the analysis of thermolabile pesticides.
ISBN: Im Zuge der Harmonisierung der Rechtsvorschriften der Mitgliedsstaaten der Europäischen Gemeinschaft wurde im September 1996 die Richtlinie 96/59/EG des Rates über die Beseitigung polychlorierter Biphenyle und polychlorierter Terphenyle (PCB/PCT) verabschiedet. Ziel dieser Richtlinie ist die Angleichung der Rechtsvorschriften der Mitgliedstaaten über die kontrollierte Beseitigung der PCB, die Dekontaminierung oder Beseitigung PCB-haltiger Geräte und die Beseitigung von PCB-Abfall. In der Bundesrepublik Deutschland wurde mit der Verabschiedung der PCB/PCT- Abfallverordnung vom 26. Juni 2000 die EU-Richtlinie umgesetzt. Entsprechend der PCB/PCT-Abfallverordnung wird für PCB-haltigen Abfall ein Grenzwert von 50 mg/kg festgelegt. Beim Haupteinsatzgebiet der PCB - als Isolierflüssigkeiten in Transformatoren - ist die Bestimmung des PCB-Gehaltes durch DIN-Normen geregelt. Polychlorierte Biphenyle wurden auch als Weichmacher in Dichtungsmassen und Kunststoffen, z.B. in Kabelummantelungen, und als Flammschutzmittelanstrich für Holz eingesetzt. Für feste Abfallmatrices gibt es keine verbindliche Prüfvorschrift. Ziel des Projektes war die Erarbeitung und Validierung eines Prüfverfahrens zur Bestimmung von PCB und PCT in organischen Abfallmatrices wie Kabelshredder und Altholz.